CC BY-NC-ND 4.0 · Indian J Plast Surg 2015; 48(03): 274-277
DOI: 10.4103/0970-0358.173124
Original Article
Association of Plastic Surgeons of India

Pedicle streaking: A novel and simple aid in pedicle positioning in free tissue transfer

Aditya Aggarwal
Department of Plastic, Reconstructive and Aesthetic Surgery, Medanta - The Medicity, Gurgaon, Haryana, India
,
Hardeep Singh
Department of Plastic, Reconstructive and Aesthetic Surgery, Medanta - The Medicity, Gurgaon, Haryana, India
,
Sanjay Mahendru
Department of Plastic, Reconstructive and Aesthetic Surgery, Medanta - The Medicity, Gurgaon, Haryana, India
,
Vimalendu Brajesh
Department of Plastic, Reconstructive and Aesthetic Surgery, Medanta - The Medicity, Gurgaon, Haryana, India
,
Sukhdeep Singh
Department of Plastic, Reconstructive and Aesthetic Surgery, Medanta - The Medicity, Gurgaon, Haryana, India
,
Ashish Khare
Department of Plastic, Reconstructive and Aesthetic Surgery, Medanta - The Medicity, Gurgaon, Haryana, India
,
Umang Kothari
Department of Plastic, Reconstructive and Aesthetic Surgery, Medanta - The Medicity, Gurgaon, Haryana, India
,
Rakesh Kumar Khazanchi
Department of Plastic, Reconstructive and Aesthetic Surgery, Medanta - The Medicity, Gurgaon, Haryana, India
› Author Affiliations
Further Information

Publication History

Publication Date:
26 August 2019 (online)

ABSTRACT

Introduction: The pedicle positioning in free tissue transfer is critical to its success. Long thin pedicles are especially prone to this complication where even a slight twist in the perforator can result in flap loss. Pedicles passing through the long tunnels are similarly at risk. Streaking the pedicle with methylene blue is a simple and safe method which increases the safety of free tissue transfer. Materials and Methods: Once the flap is islanded on the pedicle and the vascularity of the flap is confirmed, the pedicle is streaked with methylene blue dye at a distance of 6-7 mm. The streaking starts from the origin of the vessels and continued distally on to the under surface of flap to mark the complete course of the pedicle in alignment. The presence of streaking in some parts and not in rest indicates twist in the pedicle. Observation and Results: Four hundred and sixty five free flaps have been done at our centre in the last 5 years. The overall success rate of free flaps is 95.3% (22 free flap failures). There has not been a single case of pedicle twist leading to flap congestion and failure. Conclusion: This simple and novel method is very reliable for pedicle positioning avoiding any twist necessary for successful free tissue transfer.

 
  • REFERENCES

  • 1 Williams JG, French RJ, Lalonde DH. Why do free flap vessels thrombose? Lessons learned from implantable Doppler monitoring. Can J Plast Surg 2004; 12: 23-6
  • 2 Koul AR, Patil RK, Nahar S. Unfavourable results in free tissue transfer. Indian J Plast Surg 2013; 46: 247-55
  • 3 Gottlieb LJ, Krieger LM. From the reconstructive ladder to the reconstructive elevator. Plast Reconstr Surg 1994; 93: 1503-4
  • 4 Bennett N, Choudhary S. Why climb a ladder when you can take the elevator?. Plast Reconstr Surg 2000; 105: 2266
  • 5 Lee HJ, Lim SY, Pyon JK, Bang SI, Oh KS, Shin MS. et al The influence of pedicle tension and twist on perforator flap viability in rats. J Reconstr Microsurg 2011; 27: 433-8
  • 6 Hamamoto Y, Nagasao T, Ensako T, Tanaka Y. Segmental marking: A new technique to prevent pedicle twisting. J Plast Reconstr Aesthet Surg 2015; 68: 873-4
  • 7 Khouri RK. Avoiding free flap failure. Clin Plast Surg 1992; 19: 773-81
  • 8 Panse N, Sahasrabudhe P. The tunneled perforator flap. Indian J Plast Surg 2012; 45: 158-9
  • 9 Yadav PS, Ahmad QG, Shankhdhar VK, NambiIndian GI. Pedicle transfer in oral cavity reconstruction. J Plast Surg 2010; 43: 79-80
  • 10 Moschella F, D’Arpa S, Di Lorenzo S, Cordova A. Safe pedicle tunnelling in maxillary reconstruction. J Plast Reconstr Aesthet Surg 2010; 63: e289
  • 11 Theodorakopoulou M, Morritt AN, Jallali N. Salvage of a twisted end to side anastomosis with microvascular coupler. J Plast Reconstr Aesthet Surg 2014; 67: e252-3