Building Physical, Energetical and Hygrothermal Analysis of Earth-Sheltered Building Constructions

Article Preview

Abstract:

Covering soil layer significantly reduces the heat loss of earth-sheltered building elements. Quantity of heat loss is highly influenced by the thickness of soil on examined building constructions. Based on the above mentioned facts an earth-sheltered sample building was designed. Ecological designing principles (recycled building materials and passive solar designing rules) were taken into consideration during planning of examined residential house. The building structures are general solutions, the earth-sheltered characteristic manifested by soil-covered elevations and green roof. The detailed energetic calculations are based on the linear heat transmission coefficient, which serves as a numerical definition of the heat bridge effect. Linear heat transmission coefficients were calculated as simulational results that can be derived from the finite element modelling of structural intersections. Detailed building simulations represent the advantages of soil covering. Hygrothermal analysis of building constructions based on their thermal simulations is essential. Due to the intensified waterproofing of earth-sheltered structures vapour diffusion is considerably reduced. At the same time environmentally conscious design prefers diffusion open orders of layers. Hygrothermal calculations of different waterproofing materials can categorise the environmental friendly solution of the protection.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

369-373

Citation:

Online since:

February 2014

Export:

Price:

[1] L. Farkas, MSc thesis, Designing an earth house and analysing it from a building energetic aspect, manuscript (2013) (in Hungarian).

Google Scholar

[2] Information on http: /www. zoldnet. hu (Downloaded: 01. 09. 2013) (in Hungarian).

Google Scholar

[3] 7/2006. (V. 24. ) TNM regulation for calculation on building energetics (in Hungarian).

Google Scholar

[4] A. Zöld, M. Baumann, T. Csoknyai, F. Kalmár, Z. Magyar, A. Majoros, M. Osztroluczky, Zs. Szalay, The new building energetics regulation – Guide (2006).

Google Scholar

[5] MSZ-04-140-2: 1991 Hungarian standard for calculation of hygrothermal properties.

Google Scholar

[6] J. Várfalvi, Hygrothermal dimensioning of building constructions, thesis work for Hungarian Academy of Sciences, 1993 (in Hungarian).

Google Scholar

[7] H.M. Künzel, A. Holm, D. Zirkelbach, A.N. Karagiozis, Simulation of indoor temperature and humidity conditions including hygrothermal interactions with the building envelope, Solar Energy 78 (2005) 554-561.

DOI: 10.1016/j.solener.2004.03.002

Google Scholar

[8] D. Valtinyi, Hydrothermal characteristics – practicum (in Hungarian) (2011) www. met. bme. hu.

Google Scholar

[9] Information on http: /www. schomburg. de/en/AQUAFIN-2K_M-17314-211-product. html.

Google Scholar