Abstract
Modern highly multiplexed short tandem repeat (STR) assays used by the forensic human-identity community require tight control of the initial amount of sample DNA amplified in the polymerase chain reaction (PCR) process. This, in turn, requires the ability to reproducibly measure the concentration of human DNA, [DNA], in a sample extract. Quantitative PCR (qPCR) techniques can determine the number of intact stretches of DNA of specified nucleotide sequence in an extremely small sample; however, these assays must be calibrated with DNA extracts of well-characterized and stable composition. By 2004, studies coordinated by or reported to the National Institute of Standards and Technology (NIST) indicated that a well-characterized, stable human DNA quantitation certified reference material (CRM) could help the forensic community reduce within- and among-laboratory quantitation variability. To ensure that the stability of such a quantitation standard can be monitored and that, if and when required, equivalent replacement materials can be prepared, a measurement of some stable quantity directly related to [DNA] is required. Using a long-established conventional relationship linking optical density (properly designated as decadic attenuance) at 260 nm with [DNA] in aqueous solution, NIST Standard Reference Material (SRM) 2372 Human DNA Quantitation Standard was issued in October 2007. This SRM consists of three quite different DNA extracts: a single-source male, a multiple-source female, and a mixture of male and female sources. All three SRM components have very similar optical densities, and thus very similar conventional [DNA]. The materials perform very similarly in several widely used gender-neutral assays, demonstrating that the combination of appropriate preparation methods and metrologically sound spectrophotometric measurements enables the preparation and certification of quantitation [DNA] standards that are both maintainable and of practical utility.
Similar content being viewed by others
References
Nicklas JA, Buel E (2003) Anal Bioanal Chem 376:1160–1167
Butler JM, Coble MD, Decker AE, Duewer DL, Hill CR, Kline MC, Redman JW, Vallone PM (2006) Int Congr Ser 1288:628–635
Duewer DL, Kline MC, Redman JW, Newall PJ, Reeder DJ (2001) J Forensic Sci 246:1199–1210
Kline MC, Duewer DL, Redman JW, Butler JM (2003) Anal Chem 75:2463–2469
Kline MC, Duewer DL, Redman JW, Butler JM (2005) J Forensic Sci 50(3):571–578
Krenke BE, Ekenberg S, Frackman S, Hoffmann K, Sprecher CJ, Storts DR (2005) Profiles in DNA (Promega Corporation) 8(1): 3-5; http://www.promega.com/profiles/801/801_03.html
Killeen AA (1997) Clinic Lab Med 17(1):1–19
Thompson M (1996) Analyst 121(3):285–288
Nielsen K, Mogensen HS, Hedman J, Niederstätter H, Parson W, Morling N (2008) Forensic Sci Intl Genetics 2:226–230
Warburg O, Christian W (1942) Biochem Z 310:384–421
Sambrook J, Russell DW (2001) Molecular cloning a laboratory manual. Cold Spring Harbor Laboratory Press, Cold Spring Harbor, New York
International Union of Pure and Applied Chemistry Commission on Molecular Structure and Spectroscopy, and Commission on Quantities and Units in Clinical Chemistry (1985) Pure Appl Chem 57:105–120
SRM 2372—Human DNA Quantitation Standard Certificate https://www-s.nist.gov/srmors/view_detail.cfm?srm=2372
NIST Special Publication 260-136—“Definitions of Terms and Modes Used at NIST for Value-Assignment of Reference Materials for Chemical Measurements” (2000); http://ts.nist.gov/MeasurementServices/ReferenceMaterials/upload/SP260-136.pdf
Miller SA, Dykes DD, Polesky HF (1988) Nucleic Acids Res 16(3):1215
Applied Biosystems (2003) Quantifiler human DNA quantitation kit and Quantifiler Y human male DNA quantitation kit user’s manual, Part Number 4344790 Rev A. Foster City, CA
Nicklas JA, Buel E (2003) J Forensic Sci 48:936–944
Richard ML, Frappier RH, Newman JC (2003) J Forensic Sci 48:1041–1046
Timken MD, Swango KL, Orrego C, Buoncristiani MR (2005) J Forensic Sci 50:1044–1060
Nicklas JA, Buel E (2006) J Forensic Sci 51:1005–1015
Swango KL, Timken MD, Chong MD, Buoncristiani MR (2006) Forensic Sci Int 158:14–26
Knox C, Krenke B (2007) Forensic Magazine April/May 2007; http://www.forensicmag.com/articles.asp?pid=141
Mandrekar MN, Erickson AM, Kopp K, Krenke BE, Mandrekar PV, Nelson R, Peterson K, Shultz J, Tereba A, Westphal N (2001) Croat Med J 42:336–339
Walsh PS, Varlaro J, Reynolds R (1992) Nucleic Acids Res 20:5061–5065
Singer VL, Jones LJ, Yue ST, Haugland RP (1997) Anal Biochem 249:228–238
Modeled after the original instrument described in: Mavrodineanu R (1972) J Res Natl Bur Stds 76A:115-125
Analytical Methods Committee, Royal Society of Chemistry (1989) Analyst, 114:1693-8 See also: http://www.rsc.org/images/brief6_tcm18-25948.pdf and http://www.rsc.org/ Membership/Networking/InterestGroups/Analytical/AMC/Software/RobustStatistics.asp
ISO (1994) ISO 5725-2. Accuracy (trueness and precision) of measurement methods and results. Part 2: basic method for the determination of repeatability and reproducibility of a standard measurement method. ISO, Geneva, Switzerland
O'Connor G, Dawson C, Woolford A, Webb KS, Catterick T (2002) Anal Chem 74:3670–3676
Yang I, Han MS, Yim YH, Hwang E, Park SR (2004) Anal Biochem 335:150–161
English CA, Merson S, Keer JT (2006) Anal Chem 78:4630–4633
Holden MJ, Rabb SA, Tewari YB, Winchester MR (2007) Anal Chem 79:1536–1541
Travis JC, Acosta JC, Andor G, Bastie J, Blattner P, Chunnilall CJ, Crosson SC, Duewer DL, Early EA, Hengstberger F, Kim C-S, Liedquist L, Manoocheri F, Mercader F, Metzdorf J, Mito A, Monardh LAG, Nevask S, Nilsson M, Noël M, Rodriguez AC, Ruíz A, Schirmacher A, Smith MV, Valencia G, van Tonder N, Zwinkels J (2005) J Phys Chem Ref Data 34:41-56. See also: SRM 2034 - Holmium Oxide Solution Wavelength Standard from 240 nm to 650 nm, available through http://ts.nist.gov/MeasurementServices/ReferenceMaterials/232.cfm
Burke RW, Mavrodineanu R (1977) NIST Special Publication 260-54. http://ts.nist.gov/MeasurementServices/ReferenceMaterials/upload/SP260-54.pdf See also: SRM 935a - Potassium Dichromate, UV Absorbance Standard and SRM 1935 - Potassium Dichromate Solution for Use as an Ultraviolet Absorbance Standard. Information on these and other NIST reference materials available throughhttp://ts.nist.gov/MeasurementServices/ReferenceMaterials/232.cfm
Acknowledgements
We thank all of the forensic scientists, supervisors, and forensic DNA testing facilities who contributed their expertise, time, and material resources to the interlaboratory assessment. SRM 2372 would not exist except for their encouragement, advice, and willing cooperation with our sometimes seemingly outré requests. The development of SRM 2372 was funded in part by the National Institute of Justice through an interagency agreement with the NIST Office of Law Enforcement Standards.
Disclaimer
Certain commercial equipment, instruments, and materials are identified in order to specify experimental procedures as completely as possible. In no case does such identification imply a recommendation or endorsement by the National Institute of Standards and Technology nor does it imply that any of the materials, instruments, or equipment identified are necessarily the best available for the purpose.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Kline, M.C., Duewer, D.L., Travis, J.C. et al. Production and certification of NIST Standard Reference Material 2372 Human DNA Quantitation Standard. Anal Bioanal Chem 394, 1183–1192 (2009). https://doi.org/10.1007/s00216-009-2782-0
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00216-009-2782-0