Design of Test Device for Carbon Dioxide Absorbents as Energy Materials Based on Pressure Sensor and Temperature Sensor

Article Preview

Abstract:

This thesis introduces design principle, methods and composition of a new test device for carbon dioxide absorbents as energy materials based on pressure sensor and temperature sensor. The error of the test device is analyzed. The results show that the error of the device is acceptable after correcting, the error can be ignored. The test results are reliable.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

13-17

Citation:

Online since:

October 2012

Export:

Price:

[1] MT454-2008, The Calcium Hydroxide Specification for the Isolation Type Oxygen Respirator and the Self-rescuer.

Google Scholar

[2] Shao bin, Experiment Method of CO2 Gas Volume Measured with Micro Pressure Sensor, Submarine Academic Research, 2010 124(1).

Google Scholar

[3] Li zeng-hua, Improvement of Performance Test Methods of CO2 Absorbent, Safety in Coal Mines, 2005 36(11).

Google Scholar