To investigate the validity and accuracy of tissue Doppler imaging (TDI) using a novel balloon phantom, validation of TDI myocardial velocity measurements has been carried out indirectly from conventional M-mode images. However it is not a true and independent gold standard. We described a new TDI validation method by using a specially developed left ventricular balloon model mounted in a water bath and constructed using two pear-shaped balloons. It was connected to a pulsatile flow pump at 8 stroke volumes (50–85 ml/beat). The displacement and velocity of the balloon walls were recorded simultaneously by video imaging and TDI on a GE-Vingmed System Five with a 5 MHz phased array probe at the highest frame rates available. Conventional M-mode and 2-D imaging verified that our balloon model mimicked the shape and wall motion of left ventricle. There was a good correlation and agreement between the maximum video excursion of the anterior and posterior walls of the phantom and the results of the temporal integration of digital distance data by TDI (Anterior wall: r=0. 97, SEE=0. 24 mm,x± s=0. 04±0. 24 mm; Posterior wall: r=0. 95, SEE = 0. 22 mm, −x±s−0. 03±0. 24 mm). Analysis of the velocity profile by the TDI method showed that the velocity at each measured point was correlated well with the velocity obtained from the video images (Anterior wall: r=0. 97, SEE = 0. 30 mm, −x±s= 0. 04±0. 28 mm; Posterior wall: r=0. 97, SEE = 0. 30 mm, −x±s = 0. 04 + 0. 28 mm). Our balloon model provided a new independent method for the validation of TDI data. This study demonstrated that the present TDI system is reliable for measuring wall motion distance and velocity.
Similar content being viewed by others
References
Miyatake K, Yamagishi M, Tanaka Net al. New method for evaluating left ventricular wall motion by color-coded tissue Doppler imaging: In vitro and in vivo studies. JACC, 1995, 25(3):717
McDicken W N, Sutherland G R, Moran C Met al. Color Doppler velocity imaging of the myocardium. Ultrasound Med Biol, 1992, 18:654
Bland J M, Altman D G. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet, 1986, 1(8476):307
Uematsu M, Miyatake K, Tanaka Net al. Myocardial velocity gradient as a new indicator of regional left ventricular contraction: Detection by a two-dimensional tissue Doppler imaging technique. JACC, 1995, 26(1):217
Ohte N, Narita H, Hashimoto Tet al. Evaluation of left ventricular early diastolic performance by color tissue Doppler imaging of the mitral annulus. Am J Cardiol, 1998, 82(11):1414
Gorcsan J, Deswal A, Mankad Set al. Quantification of the myocardial response to low-dose dobutamine using tissue Doppler echocardiographic measures of velocity and velocity gradient. Am J Cardiol, 1998, 81(5): 615
Nagueh S F, Mikati I, Kopelen H Aet al. Doppler estimation of left ventricular filling pressure in sinus tachycardia. A new application of tissue Doppler imaging. Circulation, 1998, 98(16):1644
Gorcsan J, Strum D P, Mandarino W Aet al. Quantitative assessment of alterations in regional left ventricular contractility with color-coded tissue Doppler echocardiography. Comparison with sonomicrometry and pressurevolume relations. Circulation, 1997, 95(10):2123
Abe M, Oki T, Tabata Tet al. Difference in the diastolic left ventricular wall motion velocities between aortic and mitral regurgitation by pulsed tissue Doppler imaging. J Am Soc Echocardiogr, 1999, 12(1):15
Oki T, Iuchi A, Tabata Tet al. Left ventricular systolic wall motion velocities along the long and short axes measured by pulsed tissue Doppler imaging in patients with atrial fibrillation. J Am Soc Echocardiogr, 1999, 12(2): 121
Galiuto L, Ignone G, Demaria A N. Contraction and relaxation velocities of the normal left ventricle using pulsed-wave tissue Doppler echocardiography. Am J Cardiol, 1998, 81(5)609
Bartel T, Muller S, Schurger Det al. Quantitative tissue Doppler echocardiography in comparison with Mmode measurements in health probands. Zeitschrift fur Kardiologie, 1997, 86(2): 131
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Ying, W., Irvine, T., Mori, Y. et al. In Vitro validation of tissue doppler left ventricular regional wall velocities by using a novel balloon phantom. Current Medical Science 21, 337–340 (2001). https://doi.org/10.1007/BF02886574
Received:
Published:
Issue Date:
DOI: https://doi.org/10.1007/BF02886574