Abstract
Two full rotating gantries with different nozzles (multipurpose nozzle with MLC, scanning dedicated nozzle) for a conventional cyclotron system are installed and being commissioned for various proton treatment options at Samsung Medical Center in Korea. The purpose of this study is to use Monte Carlo simulation to investigate the neutron dose equivalent per therapeutic dose, H/D, for X-ray imaging equipment under various treatment conditions. At first, we investigated the H/D for various modifications of the beamline devices (scattering, scanning, multi-leaf collimator, aperture, compensator) at the isocenter and at 20, 40 and 60 cm distances from the isocenter, and we compared our results with those of other research groups. Next, we investigated the neutron dose at the X-ray equipment used for real-time imaging under various treatment conditions. Our investigation showed doses of 0.07 ~ 0.19 mSv/Gy at the X-ray imaging equipment, depending on the treatment option and interestingly, the 50% neutron dose reduction was observed due to multileaf collimator during proton scanning treatment with the multipurpose nozzle. In future studies, we plan to measure the neutron dose experimentally and to validate the simulation data for X-ray imaging equipment for use as an additional neutron dose reduction method.
Similar content being viewed by others
References
J. S. Kim et al., J. Korean Phys. Soc, 55, 1640 (2009).
J. S. Shin et al., Radiation Oncology Journal 29, 206 (2011).
D. W. Miller, Medical physics 22, 1943 (1995).
D. R. Olsen et al., Radiotherapy and Oncology 83, 123 (2007).
E. J. Hall, Int. J. Radiat. Oncol. Biol. Phys. 65, 1 (2006).
R. Macklis, Int. J. Radiat. Oncol. Biol. Phys. 66, 1593 (2006).
Y. Zheng et al., Phys. Med. Biol. 52, 4481 (2007).
S. Yonai et al., Medical physics 36, 4830 (2009).
X. Wang et al., Int. J. Radiat. Oncol. Biol. Phys. 76, 1563 (2010).
M. Yoon et al., Int. J. Radiat. Oncol. Biol. Phys. 77, 1477 (2010).
E. S. Diffenderfer et al., Medical physics 38, 6248 (2011).
S. Kim et al., Radiotherapy and oncology 98, 335 (2011).
Y. Zheng et al., Medical physics 39, 3484 (2012).
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Kim, J.S., Shin, J.S., Kim, D. et al. Feasibility study of the neutron dose for real-time image-guided proton therapy: A Monte Carlo study. Journal of the Korean Physical Society 67, 142–146 (2015). https://doi.org/10.3938/jkps.67.142
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.3938/jkps.67.142