Abstract
The availability of on-site methods of diagnosis of the deterioration rate in reinforced concrete structures is a pressing technical need all over the world. Two new methods are proposed in this paper which are derived from the polarization resistance method, but which, differing from this method, are applicable to full-size structures, in spite of the non-uniform distribution of the electric signals in them. The two proposed procedures are of a simplicity and reliability comparable with those offered by direct measurement of polarization resistance.
Resume
Le besoin pressant se fait sentir partout dans le monde de disposer de méthodesin situ pour détecter le taux de détérioration dans les constructions en béton armé. Dans cet article, on propose deux nouvelles méthodes dérivées de la méthode de résistance de polarisation, mais qui diffèrent de celle-ci en ce qu’elles peuvent s’appliquer aux structures elles-mêmes, malgré la distribution non uniforme des signaux électriques dans ces dernières. Les deux méthodes proposées sont d’une simplicité et d’une sûreté comparables à celles offertes par la mesure directe de résistance de polarisation.
Similar content being viewed by others
References
Feliu, S., González, J. A., Andrade, C. and Feliu, V., ‘On-site determination of the polarization resistance in a reinforced concrete beam’,Corrosion 44(10) (1988) 761–765.
Idem., ‘Posibilidades de estimar la velocidad instantánea de corrosión en estructuras reales de hormigón armado. Caso de una viga,’Rev. Iberoam. Corros. Prot. 18(2–6) (1987) 177–183.
Idem., ‘Determining polarization resistance in reinforced concrete slabs,’Corros. Sci. 29(19) (1989) 105–113.
Feliu, S., González, J. A., Andrade, C., Escudero, M. L. and Macias, A., ‘Posibilidades de estimar la velocidad instantánea de corrosión en estructuras reales de hormigón armado. Caso de un tablero’, in Proceedings of COLLOQUIA 88, IETcc-CEDEX, Madrid, May 1988, Vol. 2, pp. 5–22.
Stern, M. and Geary, A. L., ‘A theoretical analysis of the shape of polarization curves,’J. Electrochem. Soc. 104(1) (1957) 56–63.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Gonzalez, J.A., Feliu, S., Andrade, C. et al. On-site detection of corrosion in reinforced concrete structures. Materials and Structures 24, 346–350 (1991). https://doi.org/10.1007/BF02472067
Issue Date:
DOI: https://doi.org/10.1007/BF02472067