Skip to main content
Log in

Effect of electrode size on the contributions of intracranial and extracranial blood flow to the cerebral electrical impedance plethysmogram

  • Published:
Medical and Biological Engineering and Computing Aims and scope Submit manuscript

Abstract

The contribution of scalp blood flow to pulses obtained by cerebral electrical impedance plethysmography (rheoencephalography) has been investigated using a four-electrode (quadripolar) montage with brass disc electrodes 1 cm, 2 cm and 4 cm in diameter. Three states of scalp perfusion were produced by the application of a tourniquet around the occipto-frontal circumference of the head, and blood flow in the scalp was monitored by means of reflection photoplethysmography and an electrical impedance technique. When scalp perfusion was occluded, cerebral impedance pulse amplitude was reduced to 80% of that obtained during normal scalp flow; in the presence of maximal scalp flow as a result of the reactive hyperaemia induced by release of the tourniquet, cerebral impedance pulse amplitude was 30% greater than during normal scalp flow. Altering electrode diameter did not affect the contribution of scalp flow to cerebral impedance pulse size. The effect of changes in scalp flow did, however, increase when a bipolar electrode montage was used instead of a quadripolar montage.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

References

  • Costeloe, K. andRolfe, P. (1980) Continuous limb blood flow estimation in the newborn using electrical impedance plethysmography,Pediatr. Res.,14, 1053–1060.

    Google Scholar 

  • Hadjiev, D. (1968) A new method for quantitative evaluation of cerebral blood flow by rheoencephalography.Brain Res.,8, 213–215.

    Article  Google Scholar 

  • James, I. M. (1979) Methods for assessment of the effect of drugs on cerebral blood flow in man.Br. J. Clin. Pharmacol.,7, 3–12.

    Google Scholar 

  • Lifshitz, K. (1970) Electrical impedance cephalography, electrode guarding and analog studies.Ann. N.Y. Acad. Sci.,170, 532–549.

    Google Scholar 

  • Markovich, S. E. andNamon, R. (1970) Monopolar rheoencephalography.Ann. N.Y. Acad. Sci.,170, 652–660.

    Google Scholar 

  • McHenry, L. C. (1965) Rheoencephalography—a clinical appraisal.Neurology,15, 507–517.

    Google Scholar 

  • Murdoch, N., Murray, P. W., Rolfe, P. andWeindling, A. M. (1981) Computer modelling of cerebral electrical impedance in the newborn baby for comparison within vivo measurements. In Proceedings of 5th Nordic Medical and Biological Engineering Conference, Sweden.

  • Perez-Borja, C. andMeyer, J. S. (1964) A critical evaluation of rheoencephalography in control subjects and in proven cases of cerebrovascular disease.J. Neurol. Neurosurg. Psychiatry,27, 66–72.

    Article  Google Scholar 

  • Rolfe, P. (1979) Theoretic aspects of skin blood flow estimation using thermal, optical and impedance techniques.Birth Defects,15, 135–147.

    Google Scholar 

  • Salter, D. C. (1979) Quantifying skin disease and healingin vivo using electrical impedance measurements. InNoninvasive physiological measurements,Rolfe,P. (Ed.), Academic Press, London.

    Google Scholar 

  • Seipel, J. H. (1970) The influence of electrode size and material on the rheoencephalogram.Ann. N.Y. Acad. Sci.,170, 604–621.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Weindling, A.M., Murdoch, N. & Rolfe, P. Effect of electrode size on the contributions of intracranial and extracranial blood flow to the cerebral electrical impedance plethysmogram. Med. Biol. Eng. Comput. 20, 545–549 (1982). https://doi.org/10.1007/BF02443401

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02443401

Keywords

Navigation