Abstract
Introduction: Improving the longevity and reliability of cemented total knee arthroplasty (TKA) remains a major step to achieve. It is still unclear, whether a cemented tibial stem reduces micromotion of the tibial tray and produces therefore a better initial stability or not. The higher conformity of rotating platform design and the possible rotary forces to the tibial platform may produce higher micromotion when the tibial stem remains cementless (hybrid fixation). Materials and methods: An in vitro study was performed using the PFC® mobile bearing tibial tray (DePuy®, Warswa, IN, USA) to test the hypothesis that the addition of cement surrounding the tibial stem reduces micromotion of the tibial tray in cemented TKA with mobile bearing design. Ten tibial trays with mobile design were implanted in sawbones with a 3-mm cement mantle beneath the baseplate of the tibial tray and with or without the cemented stem. Tibial trays were loaded additionally in the ventral, lateral, medial and posterior positions with 2,500 N using the Zwick Z010® instrumentation and HBM pick up Hottinger Baldwin®. Results: In this study, a significant increased mean maximum liftoff was found when only cementing the tibial baseplate (hybrid fixation), compared to the fully cemented tibial tray (P<0.02). Conclusion: In conclusion, the stem of mobile bearing tibial components should be cemented to provide increased micromotion and earlier loosening.
Similar content being viewed by others
References
Ahmed AM, Raad S, Miller JE (1984) Metal/cement interface strength in cemented stem fixation. J Orthop Res 2:105–111
Bert JM, McShane M (1998) Is it necessary to cement the tibial stem in cemented TKA? Clin Orthop 356:73–78
Chon JG, Lombardi AV, Berend KR (2004) Hybrid stem fixation in revision total knee arthroplasty (TKA). Surg Technol Int 12:214–220
Davies J, Harris W (1994) Tensile bonding strength of the cement–prosthesis interface. Orthopedics 17:171–178
Dempsey A, Finlay J, Bourne R, Rorabeck CH, Scott MA, Millman JC (1989) Stability and anchorage considerations for cementless tibial components. J Arthroplasty 4:223–229
Font-Rodriguez DE, Scuderi GR, Insall JN (1997) Survivorship of cemented TKA. Clin Orthop 345:79–86
Huang CH, Ma HM, Lee YM, Ho FY (2003) Long-term results of low contact stress mobile-bearing TKR. Clin Orthop 416:265–270
Jacobs W, Anderson P, Limbeek J, Wymenga A (2004) Mobile vs. fixed bearing prosthesis for TKA for postoperative functional status in patients with osteoarthritis and rheumatoid arthritis. Cochrane Database Syst Rev (2):CD 003130
James S, Schmalzried T, McGarry FJ, Harris W (1991) Corrosity reduction at the femoral prosthesis/cement interface. Trans Soc Biomater 14:50
Keller JC, Lautenschlager E, Grayson W, Meyer P (1980) Factors affecting surgical alloy/bone cement interface adhesion. J Biomed Mater Res 14:639–644
Kim YH, Kook HK, Kim JS (2001) Comparison of fixed-bearing and mobile-bearing total knee arthroplasties. Clin Orthop 392:101–115
McEwen HMJ, Goldsmith AAJ, Auger DD, Hardaker CH, Stone MH, Fisher J (2001) Wear of fixed bearing and rotating platform mobile bearing knees subjected to high levels of internal and external tibial rotation. J Mater Sci Mater Med 12:1049–1052
Miller JE, Burke DO, Krause W, Kelebay LC (1979) An experimental technique for improved fixation of implant components in human TKA. Trans Orthop Res Soc 4:303
Peters CL, Craig MA, Mohr RA, Bachus KN (2003) Tibial component fixation with cement: full-versus surface-cementation techniques. Clin Orthop 409:158–168
Price AJ, Rees JL, Beard D, Juszczak E, Carter S, White S, de Steiger R, Dodd CA, Gibbons M, McLardy-Smith P, Goodfellow JW, Murray DW (2003) A mobile-bearing total knee prosthesis compared with fixed-bearing prosthesis. A multicentre single-blind randomised controlled trial. J Bone Joint Surg Br 85:62–67
Ranawat AS, Rossi R, Loreti I, Rasquina VJ, Rodriguez JA, Ranawat CS (2004) Comparison of the PFC sigma fixed-bearing and rotating-platform TKA in the same patient: short term results. J Arthroplasty 19:35–39
Rodriguez JA, Bhende H, Ranawatt CS (2001) Total condylar knee replacement: a 20-year followup study. Clin Orthop 288:10–17
Schunck J, Jerosch J (2003) Knee arthroplasty. Mobile- and fixed bearing design. Orthopade 32:477–483
Seki T, Bourgeault C, Chareancholvanich AK (1997) Does a central stem affect bone strain and the stability of cemented tibial tray in primary revision TKA? Trans Orthop Res Soc 22:635
Strickland A, Chan K, Andriacchi T, Miller J (1998) The initial fixation of porous-coated tibial components evaluated by the study of rigid body motion under static load. Trans Orthop Res Soc 13:476
Volz R, Lee R (1988) The effect of the stem and stem length on mechanical stability of tibial components. Trans Orthop Res Soc 13:472
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Luring, C., Perlick, L., Trepte, C. et al. Micromotion in cemented rotating platform total knee arthroplasty: cemented tibial stem versus hybrid fixation. Arch Orthop Trauma Surg 126, 45–48 (2006). https://doi.org/10.1007/s00402-005-0082-5
Received:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00402-005-0082-5