Journal List > J Korean Med Assoc > v.50(1) > 1041915

Chung: MDCT Application of Thoracic Imaging

Abstract

Multidetector-row computed tomography (MDCT) provides new opportunities and poses challenges for medical imaging to radiologists and physicians. Isotropic imaging (similar resolution in three dimensional directions) allows in-depth views of anatomy and disease. Ultra-fast scan enables whole-body volume imaging within a single breath hold and thus the reduction of contrast medium consumption. CT volume data sets can be used for three-dimensional visualization of the whole body, with which the detailed and comprehensive interpretation of thoracic anatomy and specific disease location and extent is plausible. Moreover, four-dimensional CT imaging can be possible and therefore, we can observe and quantify cardiopulmonary functions without invasive procedures. The author reviews briefly the application of MDCT for the thoracic imaging.

Figures and Tables

Figure 1
Comparison of multiplanar image reformatted from conventional CT and MDCT
(A) Coronal reformatted image from single spiral CT with 5mm thick axial image
(B) Coronal reformatted image from sixteen multidetector-row CT with 1.25mm thick axial image
jkma-50-57-g001
Figure 2
Comparison of pixel and voxel. One pixel of axial CT has 0.5 × 0.5 mm size on XY plan. However Z axis length of this pixel on three dimensions is long to 10mm. This voxel shows unusually long hexahedron
jkma-50-57-g002
Figure 3
How long scan with 1 mm slices thickness in 30 second scan time?
jkma-50-57-g003
Figure 4
Diagram of penumbra effect
jkma-50-57-g004
Figure 5
Diagram of beam transmission with traditional axial scan vs. cone beam scan of MDCT
jkma-50-57-g005
Figure 6
Comprehensive interpretation of anatomy using multiplanar image
(A) Plain radiography shows calcified granuloma in right upper lung zone (arrow)
(B) Coronal reformatted image of MDCT shows similar view with (A) It shows calcified granuloma also and fibrotic bands in right upper lobe as an additional finding (arrows)
jkma-50-57-g006
Figure 7
Pulmonary thromboembolism on multplanar CT angiography. Filling defect (arrow) in right inferior pulmonary artery is conspicuous within highly enhanced vascular structure
(A) Axial image (B) Coronal image (C) Sagital image
jkma-50-57-g007
Figure 8
Virtual bronchography using three dimensional volume rendering technique. Tubular structures with high (virtual) enhancement in right upper lobe and left lower lobe (arrows) are tubular bronchiectasis
jkma-50-57-g008
Figure 9
Enhancement dynamic CT of pulmonary nodule. Serial images obtained at 30-second intervals and at similar levels show enhancement dynamics of nodule. We can extract objective attenuation of nodule and plot time-attenuation curve
jkma-50-57-g009

References

1. Taguchi K, Aradate H. Algorithm for image reconstruction in multi-slice helical CT. Med Phys. 1998. 25:550–561.
crossref
2. De Smedt E, Potvliege R, Pimontel-Appel B, Claus E, Vignaud J. High resolution CT-scan of the temporal bone; a preliminary report. J Belge Radiol. 1980. 63:205–212.
3. Todo G, Herman PG. High-resolution computed tomography of the pig lung. Invest Radiol. 1986. 21:689–696.
crossref
4. Kohler T, Proksa R, Bontus C, Grass M, Timmer J. Artifact analysis of approximate helical cone-beam CT reconstruction algorithms. Med Phys. 2002. 29:51–64.
crossref
5. Zou Y, Sidky EY, Pan X. Partial volume and aliasing artefacts in helical cone-beam CT. Phys Med Biol. 2004. 49:65–75.
crossref
6. Yang K, Kwan AL, Miller DF, Boone JM. A geometric calibration method for cone beam CT systems. Med Phys. 2006. 33:1695–1706.
crossref
7. Mori S, Endo M, Kondo C, Tanada S. Physical evaluation of the weighted Feldkamp algorithms applied to the 256-detector row CT scanner for volumetric cine imaging. Acad Radiol. 2006. 13:701–712.
crossref
8. Schmidt TG, Fahrig R, Pelc NJ. A three-dimensional reconstruction algorithm for an inverse-geometry volumetric CT system. Med Phys. 2005. 32:3234–3245.
crossref
9. Remy J, Remy-Jardin M, Artaud D, Fribourg M. Multiplanar and three-dimensional reconstruction techniques in CT: impact on chest diseases. Eur Radiol. 1998. 8:335–351.
crossref
10. Studler U, Gluecker T, Bongartz G, Roth J, Steinbrich W. Image quality from high-resolution CT of the lung: comparison of axial scans and of sections reconstructed from volumetric data acquired using MDCT. AJR Am J Roentgenol. 2005. 185:602–607.
crossref
11. Sung YM, Lee KS, Yi CA, Yoon YC, Kim TS, Kim S. Additional coronal images using low-milliamperage multidetector-row computed tomography: effectiveness in the diagnosis of bronchiectasis. J Comput Assist Tomogr. 2003. 27:490–495.
crossref
12. Chung MJ, Lee JH, Lee KS, Yoon YC, Kwon OJ, Kim TS. Bronchial and nonbronchial systemic arteries in patients with hemoptysis: depiction on MDCT angiography. AJR Am J Roentgenol. 2006. 186:649–655.
crossref
13. Yoon YC, Lee KS, Jeong YJ, Shin SW, Chung MJ, Kwon OJ. Hemoptysis: bronchial and nonbronchial systemic arteries at 16-detector row CT. Radiology. 2005. 234:292–298.
crossref
14. Carraro M, Malalan F, Antonione R, Stacul F, Cova M, Petz S, Assante M, Grynne B, Haider T, Palma LD, Faccini L. Effects of a dimeric vs a monomeric nonionic contrast medium on renal function in patients with mild to moderate renal insufficiency: a double-blind, randomized clinical trial. Eur Radiol. 1998. 8:144–147.
crossref
15. Spataro RF, Fischer HW, Kormano M. Clinical comparison of Hexabrix, iopamidol, and urografin-60 in whole body computed tomography. Invest Radiol. 1984. 19:372–375.
crossref
16. Donadio C, Tramonti G, Lucchesi A, Giordani R, Lucchetti A, Bianchi C. Tubular toxicity is the main renal effect of contrast media. Ren Fail. 1996. 18:647–656.
crossref
17. Bae KT. Peak contrast enhancement in CT and MR angiography: when does it occur and why? Pharmacokinetic study in a porcine model. Radiology. 2003. 227:809–816.
crossref
18. Bae KT, Heiken JP, Brink JA. Aortic and hepatic peak enhancement at CT: effect of contrast medium injection rate--pharmacokinetic analysis and experimental porcine model. Radiology. 1998. 206:455–464.
crossref
19. Jeong YJ, Lee KS, Yoon YC, Kim TS, Chung MJ, Kim S. Evaluation of small pulmonary arteries by 16-slice multidetector computed tomography: Optimum slab thickness in condensing transaxial images converted into maximum intensity projection images. J Comput Assist Tomogr. 2004. 28:195–203.
crossref
20. Prologo JD, Gilkeson RC, Diaz M, Cummings M. The effect of single-detector CT versus MDCT on clinical outcomes in patients with suspected acute pulmonary embolism and negative results on CT pulmonary angiography. AJR Am J Roentgenol. 2005. 184:1231–1235.
crossref
21. Perrier A, Roy PM, Sanchez O, Le Gal G, Meyer G, Gourdier AL, Furber A, Revel MP, Howarth N, Davido A, Bounameaux H. Multidetector-row computed tomography in suspected pulmonary embolism. N Engl J Med. 2005. 04. 28. 352:1760–1768.
crossref
22. Lee KS, Yoon JH, Kim TK, Kim JS, Chung MP, Kwon OJ. Evaluation of tracheobronchial disease with helical CT with multiplanar and three-dimensional reconstruction: correlation with bronchoscopy. Radiographics. 1997. 17:555–567. discussion 568 - 570.
crossref
23. Yi CA, Lee KS, Kim EA. Solitary pulmonary nodules: dynamic enhanced multi-detector row CT study and comparison with vascular endothelial growth factor and microvessel density. Radiology. 2004. 233:191–199.
crossref
24. Jeong YJ, Lee KS, Jeong SY. Solitary pulmonary nodule: characterization with combined wash-in and washout features at dynamic multi-detector row CT. Radiology. 2005. 237:675–683.
crossref
25. Chung MJ, Lee KS, Han J, Sung YM, Chong S, Kwon OJ. Pulmonary sclerosing hemangioma presenting as solitary pulmonary nodule: dynamic CT findings and histopathologic comparisons. AJR Am J Roentgenol. 2006. 187:430–437.
crossref
26. Naidich DP, Gruden JF, McGuinness G, McCauley DI, Bhalla M. Volumetric (helical/spiral) CT (VCT) of the airways. J Thorac Imaging. 1997. 12:11–28.
crossref
27. Touliopoulos P, Costello P. Helical (spiral) CT of the thorax. Radiol Clin North Am. 1995. 33:843–861.
28. Schueller-Weidekamm C, Wassermann E, Redl H, Prokop M, Zimpfer M, Herold C, Germann P, Ullrich R. Dynamic CT measurement of pulmonary enhancement in piglets with experimental acute respiratory distress syndrome. Radiology. 2006. 239:398–405.
crossref
29. Hoffman EA, Chon D. Computed tomography studies of lung ventilation and perfusion. Proc Am Thorac Soc. 2005. 2:492–498.
crossref
30. Guerrero T, Sanders K, Castillo E, Zhang Y, Bidaut L, Pan T, Komaki R. Dynamic ventilation imaging from four-dimensional computed tomography. Phys Med Biol. 2006. 51:777–791.
crossref
31. Lee KS, Ernst A, Trentham DE, Lunn W, Feller-Kopman DJ, Boiselle PM. Relapsing polychondritis: prevalence of expiratory CT airway abnormalities. Radiology. 2006. 240:565–573.
crossref
TOOLS