Article

Surface-Mounted Bare and Packaged Fiber Bragg Grating Sensors for Measuring Rock Strain in Uniaxial Testing

by
Balarabe Wada Isah
1,2 and
Hisham Mohamad
1,*
1
Civil and Environmental Engineering Department, Universiti Teknologi PETRONAS, Bandar Seri Iskandar Perak 32610, Malaysia
2
Department of Civil Engineering, Bayero University Kano, PMB 3011 Kano, Nigeria
*
Author to whom correspondence should be addressed.
Sensors 2021, 21(9), 2926; https://doi.org/10.3390/s21092926
Submission received: 1 January 2021 / Revised: 31 January 2021 / Accepted: 19 February 2021 / Published: 22 April 2021
(This article belongs to the Section Optical Sensors)

Abstract

:
The paper explores the possibility of using high-resolution fiber Bragg grating (FBG) sensing technology for on-specimen strain measurement in the laboratory. The approach provides a means to assess the surface deformation of the specimen, both the axial and radial, through a chain of FBG sensor (C-FBG), in a basic setup of a uniaxial compression test. The method is cost-effective, straightforward and can be commercialized. Two C-FBG; one was applied directly to the sample (FBGBare), and the other was packaged (FBGPack) for ease of application. The approach measures the local strain with high-resolution and accuracy levels that match up to the existing local strain measuring sensors. The approach enables the evaluation of small-strain properties of the specimen intelligently. The finite element model analysis deployed has proven the adaptability of the technique for measuring material deformation. The adhesive thickness and packaging technique have been shown to influence the sensitivity of the FBG sensors. Owing to the relative ease and low-cost of instrumentation, the suggested method has a great potential to be routinely applied for elemental testing in the laboratory.

1. Introduction

The study of the mechanical behavior of rocks provides solutions to engineering problems related to a wide range of human activities, especially with the evolvement of large geotechnical engineering structures, such as deep tunnels, boreholes for oil and gas, and tunnels for storage of radioactive waste. Analyzing the mechanical behavior of rocks requires strain measurement. Most rocks are very stiff, and therefore their strain response to loading is minimal (microstrain) [1]. It requires a very accurate and high-resolution device to obtain a realistic stress-strain relationship of the rocks.
In the laboratory, the uniaxial compression test (UCT) is one of the basic tests routinely performed on rock specimens [2,3,4,5]. Both the International Society for Rock Mechanics (ISRM) [6] and the American Society for Testing and Materials (ASTM) [7] methodizes UCT. Over the years, devices like linear variable differential transformer (LVDT) [8,9], strain gauges [10,11], acoustic emission (AE) [9,12], digital image correlation (DIC) [13,14], and extensometer [15,16] were used during the UCT to determine the strain response of rocks with acceptable accuracy. High-resolution, accuracy, cost-effectiveness, simplicity, and reliability are the major factors that entail the selection of instruments for UCT. Difficulties in mounting, poor resolution, use of many cables, edgy acquisition, high-cost, and loss of alignment towards the end of the test by some devices, continued to exist, which is why other new methods continue to evolve.
Fiber Bragg grating (FBG) sensors have been adopted for measuring various quantities (strain, temperature, pressure, discharge, acceleration, force, displacement, vibration, etc.) as reflected in both application and review studies [17,18]. Perhaps due to the decreasing cost of FBG sensors and the advantages offered over conventional sensors, such as their embeddability, flexibility, small in size, immune to electrical or magnetic interference (EMI), resistance to corrosion, multiplexing, multifunctioning, high-resolution, and high measuring accuracy [17,19,20,21]. FBG sensor is usually imprinted on a bare fiber, and many points can be written along the same fiber forming a chain of FBG sensors. Sometimes FBG requires protection when they are used in a harsh environment. To enhance the mechanical strength and durability of FBG sensors, they are encapsulated in composite material or encased in a steel casing fabricated explicitly for a particular sensing purpose [19,22]. Many techniques of packaging FBG are reported in the literature based on a specific need [23,24,25].
The conventional strain gauges like electrical resistance strain gauges (SG) and linear variable differential transformers (LVDTs) get damaged when in contact with water, and each gauging unit requires many cables making it vulnerable to EMI and electrical noise, thereby affecting the measured strain. The typical extensometer demands to record values manually [26], which is hectic and tiring. Digital techniques entail moving the device frequently and require rigorous post-experimental computation, which is feverish and consumes time. Over the years, the FBG sensor has gained acceptance for use in determining the mechanical behavior of rocks [16,17,27,28,29,30]. FBG has been tentatively bonded to the core specimen for the determination of stiffness properties [16,17,27,28,29,30]. C-FBG can be used to measure both axial and radial strain of rocks. For simplicity and commercialization, C-FBG can be packaged as a single sensor for measuring both radial and axial.
The study intends to report the use of bare and packaged C-FBG sensors for axial and radial strain measurements during the UCT of rock. Two pairs of C-FBG sensors consisting of two packaged (FBGPack) and two bare (FBGBare), respectively and two strain gauges are bonded on each specimen. To ascertain the practicability and efficiency of packaged C-FBG, the strains of the FBGpack are compared with that of the FBGBare, strain gauge (SG) and linear variable differential transformer (LVDT). All the FBG sensors used in the experiments are of the same size and imprinted on the same type of optical fiber (OF) for consistency in the analysis. Numerical studies were conducted on the limestone geometric models to assess the strain transfer through the FBGpack in comparison with the strain transfer through the FBGBare.

2. Principle, Calibration and Packaging of FBG for Strain Sensing

2.1. Principle of FBG Strain Sensing Technology

Standard FBG sensors are usually inscribed on a single-mode optical fiber (SMF), which consists of a cylindrical inner core surrounded by cladding. The refractive index of the core is higher than that of the cladding. SMF allows the transmission of a single ray of light over a long-distance, making it suitable for various applications. The most common way of inscribing FBG is by using a phase mask method where a short segment of the fiber core is exposed to intense ultraviolet (UV) light through a medium (phase mask). When the UV light passes through the phase mask, it got diffracted to split into ±1 diffractive order. The fiber is positioned close to the phase mask, and once the fiber is exposed to the diffracted UV beams, it generates a periodic pattern to write a grating on the fiber core. Depending on the phase mask’s periodic pattern space, the grating period would be half of the phase mask’s period length. A reflection prism is used to inscribe FBG of various grating lengths with the aid of an adjustable linear guide to adjust the UV beam’s distance passing through the fiber core. The phase mask technique is simple and cheap. An inexpensive excimer laser can be used for writing FBG, which makes it suitable for the mass production environment.
Fiber exposure to UV light creates a permanent periodic alteration in the fiber core’s refractive index along the axis of the fiber called Bragg grating, which reflects a particular band of light wavelength and transmits all the others when broadband of light source is launched into the fiber. The UV pulse energy must be adjusted to a correct level to produce a perfect FBG sensor. The fiber coating must be removed with a standard stripping tool. The amount of alteration depends on the intensity of the UV light, photosensitivity of the SMF, and exposure duration. Usually, UV light is produced by a krypton fluoride (KrF) excimer laser at 248 nm or an argon fluoride (ArF) excimer laser at 193 nm [31].
FBG sensing technology is well-known for measuring the strain and temperature of various structures. Figure 1 illustrates the working principle of the FBG strain sensor and how strain is measured with the FBG sensor. When OF is subjected to an external load, it alters the wavelength of the reflected light (Bragg wavelength), as shown in Figure 1. The relationship between Bragg wavelength and change in strain ∆ε or change in temperature ∆T can be determined with Equation (1) [32]. Temperature change also affects the Bragg wavelength shift through thermal expansion and contraction of the periodicity and refractive index of the gratings [33]. Therefore, it is important to apply temperature compensation where FBG is used in an environment where temperature varies.
∆λBB = (1 − 𝑝eff)∆ε + (ξ + 𝛼)∆T
where λB is the Bragg wavelength given as 2neffΛ, 𝑝effis the effective photo-elastic parameter related to the fiber core, ξ is thermal-optics coefficient of the OF core, 𝛼 is the thermal expansion coefficient of the OF, neff is the refraction index of the core of the fiber and Λ is the grating period of index modulation. These parameters are constant for a particular fiber. When a measurement is taken at a relatively uniform temperature, any shift in the Bragg wavelength (∆λB) can be determined using Equation (2). All the uniaxial compression experiments in this study were conducted under relatively the same laboratory temperature and in a relatively short period; therefore, the temperature effect is assumed negligible; hence, Equation (2) is used to obtain the FBG strain:
∆λB = λBε(1 − 𝑝eff)
where (1 − 𝑝eff) is a strain constant given as k. 𝑝effis constant (0.22); therefore, k is approximately 0.78 for a typical SMF.

2.2. FBG Strain Calibration

Many researchers adopt the k value of 0.78, which is acceptable [20,34]. Nevertheless, some SMF may contain impurities; thus, it is good to determined k based on the available SMF. The authors have reported a laboratory technique of calibrating FBG sensors for strain measurement [35]. The apparatus consists of a linear translation stage fitted with a vernier micrometer, a fabricated box to aid the measurement, a mechanical vibration isolation platform, and an FBG fixed between the linear translation stage and the box. The FBG is connected to a smartfiber SmartScan interrogator, and it is used throughout the study. SmartScan is a very compact and robust interrogator. It is a wavelength division multiplexing (WDM) instrument based on a flexible, tunable laser source that enables high-resolution interrogation at multi kilohertz frequencies. The high-frequency scan rates allow oversampling and averaging to give an extraordinary resolution. SmartScan has four channels, scan frequency of 25 kHz, repeatability of less than 1 pm, a wavelength range of 40 nm from 1528 to 1568 nm and operation temperature between −15 to 55 °C [36]. The setup of the experiment is shown in Figure 2a. Both the translation stage and box are mounted on the platform at a distance of 230 mm apart. FBG sensor is fixed between the translation stage and the box. When the vernier micrometer is turned, the corresponding FBG reading is taken with the aid of interrogator. Loading and unloading values are taken at an interval of 0.01 mm. Figure 2b presents the calibration result. The k value was found to be 0.751, with R2 of 0.99 and it is used to determine FBG strain for this study.
Both FBG and SG measure strain by attaching on an object with glue. FBG has high-resolution and more robust over a long-range than SG. FBG sensors can keep pace with SG price-wise. They can even be written in the laboratory on SMF, which is very cheap. If the inscribing machine is available, skilled personnel can imprint FBG on a considerably cheap OF. FBG sensors provide surpassing qualities, making them suitable for specific specialized applications. For instance, FBG sensors work very well with composite materials. They are ideal for measuring high strain (>10,000 μm/m).

2.3. Preparation, Packaging and Attachment of C-FBG Strain Sensors

Several types of fibers can be used to package FBG sensors for engineering purposes: carbon fiber-reinforced polymer (CFRP), glass fiber-reinforced polymer (GFRP), synthetic fiber-reinforced polymer (SFRP). The CFRP was selected due to its strength and lightweight. In addition, the modulus of CFRP and SMF cable is approximately the same. This study harnessed the quasi-distributed sensing capability to package the FBG sensor that can measure both the radial and axial strain of rocks. The packaging consists of a layer of CFRP with FBGs attached to it using cyanoacrylate adhesive followed by a layer of Sellotape to add more protection. The packaging and attachment of all sensors were conducted using cyanoacrylate adhesive throughout the study as it was found to be suitable for pasting FBG on rocks [37].
A pair of FBG sensors are inscribed 25 mm apart, and each pair was spliced to a connector to enable data login. An L-shaped CFRP of approximately 20 mm by 30 mm was prepared, and each pair of FBG sensors was attached to the CFRP of 0.5 mm approximate thickness. Cyanoacrylate adhesive was adopted for pasting the coupled FBG sensors on the CFRP. The coupled FBG sensors were pasted to the CFRP with cyanoacrylate adhesive. They were packaged such that one is oriented to measure the strain Y-axis and the other-oriented to measure deformation along X-axis (Figure 2). By doing so, both axial and radial strain can be measured with a single FBGPack. To enable data comparison, another pair of multiplexed FBGs (FBGBare) were also prepared and spliced to OF connector. Figure 3 illuminates the pictorial view of the final FBGPack sensor.
To minimize attenuation resulting from bending or medium of transmission, standard SMF (SMF-28e) was adopted in all experiments for imprinting FBG sensors and connecting the sensors to the interrogator. In each C-FBG sensor, two FBG sensors are inscribed on the same SMF, with each grating assigned a different wavelength to enable the interrogator to capture and record all readings simultaneously using wavelength division multiplexing. All the assigned wavelengths in this study are within the range of 1528 to 1560 nm (SmartScan wavelength range) to ensure that each sensor works within a particular spectral range. The FBG sensors were supplied by NanZee Sensing Technology Ltd. and were inscribed using the phase mask method described in Section 2. Table 1 shows the typical specifications of the FBG sensors used in the study. All the FBGPack were prepared at least two days prior to testing and attached to the rock specimen a day before the testing. The sensor position was marked on each sample, and the surface was cleaned with alcohol to provide a clean surface free from dusty and oily particles that can affect the bonding strength. Figure 4 shows the steps for sensor preparation, packaging and attachment to rock specimen. FBGBare was also attached directly to each sample for measuring lateral and axial strain. The FBGBare provides a basis for comparing the performance of the FBGPack. Moreover, SG and LVDT were also deployed for validating the results obtained from FBG sensors. The FBGPack is fixed to the required position on the host rock with a thin layer of cyanoacrylate.

3. Materials and Methods

In this study, a limestone rock core of 50 mm in diameter was drilled from an underground sewerage pipeline installation site in Ipoh, Perak, Eastern part of Malaysia. The core was then cut to the size of a laboratory testing specimen of approximately 2.0 aspect ratio (length/diameter). The two faces of the rock are trimmed cautiously to obtain a perfect right circular cylinder following the International Society for Rock Mechanics (ISRM) standard. The specimens are oven-dried for 24 h before testing to ensure testing on the dry state.
The uniaxial compression test is conducted with a servo-controlled RT-1000 compression test machine manufactured by an IPC global rock tester that has an axial loading capacity of 1000 kN. The testing machine is controlled with the aid of software installed in a computer that enables the user to set parameters according to the testing condition. The software provides the user with several options, including the type of the test and the loading condition (axial force-controlled or displacement controlled). Limestone core instrumented with FBGPack, FBGBare, and SG attached to the specimen along both axial and radial direction to record axial and radial strain, respectively, is placed on the lower plate of the machine. For a better comparison of the recorded data, the FBGPack, FBGBare, and SG are positioned adjacent to each other, respectively. The uniaxial test was carried out using a displacement-controlled rate of 0.01 mm/s. Additionally, an LVDT with a measuring range of 10 mm was mounted on the machine frame with the tip touching the top-loading plate to record the axial displacement. Figure 5 shows the testing setup, including how the SG and FBG data are recorded during testing.
Uniaxial testing on the limestone was carried out per the ISRM guidelines and ASTM D7012-07 standards [6], and the test took 2–5 min to complete. The FBG sensors data were recorded throughout the testing period at a frequency of 1000 Hz. FBG measures wavelength, which is converted to strain using the calibration factor obtained in Section 2.2. The converted strains were used to plot the FBG stress-strain curves for each tested specimen. The SG and LVDT data were recorded using an 8 channels dynamic and static strain measurement data logger (GTDL-160). The SG, LVDT and data logger are manufactured by JooShin corporation Korea [38]. The FBG data were recorded with the aid of a SmartScan software installed in a laptop, while the SG and LVDT data were recorded with the support of multiscan software that comes with GTDL-160 data logger (Figure 5).

4. Results and Discussion

4.1. Laboratory Experiment

This section presents and discusses the results of the uniaxial compression test experiments performed on limestone specimens equipped with C-FBG sensors (FBGBare and FBGPack), SG, and LVDT. FBGBare, FBGPack, and SG are attached to the sample for measuring on-specimen (Local) strain, while LVDT is attached to the upper loading plate to measure the crosshead deformation. The experiments were conducted at relatively room temperature, ignoring the effect of changes in temperature on FBG sensors. The C-FBG sensors were connected to two channels of the SmartScan interrogator for data logging. The SG and LVDT were connected to the same data logger, and both were controlled with the same software installed on a laptop. All the sensors were tested by logging in a few seconds of data to ensure all software and hardware are working correctly before the actual testing begins.
The stress was plotted against the axial and radial strain response recorded by FBGBare, FBGPack, SG, and LVDT. A total of 6 specimens were tested, readings from all sensors were recorded, and the results are presented in Figure 6, with each response designated by a distinct color.
Homogenous specimens were selected by visual inspection. As indicated in Figure 6, there is a consistency in the stress-strain curves of all the sensors plotted and for all the specimens. Slight variations in strain response of the local sensors (FBGBare, FBGPack, and SG) are observed in all the specimens. The LVDT data recorded a much higher strain response in all the samples. The higher strain recorded by LVDT is evident as it measures the accumulated deformation from the bottom of the load cell to the bottom plate, while the FBGBare, FBGPack, and SG measure the strain on the specimen. The findings are in agreement with [8,13,39,40], which pointed out that measuring the deformation of the sample using techniques other than the local deformation measuring techniques is accompanied by bedding and system compliance error. During the experiment, two significant damages occurred on the rocks; axial splitting with soft crackling and multi fracturing accompanied by loud crackling and rapid unloading to zero, which agrees with [41,42].
One of the crucial requirements of a local strain measuring device is high-resolution and the ability to capture the small strain response of rock since the rock response to deformation is generally small [40]. To understand the initial strain state achieved by the sensors, the first few loading stages are magnified, as shown in Figure 6 for each tested specimen to appreciate the performance of FBG sensors. Both the FBGBare and FBGPack have demonstrated remarkable performance more than LVDT and similar to the SG in all the specimens.
Furthermore, elastic parameters (Young’s modulus and Poison’s ratio) that provide vital information required for the design of excavation, borehole stability, and defining parameters needed for constitutive models, etc., are computed from the stress–strain curves. All the moduli are determined at about 50% of UCS. Tangent modulus (Et), average Eavg modulus, secant modulus (Es), and Poisson’s ratio (v) are computed as per ASTM D 7012-04 [43]. Figure 7 demonstrates the method adopted for computing Young’s modulus, while the Poisson’s ratio is calculated using Equation (3).
v = (Et of axial curve/Et of lateral curve)
The UCS and variations in the computed Young’s modulus of all the specimens are shown in Table 2. While Young’s modulus obtained from FBGPack is slightly higher in all the samples, the modulus obtained from FBGBare is almost the same as that of the SG in all cases. For instance, considering specimen UC1, with reference to SG, Et for FBGPack, is 8% higher, for FBGBare is 1.44% lower, and for LVDT is 26.9% lower.
Moreover, a parameter m based on Equation (4) was computed, and the results are tabulated in Table 3:
m = Etsensor/EtSG
In Equation (4), EtSG and Etsensor represent the tangent modulus obtained from the SG and each of the other sensors (FBGBare, FBGPack, and LVDT), respectively. m measures the relativeness of the C-FBG sensors and LVDT readings to that of the SG. Values close to unity indicate perfect agreement between the stiffness obtained from SG and other sensors. The values of m from all the C-FBG sensors approach unity, which means a definite correlation between the stiffness from SG and both C-FBG sensors. The values of m for the LVDT are further away from unity; hence, considerable variation in the stiffness, and it even proves the accumulation of bedding and machine compliance error associated with measuring deformation on the machine load cell.
Table 4 summarizes the calculated Poisson’s ratios (v) of the rock from all the sensors. The calculated v from FBGPack is higher in most specimen than the FBGBare and SG, except for the samples UC2 and UC13 that have the same values of v as SG. There is a close resemblance in all the deformation parameters of FBGPack and FBGBare with SG.

4.2. Finite Element Modeling (FEM)

FEM was conducted with Ansys software version R3 2019 to investigate the Strain-Transfer Coefficient (STC) between the rock surface and the FBG in both the bare and packaged FBG sensors (Equation (5) defines STC). The geometric models were constructed in Solidworks for simplicity and then imported to Ansys R3 for modelling. The geometry of the model was made up of 5 parts; the rock specimen, adhesive, bare or packaged FBG sensor, top, and base plates. The rock was designed as a solid deformable cylindrical element of the same size as the experimental test specimen (100 mm by 50 mm); the top and base plates were designated as circular steel plates of 60 mm diameter and 20 mm length. The mesh was a structured mesh with 3D hexahedral elements. The method of meshing used was multizone. Acceptable mech quality was attained with 63,744 total elements and 267,002 nodes. The mesh size of plates and rock were 5 and 1 mm whereas the size of adhesive, packaging and FBG mesh was 0.5 mm. The contact between the specimen and both the top and base steel plates was set as fictional with a 0.02 frictional coefficient. All the remaining contacts were kept bonded. The loading (10 steps) was assigned as a displacement control from the top plate, portraying the experimental condition. Table 5 shows the properties of all the materials used in the FEM. The properties of CFRP and cyano were obtained from the manufacturers [44,45]. The parameters of the UC31 specimen were adopted for the FEM analysis.
S T C = ( 1 ε r   ε f ε r ) × 100   ( % )
where εr and εf represent deformation on rock and FBG.
The FBG packaging was designed as shown in Figure 8a. The shape of the adhesive on top of the CFRP was presumed to be elliptical, having 2 mm width, and the FBG was immersed in the adhesive. The top adhesive thickness is designated as y, while the bottom adhesive thickness is x. The thickness of CFRP and the adhesive that attached the package sensor on the rock were kept at 0.3 and 0.1 mm, respectively. During the FEM, displacement was applied at the top plate incrementally, and the base plate was kept as fixed support. The model elements, meshing, loading, and FEM analysis are shown in Figure 8.
An STC analysis of the package FBG sensors was carried out as per Table 6. The analysis was in three classes; in class 1, 2, and 3, the package length was kept at 15, 20 and 30 mm, respectively, while the bottom adhesive thickness (x) was varied, keeping the adhesive thickness on top of the FBG (y) constant. Studies have shown that the effect of the top thickness (y) is negligible [46,47]. As such, it was kept at 0.2 mm throughout this study.
The comparison of the stress-strain curves of FBGBare, FBGPack, strain from FBG and rock elements of FBGPack FEM are shown in Figure 9. The stress-strain curves of FBGPack FEM is based on a packaging length of 30 mm, the bottom thickness of 0.05 mm and 0.05 mm thickness of adhesive between the CFRP and limestone. All the curves are typical of brittle character; hence, both models were suitable for characterizing the behavior of limestone rock tested. There was an agreement between the resulted of the tested and FEM specimen, which validated the suitability of FBG sensors for strain measurement in uniaxial compression testing. Values of E were computed as illuminated in Table 7. Even the stiffness parameters of tested and FEM specimens accorded well with each other. Though all the results were in agreement with the limit of experimental error, FBGPack results were more similar to FEM than FBGBare.
Table 8 presents the effect of packaging length and bottom adhesive thickness (x) on STC. It can be observed that the length of the package sensor influenced the STC. When the length increased, the STC also increased. There was also a reduction in STC with an increase in the bottom thickness. STC was more than 90% at 30 mm packaging length in all adhesive thickness. Both the length and bottom thickness had influenced the STC. The highest value of STC was observed at 30 mm packaging length and 0.05 mm bottom thickness (x); therefore, it was selected for all subsequent analyses. Adhesive thickness was shown to have greatly influenced STC.
Furthermore, the comparison of STC between the FBGBare and FBGPack demonstrated that FBGBare was more sensitive than FBGPack (Figure 10). This may be attributed to the presence of the packaging layer in the case of FBGPack. Figure 10a compare FBGBare and FBGPack based on the variation of the bottom thickness (x), while the effect of varying the adhesive thickness between FBGBare and limestone, CFRP and limestone are shown in Figure 10b, respectively. It is important to note that the bottom thickness was the same as the thickness between the FBG and limestone for FBGBare. STC reduced with the increase in adhesive thickness.
Figure 11 shows the variation of STC as a function of packaging modulus and Poisson’s ratio (vP) at different values of adhesive Poisson’s ratio (vA). In Figure 11a, vP varied as 0.2, 0.3, and 0.4, CFRP modulus varied as 65, 70, 75 and 80 GPa, while vA was kept constant (0.2). The same scenario was repeated for vA of 0.3. The sensitivity of the packaged FBG sensor rose with increasing CFRP modulus. STC declined with the rise in both vA and vP. This implies that the increase in the package modulus courses corresponding increase in the sensitivity of the sensor, while a rise in Poisson’s ratio of both adhesive and packaging material reduced the sensitivity of the sensor.

4.3. Study of the Effect of Frictional Coefficient (FC) between Steel Plates and Specimen

In many testing situations, less attention is given to the influence of FC on rock stress and strain data. In this section, five models were analyzed by varying FC (0.05, 0.1, 0.15, 0.2 and 0.25). Figure 12 indicted high peak stress and strain values when FC was increased. Both peak stress and strain values followed a similar trend. This highlights the importance of lubricating the top and button steel plates while conducting UCS testing to reduce the effect of FC on the experimental results.

5. Conclusions

Smart techniques of measuring rock deformation precisely with reasonable accuracy using C-FBG sensors are presented and evaluated. Uniaxial compression tests were performed on samples with sensors attached to the specimen and the machine load cell. C-FBG sensors have been shown to offer the advantages of measuring both radial and axial strain with a single sensor and allowing packaging to ease labour and sensor attachment complications on the sample.
According to the experimental test results, both the FBGBare and FBGPack compete with SG and have much higher accuracy than the conventional LVDT. The sensors have demonstrated effectiveness in monitoring the small strain deformational response of rocks with ease, high-resolution, and accuracy. It was found out the stiffness parameters obtain from FBGBare and FBGPack nearly the same as that of the SG.
Furthermore, the FEM employed demonstrated the applicability of the concept for measuring correct material properties in the laboratory. The STC analyses revealed the influence of adhesive thickness and packaging material on the sensitivity of both FBGBare and FBGPack. Even though FBGBare is more sensitive than FBGPack, FBGPack can measure material deformation with reasonable accuracy. Based on the experimental and numerical findings, C-FBG sensors can be utilized to measure strain response in the laboratory.

Author Contributions

B.W.I.: Conceptualization methodology, software, data curation, writing—original draft preparation. H.M.: supervision, visualization, investigation, validation, writing—reviewing and editing. All authors have read and agreed to the published version of the manuscript.

Funding

This research was funded by YUTP Fundamental Research Grant Scheme, grant number 015LC0-178.

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

Not applicable.

Acknowledgments

The authors are grateful to Universiti Teknologi PETRONAS (UTP) for the financial support given through the graduate assistantship (GA) scheme.

Conflicts of Interest

The authors declare no conflict of interest. They have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.

References

  1. Hamdi, P. Characterization of Brittle Damage in Rock from the Micro to Macro Scale. Ph.D. Thesis, Simon Fraser University, Burnaby, BC, Canada, 10 August 2015. [Google Scholar]
  2. Roshan, H.; Masoumi, H.; Hagan, P. On size-dependent uniaxial compressive strength of sedimentary rocks in reservoir geomechanics. In Proceedings of the 50th US Rock Mechanics/Geomechanics Symposium, ARMA, Houston, TX, USA, 26–29 June 2016; pp. 2322–2327. [Google Scholar]
  3. Nicksiar, M.; Martin, C.D. Crack initiation stress in low porosity crystalline and sedimentary rocks. Eng. Geol. 2013, 154, 64–76. [Google Scholar] [CrossRef]
  4. Miranda, T.; Sousa, L.R.; Gomes, A.T.; Tinoco, J.; Ferreira, C. Geomechanical characterization of volcanic rocks using empirical systems and data mining techniques. J. Rock Mech. Geotech. Eng. 2017, 10, 138–150. [Google Scholar] [CrossRef]
  5. Hoek, E.; Martin, C.D. Fracture initiation and propagation in intact rock–a review. J. Rock Mech. Geotech. Eng. 2014, 6, 287–300. [Google Scholar] [CrossRef] [Green Version]
  6. Bieniawski, Z.T.; Bernede, M.J. Suggested methods for determining the uniaxial compressive strength and deformability of rock materials. Part 1. Suggested method for determination of the uniaxial compressive strength of rock materials. Int. J. Rock Mech. Min. Sci. 1979, 16, 137. [Google Scholar] [CrossRef]
  7. ASTM. D3148-02 Standard Test Method for Elastic Moduli of Intact Rock Core Specimens in Uniaxial Compression; ASTM International: West Conshohocken, PA, USA, 2002; Available online: https://www.astm.org/Standards/D3148.htm (accessed on 22 February 2021).
  8. Dautriat, J.; Bornert, M.; Gland, N.; Dimanov, A.; Raphanel, J. Localized deformation induced by heterogeneities in porous carbonate analysed by multi-scale digital image correlation. Tectonophysics 2011, 503, 100–116. [Google Scholar] [CrossRef]
  9. Bartmann, K.; Alber, M. Experimental Determination of Crack Initiation and Crack Damage of Two Granites. Procedia Eng. 2017, 191, 119–126. [Google Scholar] [CrossRef]
  10. Roshan, H.; Masoumi, H.; Regenauer-Lieb, K. Frictional behaviour of sandstone: A sample-size dependent triaxial investigation. J. Struct. Geol. 2017, 94, 154–165. [Google Scholar] [CrossRef]
  11. Shen, J.; Jimenez, R.; Karakus, M.; Xu, C. A simplified failure criterion for intact rocks based on rock type and uniaxial compressive strength. Rock Mech. Rock Eng. 2014, 47, 357–369. [Google Scholar] [CrossRef]
  12. Bahaaddini, M.; Hosseinpour Moghadam, E. Evaluation of empirical approaches in estimating the deformation modulus of rock masses. Bull. Eng. Geol. Environ. 2019, 78, 3493–3507. [Google Scholar] [CrossRef]
  13. Munoz, H.; Taheri, A.; Chanda, E.K. Pre-Peak and Post-Peak Rock Strain Characteristics During Uniaxial Compression by 3D Digital Image Correlation. Rock Mech. Rock Eng. 2016, 49, 2541–2554. [Google Scholar] [CrossRef]
  14. Lin, Q.; Labuz, J.F. Fracture of sandstone characterized by digital image correlation. Int. J. Rock Mech. Min. Sci. 2013, 60, 235–245. [Google Scholar] [CrossRef]
  15. Munoz, H.; Taheri, A. Specimen aspect ratio and progressive field strain development of sandstone under uniaxial compression by three-dimensional digital image correlation. J. Rock Mech. Geotech. Eng. 2017, 9, 599–610. [Google Scholar] [CrossRef]
  16. Schmidt-Hattenberger, C.; Naumann, M.; Borm, G. Fiber Bragg grating strain measurements in comparison with additional techniques for rock mechanical testing. IEEE Sens. J. 2003, 3, 50–55. [Google Scholar] [CrossRef]
  17. Park, J.; Kwon, Y.S.; Ko, M.O.; Jeon, M.Y. Dynamic fiber Bragg grating strain sensor interrogation with real-time measurement. Opt. Fiber Technol. 2017, 38, 147–153. [Google Scholar] [CrossRef]
  18. Di Sante, R. Fibre optic sensors for structural health monitoring of aircraft composite structures: Recent advances and applications. Sensors 2015, 15, 18666–18713. [Google Scholar] [CrossRef] [PubMed]
  19. Lee, S.C.; Tee, B.P.; Chong, M.F.; Ku Mahamud, K.M.; Mohamad, H. Structural Assessment for an old Steel Railway Bridge Under Static and Dynamic Loads Using Fibre Optic Sensors. In Proceedings of the International Conference on Smart Infrastructure and Construction 2019 (ICSIC): Driving data-informed decision-making, Churchill College, Cambridge, UK, 8 July 2019; pp. 729–736. [Google Scholar]
  20. Sun, Y.; Li, Q.; Yang, D.; Fan, C.; Sun, A. Investigation of the dynamic strain responses of sandstone using multichannel fiber-optic sensor arrays. Eng. Geol. 2016, 213, 1–10. [Google Scholar] [CrossRef]
  21. Sun, Y.; Li, Q.; Fan, C. Laboratory core flooding experiments in reservoir sandstone under different sequestration pressures using multichannel fiber Bragg grating sensor arrays. Int. J. Greenh. Gas Control 2017, 60, 186–198. [Google Scholar] [CrossRef]
  22. Torres, B.; Payá-Zaforteza Ignacio, I.; Calderón, P.A.; Adam, J.M. Analysis of the strain transfer in a new FBG sensor for Structural Health Monitoring. Eng. Struct. 2011, 33, 539–548. [Google Scholar] [CrossRef] [Green Version]
  23. Xu, D.S.; Borana, L.; Yin, J.H. Measurement of small strain behavior of a local soil by fiber Bragg grating-based local displacement transducers. Acta Geotech. 2013, 9, 935–943. [Google Scholar] [CrossRef]
  24. Luyckx, G.; Voet, E.; Lammens, N.; Degrieck, J. Strain measurements of composite laminates with embedded fibre bragg gratings: Criticism and opportunities for research. Sensors 2011, 11, 384–408. [Google Scholar] [CrossRef] [Green Version]
  25. Hong, C.Y.; Zhang, Y.F.; Zhang, M.X.; Leung, L.M.G.; Liu, L.Q. Application of FBG sensors for geotechnical health monitoring, a review of sensor design, implementation methods and packaging techniques. Sens. Actuators Phys. 2016, 244, 184–197. [Google Scholar] [CrossRef]
  26. Yang, Y.W.; Bhalla, S.; Wang, C.; Soh, C.K.; Zhao, J. Monitoring of rocks using smart sensors. Tunn. Undergr. Sp. Technol. 2007, 22, 206–221. [Google Scholar] [CrossRef]
  27. Ferdinand, P. The Evolution of Optical Fiber Sensors Technologies During the 35 Last Years and Their Applications in Structure Health Monitoring. In Proceedings of the EWSHM-7th European Workshop on Structural Health Monitoring, IFFSTTAR, Inria, Université de Nantes, Nantes, France, 8 July 2014. [Google Scholar]
  28. Zhao, Y.; Zhang, N.; Si, G. A fiber bragg grating-based monitoring system for roof safety control in underground coal mining. Sensors 2016, 16, 1759. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  29. Castro-Caicedo, A.; Torres, P.; Lain, R. Packaging and testing of fiber Bragg gratings for use as strain sensor in rock specimens. In Proceedings of the 8th Iberoamerican Optics Meeting and 11th Latin American Meeting on Optics, Lasers, and Applications, Porto, Portugal, 18 November 2013; p. 87852R. [Google Scholar]
  30. Castro-Caicedo, A.; Nieto-Callejas, M.J.; Torres, P. Fiber Bragg grating strain sensor for hard rocks. In Proceedings of the International Conference on Optical Fibre Sensors (OFS24), Curitiba, Brazil, 28 September 2015; p. 963449. [Google Scholar]
  31. Hill, K.O.; Meltz, G. Fiber Bragg Grating Technology Fundementals and Overview. IEEE J. Light. Technol. 1997, 15, 1263–1276. [Google Scholar] [CrossRef] [Green Version]
  32. Morey, W.; Meltz, G.; Glenn, H.; Glenn, W. Fiber optic Bragg grating sensors. Proc. SPIE Fiber Opt. Laser Sens. 1989, 1169, 98–107. [Google Scholar] [CrossRef]
  33. Meltz, G.; Morey, W.W.; Glenn, W.H. Formation of Bragg gratings in optical fibers by a transverse holographic method. Opt. Lett. 1989, 14, 823–825. [Google Scholar] [CrossRef] [PubMed]
  34. Sun, Y.; Li, Q.; Fan, C.; Yang, D.; Li, X.; Sun, A. Fiber-optic monitoring of evaporation-induced axial strain of sandstone under ambient laboratory conditions. Environ. Earth Sci. 2017, 76, 379. [Google Scholar] [CrossRef]
  35. Isah, B.W.; Mohamad, H.; Ahmad, N.R.; Harahap, I.S.H. Preliminary view of a smart technique for materials testing in the laboratory using FBG sensor. In Proceedings of the International Conference on Civil, Offshore & Environmental Engineering 2018 (ICCOEE 2018), Kuala Lumpur, Malaysia, 17 September 2018. [Google Scholar]
  36. Our Products-Smartscan. Smart Fibres. Available online: https://www.smartfibres.com/products/smartscan (accessed on 26 January 2021).
  37. Isah, B.W.; Mohamad, H.; Ahmad, N.R. Rock stiffness measurements fibre Bragg grating sensor (FBGs) and the effect of cyanoacrylate and epoxy resin as adhesive materials. Ain Shams Eng. J. 2020. [Google Scholar] [CrossRef]
  38. Geotechnical Monitoring Instruments. Available online: http://www.jooshin.kr/?act=shop.goods_view&GS=419&GC=GD02 (accessed on 1 July 2019).
  39. Acar, M.C.; Gündüz, Z.; Kara, H.B. Modulus of Elasticity Determination of Rocks Using Comressometer, Strain Gauge and Lvdt. Proc. ACE 2014, 11, 2–7. [Google Scholar]
  40. Isah, B.W.; Mohamad, H.; Harahap, I.S.H. Measurement of small-strain stiffness of soil in a triaxial setup: Review of local instrumentation. Int. J. Adv. Appl. Sci. 2018, 5, 15–26. [Google Scholar] [CrossRef] [Green Version]
  41. Hazzard, J.F.; Young, R.P.; Maxwell, S.C. Micromechanical modeling of cracking and failure in brittle rocks. J. Geophys. Res. Solid Earth 2000, 105, 16683–16697. [Google Scholar] [CrossRef]
  42. Mardalizad, A.; Scazzosi, R.; Manes, A.; Giglio, M. Testing and numerical simulation of a medium strength rock material under unconfined compression loading. J. Rock Mech. Geotech. Eng. 2018, 10, 197–211. [Google Scholar] [CrossRef]
  43. ASTM. D7012-14 Standard Test Method for Compressive Strength and Elastic Moduli of Intact Rock Core Specimens Under Varying States of Stress and Temperatures; ASTM International: West Conshohocken, PA, USA, 2014; pp. 4–11. Available online: https://webstore.ansi.org/standards/astm/astmd701214 (accessed on 22 February 2021).
  44. Carbon Fibre Sheet, 300 mm × 300 mm × 1.3 mm | RS Components. Available online: https://my.rs-online.com/web/p/carbon-fibre-sheets/7648707/ (accessed on 17 July 2020).
  45. VT-802/VT-802NT 502 Super Glue-Vital Technical. Available online: https://vitaltechnical.com/product/vt-802-vt-802nt-502-super-glue/ (accessed on 11 January 2020).
  46. Li, J.; Neumann, H.; Ramalingam, R. Design, fabrication, and testing of fiber Bragg grating sensors for cryogenic long-range displacement measurement. Cryogenics 2015, 68, 36–43. [Google Scholar] [CrossRef]
  47. Wan, K.T.; Leung, C.K.Y.; Olson, N.G. Investigation of the strain transfer for surface-attached optical fiber strain sensors. Smart Mater. Struct. 2008, 17, 35037. [Google Scholar] [CrossRef]
Figure 1. Working principle of fiber Bragg grating (FBG) sensors.
Figure 1. Working principle of fiber Bragg grating (FBG) sensors.
Sensors 21 02926 g001
Figure 2. Strain calibration of FBG sensor. (a) FBG sensor strain calibration setup. (b) FGB strain calibration result.
Figure 2. Strain calibration of FBG sensor. (a) FBG sensor strain calibration setup. (b) FGB strain calibration result.
Sensors 21 02926 g002
Figure 3. FBGs packaged for axial and lateral strain measurement.
Figure 3. FBGs packaged for axial and lateral strain measurement.
Sensors 21 02926 g003
Figure 4. The process of packaging and pasting of both FBGpack and FBGBare on limestone rock.
Figure 4. The process of packaging and pasting of both FBGpack and FBGBare on limestone rock.
Sensors 21 02926 g004aSensors 21 02926 g004b
Figure 5. Experimental setup.
Figure 5. Experimental setup.
Sensors 21 02926 g005
Figure 6. Experimental stress-strain curves of limestone specimens (a) UC1, (b) UC2, (c) UC10, (d) UC13, (e) UC26, and (f) UC31.
Figure 6. Experimental stress-strain curves of limestone specimens (a) UC1, (b) UC2, (c) UC10, (d) UC13, (e) UC26, and (f) UC31.
Sensors 21 02926 g006aSensors 21 02926 g006b
Figure 7. The method used to determined Young’s modulus at 50% UCS [7].
Figure 7. The method used to determined Young’s modulus at 50% UCS [7].
Sensors 21 02926 g007
Figure 8. Finite element modeling (FEM) analysis.
Figure 8. Finite element modeling (FEM) analysis.
Sensors 21 02926 g008aSensors 21 02926 g008b
Figure 9. Comparison of experimental and numerical results of sample UCS31.
Figure 9. Comparison of experimental and numerical results of sample UCS31.
Sensors 21 02926 g009
Figure 10. Sensitivity analysis of FBGBare and FBGPack.
Figure 10. Sensitivity analysis of FBGBare and FBGPack.
Sensors 21 02926 g010aSensors 21 02926 g010b
Figure 11. Influence of packaging modulus and Poisson’s ratio on STC.
Figure 11. Influence of packaging modulus and Poisson’s ratio on STC.
Sensors 21 02926 g011aSensors 21 02926 g011b
Figure 12. Variation of peak stress and strain with frictional coefficient (FC).
Figure 12. Variation of peak stress and strain with frictional coefficient (FC).
Sensors 21 02926 g012
Table 1. Typical specifications of the FBG sensors used for experiments.
Table 1. Typical specifications of the FBG sensors used for experiments.
S/NL (mm) Wavelength   λ B   ( nm ) BW@−3dB (nm)SLSR
(dB)
Reflectivity
(%)
1101530.00.1711595
2101533.70.1871395
3101537.00.1841595
4101540.30.1691695
5101544.00.2051495
6101547.60.1841395
7101551.10.1831695
8101554.50.2041595
9101558.00.1991595
L: length of the gratings; λB: central wavelength (CW) corresponding to each grating; SLSR: side lobe suppression ratio: highest secondary peak bigger than 3 dB amplitude within ±3 nm from CW. For standard FBGs SLSR > 15 dB; reflectivity R% = 1–10(T(dB)/10): Measured from transmission spectra.
Table 2. UCS and Young’s modulus obtained from all the sensors on each specimen.
Table 2. UCS and Young’s modulus obtained from all the sensors on each specimen.
S/NUCS (MPa)ModulusFBGPackFBGBareSGLVDT
UC1 Et (MPa)30,07027,30027,70020,240
48.98Eav (MPa)29,31027,63028,28020,230
Es (MPa)33,54733,32033,45621,769
UC2 Et (MPa)23,82023,03022,22016,770
45.8Eav (MPa)23,79022,07021,97016,840
Es (MPa)23,13023,13121,81015,793
UC10 Et (MPa)32,52031,560-28,150
52.56Eav (MPa)32,82031,890-28,080
Es (MPa)35,99035,892-25,022
UC13 Et (MPa)29,01027,56029,05022,350
51.25Eav (MPa)28,80026,88028,25021,810
Es (MPa)28,44426,94726,14818,920
UC26 Et (MPa)19,30020,42019,30017,100
32.81Eav (MPa)19,13520,29019,13017,350
Es (MPa)20,50018,22219,29413,015
UC31 Et (MPa)29,75028,78029,87022,610
63.27Eav (MPa)28,86027,23028,05021,990
Es (MPa)30,17027,00228,59017,416
Table 3. Variation of m for sensors across the specimens.
Table 3. Variation of m for sensors across the specimens.
Specimenm
FBGPack
m
FBGBare
m
LVDT
UC11.080.980.73
UC21.071.040.76
UC10---
UC130.990.950.77
UC2611.050.89
UC311.000.960.76
Table 4. Poisson’s ratio of each specimen computed from the sensors.
Table 4. Poisson’s ratio of each specimen computed from the sensors.
SpecimenFBGPackFBGBareSG
UC10.30.230.21
UC20.30.240.3
UC100.270.25
UC130.320.290.32
UC260.250.230.22
UC310.210.230.22
Table 5. Properties of model materials.
Table 5. Properties of model materials.
LimestoneSteelCyanoCFRPFBGs
E (GPa)29.752001.887073
ν 0.210.30.20.320.2
UCS (MPa)63.27----
σ t (MPa)6.1046023.3504.3
κ (GPa)17.1166.671.0464.8243.45
G (GPa)12.376.920.7826.5229.92
ρ (kg/m3)28007850-16002600
Table 6. FBGPack specification for FEM analysis.
Table 6. FBGPack specification for FEM analysis.
DivisionLength (mm)Y (mm)X (mm)
Class 1150.20.05
150.20.1
150.20.2
Class 2200.20.05
200.20.1
200.20.2
Class 3300.20.05
300.20.1
300.20.2
Table 7. Comparison of stiffness parameters of FEM and experimental results.
Table 7. Comparison of stiffness parameters of FEM and experimental results.
SpecimenAnalysisEt
(GPa)
Eav
(GPa)
Es
(GPa)
UC31FEMRock30,56030,45030,170
FEMFBG31,34031,44032,192
FBGBare28,78027,23027,002
FBGPack29,75028,86030,170
SG29,87028,05028,590
Table 8. Variation of strain-transfer coefficient (STC) with packaging length.
Table 8. Variation of strain-transfer coefficient (STC) with packaging length.
Packaging Length (mm)STC at x = 0.05 (%)STC at x = 0.1 (%)STC at x = 0.2 (%)
1582.2481.5580.33
2090.1489.4488.5
3093.6492.8791.55
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Isah, B.W.; Mohamad, H. Surface-Mounted Bare and Packaged Fiber Bragg Grating Sensors for Measuring Rock Strain in Uniaxial Testing. Sensors 2021, 21, 2926. https://doi.org/10.3390/s21092926

AMA Style

Isah BW, Mohamad H. Surface-Mounted Bare and Packaged Fiber Bragg Grating Sensors for Measuring Rock Strain in Uniaxial Testing. Sensors. 2021; 21(9):2926. https://doi.org/10.3390/s21092926

Chicago/Turabian Style

Isah, Balarabe Wada, and Hisham Mohamad. 2021. "Surface-Mounted Bare and Packaged Fiber Bragg Grating Sensors for Measuring Rock Strain in Uniaxial Testing" Sensors 21, no. 9: 2926. https://doi.org/10.3390/s21092926

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop