Abstract
Purpose
The aim of this study was to clarify the association of the anterior cruciate ligament (ACL) graft bending angle and graft maturity of autograft and allograft tendons using high-resolution MRI.
Methods
Patients with unilateral ACL reconstruction were invited to participate in this study, and they were examined using a 3.0-T MRI scan at 3, 6 and 12 months after the operation. Anatomic single-bundle ACL reconstruction was performed on 48 patients using the trans-portal technique, including 28 with autograft hamstring tendons and 20 with allograft tendons. To evaluate graft healing, the signal/noise quotient (SNQ) was measured in four regions of interest (ROIs) of the femoral tunnel, proximal, midsubstance and distal ACL grafts. The graft bending angle was defined as the angle between the femoral bone tunnel and the line connecting the femoral and tibial tunnel apertures. Graft SNQ and graft bending angle were assessed at 3, 6 and 12 months postoperatively, and the association between SNQ and the average graft bending angle was analyzed.
Results
Generally, the mean graft bending angle of this cohort increased gradually with time. The SNQ value of each graft region increased from 3 to 6 months and then decreased from 6 to 12 months. In the whole cohort, the graft bending angle had a significant positive association with graft SNQ in the femoral tunnel or proximal site. In the allograft subgroup, the graft bending angle had a significant positive association with the graft SNQ in the femoral tunnel or proximal site at 6 months after surgery, while there was no association between the graft bending angle and SNQ at 12 months. In the autograft subgroup, the graft bending angle had a significant positive association with graft SNQ in the femoral tunnel or proximal site at 12 months after surgery.
Conclusion
Generally, the graft bending angle was correlated with a high signal intensity of the proximal graft in the early postoperative period for allograft tendons and in the late postoperative period for allograft tendons. This suggests that the biomechanical effect from the graft bending angle on graft healing may be different for allografts and autografts after ACL reconstruction.
Level of evidence
III.
Similar content being viewed by others
References
Ahn JH, Jeong HJ, Lee YS, Park JH, Lee JH, Ko TS (2016) Graft bending angle is correlated with femoral intraosseous graft signal intensity in anterior cruciate ligament reconstruction using the outside-in technique. Knee 23:666–673
Biercevicz AM, Miranda DL, Machan JT, Murray MM, Fleming BC (2013) In situ, noninvasive, T2*-weighted MRI-derived parameters predict ex vivo structural properties of an anterior cruciate ligament reconstruction or bioenhanced primary repair in a porcine model. Am J Sports Med 41:560–566
Cavaignac E, Marot V, Faruch M, Reina N, Murgier J, Accadbled F, Berard E, Chiron P (2018) Hamstring graft incorporation according to the length of the graft inside tunnels. Am J Sports Med 46:348–356
Chhabra A, Kline AJ, Nilles KM, Harner CD (2006) Tunnel expansion after anterior cruciate ligament reconstruction with autogenous hamstrings: a comparison of the medial portal and transtibial techniques. Arthroscopy 22:1107–1112
Figueroa D, Melean P, Calvo R, Vaisman A, Zilleruelo N, Figueroa F, Villalon I (2010) Magnetic resonance imaging evaluation of the integration and maturation of semitendinosus-gracilis graft in anterior cruciate ligament reconstruction using autologous platelet concentrate. Arthroscopy 26:1318–1325
Fleming BC, Proffen BL, Vavken P, Shalvoy MR, Machan JT, Murray MM (2015) Increased platelet concentration does not improve functional graft healing in bio-enhanced ACL reconstruction. Knee Surg Sports Traumatol Arthrosc 23:1161–1170
Fleming BC, Vajapeyam S, Connolly SA, Magarian EM, Murray MM (2011) The use of magnetic resonance imaging to predict ACL graft structural properties. J Biomech 44:2843–2846
Fu SC, Cheng WH, Cheuk YC, Mok TY, Rolf CG, Yung SH, Chan KM (2013) Effect of graft tensioning on mechanical restoration in a rat model of anterior cruciate ligament reconstruction using free tendon graft. Knee Surg Sports Traumatol Arthrosc 21:1226–1233
Jang KM, Park SC, Lee DH (2016) Graft bending angle at the intra-articular femoral tunnel aperture after single-bundle posterior cruciate ligament reconstruction: inside-out versus outside-in techniques. Am J Sports Med 44:1269–1275
Li H, Chen J, Li H, Wu Z, Chen S (2017) MRI-based ACL graft maturity does not predict clinical and functional outcomes during the first year after ACL reconstruction. Knee Surg Sports Traumatol Arthrosc 25:3171–3178
Li H, Chen S, Tao H, Li H, Chen S (2014) Correlation analysis of potential factors influencing graft maturity after anterior cruciate ligament reconstruction. Orthop J Sports Med 2:2325967114553552
Li H, Tao H, Cho S, Chen S, Yao Z, Chen S (2012) Difference in graft maturity of the reconstructed anterior cruciate ligament 2 years postoperatively: a comparison between autografts and allografts in young men using clinical and 3.0-T magnetic resonance imaging evaluation. Am J Sports Med 40:1519–1526
Muramatsu K, Hachiya Y, Izawa H (2008) Serial evaluation of human anterior cruciate ligament grafts by contrast-enhanced magnetic resonance imaging: comparison of allografts and autografts. Arthroscopy 24:1038–1044
Natsu-ume T, Shino K, Nakata K, Nakamura N, Toritsuka Y, Mae T (2001) Endoscopic reconstruction of the anterior cruciate ligament with quadrupled hamstring tendons. A correlation between MRI changes and restored stability of the knee. J Bone Jt Surg Br 83:834–837
Niki Y, Nagai K, Harato K, Suda Y, Nakamura M, Matsumoto M (2017) Effects of femoral bone tunnel characteristics on graft-bending angle in double-bundle anterior cruciate ligament reconstruction: a comparison of the outside-in and transportal techniques. Knee Surg Sports Traumatol Arthrosc 25:1191–1198
Nishimoto K, Kuroda R, Mizuno K, Hoshino Y, Nagamune K, Kubo S, Yagi M, Yamaguchi M, Yoshiya S, Kurosaka M (2009) Analysis of the graft bending angle at the femoral tunnel aperture in anatomic double bundle anterior cruciate ligament reconstruction: a comparison of the transtibial and the far anteromedial portal technique. Knee Surg Sports Traumatol Arthrosc 17:270–276
Tashiro Y, Gale T, Sundaram V, Nagai K, Irrgang JJ, Anderst W, Nakashima Y, Tashman S, Fu FH (2017) The graft bending angle can affect early graft healing after anterior cruciate ligament reconstruction: in vivo analysis with 2 years’ follow-up. Am J Sports Med 45:1829–1836
Tashiro Y, Irarrazaval S, Osaki K, Iwamoto Y, Fu FH (2017) Comparison of graft bending angle during knee motion after outside-in, trans-portal and trans-tibial anterior cruciate ligament reconstruction. Knee Surg Sports Traumatol Arthrosc 25:129–137
Tashiro Y, Sundaram V, Thorhauer E, Gale T, Anderst W, Irrgang JJ, Fu FH, Tashman S (2017) In vivo analysis of dynamic graft bending angle in anterior cruciate ligament-reconstructed knees during downward running and level walking: comparison of flexible and rigid drills for transportal technique. Arthroscopy 33:1393–1402
Tomihara T, Hashimoto Y, Taniuchi M, Shimada N (2015) Relationship between femoral tunnel location and graft bending angle in outside-in and transportal technique for ACL double bundle reconstruction in 3D-CT study. Arch Orthop Trauma Surg 135:839–846
Unterhauser FN, Bail HJ, Hoher J, Haas NP, Weiler A (2003) Endoligamentous revascularization of an anterior cruciate ligament graft. Clin Orthop Relat Res 414:276–288
Wang JH, Kim JG, Lee DK, Lim HC, Ahn JH (2012) Comparison of femoral graft bending angle and tunnel length between transtibial technique and transportal technique in anterior cruciate ligament reconstruction. Knee Surg Sports Traumatol Arthrosc 20:1584–1593
Yoshikawa T, Tohyama H, Enomoto H, Matsumoto H, Toyama Y, Yasuda K (2006) Expression of vascular endothelial growth factor and angiogenesis in patellar tendon grafts in the early phase after anterior cruciate ligament reconstruction. Knee Surg Sports Traumatol Arthrosc 14:804–810
Funding
No funding.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
The authors report no conflict of interest.
Ethical approval
The Health Sciences Institutional Review Board of our hospital approved this study (the Ethics Committee of Ningbo First Hospital, Approval number 2013-0110).
Rights and permissions
About this article
Cite this article
Chen, L., Wu, Y., Lin, G. et al. Graft bending angle affects allograft tendon maturity early after anterior cruciate ligament reconstruction. Knee Surg Sports Traumatol Arthrosc 26, 3048–3054 (2018). https://doi.org/10.1007/s00167-018-4910-x
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00167-018-4910-x