Korean J Anesthesiol Search

CLOSE


Korean Journal of Anesthesiology 1987;20(5):623-626.
DOI: https://doi.org/10.4097/kjae.1987.20.5.623   
Clinical Application of the Mapleson B System for Controlled Ventilation in Pediatric Patients .
Hee Jong Song, Myung Ae Lee, Chang Kun Ahn
Department of Anesthesiology, National Medical Center, Seoul, Korea.
Abstract
This study was undertaken to observe whether an adult ventilator with a preset volume could be used as a controlled ventrolled ventilator far pediatric anesthesia. 35 Patients ranging in age from 3months to 7 years were divided into two groups based on body weight(Group 1: 5~10kg, 14 cases, Group 2: 11~15kg, 21 cases) and anesthetized with halothane-N2O/O2 - pancuronium using the Mapleson B system. Immediately after induction, the reservoir bay of the Mapleson B system was replaced by the reservoir tube of the adult ventilator (MCM 801). Arterial blood gas studies 30 and 60 minutes after induction were performed, and the data from group 1 was compared with that of group 2. The magnitude of PCO2 increase 30 minutes after induction was not significantly different from that at 60 minutes(p>0.05), and alterations of PCO2 in group 1 were not stati-stically significant with group 2 (P>0.05). In conclusion, it is suggested that the Mapleson B system attached to adult ventilator is an useful and convenient device for controlled ventilation in pediatric patients.


ABOUT
ARTICLE CATEGORY

Browse all articles >

BROWSE ARTICLES
AUTHOR INFORMATION
Editorial Office
101-3503, Lotte Castle President, 109 Mapo-daero, Mapo-gu, Seoul 04146, Korea
Tel: +82-2-792-5128    Fax: +82-2-792-4089    E-mail: journal@anesthesia.or.kr                

Copyright © 2024 by Korean Society of Anesthesiologists.

Developed in M2PI

Close layer
prev next