J Korean Acad Conserv Dent. 2003 Nov;28(6):457-466. Korean.
Published online Nov 30, 2003.
Copyright © 2003 Korean Academy of Conservative Dentistry
Original Article

The effect of viscosity, specimen geometry and adhesion on the linear polymerization shrinkage measurement of light cured composites

In-Bog Lee, Ho-Hyun Son, Hyuk-Chun Kwon, Chung-Moon Um and Byeong-Hoon Cho
    • Department of Conservative Dentistry, College of Dentistry, Seoul National University, Korea.

This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.

Abstract

Objectives

The aim of study was to investigate the effect of flow, specimen geometry and adhesion on the measurement of linear polymerization shrinkage of light cured composite resins using linear shrinkage measuring device.

Methods

Four commercially available composites - an anterior posterior hybrid composite Z100, a posterior packable composite P60 and two flowable composites, Filtek flow and Tetric flow - were studied. The linear polymerization shrinkage of composites was determined using 'bonded disc method' and 'non-bonded' free shrinkage method at varying C-factor in the range of 1~8 by changing specimen geometry. These measured linear shrinkage values were compared with free volumetric shrinkage values.

The viscosity and flow of composites were determined and compared by measuring the dropping speed of metal rod under constant load.

Results

In non-bonded method, the linear shrinkage approximated one third of true volumetric shrinkage by isotropic contraction. However, in bonded disc method, as the bonded surface increased the linear shrinkage increased up to volumetric shrinkage value by anisotropic contraction. The linear shrinkage value increased with increasing C-factor and approximated true volumetric shrinkage and reached plateau at about C-factor 5~6. The more flow the composite was, reduced linear shrinkage was measured by compensation radial flow.

Keywords
Anisotropy; Polymerization shrinkage; Bonded disc method; Flow; C-factor; Light cured composites

Figures

Fig. 1-a
The structure of instrument to measure linear shrinkage.

Fig. 1-b
The geometry of composite specimen sandwiched between two glass plates. Polymerization shrinkage creates axial (vertical) and radial (horizontal) contraction of the specimen.

Fig. 2
Linear polymerization shrinkage curves of composites as a function of time at C-factor ≈ 6.

Fig. 3
Linear polymerization shrinkage of composites measured using bonded disc method. The linear shrinkage value increased with increasing C-factor and approximated volumetric shrinkage and reached plateau at about C-factor 5~6.

a) Linear shrinkage of Z1 as a function of C-factor.

b) Linear shrinkage of P6 as a function of C-factor.

c) Liner shrinkage of FF as a function of C-factor.

d) Linear shrinkage of TF as a function of C-factor.

Fig. 4
Linear polymerization shrinkage of composites measured using non-bonded disc method with Vaseline. The linear shrinkage is not affected by specimen diameter and is approximated the theoretical linear shrinkage value calculated from true volumetric shrinkage value.

a) Linear shrinkage of Z1 as a function of specimen geometry.

b) Linear shrinkage of P6 as a function of specimen geometry.

c) Liner shrinkage of FF as a function of specimen geometry.

d) Linear shrinkage of TF as a function of specimen geometry.

Fig. 5
Peak time (peak shrinkage rate time) of Z1 as a function of C-factor.

Fig. 6
Relative viscosity of composites based on flow normalized to Z1.

Tables

Table 1
Materials used in this study

Table 2
Volumetric polymerization shrinkage and linear shrinkage of composite resins at varying C-factor

Table 3
Cure speed based on Peak Time (P.T.) of composites at varying C-factor

Table 4
Consistency (viscosity) based on the flow of composite resins

References

    1. Lai JH, Johnson AE. Measuring polymerization shrinkage of photo activated restorative materials by a water filled dilatometer. Dent Mater 1993;9:139–143.
    1. Sakaguchi RL, Sasik CT, Bunczak MA, Douglas WH. Strain gauge method for measuring polymerization contraction of composite restoratives. J Dent 1991;19:312–316.
    1. Penn RW. A recording dilatometer for measuring polymerization shrinkage. Dent Mater 1986;2:78–79.
    1. Rees JS, Jacobsen PH. The polymerization shrinkage of composite resins. Dent Mater 1989;5:41–44.
    1. Sakaguchi RL, Berghe HX. Reduced light energy density decreases post gel contraction while maintaining degree of conversion in composites. J Dent 1998;26:695–700.
    1. Suh BI, Feng L, Wang Y, Cripe C, Cincione F, de Rjik W. The effect of the pulse delay cure technique on residual strain in composites. Compend Contin Educ Dent 1999;20 2 Suppl:4–14.
    1. Silikas N, Eliades G, Watts DC. Light intensity effects on resin composite degree of conversion, shrinkage strain. Dent Mater 2000;16:292–296.
    1. Cook WD, Forrest M, Goodwin AA. A simple method for the measurement of polymerization shrinkage in dental composites. Dent Mater 1999;15:447–449.
    1. Puckett AD, Smith R. Method to measure the polymerization shrinkage of light cured composites. J Prosthet Dent 1992;68:56–58.
    1. de Gee AJ, Feilzer AJ, Davidson CL. True linear polymerization shrinkage of unfilled resins, composites determined with a linometer. Dent Mater 1993;9:11–14.
    1. Venhoven BAM, de Gee AJ, Davidson CL. Polymerization contraction, conversion of light-curing BisGMA-based methacryate resins. Biomaterials 1993;14(11):871–875.
    1. Feilzer AJ, de Gee AJ, Davidson CL. Curing contraction of composites, glass ionomer cements. J Prosthet Dent 1988;59:297–300.
    1. Fano V, Ortalli I, Pizzi S, Bonanini M. Polymerization shrinkage of microfilled composites determined by laser beam scanning. Biomaterials 1997;18:467–470.
    1. Watts DC, Marouf AS. Optimal specimen geometry in bonded-disc shrinkage-strain measurements on light-cured biomaterials. Dent Mater 2000;16:447–451.
    1. Watts DC, Cash AJ. Determination of polymerization shrinkage kinetics in visible-light-cured materials: methods development. Dent mater 1991;7:281–287.
    1. Feilzer AJ, de Gee AJ, Davidson CL. Increased wall-to-wall curing contraction in thin bonded resin layers. J Dent Res 1989;68:48–50.
    1. Lee IB. A new method - Real time measurement of the initial dynamic volumetric shrinkage of composite resins during polymerization. J Korean Acad Conserv Dent 2001;26:134–140.
    1. Opdam NJM, Roeters JJM, Peters TCRB, et al. Consistency of resin composites for posterior use. Dent Mater 1996;12:350–354.
    1. Bayne SC, Thompson JY, Swift EJ, et al. A characterization of first-generation flowable composites. JADA 1998;129:567–577.
    1. Labella R, Lambrechts P, van Meerbeek B, Vanherle G. Polymerization shrinkage, elasticity of flowable composites, filled adhesives. Dent Mater 1999;15:128–137.
    1. Lee IB, Son HH, Um CM. Rheologic properties of flowable, conventional hybrid, condensable composite resins. Dent Mater 2003;19:298–307.
    1. Tyas MJ, Jones DW, Rizkalla AS. The evaluation of resin composite consistency. Dent Mater 1998;14:424–428.
    1. Feilzer AJ, de Gee AJ, Davidson CL. Setting stress in composite resin in relation to configuration of the restoration. J Dent Res 1987;66:1636–1639.
    1. Watts DC, Al Hindi A. Intrinsic 'soft-start' polymerization shrinkage kinetics in a acrylate-based resin composite. Dent Mater 1999;15:39–45.
    1. Barnes HA, Hutton JF, Walters K. In: An introduction to rheology. 1st ed. Amsterdam: Elsevier Science Publishing co; 1989.

Metrics
Share
Figures

1 / 7

Tables

1 / 4

PERMALINK