Terraced apartments as a typology of the buildings are new approaches to meet energy conservation targets. This principle in the form of interactive spaces contributes to an incorporation of interior and exterior, daylight addition and exploitation of natural ventilation. This study mainly investigates the natural ventilation exploitation of a terraced apartment in the hot and humid region. One solid block and 4 porous apartments with different terrace depths (TD) are evaluated using computational fluid dynamics (CFD) analysis. The k-ε turbulence model was adapted to simulate airflow in and around a mid-rise building with 42 residential blocks. CFD analysis compares the effect of permeability in the form of terraces on wind behaviour and natural ventilation efficiency in a mid-rise building. Ventilation assessment parameters such as mean air velocity and mean age of air are measured to compare the natural ventilation performance. The simulation results clearly indicate that the implementation of permeability in the form of terraces can enhance building natural ventilation performance significantly. However, it is proved that some physical configurations such as terrace depth can influence this performance greatly. According to the results, increasing the terrace depth up to 1.2 meters will enhance the mean wind velocity 40%–88% inside the room, 10.61%–12.29% near the window and 63.44% on the openings. Velocity diagram follows a descending process after TD 1.2. The mean wind speed decreases to 25.53% inside the room, 15.09% inside terraces and 1.09% near the window. The average wind velocity on the openings is revealed to be 1.54 to 1.64 times larger in the porous models than the solid one. On the other hand, porous cases indicate lower values for the mean age of air compared to the solid model. This study provides proper guidelines to predict ventilation performance and to improve the design of naturally ventilated mid-rise buildings in hot and humid regions.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Allard F, Santamouris M (1998). Natural Ventilation in Buildings: A Design Handbook. London: James & James Ltd.

    Google Scholar 

  • Asfour OS (2010). Prediction of wind environment in different grouping patterns of housing blocks. Energy and Buildings, 42: 2061–2069.

    Article  Google Scholar 

  • Asfour OS, Gadi MB (2007). A comparison between CFD and network models for predicting wind-driven ventilation in buildings. Building and Environment, 42: 4079–4085.

    Article  Google Scholar 

  • Aynsley R (2014). Natural ventilation in passive design. Environment Design Guide, 80: 1–16.

    Google Scholar 

  • Bittencourt L, Peixoto L (2001). The influence of different courtyard configurations on natural ventilation through low-rise school buildings. In: Proceedings of the 7th International IBPSA Building Simulation Conference, Rio de Janeiro, Brazil.

    Google Scholar 

  • Bronsema B (2010). Earth, wind & fire—Air-conditioning powered by nature. In: Proceedings of the 10th REHVA World Congress, Antalya, Turkey.

    Google Scholar 

  • Chan, H-Y, Riffat SB, Zhu J (2010). Review of passive solar heating and cooling technologies. Renewable and Sustainable Energy Reviews, 14: 781–789.

    Article  Google Scholar 

  • Cui S, Stabat P, Marchio D (2016). Numerical simulation of wind-driven natural ventilation: Effects of loggia and facade porosity on air change rate. Building and Environment, 106: 131–142.

    Article  Google Scholar 

  • Edwards, B, Sibley M, Hakmi M, Land P (2006). Courtyard housing: Past, present and future. New York: Taylor & Francis.

    Google Scholar 

  • EIA (2016). International Energy Outlook 2016. Washington, D.C. U.S. Energy Information Administration.

    Google Scholar 

  • Etheridge D, Ford B (2008). Natural ventilation of tall buildings—Options and limitations. In: Proceedings of CTBUH 8th World Congress, Dubai, United Arab Emirates.

    Google Scholar 

  • Farea TG, Ossen DR, Alkaff S, Kotani H (2015). CFD modeling for natural ventilation in a lightwell connected to outdoor through horizontal voids. Energy and Buildings, 86: 502–513.

    Article  Google Scholar 

  • Feustel H (1999). COMIS—An international multizone air-flow and contaminant transport model. Energy and Buildings, 30: 3–18.

    Article  Google Scholar 

  • Franke J (2006). Recommendations of the COST action C14 on the use of CFD in predicting pedestrian wind environment. In: Proceedings of the 4th International Symposium on Computational Wind Engineering, Yokohama, Japan.

    Google Scholar 

  • Franke J, Hirsch C, Jensen AG, Krüs HW, Schatzmann M, Westbury PS, Miles SD, Wisse JA, Wright NG (2004). Recommendations on the use of CFD in wind engineering. In: Proceedings of International Conference on Urban Wind Engineering and Building Aerodynamics, Sint-Genesius-Rode, Belgium.

    Google Scholar 

  • Ghiaus, C, Roulet C (2005). Strategies for Natural Ventilation. London: Assessment and Design Earthscan.

    Google Scholar 

  • Givoni B (1994). Passive Low Energy Cooling of Buildings. New York: John Wiley & Sons.

    Google Scholar 

  • Golany G (1995). Ethics and Urban Design: Culture, Form and Environment. New York: John Wiley & Sons.

    Google Scholar 

  • Grant EJ (2003). Design and implementation of a pressure-equalizing vent system for low-slope roofs. Master Thesis, Virginia Tech, USA.

    Google Scholar 

  • Hirano T, Kato S, Murakami S, Ikaga T, Shiraishi Y (2006). A study on a porous residential building model in hot and humid regions: Part 1. The natural ventilation performance and the cooling load reduction effect of the building model. Building and Environment, 41: 21–32.

    Article  Google Scholar 

  • Hu C-H, Kurabuchi K, Ohba M (2005). Numerical study of cross-ventilation using two-equation RANS turbulence models. International Journal of Ventilation, 4: 123–131.

    Google Scholar 

  • Karava P (2008). Airflow prediction in buildings for natural ventilation design: Wind tunnel measurements and simulation. PhD Thesis, Concordia University, Canada.

    Google Scholar 

  • Karava P, Stathopoulos T, Athienitis AK (2011). Airflow assessment in cross-ventilated buildings with operable façade elements. Building and Environment, 46: 266–279.

    Article  Google Scholar 

  • Khosravi SN, Saadatjoo P, Mahdavinejad M, Amindeldar S (2016). The effect of roof details on natural ventilation efficiency in isolated single buildings. In: Proceedings of PLEA2016: Cities, Buildings, People: Towards Regenerative Environments, Los Angeles, USA.

    Google Scholar 

  • Kim Y C, Yoshida A, Tamura Y (2012). Characteristics of surface wind pressures on low-rise building located among large group of surrounding buildings. Engineering Structures, 35: 18–28.

    Article  Google Scholar 

  • Kleiven T (2003). Natural ventilation in buildings: Architectural concepts, consequences and possibilities. PhD Thesis, Norwegian University of Science and Technology, Norway.

    Google Scholar 

  • Kotsopoulos SD (2007). Design concepts in architecture: The porosity paradigm. In: Proceedings of the 1st International Workshop on Semantic Web and Web 2.0 in Architectural, Product and Engineering Design, Busan, Korea.

    Google Scholar 

  • Kubota T, Miura M, Tominaga Y, Mochida A (2008). Wind tunnel tests on the relationship between building density and pedestrian-level wind velocity: Development of guidelines for realizing acceptable wind environment in residential neighborhoods. Building and Environment, 43: 1699–1708.

    Article  Google Scholar 

  • Levitan ML, Mehta KC, Vann WP, Holmes JD (1991). Field measurements of pressures on the Texas tech building. Journal of Wind Engineering and Industrial Aerodynamics, 38: 227–234.

    Article  Google Scholar 

  • Lin MT, Wei HY, Lin YJ, Wu HF, Liu PH (2010). Natural ventilation applications in hot humid climate: A preliminary design for the college of design at NTUST. In: Proceedings of the 17th Symposium for Improving Building Systems in Hot and Humid Climates, Austin, TX, USA.

    Google Scholar 

  • Littlefair P, Santamouris M, Alvarez S, Dupagne A, Hall D, Teller J, Coronel JF, Papanikolaou N (2000). Environmental Site Layout Planning: Solar Access, Microclimate and Passive Cooling in Urban Areas. Watford, UK: Building Research Establishment Ltd (BRE).

    Google Scholar 

  • Mahdavinejad M, Javanroodi K (2012). Comparative evaluation of airflow in two kinds of Yazdi and Kermani Wind-Towers. Journal of Fine Art—Tehran University, 3(6): 69–80.

    Google Scholar 

  • Mirzaei F, Eghbali SR, Mahdavinejad M (2014). Proposing a more efficient model to enhance natural ventilation in residential buildings. Environment and Ecology Research, 2: 194–205.

    Google Scholar 

  • Mistriotis A, Arcidiacono C, Picuno P, Bot GPA, Scarascia-Mugnozzae G (1997). Computational analysis of ventilation in greenhouses at zero- and low-wind speeds. Agricultural and Forest Meteorology, 88: 121–135.

    Article  Google Scholar 

  • Mochida A, Tominaga Y, Murakami S, Yoshie R, Ishihara T, Ooka R (2002). Comparison of various k-e models and DSM applied to flow around a high-rise building—Report on AIJ cooperative project for CFD prediction of wind environment. Wind and Structures, 5: 227–244.

    Article  Google Scholar 

  • Montazeri H, Blocken B, Janssen W, van Hoff T (2012). CFD analysis of wind comfort on high-rise building balconies: validation and application. In: Proceedings of the 7th International Colloquium on Bluff Body Aerodynamics and Applications (BBAA7), Shanghai, China.

    Google Scholar 

  • Mora-Pérez M, Guillén-Guillamón I, López-Jiménez PA (2015). Computational analysis of wind interactions for comparing different buildings sites in terms of natural ventilation. Advances in Engineering Software, 88: 73–82.

    Article  Google Scholar 

  • Murakami S, Kato S, Ooka R, Shiraishi Y (2004). Design of a poroustype residential building model with low environmental load in hot and humid Asia. Energy and Buildings, 36: 1181–1189.

    Article  Google Scholar 

  • Nguyen AT, Reiter S (2011). The effect of ceiling configurations on indoor air motion and ventilation flow rates. Building and Environment, 46: 1211–1222.

    Article  Google Scholar 

  • Ntinas GK, Zhang G, Fragos VP, Bochtis DD, Nikita-Martzopoulou Ch (2014). Airflow patterns around obstacles with arched and pitched roofs: Wind tunnel measurements and direct simulation. European Journal of Mechanics—B/Fluids, 43: 216–229.

    Article  MATH  Google Scholar 

  • Ok V, Yasa E, Özgunler M (2008). An experimental study of the effects of surface openings on air flow caused by wind in courtyard buildings. Architectural Science Review, 51: 263–268.

    Article  Google Scholar 

  • Osman M (2011). Evaluating and enhancing design for natural ventilation in walk-up public housing blocks in the Egyptian desert climatic design region. PhD Thesis, Dundee University, Egypt.

    Google Scholar 

  • Saadatjoo P, Mahdavinejad M, Khosravi SN, Kaveh N (2016). Effect of courtyard proportion on natural ventilation efficiency. In: Proceedings of the 30th IASTEM International Conference, Dubai, United Arab Emirates.

    Google Scholar 

  • Sharples S, Bensalem R (2001). Airflow in courtyard and atrium buildings in the urban environment: A wind tunnel study. Solar Energy, 70: 237–244.

    Article  Google Scholar 

  • Shirasawa T, Tominaga Y, Yoshie R, Mochida A, Yoshino H, Kataoka H, Nozu T (2003). Development of CFD method for predicting wind environment around a high-rise building Part 2: The cross comparison of CFD results using various k-ε models for the flowfield around a building model with 4:4:1 shape. AIJ Journal of Technology and Design, 9(18): 169–174.

    Article  Google Scholar 

  • Siew CC, Che-Ani AI, Tawil NM, Abdullah NAG, Mohd-Tahir M (2011). Classification of natural ventilation strategies in optimizing energy consumption in Malaysian office buildings. Procedia Engineering, 20: 363–371.

    Article  Google Scholar 

  • Tablada A, Blocken B, Carmeliet J, De Troyer F, Herschure H (2005). Geometry of building’s courtyards to favour natural ventilation: Comparison between wind tunnel experiment and numerical simulation. In: Proceedings of the 2005 World Sustainable Building Conference, Tokyo, Japan.

    Google Scholar 

  • Taleb HM (2015). Natural ventilation as energy efficient solution for achieving low-energy houses in Dubai. Energy and Buildings, 99: 284–291.

    Article  Google Scholar 

  • Taylor B (2008). The first line of defense: Passive design at an urban scale, in Air conditioning and the low carbon cooling challenge. In: Proceedings of Conference: Air Conditioning and the Low Carbon Cooling Challenge, Windsor, UK.

    Google Scholar 

  • Tominaga Y, Yoshie R, Mochida A, Kataoka H, Harimoto K, Nozu T (2005). Cross comparisons of CFD prediction for wind environment at pedestrian level around buildings, Part 2: Comparison of results for flowfield around building complex in actual urban area. In: Proceedings of the 6th Asia-Pacific Conference on Wind Engineering, Seoul, Korea.

    Google Scholar 

  • Tominaga Y, Mochida A, Yoshie R, Kataoka H, Nozu T, Yoshikawa M, Shirasawa T (2008). AIJ guidelines for practical applications of CFD to pedestrian wind environment around buildings. Journal of Wind Engineering and Industrial Aerodynamics, 96: 1749–1761.

    Article  Google Scholar 

  • Uematsu Y, Isyumov N (1999). Wind pressures acting on low-rise buildings. Journal of Wind Engineering and Industrial Aerodynamics, 82: 1–25.

    Article  Google Scholar 

  • Walker CE (2006). Methodology for the evaluation of natural ventilation in buildings using a reduced-scale air model. PhD Thesis, Massachusetts Institute of Technology, USA.

    Google Scholar 

  • Watson D, Labs K (1983). Climatic design: Energy-efficient building principles and practices. New York: McGraw-Hill.

    Google Scholar 

  • Yoshie R, Mochida A, Tominaga Y, Kataoka H, Harimoto K, Nozu T, Shirasawa T (2007). Cooperative project for CFD prediction of pedestrian wind environment in the Architectural Institute of Japan. Journal of Wind Engineering and Industrial Aerodynamics, 95: 1551–1578.

    Article  Google Scholar 

  • Yuan C, Ng E (2012). Building porosity for better urban ventilation in high-density cities—A computational parametric study. Building and Environment, 50: 179–189.

    Article  Google Scholar 

  • Zhai Z (2006). Application of computational fluid dynamics in building design: Aspects and trends. Indoor and Built Environment, 15: 305–313.

    Article  Google Scholar 

  • Zhang Z, Zhang W, Zhai Z, Chen Q (2007). Evaluation of various turbulence models in predicting airflow and turbulence in enclosed environments by CFD: Part 2—Comparison with experimental data from literature. HVAC&R Research, 13: 871–886.

    Article  Google Scholar 

  • Zhou C, Wang Z, Chen Q, Jiang Y, Pei J (2014). Design optimization and field demonstration of natural ventilation for high-rise residential buildings. Energy and Buildings, 82: 457–465.

    Article  Google Scholar 

  • Zhou L, Haghighat F (2009). Optimization of ventilation system design and operation in office environment, Part I: Methodology. Building and Environment, 44: 651–656.

    Article  Google Scholar 

  • Zong C, Wu W, Zhang GQ, Shen X, Ntinas G (2013). A case study of airflow patterns around an arched type agricultural building: Investigating mesh convergence of different turbulence models. In: Proceedings of the 1st International Symposium on CFD Applications in Agriculture, Valencia, Spain.

    Google Scholar 

Download references

Acknowledgements

This paper is part of PhD thesis entitled “Porous Architecture Towards Energy Efficient Buildings (Concept of Porosity for Enhancing Naturally Ventilated Mid-rise Buildings in Hot and Humid Regions)” conducted by the first author at Tarbiat Modares University under the supervision of the second author, and partially done at Aarhus University under the supervision of third author.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Mohammadjavad Mahdavinejad.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Saadatjoo, P., Mahdavinejad, M. & Zhang, G. A study on terraced apartments and their natural ventilation performance in hot and humid regions. Build. Simul. 11, 359–372 (2018). https://doi.org/10.1007/s12273-017-0407-7

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12273-017-0407-7

Keywords

Navigation