Skip to main content
Log in

Micromotion in cemented rotating platform total knee arthroplasty: cemented tibial stem versus hybrid fixation

  • Original Article
  • Published:
Archives of Orthopaedic and Trauma Surgery Aims and scope Submit manuscript

Abstract

Introduction: Improving the longevity and reliability of cemented total knee arthroplasty (TKA) remains a major step to achieve. It is still unclear, whether a cemented tibial stem reduces micromotion of the tibial tray and produces therefore a better initial stability or not. The higher conformity of rotating platform design and the possible rotary forces to the tibial platform may produce higher micromotion when the tibial stem remains cementless (hybrid fixation). Materials and methods: An in vitro study was performed using the PFC® mobile bearing tibial tray (DePuy®, Warswa, IN, USA) to test the hypothesis that the addition of cement surrounding the tibial stem reduces micromotion of the tibial tray in cemented TKA with mobile bearing design. Ten tibial trays with mobile design were implanted in sawbones with a 3-mm cement mantle beneath the baseplate of the tibial tray and with or without the cemented stem. Tibial trays were loaded additionally in the ventral, lateral, medial and posterior positions with 2,500 N using the Zwick Z010® instrumentation and HBM pick up Hottinger Baldwin®. Results: In this study, a significant increased mean maximum liftoff was found when only cementing the tibial baseplate (hybrid fixation), compared to the fully cemented tibial tray (P<0.02). Conclusion: In conclusion, the stem of mobile bearing tibial components should be cemented to provide increased micromotion and earlier loosening.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3

Similar content being viewed by others

References

  1. Ahmed AM, Raad S, Miller JE (1984) Metal/cement interface strength in cemented stem fixation. J Orthop Res 2:105–111

    Article  PubMed  CAS  Google Scholar 

  2. Bert JM, McShane M (1998) Is it necessary to cement the tibial stem in cemented TKA? Clin Orthop 356:73–78

    Article  PubMed  Google Scholar 

  3. Chon JG, Lombardi AV, Berend KR (2004) Hybrid stem fixation in revision total knee arthroplasty (TKA). Surg Technol Int 12:214–220

    PubMed  Google Scholar 

  4. Davies J, Harris W (1994) Tensile bonding strength of the cement–prosthesis interface. Orthopedics 17:171–178

    PubMed  CAS  Google Scholar 

  5. Dempsey A, Finlay J, Bourne R, Rorabeck CH, Scott MA, Millman JC (1989) Stability and anchorage considerations for cementless tibial components. J Arthroplasty 4:223–229

    Article  PubMed  CAS  Google Scholar 

  6. Font-Rodriguez DE, Scuderi GR, Insall JN (1997) Survivorship of cemented TKA. Clin Orthop 345:79–86

    Article  PubMed  Google Scholar 

  7. Huang CH, Ma HM, Lee YM, Ho FY (2003) Long-term results of low contact stress mobile-bearing TKR. Clin Orthop 416:265–270

    Article  PubMed  Google Scholar 

  8. Jacobs W, Anderson P, Limbeek J, Wymenga A (2004) Mobile vs. fixed bearing prosthesis for TKA for postoperative functional status in patients with osteoarthritis and rheumatoid arthritis. Cochrane Database Syst Rev (2):CD 003130

  9. James S, Schmalzried T, McGarry FJ, Harris W (1991) Corrosity reduction at the femoral prosthesis/cement interface. Trans Soc Biomater 14:50

    Google Scholar 

  10. Keller JC, Lautenschlager E, Grayson W, Meyer P (1980) Factors affecting surgical alloy/bone cement interface adhesion. J Biomed Mater Res 14:639–644

    Article  PubMed  CAS  Google Scholar 

  11. Kim YH, Kook HK, Kim JS (2001) Comparison of fixed-bearing and mobile-bearing total knee arthroplasties. Clin Orthop 392:101–115

    Article  PubMed  Google Scholar 

  12. McEwen HMJ, Goldsmith AAJ, Auger DD, Hardaker CH, Stone MH, Fisher J (2001) Wear of fixed bearing and rotating platform mobile bearing knees subjected to high levels of internal and external tibial rotation. J Mater Sci Mater Med 12:1049–1052

    Article  PubMed  CAS  Google Scholar 

  13. Miller JE, Burke DO, Krause W, Kelebay LC (1979) An experimental technique for improved fixation of implant components in human TKA. Trans Orthop Res Soc 4:303

    Google Scholar 

  14. Peters CL, Craig MA, Mohr RA, Bachus KN (2003) Tibial component fixation with cement: full-versus surface-cementation techniques. Clin Orthop 409:158–168

    Article  PubMed  Google Scholar 

  15. Price AJ, Rees JL, Beard D, Juszczak E, Carter S, White S, de Steiger R, Dodd CA, Gibbons M, McLardy-Smith P, Goodfellow JW, Murray DW (2003) A mobile-bearing total knee prosthesis compared with fixed-bearing prosthesis. A multicentre single-blind randomised controlled trial. J Bone Joint Surg Br 85:62–67

    Article  PubMed  CAS  Google Scholar 

  16. Ranawat AS, Rossi R, Loreti I, Rasquina VJ, Rodriguez JA, Ranawat CS (2004) Comparison of the PFC sigma fixed-bearing and rotating-platform TKA in the same patient: short term results. J Arthroplasty 19:35–39

    Article  PubMed  Google Scholar 

  17. Rodriguez JA, Bhende H, Ranawatt CS (2001) Total condylar knee replacement: a 20-year followup study. Clin Orthop 288:10–17

    Google Scholar 

  18. Schunck J, Jerosch J (2003) Knee arthroplasty. Mobile- and fixed bearing design. Orthopade 32:477–483

    PubMed  CAS  Google Scholar 

  19. Seki T, Bourgeault C, Chareancholvanich AK (1997) Does a central stem affect bone strain and the stability of cemented tibial tray in primary revision TKA? Trans Orthop Res Soc 22:635

    Google Scholar 

  20. Strickland A, Chan K, Andriacchi T, Miller J (1998) The initial fixation of porous-coated tibial components evaluated by the study of rigid body motion under static load. Trans Orthop Res Soc 13:476

    Google Scholar 

  21. Volz R, Lee R (1988) The effect of the stem and stem length on mechanical stability of tibial components. Trans Orthop Res Soc 13:472

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to C. Luring.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Luring, C., Perlick, L., Trepte, C. et al. Micromotion in cemented rotating platform total knee arthroplasty: cemented tibial stem versus hybrid fixation. Arch Orthop Trauma Surg 126, 45–48 (2006). https://doi.org/10.1007/s00402-005-0082-5

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00402-005-0082-5

Keywords

Navigation