Clin Orthop Surg. 2018 Dec;10(4):484-490. English.
Published online Nov 21, 2018.
Copyright © 2018 by The Korean Orthopaedic Association
Original Article

Repeatability of a Multi-segment Foot Model with a 15-Marker Set in Normal Children

Eo Jin Kim, MD, Hyuk Soo Shin, MD,* Jae Hee Lee, MD,* Min Gyu Kyung, MD,* Hyo Jeong Yoo, BS,* Won Joon Yoo, MD,* and Dong Yeon Lee, MD*
    • Department of Orthopaedic Surgery, Hanil General Hospital, Seoul, Korea.
    • *Department of Orthopedic Surgery, Seoul National University Hospital, Seoul, Korea.
Received August 03, 2018; Accepted September 27, 2018.

This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.

Abstract

Background

The use of three-dimensional multi-segment foot models (3D MFMs) is increasing since they have superior ability to illustrate the effect of foot and ankle pathologies on intersegmental motion of the foot compared to single-segment foot model gait analysis. However, validation of the repeatability of the 3D MFMs is important for their clinical use. Although many MFMs have been validated in normal adults, research on MFM repeatability in children is lacking. The purpose of this study is to validate the intrasession, intersession, and interrater repeatability of an MFM with a 15-marker set (DuPont foot model) in healthy children.

Methods

The study included 20 feet of 20 healthy children (10 boys and 10 girls). We divided the participants into two groups of 10 each. One group was tested by the same operator in each test (intersession analysis), while the other group was tested by a different operator in each test (interrater analysis). The multiple correlation coefficient (CMC) and intraclass correlation coefficient (ICC) were calculated to assess repeatability. The difference between the two sessions of each group was assessed at each time point of gait cycle.

Results

The intrasession CMC and ICC values of all parameters showed excellent or very good repeatability. The intersession CMC of many parameters showed good or better repeatability. Interrater CMC and ICC values were generally lower for all parameters than intrasession and intersession. The mean gaps of all parameters were generally similar to those of the previous study.

Conclusions

We demonstrated that 3D MFM using a 15-marker set had high intrasession, intersession, and interrater repeatability in the assessment of foot motion in healthy children but recommend some caution in interpreting the hindfoot parameters.

Keywords
Gait analysis; Repeatability; Multi-segment foot model

Several three-dimensional multi-segment foot models (3D MFMs) have been developed for the analysis of dynamic foot kinematics.1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11) The use of such 3D MFMs is increasing since they have superior ability to illustrate the effect of foot and ankle pathologies on intersegmental motion of the foot compared to single-segment foot model gait analysis.4, 12, 13, 14, 15) However, considering the concerns about its reliability, validation of the repeatability of the 3D MFMs is important for their clinical use.16, 17) Although many MFMs have been validated in normal adults, research on MFM repeatability in children is still lacking.18, 19, 20, 21, 22, 23)

A 3D MFM using a 15-marker set (DuPont foot model [DFM]) was recently proposed by Henley and Miller4, 7, 24) and was demonstrated to have comparable intrasession and intersession repeatability to those of other MFMs.25) Segmental foot motion indices at the midstance phase during gait measured using this model were correlated with the conventional radiographic indices.26) However, although validated in healthy adults, this model should also be validated in children prior to being used to assess the intersegmental motion of the foot in pediatric patients. The purpose of this study was to determine the reliability of DFM with a 15-marker set by assessing the subject's stride-to-stride (intrasession), visit-to-revisit (intersession), and observer-to-observer (interrater) repeatability in normal children.

METHODS

Subjects

This study was approved by Institutional Review Board of Seoul National University Hospital (IRB No. 1212-015-447). In this study, volunteers were recruited from the local area and all participants and their guardians provided written informed consent prior to participation. All participants were tested at the Laboratory of Human Motion Analysis in Seoul National University Hospital. The inclusion criteria of this study were as follows: (1) no history of fracture or surgery on the lower extremities; (2) no subjective symptoms during gait; (3) no abnormal findings on a simple radiograph of the foot; (4) no history of a general medical condition related to gait; and (5) normal function of the foot and ankle (American Orthopedic Foot and Ankle Society ankle-hindfoot score of 100 points). In a clinical examination, the alignment and range of motion (ROM) of the lower extremity joints (hip, knee, and ankle) were evaluated and a simple radiograph was checked by two orthopedic surgeons (HSS, JHL) to exclude abnormal conditions of the lower extremities.

Participating subjects included 20 healthy children (10 boys and 10 girls) with 10–15 years of age. Demographic data of the participating subjects are presented in Table 1. The mean age was 12.2 years (range, 11 to 15 years) in boys and 11.1 years (range, 10 to 13 years) in girls. The mean weight was 43.4 kg (range, 30.4 to 76.8 kg) in boys and 43.7 kg (range, 35.8 to 61.1 kg) in girls. The mean height was 149.4 cm (range, 139.4 to 167.2 cm) in boys and 149.7 cm (range, 142.8 to 157.8 cm) in girls. The mean body mass index was 19.1 kg/m2 (range, 15.6 to 31.8 kg/m2) in boys and 19.4 kg/m2 (range, 16.5 to 24.5 kg/m2) in girls. The mean foot length was 22.7 cm (range, 21.6 to 25.2 cm) in boys and 22.5 cm (range, 21.7 to 25.0 cm) in girls. At last, the mean foot width was 9.2 cm (range, 8.3 to 10.6 cm) in boys and 9.0 cm (range, 8.3 to 9.9 cm) in girls. The data of the right foot were selected for the statistical analysis.

Table 1
Demographic Data of Participating Subjects

Marker Set

The DFM examined here is composed of 15 optoreflective markers that were attached to the anatomical landmarks of each knee, tibial shank, ankle, and foot. It is the same model examined previously in a normal adult population,25) but smaller markers were used for the pediatric participants. This system has six additional markers per foot than the conventional Cleveland Clinic Marker Set. The markers were placed as described below.

Five markers were placed around the knee and tibial shank for calculation of the shank coordinate system. Four markers were placed on the ankle and hindfoot (one on the medial malleolus, one on the lateral malleolus, and two on the calcaneus), two on the midfoot (navicular and cuboid), and four on the forefoot (three on the metatarsals and one on the hallux). A more detailed description of the marker placement is provided in Table 2 and shown in Fig. 1.7) All marker placements were made by two operators: one was involved in the previous study of healthy adults and thus was experienced in marker placement; the other had experience handling the conventional Cleveland Clinic Marker Set with reference to the standardized protocol using photography and had no experience in placing these markers.

Fig. 1
Marker placement of a three-dimensional multi-segment foot model with a 15-marker set. (A) Lateral view of marker placement. (B, C) The hallux marker was placed in the middle of the hallux nail bed and two calcaneus markers were applied to the hindfoot. We used smaller markers than those used in adults.

Table 2
Marker Placement of a Multi-segment Foot Model with 15-Marker Set (DuPont Foot Model)

Experimental Procedures

The experimental procedures were the same as those in previous studies.25, 26) First, we explained the procedures and obtained written consent. We then collected each participant's demographic data including height, body weight, and foot length and width. The participants completed a 5-minute warm-up protocol of comfortable walking. After that, each child underwent attachment of the optoreflective markers to each foot and lower extremity. The subjects walked at a comfortable speed along an 8-m walkway. For static calibration, we took data for a static standing trial with the individual in the anatomical position. To collect kinematic gait data, we used 12 cameras with a 3D optical motion capture system (Motion Analysis, Santa Rosa, CA, USA) at a sampling rate of 120 Hz. Eva real-time software (EVaRT, Motion Analysis) was used for real-time motion capturing and post-processing and tracking of the marker data. The difference from our previous study is that we divided participants into two groups of 10 each. One group was tested by the same operator in each test (intersession analysis), while the other was tested by a different operator in each test (interrater analysis). Three representative strides from five separate trials were used for the analysis from each session. Retests were performed at 4-week intervals to check the repeatability using the same protocol.

Foot 3D Multi-Segment Software (Motion Analysis) was used to collect and track the kinematic data of the foot segmental motion. The definition of coordinate systems based on these markers and the calculation method for joint rotation and arch parameters were described previously.7, 25)

Data Analysis

In this study, we analyzed the intrasession, intersession, and interrater repeatability of the DFM using 17 parameters. We divided the time points of the gait cycle data into 100 segments (1% interval between time points) for analysis. We gained three representative stride values from five separate trials and the average of the three strides was considered the representative value from each session. The parameter components are hallux (flexion/extension and rotation), hindfoot (flexion/extension, pronation/supination, and rotation), forefoot (flexion/extension, pronation/supination, and rotation), medial forefoot (flexion/extension, pronation/supination, and rotation), lateral forefoot (flexion/extension, pronation/supination, and rotation), and arch parameters (arch height, arch length, and arch index).

The multiple correlation coefficient (CMC) and intraclass correlation coefficient (ICC) were calculated to assess the intrasession repeatability. Intrasession CMC and ICC values were calculated using data from the first session only. The intrasession CMC was calculated from the first two of three selected strides of the first session, while the intrasession ICC was calculated using the three selected strides.

For intersession repeatability, we obtained average data from the three trials for each visit. The intersession CMC and ICC values were calculated in the same-operator testing group. To assess interrater session repeatability, the same analysis was performed in the changed-operator testing group. The difference between the two sessions of each group was assessed for each time point of the gait cycle. Thereafter, the mean, standard error, and confidence interval of the difference were calculated for each group.

The ROM of each foot segment was calculated for each subject. Intrasession, intersession, and interrater ICC were calculated to assess the intrasession, intersession, and interrater repeatability of the ROM measurements. The intrasession ICC was calculated using three selected strides of the first session, while the intersession ICC was calculated using the mean value of each session.

We classified 0.65 ≤ CMC (R) < 0.75 as moderate repeatability, 0.75 ≤ CMC (R) < 0.85 as good repeatability, 0.85 ≤ CMC (R) < 0.95 as very good repeatability, and CMC (R) ≥ 0.95 as excellent repeatability.27) We interpreted that an ICC < 0.5 suggests poor repeatability, 0.5 ≤ ICC < 0.75 suggests good repeatability, and ICC ≥ 0.75 suggests excellent repeatability.

RESULTS

Walking kinematics in children for the first and second visits were presented in Fig. 2.

Fig. 2
Walking kinematics for the first and second visits (average with a range representing two standard devistions). Med: medial, Lat: lateral.

Table 3 presents the intrasession, intersession, and interrater CMC by 1% intervals of the gait cycle. The mean intrasession CMC was 0.933 (standard deviation [SD], 0.034). The intrasession CMC of all parameters except forefoot pronation/supination showed excellent or very good repeatability. The mean intrasession ICC was 0.975 (SD, 0.028). The intrasession ICC of all parameters showed excellent repeatability.

The mean intersession CMC was 0.793 (SD, 0.077). The intersession CMC showed excellent or very good repeatability in hallux flexion/extension, hallux rotation, hindfoot flexion/extension, arch length, and forefoot flexion/extension and good repeatability in hindfoot pronation/supination, arch height, and arch index. However, forefoot pronation/supination and forefoot rotation had moderate repeatability (0.748 and 0.726, respectively), while hindfoot rotation had poor repeatability (0.371). The mean intersession ICC was 0.886 (SD, 0.123). The intersession ICC of all parameters showed excellent repeatability.

The interrater CMC was not presented in the previous study of healthy adults. However, in this study, interrater CMC values of all parameters were calculated. Interrater CMC values were generally lower for all parameters than intrasession and intersession CMC values. Only arch length had an excellent interrater CMC value. Hallux flexion/extension, hindfoot flexion/extension, arch height, arch index, and forefoot flexion/extension had very good interrater CMC values, while hallux rotation, hindfoot pronation/supination, and forefoot rotation had moderate interrater CMC values. On the other hand, hindfoot rotation and forefoot pronation/supination had poor interrater CMC values (0.623 and 0.482, respectively). Table 4 presents mean, standard error, and confidence interval values of the intersession difference of each time point in 1% intervals. The lowest intersession difference was forefoot flexion/extension (2.26°), whereas the highest value was hindfoot rotation (6.51°).

Table 4
Repeatability of Foot Kinematics (the Gap between Two Sessions)

DISCUSSION

In this study, we demonstrated that the MFM (DFM) had substantial intrasession, intersession, and interrater repeatability in healthy children. Although children had different gait characteristics compared to adults, the intrasession and intersession CMC values were similar to those of healthy adults.25)

In general, the repeatability of 3D MFMs is thought to be good in clinical setting in adult populations.16, 25, 28) Among the widely used MFMs, the Oxford foot model (OFM), Milwaukee foot model, Heidelberg foot model, and modified Shriners Hospitals for Children Greenville foot model in pediatric populations have been used in previous studies.18, 19, 21, 23) The repeatability of MFMs is inferior in the pediatric population to that in the normal adult population.20) In this study, hindfoot flexion/extension, pronation/supination and rotation showed lower intrasession CMC than those from adult study using same DFM model (Table 3). In particular, the intersession CMC of hindfoot rotation was significantly lower than that of adults. However, the intrasession CMC, which was slightly lower than adults, remains in the range of a very good repeatability. The gaps between two sessions in children was larger in all elements of the hindfoot than those of adults (Table 4).

The most contributing factors to increased variability in the pediatric population would be the small size of the foot and the increased gait variability in children.22) It was difficult to attach the marker in the correct position in small children, leading to higher variability in making a segmental plane. The hindfoot markers are usually most vulnerable to inconsistent placement. This study showed some low CMC values and these values were affected by the markers attached to the hindfoot. In addition, the large gait variability in pediatric patients also affect higher variability in children. The gait of pediatric patients may vary by individual growth and development, while adults generally have a standardized gait. Particularly, in the hindfoot, the start of the stance phase of the walking cycle differs significantly in each individual. Although it is difficult to compare our results directly with other studies due to differences in the definition of axes and protocols, the sagittal plane was most repeatable and the highest variability was found in the transverse plane in a study using the OFM in children,20) which were similar to our results. The modified Shriners Hospitals for Children-Greenville (mSHCG) foot model was demonstrated to have improved or nearly equivalent standard deviations for the hindfoot and forefoot segments in children when compared with the OFM.19) However, it is impossible to compare data from the mSHCG foot model with this study because of the difference in the definition of segments and axes.

This study has some limitations. First, the ages of participants were between 10 and 15 years, which might be closer to the ages of adolescents or adults rather than young children. We agree with the belief that accurate marker placement would be more difficult in younger children. The effectiveness of MFMs in younger children still needs to be elucidated further. Second, we found that consistent placement of hindfoot markers would be most important for the repeatability of 3D MFM in children. However, we could not suggest a solution to improve the repeatability of hindfoot measurements in the analysis of segmental foot motions, which needs to be addressed in further research.

The intra- and intersession repeatability of DuPont foot model with a 15-marker set (DFM) in children were comparable to those in healthy adults. However, hindfoot rotation and pronation/supination showed lower intersession/interrater CMCs than those from adult studies using the same DFM model. We believe that the DFM would be applicable for use in the evaluation of intersegmental foot motions in children but careful interpretation is recommended for the hindfoot parameters.

Notes

CONFLICT OF INTEREST:No potential conflict of interest relevant to this article was reported.

ACKNOWLEDGEMENTS

This study was supported by grant (NRF-2015R1D1A1A01061260 & NRF-2016R1D1A1B02009379) of the Basic Science Research Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Education, Science and Technology, Republic of Korea.

References

    1. Bruening DA, Cooney KM, Buczek FL. Analysis of a kinetic multi-segment foot model. Part I: model repeatability and kinematic validity. Gait Posture 2012;35(4):529–534.
    1. Caravaggi P, Benedetti MG, Berti L, Leardini A. Repeatability of a multi-segment foot protocol in adult subjects. Gait Posture 2011;33(1):133–135.
    1. Carson MC, Harrington ME, Thompson N, O'Connor JJ, Theologis TN. Kinematic analysis of a multi-segment foot model for research and clinical applications: a repeatability analysis. J Biomech 2001;34(10):1299–1307.
    1. Church C, Coplan JA, Poljak D, et al. A comprehensive outcome comparison of surgical and Ponseti clubfoot treatments with reference to pediatric norms. J Child Orthop 2012;6(1):51–59.
    1. Cornwall MW, McPoil TG. Three-dimensional movement of the foot during the stance phase of walking. J Am Podiatr Med Assoc 1999;89(2):56–66.
    1. De Mits S, Segers V, Woodburn J, Elewaut D, De Clercq D, Roosen P. A clinically applicable six-segmented foot model. J Orthop Res 2012;30(4):655–661.
    1. Henley J, Richards J, Hudson D, et al. Reliability of a clinically practical multi-segment foot marker set/model. In: Harris GF, Smith PA, Marks RM, editors. Foot and ankle motion analysis: clinical treatment and technology. Boca Raton, FL: CRC Press; 2008. pp. 445-63.
    1. Kidder SM, Abuzzahab FS Jr, Harris GF, Johnson JE. A system for the analysis of foot and ankle kinematics during gait. IEEE Trans Rehabil Eng 1996;4(1):25–32.
    1. Leardini A, Benedetti MG, Berti L, Bettinelli D, Nativo R, Giannini S. Rear-foot, mid-foot and fore-foot motion during the stance phase of gait. Gait Posture 2007;25(3):453–462.
    1. Leardini A, Benedetti MG, Catani F, Simoncini L, Giannini S. An anatomically based protocol for the description of foot segment kinematics during gait. Clin Biomech (Bristol, Avon) 1999;14(8):528–536.
    1. Simon J, Doederlein L, McIntosh AS, Metaxiotis D, Bock HG, Wolf SI. The Heidelberg foot measurement method: development, description and assessment. Gait Posture 2006;23(4):411–424.
    1. Brodsky JW, Coleman SC, Smith S, Polo FE, Tenenbaum S. Hindfoot motion following STAR total ankle arthroplasty: a multisegment foot model gait study. Foot Ankle Int 2013;34(11):1479–1485.
    1. Brodsky JW, Polo FE, Coleman SC, Bruck N. Changes in gait following the Scandinavian total ankle replacement. J Bone Joint Surg Am 2011;93(20):1890–1896.
    1. Canseco K, Long J, Marks R, Khazzam M, Harris G. Quantitative characterization of gait kinematics in patients with hallux rigidus using the Milwaukee foot model. J Orthop Res 2008;26(4):419–427.
    1. Canseco K, Long J, Smedberg T, Tarima S, Marks RM, Harris GF. Multisegmental foot and ankle motion analysis after hallux valgus surgery. Foot Ankle Int 2012;33(2):141–147.
    1. Deschamps K, Staes F, Bruyninckx H, et al. Repeatability in the assessment of multi-segment foot kinematics. Gait Posture 2012;35(2):255–260.
    1. Deschamps K, Staes F, Bruyninckx H, et al. Repeatability of a 3D multi-segment foot model protocol in presence of foot deformities. Gait Posture 2012;36(3):635–638.
    1. Curtis DJ, Bencke J, Stebbins JA, Stansfield B. Intra-rater repeatability of the Oxford foot model in healthy children in different stages of the foot roll over process during gait. Gait Posture 2009;30(1):118–121.
    1. Saraswat P, MacWilliams BA, Davis RB. A multi-segment foot model based on anatomically registered technical coordinate systems: method repeatability in pediatric feet. Gait Posture 2012;35(4):547–555.
    1. Stebbins J, Harrington M, Thompson N, Zavatsky A, Theologis T. Repeatability of a model for measuring multi-segment foot kinematics in children. Gait Posture 2006;23(4):401–410.
    1. Myers KA, Wang M, Marks RM, Harris GF. Validation of a multisegment foot and ankle kinematic model for pediatric gait. IEEE Trans Neural Syst Rehabil Eng 2004;12(1):122–130.
    1. Stolze H, Kuhtz-Buschbeck JP, Mondwurf C, Johnk K, Friege L. Retest reliability of spatiotemporal gait parameters in children and adults. Gait Posture 1998;7(2):125–130.
    1. Twomey D, McIntosh AS, Simon J, Lowe K, Wolf SI. Kinematic differences between normal and low arched feet in children using the Heidelberg foot measurement method. Gait Posture 2010;32(1):1–5.
    1. Nicholson K, Church C, Takata C, et al. Comparison of three-dimensional multi-segmental foot models used in clinical gait laboratories. Gait Posture 2018;63:236–241.
    1. Seo SG, Lee DY, Moon HJ, et al. Repeatability of a multi-segment foot model with a 15-marker set in healthy adults. J Foot Ankle Res 2014;7:24.
    1. Lee DY, Seo SG, Kim EJ, et al. Correlation between static radiographic measurements and intersegmental angular measurements during gait using a multisegment foot model. Foot Ankle Int 2015;36(1):1–10.
    1. Garofalo P, Cutti AG, Filippi MV, et al. Inter-operator reliability and prediction bands of a novel protocol to measure the coordinated movements of shoulder-girdle and humerus in clinical settings. Med Biol Eng Comput 2009;47(5):475–486.
    1. Deschamps K, Staes F, Roosen P, et al. Body of evidence supporting the clinical use of 3D multisegment foot models: a systematic review. Gait Posture 2011;33(3):338–349.

Metrics
Share
Figures

1 / 2

Tables

1 / 4

Funding Information
PERMALINK