Characterization and Quick Screening Methodology of Novel Alloys for Biomedical Applications Using Filtered Cathodic Vacuum Arc Deposited Thin Film

Article Preview

Abstract:

Ti-based amorphous alloys containing no harmful elements are desired. However, many Ti-based amorphous alloys contain toxic elements such as Al, Ni, V and Be. The presence of toxic elements within amorphous alloys is a concern when they are intended for use as a biomaterial. This problem has steered many researchers toward the development of Ti-based amorphous alloys without toxic elements. Our novel amorphous alloys were developed based on this principle. A series of Ti44Zr10Pd10Cu6+xCo23-xTa7 (x = 0, 4, 8) amorphous alloys were developed for biomedical application. A series of protocol tests were performed to check for biocompatibility and potential use of the novel alloys in humans. First, alloy ingots were alloyed by induction melting and then cast into copper molds. The cast rod was then used as the plasma cathode in a filtered cathodic vacuum arc deposition chamber to coat the 25-nm amorphous alloy thin film on the cover glass slides. These coated cover glass slides were then examined for biocompatibility. Cell proliferation and cell differentiation were investigated using Methylthiazol Tetrazolium assay test and by alkaline phosphatase assay on osteoblast like cells (SaOS-2), respectively. Field emission scanning electron microscopy was performed to evaluate the thin film surface characteristics. The thickness of thin film was analyzed using a Stylus profilometer. An adhesion scratch test was administered to evaluate the thin film adhesive strength and indirect hardness comparison. Electron Dispersive X-ray Spectrometry was performed to study the elemental composition. Lastly, a medical grade Ti-6Al-4V alloy was studied in parallel as a control material. Results indicated that all investigated Ti-based amorphous alloys were non-cytotoxic and were comparable to the Ti-6AL-4V. They also demonstrated an ability to support differentiation of osteoblast like cells. The adhesion and the hardness of the thin films on the substrates were superior to that of Ti-6Al-4V. The results suggested that the novel alloys in this study could be potentially utilized in biomedical applications.

You might also be interested in these eBooks

Info:

Periodical:

Solid State Phenomena (Volume 283)

Pages:

78-87

Citation:

Online since:

September 2018

Export:

Price:

* - Corresponding Author

[1] A. Inoue, X.M. Wang, W. Zhang, Developments and applications of bulk metallic glasses, Rev Adv Mater Sci. 18 (2008) 1 – 9.

Google Scholar

[2] G. Kumar, A. Desai, J. Schroers, Bulk metallic glass: The smaller the better, Adv Mater. 23 (2011) 461-76.

DOI: 10.1002/adma.201002148

Google Scholar

[3] J. Schroers, G. Kumar, T.M. Hodges, S. Chan, T.R. Kyriakides, Bulk metallic glasses for biomedical applications, Biomed Mat Dev. 9 (2009) 21-29.

DOI: 10.1007/s11837-009-0128-1

Google Scholar

[4] G. He, J. Eckert, Q.L. Dai, M.L. Sui, W. Loser, M. Hagiwara, et al, Nanostructured Ti-based multi-component alloys with potentialfor biomedical applications, Biomaterials. 24 (2003) 5115–5120.

DOI: 10.1016/s0142-9612(03)00440-x

Google Scholar

[5] S. Rao, T. Uchida, T. Tateishi, T. Okazaki, Y. Asao, et al, Effects of Ti, Al and V ions on the relative growth rate of fibroblasts (L929) and osteoblasts (MC3T3-E1) cells, J Biomed Mater Eng. 6 (1996) 79-86.

DOI: 10.3233/bme-1996-6202

Google Scholar

[6] P.R. Walker, J. Leblanc, M. Sikorska, Effects of aluminium and other cations on the structure of brain and liver chromatin, Biochemistry. 28 (1989) 3911-3915.

DOI: 10.1021/bi00435a043

Google Scholar

[7] M.D. Demetriou, A. Wiest, D.C. Hofmann, W.L. Johnson, B. Han, N. Wolfson, et al, Amorphous metals for hard-tissue prosthesis, J Minerals Metals Mate Society 62 (2010) 83–91.

DOI: 10.1007/s11837-010-0038-2

Google Scholar

[8] S.L. Zhu, S.M. Wang, F.X. Qin, A. Inoue, A new Ti-based bulk glassy alloy with potential for biomedical application, Mater Sci Eng. 459 (2007) 233-237.

DOI: 10.1016/j.msea.2007.01.044

Google Scholar

[9] J.J. Oak, D.V. Louzguine-Luzgin, A. Inoue, Investigation of glass forming ability, deformation andcorrosion behavior of Ni free Ti-based BMG alloys designed for application as dental implant, Mater Sci Eng. 29 (2009) 322-327.

DOI: 10.1016/j.msec.2008.07.009

Google Scholar

[10] J.J. Oak, G.W. Hwang, Y.H. Park, H. Kimura, S.Y. Yoon, A. Inoue, Characterization of surface properties, osteoblast cell culture in Vitro and processing with flow viscosity of Ni free Ti-based bulk metallic glass for biomaterials, J Biomech Sci Eng. 4 (2009).

DOI: 10.1299/jbse.4.384

Google Scholar

[11] S. Buzzi, K. Jin, P.J. Uggowitzer, S. Tosatti, I. Gerber, J.F. Loffler, Cytotoxicity of Zr-based bulk metallic glasses, Intermetallics. 14 (2006) 729–734.

DOI: 10.1016/j.intermet.2005.11.003

Google Scholar

[12] W.M. Elshahawy, I. Watanabea,P. Kramerb, In vitro cytotoxicity evaluation of elemental ions released from different prosthodontic materials, Dental Mater. 25 (2009) 1551 –1555.

DOI: 10.1016/j.dental.2009.07.008

Google Scholar

[13] S.L. Zhu, X.M. Wang, A. Inoue, Glass-forming ability and mechanical properties of Ti-based bulk glassy alloys with large diameters of up to 1 cm, Intermetallics. 16 (2008) 1031–1035.

DOI: 10.1016/j.intermet.2008.05.006

Google Scholar

[14] L. Visai, L.D. Nardo, C. Punta, L. Melone, A. Cigada, M. Imbriani, et al, Titanium oxide antibacterial surfaces in biomedical device, Int J Artificial Org. 34 (2011) 929-946.

DOI: 10.5301/ijao.5000050

Google Scholar

[15] E.W. Morscher, A. Hefti, U Aebi, Severe osteolysis after third body wear due to hydroxyapatite particles from acetabular cup coating, J Bone Joint Surg Am. 80B (1998) 267-272.

DOI: 10.1302/0301-620x.80b2.0800267

Google Scholar

[16] K.A. Gross, W. Walsh, E. Swarts, Analysis of retrieved hydroxyapatite-coated hip prostheses, J Therm Spray Tech. 13 (2004) 190-199.

DOI: 10.1361/10599630418112

Google Scholar

[17] A.N. Murty, G. Scott, M.A.R. Freeman, Hydroxyapatite-coated femoral components in total knee arthroplasty, J Arthroplasty. 18 (2003) 844-851.

DOI: 10.1016/s0883-5403(03)00324-3

Google Scholar

[18] F. Wang, D.Y. Chen, X.S. Qiu, et al, Clinical analysis and prevention from coating shedding of uncemented hip prosthesis, China J Orthop Trauma. 22 (2009) 413-416.

Google Scholar

[19] L. Nimb, K. Gotfredsen, J.S. Jensen, Mechanical failure of hydroxyapatite coated titanium and cobalt chromium molybdenum alloy implants: An animal study, Acta Orthop Belg. 59 (1993) 333-338.

Google Scholar

[20] Y. Duan, S. Zhu, F. Guo, J. Zhu, M. Li, J. Ma, et al, The effect of adhesive strength of hydroxyapatite coating on the stability of hydroxyapatite-coated prostheses in vivo at the early stage of implantation, Arch Med Sci. 8 (2012) 199-208.

DOI: 10.5114/aoms.2012.28545

Google Scholar