Feasibility of using Geant4 Monte Carlo simulation for IMRT dose calculations for the Novalis Tx with a HD-120 multi-leaf collimator

  • Published:
Journal of the Korean Physical Society Aims and scope Submit manuscript

Abstract

The aim of this study was to develop an independent dose verification system by using a Monte Carlo (MC) calculation method for intensity modulated radiation therapy (IMRT) conducted by using a Varian Novalis Tx (Varian Medical Systems, Palo Alto, CA, USA) equipped with a highdefinition multi-leaf collimator (HD-120 MLC). The Geant4 framework was used to implement a dose calculation system that accurately predicted the delivered dose. For this purpose, the Novalis Tx Linac head was modeled according to the specifications acquired from the manufacturer. Subsequently, MC simulations were performed by varying the mean energy, energy spread, and electron spot radius to determine optimum values of irradiation with 6-MV X-ray beams by using the Novalis Tx system. Computed percentage depth dose curves (PDDs) and lateral profiles were compared to the measurements obtained by using an ionization chamber (CC13). To validate the IMRT simulation by using the MC model we developed, we calculated a simple IMRT field and compared the result with the EBT3 film measurements in a water-equivalent solid phantom. Clinical cases, such as prostate cancer treatment plans, were then selected, and MC simulations were performed. The accuracy of the simulation was assessed against the EBT3 film measurements by using a gamma-index criterion. The optimal MC model parameters to specify the beam characteristics were a 6.8-MeV mean energy, a 0.5-MeV energy spread, and a 3-mm electron radius. The accuracy of these parameters was determined by comparison of MC simulations with measurements. The PDDs and the lateral profiles of the MC simulation deviated from the measurements by 1% and 2%, respectively, on average. The computed simple MLC fields agreed with the EBT3 measurements with a 95% passing rate with 3%/3-mm gamma-index criterion. Additionally, in applying our model to clinical IMRT plans, we found that the MC calculations and the EBT3 measurements agreed well with a passing rate of greater than 95% on average with a 3%/3-mm gamma-index criterion. In summary, the Novalis Tx Linac head equipped with a HD-120 MLC was successfully modeled by using a Geant4 platform, and the accuracy of the Geant4 platform was successfully validated by comparisons with measurements. The MC model we have developed can be a useful tool for pretreatment quality assurance of IMRT plans and for commissioning of radiotherapy treatment planning.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. G. Delaney, S. Jacob, C. Featherstone and M. Barton, Cancer 104, 1129 (2005).

    Article  Google Scholar 

  2. Intensity Modulated Radiation Therapy Collaborative Working Group, Int. J Radiat. Oncol. Biol. Phys 51, 880 (2001).

    Article  Google Scholar 

  3. L. E. Gaspar and M. Ding, Curr. Oncol. Rep. 10, 294 (2008).

    Article  Google Scholar 

  4. V. T. DeVita, Jr. and S. A. Rosenberg, N. Engl. J. Med. 366, 2207 (2012).

    Article  Google Scholar 

  5. D. W. Rogers, Phys. Med. Biol. 51, R287 (2006).

  6. E. Spezi and G. Lewis, Radiat. Prot. Dosimetry 131, 123 (2008).

    Article  Google Scholar 

  7. I. J. Chetty et al., Med. Phys. 34, 4818 (2007).

    Article  Google Scholar 

  8. S. Agostinelli et al., Nucl. Instr. Meth. Phys. Res. A 506, 250 (2003).

    Article  ADS  Google Scholar 

  9. C. Z. Jarlskog and H. Paganetti, IEEE 55, 1018 (2008).

    Google Scholar 

  10. J. Apostolakis et al., Radiat. Phys. Chem. 78, 859 (2009).

    Article  ADS  Google Scholar 

  11. D. W. O. Rogers, Med. Phys. 22, 503 (1995).

    Article  Google Scholar 

  12. E. Poon and F. Verhaegen, Med. Phys. 32, 1696 (2005).

    Article  Google Scholar 

  13. W. Abdel-Rahman, J. P. Seuntjens, F. Verhaegen, F. O. Deblois and E. B. Podgorsak, Med. Phys. 32, 286 (2005).

    Article  Google Scholar 

  14. C. M. Ma et al., Phys. Med. Biol. 45, 2483 (2000).

    Article  Google Scholar 

  15. N. Tyagi, B. H. Curran, P. L. Roberson, J. M. Moran, E. Acosta and B. A. Fraass, J. Phys. Conf. Series 102, 012025 (2008).

    Article  ADS  Google Scholar 

  16. M. K. Fix, W. Volken, D. Frei, D. Frauchiger, E. J. Born and P. Manser, Med. Phys. 38, 5311 (2011).

    Article  Google Scholar 

  17. C. Borges, M. Zarza-Moreno, E. Heath, N. Teixeira and P. Vaz, Med. Phys. 39, 415 (2012).

    Article  Google Scholar 

  18. L. A. Vazquez-Quino, B. Massingill, C. Shi, A. Gutierrez, C. Esquivel, T. Eng, N. Papanikolaou and S. Stathakis, J. Appl. Clin. Med. Phys. 13, 3960 (2012).

    Google Scholar 

  19. H. Okamoto, Y. Fujita, K. Sakama, H. Saitoh, T. Kanai, J. Itami and T. Kohno, Radiol. Phys. Technol. 7, 246 (2014).

    Article  Google Scholar 

  20. L. Grevillot, T. Frisson, D. Maneval, N. Zahra, J. N. Badel and D. Sarrut, Phys. Med. Biol. 56, 903 (2011).

    Article  Google Scholar 

  21. H. Jung, O. Kum, Y. Han, B. Park and K. H. Cheong, J. Korean Phys. Soc. 65, 1829 (2014).

    Article  ADS  Google Scholar 

  22. K. Sutherland, S. Miyajima and H. Date, J. Phys.: Conf. Ser. 74, 021020 (2007).

    ADS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding authors

Correspondence to Kwangzoo Chung or Youngyih Han.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Jung, H., Shin, J., Chung, K. et al. Feasibility of using Geant4 Monte Carlo simulation for IMRT dose calculations for the Novalis Tx with a HD-120 multi-leaf collimator. Journal of the Korean Physical Society 66, 1489–1494 (2015). https://doi.org/10.3938/jkps.66.1489

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.3938/jkps.66.1489

Keywords

Navigation