QCM Detection of HBV Based on Au-NPs/CNTs Signal Amplification

Article Preview

Abstract:

Gold nanoparticles/carbon nanotubes (Au-NPs/CNTs) composites synthesized by microwave-assisted method was modified on the gold coated quartz crystal by chitosan (CHIT) to immobilize anti-HbsAg antibody (HBsAb). Thus a HBsAb/(Au-NPs/CNTs)/CHIT/gold electrode was constructed and applied to the quantitative determination of Hepatitis B surface antigen (HBsAg) by quartz crystal microbalance (QCM). The obtained results show that Au-NPs/CNTs composites possessing high specific surface area is superior to gold nanoparticles (Au-NPs) in improving the detection sensitivity of HBsAg, and the detection sensitivity is 25.571 Hz/(μg/mL) and the linear range is 0.01 μg/mL ~ 5.0 μg/mL. The QCM immunosensor has good regenerability and not significant difference with ELISA in sample detection.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

767-771

Citation:

Online since:

June 2013

Export:

Price:

[1] C. Brechot, D.Kremsdorf, P. Soussan, P. Pineau, A. Dejean, P. Paterlini-Brechot and P. Tiollais: Pathologie. Biologie. Vol. 58 (2010), pp.278-287.

DOI: 10.1016/j.patbio.2010.05.001

Google Scholar

[2] H. Nuriya, K. Inoue, T. Tanaka, Y. Hayashi, T. Hishima, N. Funata, K. Kaji, S. Hayashi, S. Kaneko and M. Kohara: J. Clin. microbiol. Vol. 48(2010), pp.3843-3851.

DOI: 10.1128/jcm.00415-10

Google Scholar

[3] C.I. Costa, I.F. Delgado, J. A.C. Da Costa, R.F. De Carvalho, S. Da Silva Mouta e Júnior, C.O.A. Vianna and M.T.B. de Moraes: J. Virol. MethodS. Vol. 172(2011), pp.32-37.

DOI: 10.1016/j.jviromet.2010.12.010

Google Scholar

[4] L.A. Theisen, S.J. Martin and A.R. Hillman: Anal. Chem. Vol. 76(2004), pp.796-804

Google Scholar

[5] R. Fogel and J.L. Limson: Enzyme. Microb. Tech. Vol. 49(2011), pp.146-152.

Google Scholar

[6] A.S. Afonso, B.F. Zanetti, A.C. Santiago, F. Henrique-Silva, L.H.C. Mattoso and R.C. Faria: Talanta. Vol. 104 (2013), pp.193-197.

DOI: 10.1016/j.talanta.2012.11.003

Google Scholar

[7] P. Ivanoff Reyes, Z.Q. Duan, Y.C. Lu, D. Khavulya and N. Boustany: Biosens Bioelectron. Vol. 41(2013), pp.84-89.

Google Scholar

[8] M. Vidotti, R.F. Carvalhal, R.K. Mendes, D.C.M. Ferreira and L.T. Kubota: J Brazil Chem Soc. Vol. 22(2011), pp.3-20.

Google Scholar

[9] S.H. Varghese, R. Nair, B.G. Nair,T. Hanajiri,T. Maekawa, T. Yoshida and D.S. Kumar: Curr. nanosci. Vol. 6(2010), pp.331-346.

Google Scholar

[10] R. Villalonga,P. Díez,M. Eguílaz, P. Martínez and J.M. Pingarrón: Acs. Appl. Mater. Inter. Vol. 4(2012), pp.4312-4319.

Google Scholar