Abstract
Blood pressures in the temporal artery of five normotensive subjects were recorded using a modified auscultatory setup. The setup comprised a pediatric cuff to occlude the artery and a piezoelectric contact microphone to record the Korotkoff sounds. Both the cuff and microphone were held in their respective positions with an adjustable head band. The recordings were taken under four different conditions: the subject lying supine, the subject sitting at rest, the subject sitting immediately after exercise and the subject moving the head gently. These recordings were compared with readings from the brachial artery, obtained with a commercially available automatic blood pressure measuring device. Korotkoff sounds were analyzed in the time and frequency domain. Results indicate that Korotkoff sounds in the temporal artery are much smaller in amplitude, and do not exhibit the same distinctive phases as those of the brachial artery. Despite these differences, these sounds can be used to detect blood pressures at head level. The accuracy of the readings was within ±10%. Successful readings were also obtained with gentle head motions, demonstrating that this setup has the potential to be developed into an ambulatory blood pressure monitoring system.
Similar content being viewed by others
References
Drzewiecki, G.M.; Melbin, J.; Noordergraaf, A. The Korotkoff sound. Ann. Biomed. Eng. 17:325–359; 1989.
Fukuoka, M.; Yamori, Y.; Ueno, T.; Kodama, S.; Parati, G.; Pomidossi, G.; Mancia, G.; Zanchetti, A. Evaluation of a new non-invasive semiautomatic blood pressure monitoring device. Clin. and Exper. Theory and Practice A9:141–152; 1987.
Geddes, L.A. The direct and indirect measurement of blood pressure. Chicago: Year Book Medical Publishers, Inc.; 1970.
Goodman, E.H.; Howell, A.A. Further clinical studies in the auscultatory method of determining blood pressure. Am. J. M. Sc. 142:334–352; 1911.
Karr, S.G.; Karwoski, T.; Jacobs, J.E.; Mockros, L.F. Transducer system for the noninvasive recording of arterial pressure contours. Ann. Biomed. Eng. 13:425–442; 1985.
Kobayashi, H.; Shimazu, H.; Kawarada, A.; Ito, C. Indirect measurement of eye-level arterial pressure by the oscillometric method. J. Clin. Eng. 15:195–204; 1990.
Korotkoff, N.S. On methods of studying blood pressure. Bull. Imperial Mil. Med. Acad., St. Petersburg 11:365; 1905.
Krutz, R.W.; Rositano, S.A.; Mancini, R.E. Comparison of techniques for measuring +Gz tolerance in man. J. Appl. Physiol. 38:1143–1145; 1975.
LaCourse, J.R.; Sivaprasad, K.; Rogers, D.B. A system to measure a pilot's temporal pulse pressure during acceleration. Aviat. Space Environ. Med. 62:356–362; 1991.
Maurer, A.H.; Noordergraaf, A. Korotkoff sound filtering for automated three phase measurement of blood pressure. Am. Heart J. 91:584–591; 1976.
Oppenheim, A.V.; Schafer, R.W. Digital signal processing. Prentice Hall; Englewood Cliffs, NJ: 1975: p. 242.
Pressman, G.L.; Newgard, P.M. Development of a blood-pressure transducer for the temporal artery. national Aeronautics and Space Administration, Contract #NAS2-1332, Stanford Research Institute; 1963.
Pressman, G.L.; Newgard, P.M. A transducer for the continuous external measurement of arterial blood pressure. IEEE Trans. Biomed. Electronics BME-10:73–81; 1963.
Tavel, M.E.; Faris, J.; Nasser, W.K.; Feigenbaum, H.; Fisch, C. Korotkoff sounds, observations on pressure-pulse changes underlying their formation. Circulation 39:465–474; 1969.
Thiagarajah, S.; Girnar, D.S.; Park, K.Y. Blood pressure monitoring using the superficial temporal artery and a Doppler ultrasonic flow detector. J. Anesth. Analg. 58:526–527 1979.
Ware, R.W.; Anderson, W.L. Spectral analysis of Korotkoff sounds. IEEE Trans. Biomed. Eng. BME 13:170–174; 1966.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Shenoy, D., von Maltzahn, W.W. & Buckey, J.C. Noninvasive blood pressure measurement on the temporal artery using the auscultatory method. Ann Biomed Eng 21, 351–360 (1993). https://doi.org/10.1007/BF02368627
Issue Date:
DOI: https://doi.org/10.1007/BF02368627