Skip to main content
Log in

Comparison of two cool vests on heat-strain reduction while wearing a firefighting ensemble

  • Original Article
  • Published:
European Journal of Applied Physiology and Occupational Physiology Aims and scope Submit manuscript

Abstract

This study evaluated the effectiveness of a six-pack versus a four-pack cool vest in reducing heat strain in men dressed in firefighting ensemble, while resting and exercising in a warm/humid environment [34.4°C (day bulb), 28.9°C (wet bulb)]. Male volunteers (n = 12) were monitored for rectal temperature (T re), mean skin temperature (T sk), heart rate, and energy expenditure during three test trials: control (no cool vest), four-pack vest, and six-pack vest. The cool vests were worn under the firefighting ensemble and over Navy dungarees. The protocol consisted of two cycles of 30 min seated rest and 30 min walking on a motorized treadmill (1.12 m · s−1, 0% grade). Tolerance time for the control trial (93 min) was significantly less than both vest trials (120 min). Throughout heat exposure, energy expenditure varied during rest and exercise, but no differences existed among all trials (P > 0.05). During the first 60 min of heat exposure, physiological responses were similar for the four-pack and six-pack vests. However, during the second 60 min of heat exposure the six-pack vest had a greater impact on reducing heat strain than the four-pack vest. PeakT e andT sk at the end of heat exposure for 6-pack vest [mean (SD) 38.0(0.3)°C and 36.8(0.7)°C] were significantly lower compared to four-pack [38.6 (0.4)°C and 38.1(0.5)°C] and controls [38.9(0.5)°C and 38.4(0.5)°C]. Our findings suggest that the six-pack vest is more effective than the four-pack vest at reducing heat strain and improves performance of personnel wearing a firefighting ensemble.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

References

  • Banto G, Braun D (1992) Heat Strain during at-sea helicopter operations and the effect of passive microclimate cooling. Aviat Space Environ Med 63:881–885

    Google Scholar 

  • Bennett B, Hagan R, Banta G, Williams F (1992) Physiological responses during shipboard firefighting. Aviat Space Environ Med 63:68

    Google Scholar 

  • Carpenter T (1964) Tables, factors, an formulas for computing respiratory exchange and biological transformations of energy. Carnegie Institution of Washington Publication 303C, Washington, D.C.

    Google Scholar 

  • Craig FN, Garren HW, Frankel H, Blevins WV (1954) Heat load and voluntary tolerance time. J Appl Physiol 6:634–644

    Google Scholar 

  • Duncan H, Gardner G, Barnard R (1979) Physiological responses of men working in fire fighting equipment in the heat. Erogonomics 22:521–527

    Google Scholar 

  • Eichna LW, Park CR, Nelson N, Horvath SM, Palmas ED (1950) Thermal regulation during acclimatization in a hot, dry (desert, type) environment. Am J Physiol 163:585–597

    Google Scholar 

  • Henane R, Bittel R, Viret R, Morine S (1979) Thermal strain result ing from protective clothing of an armored vehicle crew in warm conditions. Aviat Space Environ Med 50:599–603

    Google Scholar 

  • Hodgdon JA, Beckett MB (1984) Prediction of percent body fat for U.S. Navy men from body circumferences and height. Naval Health Research Center Technical Repot 11

  • Janik C, Avellini B, Pimental N (1987) Microclimate cooling systems: shipboard evaluation of commercial models. NCTRF Tech Rep 163

  • Kaufman WC (1963) Human tolerance limits for some thermal environments of Aerospace. Aerospace Med 34:889–896

    Google Scholar 

  • Muza S, Pimental N, Cosimini H, Sawka M (1988) Portable, ambit ent air microclimate cooling in simulated desert and tropic conditions. Aviat Space Environ Med 59:553–558

    Google Scholar 

  • Nadel E, Cafarelli E, Roberts M, Wenger C (1979) Circulatory regulation during exercise in different ambient temperatures. J Appl Physiol 46:430–437

    Google Scholar 

  • Nunneley S, Antunano M, Bomalaski S (1992) Thermal convergence, fails to predict heat tolerance limits. Aviat Space Environ Med 63:886–890

    Google Scholar 

  • Pandolf K, Gloldman R (1978) Convergence of skin and rectal temperatures as a criterion for heat tolerance. Aviat Space Environ Med 49:1095–1101

    Google Scholar 

  • Pimental N, Avellini B, Banderet L (1991) Comparison of heat stress when the Navy fire fighters ensemble is worn in various configurations. Navy Clothing and Textile Research Facility and U.S. Army Research Institute of Environmental Medicine. Technical report no. NCTRF 192

  • Ramanathan N (1964) A new weighing system for mean surface temperatures of the human body. J Appl Physiol 21:1757–1762

    Google Scholar 

  • Romet T, Frim J (1987) Physiological responses to fire fighting activities. Eur J Appl Physiol 56:633–638

    Google Scholar 

  • Rowell L (1983) Cardiovascular aspect of human thermo-regulation. Circ Res 52: 367–379

    Google Scholar 

  • Shvartz E, Benor D (1972) Heat strain in hot and humid environments. Aerospace Med 43: 852–855

    Google Scholar 

  • Speckman K, Allan A, Sawka M, Young A, Muza S, Pandolf K (1988) Perspectives in microclimate cooling involving protective clothing in hot environments. Int J Ind Ergon 3: 121–147

    Google Scholar 

  • Stolwijk J, Hardy J (1966) Partitional calorimetric studies of responses of man to thermal transients. J Appl physiol 21: 967–977

    Google Scholar 

  • Terrian D, Nunneley S (1983) A laboratory comparison of portable cooling systems for workers exposed to two levels of heat stress. USAFSAM Tech Rep 83-14

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Bennett, B.L., Hagan, R.D., Huey, K.A. et al. Comparison of two cool vests on heat-strain reduction while wearing a firefighting ensemble. Europ. J. Appl. Physiol. 70, 322–328 (1995). https://doi.org/10.1007/BF00865029

Download citation

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00865029

Key words

Navigation