Next Article in Journal
Translational Imaging Spectroscopy for Proximal Sensing
Next Article in Special Issue
Review of CMOS Integrated Circuit Technologies for High-Speed Photo-Detection
Previous Article in Journal
Recent Trends on Electrochemical Sensors Based on Ordered Mesoporous Carbon
Previous Article in Special Issue
III–V-on-Silicon Photonic Integrated Circuits for Spectroscopic Sensing in the 2–4 μm Wavelength Range
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Optical Refractive Index Sensing Based on High-Q Bound States in the Continuum in Free-Space Coupled Photonic Crystal Slabs

Department of Electrical Engineering, University of Texas at Arlington, Arlington, TX 76019, USA
*
Authors to whom correspondence should be addressed.
Sensors 2017, 17(8), 1861; https://doi.org/10.3390/s17081861
Submission received: 30 June 2017 / Revised: 5 August 2017 / Accepted: 9 August 2017 / Published: 11 August 2017
(This article belongs to the Special Issue Silicon Technologies for Photonic Sensors)

Abstract

:
High sensitivity (S) and high quality factor (Q) are desirable to achieve low detection limit in label-free optical sensors. In this paper, we theoretically demonstrate that single-layer and coupled bi-layer photonic crystal slabs (PCS) possess simultaneously high S and high Q near the bound states in the continuum (BIC). We theoretically achieved S > 800 nm/RIU and Q > 107 in refractive index sensing in the 1400–1600 nm telecom optical wavelength bands. We experimentally demonstrated an S of 94 nm/RIU and a Q of 1.2 × 104, with a detection limit of 6 × 10−5 refractive index unit. These sensor designs can find applications in biochemical sensing, environmental monitoring, and healthcare.

1. Introduction

Optical biosensors are widely-used for biomedical research, healthcare, and environmental monitoring. Compared with optical sensors based on fluorescence measurement, label-free optical sensors do not need to label the biomolecules, which reduces the effort for sample preparation and enables rapid analysis in real time [1,2]. Refractive index (RI) detection is commonly used for label-free sensors. RI-based sensing has been studied in the analysis of biochemical molecules detection [3,4,5,6,7], drug compound screening [8], and gas detection [9,10,11].
The performance of a sensor can be fully described by detection limit (DL). High quality factors (Q) or RI sensitivities (S) for the resonance will help to achieve a lower detection limit [1]. Surface plasmon resonance (SPR) biosensors have been widely studied for localized RI sensing [12,13], and they are commercially available. SPR biosensors can provide high sensitivity S but the large absorption in metal leads to low Q. Photonic crystal (PhC) devices, such as localized PhC defect cavities [3,14,15,16], slotted PhC cavities [17,18,19,20], and free-space coupled defect-free photonic crystal slabs (PCS) [4,7,21,22,23,24,25], have been widely explored for RI sensing to build compact on-chip integrated sensors with high performance. Localized PhC defect cavities offer a moderately high Q of 104 to 105, but small overlap of the field with the analyte limits the sensitivity to around 100 nm/RIU [3,14,15,16]. Slotted PhC cavities can achieve higher sensitivity by increasing the mode field overlap with the analyte [20]. However, the device is sensitive to fabrication imperfections, which limits the ultimate quality factors that can be achieved in practice. High Q of 107 is possible to achieve theoretically in slotted PhC cavities [19], while a Q of 103 to 104 has been demonstrated experimentally [17,18,20]. In order to couple the light from fiber into the on-chip waveguide for localized defect and slotted PhC cavities, delicate alignment is typically required to reduce the coupling loss. Additionally, sensor response time could be negatively impacted by the slow diffusion of analytes to the sub-micrometer sized defect cavities and slot region.
Fano resonances in the PCS structures could be excited efficiently by the external light that is vertically incident on the PCS [26,27,28,29]. A bound state in the continuum (BIC) are waves that coexist with the continuous radiation spectrum, remaining perfectly confined without any radiation [30,31]. BICs exist in one dimensional (1D) and two dimensional (2D) photonic crystals at wave vector k ≈ 0 and some discrete k points with infinite lifetime and infinite Q [32,33,34,35]. Fabry-Perot BICs can be formed in coupled bi-layer PCS by choosing an appropriate spacing between the two slabs [30,35,36]. An extremely high Q can be achieved when coupling to these perturbed BICs by tilting the light away from the surface-normal direction [26,32,33], or tuning the spacing between coupled bi-layer PCS [35,36,37]. In a previous study, we demonstrated experimental result of RI sensing with high-Q BIC at k ≈ 0 [22], with a quality factor of 3.2 × 104 and a low detection limit ~3 × 10−5 RIU.
In this work, we propose single-layer and coupled bi-layer PCS structures to achieve simultaneous high Q and high S based on BIC in free-space coupled PCS. By engineering the parameters of the PCS and the light incident angle, the theoretical Q of the resonance is tunable in a wide range from a few hundred to infinity. We study the high Q condition in each proposed device structure and discuss several designs that are easy to maintain extremely high Q (>107), taking into consideration the experimental implementation challenges. The designs presented in this work are promising platforms to achieve extremely low detection limits for RI sensing in practice.

2. Device Structure and Computational Methods

Figure 1a shows the schematic of a single-layer Fano resonance square lattice PCS sensor, where key design parameters are defined as lattice period (a), air hole radius (r), and thicknesses of the Si PCS (t). As shown in Figure 1a, two angles are defined to represent the propagation direction of the incident beam, the incident angle θ (the angle between incident beam and the surface-normal z axis) and the azimuth angle φ (the angle between the positive x-axis and the incident beam projection in the xy plane). The Si PCS is immersed in symmetric aqueous analyte (RI = 1.33), which also fill the air holes. The refractive index of Si is taken as 3.48. A portion of the incident light gets reflected back and the other portion of light gets transmitted through the PCS, neglecting the absorption in the analyte and the PCS. The second configuration consists of two Si PCS separated with an air gap distance tg, as shown in Figure 1b. The thickness of the top Si PCS is t1 and the bottom Si PCS is t2. The coupled PCS is immersed in analyte with the air hole and air gap filled with analyte.
Reflection spectra of the PCS are simulated with a Fourier Modal Method (FMM) based software package Stanford Stratified Structure Solver (S4) [38]. The simulation of angular dependence of the modes is similar to our previous work [39,40]. One unit cell of the PCS is simulated in S4. Spectral sensitivity (∆λ/∆nanalyte) is calculated by tracking Fano resonance shift for the PCS structure with a different RI of analyte. The quality factor is calculated by performing Fano fitting of the simulated spectra [41]. The polarization of the incident beam is defined with respect to the incident plane, as shown in Figure 1. The transverse electric (TE) polarized beam has an electric field perpendicular to the incident plane, and the transverse magnetic (TM) polarized beam has an electric field parallel to the incident plane.
Field distribution is computed with a finite-difference time-domain (FDTD) based software MEEP [42]. A unit cell of the PCS was simulated with excitation of a planar Gaussian source. Small changes in the RI of the analyte in the vicinity of the PCS will cause a spectral shift of the Fano resonances, with a relation of first-order approximation between the spectral shift and the RI change based on perturbation theory [43]. The optical overlap integral f can be defined as the ratio of electric field energy in the analyte region to the total energy for a given mode [24].
f = V a n a l y t e ε | E | 2 d v V t o t a l ε | E | 2 d v
where ε is the material dielectric constant, and E is the electric field. The bulk spectral sensitivity S and the optical overlap of integral f can be related through the following equation
S = Δ λ 0 Δ n a n a l y t e = λ 0 f n a n a l y t e
where λ0 is the resonance wavelength and nanalyte is the refractive index of the analyte. We calculated f from the field distribution with MEEP based on Equation (1) and then derive the sensitivity from Equation (2), which is consistent with the result calculated from the resonance spectral tracking using S4.

3. Simulation Results

3.1. Single Layer PCS

3.1.1. Case S1: Surface-Normal Incidence

The single-layer Si PCS consists of square lattice with period a = 1000 nm, and the thickness of the Si PCS t = 160 nm. The reflection spectra for the single-layer PCS with a hole radius of 100 nm and 200 nm under surface-normal incidence (θ = 0°) are plotted out in Figure 2a. Azimuth angle φ has no effect on the reflectance spectrum of the PCS at surface-normal incidence due to 90-degree rotational symmetry [44]. The spectral feature for the resonances becomes sharper when r reduces from 200 nm to 100 nm. The Q of the resonances, extracted from the Fano-fitting [41], is 10,940 and 1654 for r = 100 nm and r = 200 nm, respectively. The sensitivity was calculated with the equation S = ∆λ/∆n by tracking the resonance shift at two different refractive indices—n = 1.33 and n = 1.34—for the aqueous analyte solution. As shown in Figure 2b, the resonance Q factor increases with the decrease of the radius. On the other hand, the sensitivity S only decreases slightly from 860 nm/RIU to 815 nm/ RIU when the radius decreases from 300 nm to 10 nm.
The energy distribution ε|E|2 of the field at resonance wavelength was computed to estimate the optical integral f in the analyte region. Figure 3a shows the ε|E|2 distribution at the center of the Si PCS (z = 0) in the xy plane, which shows almost no field distribution in the hole region. The ε|E|2 distribution at the center of the hole in the yz plane is shown in Figure 3b. To calculate the amount of field energy in the analyte region, we integrated ε|E|2 in one unit cell along the z axis, which is plotted in Figure 3c. The blue shaded area is the Si PCS region. As analyte exists above and below the PCS, the calculated optical integral f in analyte is 0.733. The sensitivity is estimated to be 839 nm/RIU from Equation (2), which agrees well with the sensitivity of 830 nm/RIU calculated from resonance spectral tracking using S4.

3.1.2. Case S2: Near Surface-Normal Incidence

If the incident angle θ of the beam is not strictly zero, the symmetry is broken. At Γ point (k = 0, θ = 0°), square lattice possesses a symmetry group of C. If it moves from Γ point to X point (θ ≠ 0°, φ = 0°), the symmetry group changes to C1h [45]. As shown in the inset of Figure 4a, the mode existing at θ = 0° splits into two modes, B and D. Two new modes A and C emerge in the spectra when θ is non-zero. They are symmetry-protected BIC at θ = 0° because there is a symmetry mismatch between them and the radiation modes [23,33]. Modes A, B, and C can be excited by source with TM polarization, while mode D can be excited by a source with TE polarization. Sensitivity of the four modes are plotted in Figure 4b. Mode A has lower sensitivity at larger angles, while mode C has higher sensitivity at larger angles. Sensitivity for modes B and D remains relatively unchanged in the incident angle range of 0–5°.
Figure 5a shows the calculated quality factor with Fano fitting of the four modes at φ = 0° from the simulated reflection spectra. Modes B and D have a Q around 104 at θ ≈ 0°, while the singly degenerate modes A and C have infinite Q when θ ≈ 0°. Figure 5b shows a zoom-in view of the Q for the four modes at small incident angles. Modes A and C have Q > 107 in the incident angle range of 0–0.01°. When the azimuth angle φ is not zero, modes A and C occur at slightly different wavelengths in the reflection spectrum, but the quality factors for them are not affected much by the azimuth angle.

3.1.3. Case S3: Specific Incident Angle

As we can see from Figure 5c, mode B has an extremely high Q at around 3.52°, where it becomes a quasi-bound state. Unlike the symmetry-protected BIC for mode A and C at k ≈ 0, the high-Q resonance for mode B is due to the destructive interference between the leakage channels above and below the PCS [32]. Mode B can achieve Q > 107 in the incident angle range of 3°–4.2° when φ = 0°. When the radius r increases from 100 nm to 200 nm, the bound state for mode B occurs at an incident angle ~5.91°, as shown in Figure 5d. The results suggest that the BIC is robust. Small variations in device parameters (such as radius of the hole) only change the bound state to a different k value (or incident angle in this case).
Unlike modes A and C, mode B splits to two modes B1 and B2 when the azimuth angle φ is not zero, as shown in Figure 6a. The quality factor reduces for mode B1 when azimuth angle increases, as indicated in Figure 6b. Mode B2 has lower Q than B1 and it is not discussed here. For mode B1 to achieve Q > 107, the azimuth angle φ needs to be in the range of 0°–0.02°.

3.2. Coupled Bi-Layer PCS

The schematic of the coupled bi-layer PCS is shown in Figure 1b. The coupled bi-layer PCS is immersed in aqueous solution with RI of 1.33. The 2D Si PCS has a square lattice with period a = 1000 nm and a hole radius r = 100 nm. The thickness of top Si PCS t1 and bottom Si PCS t2 are both 80 nm. The gap distance tg affects the mode coupling between the top and bottom PCS [36]. We simulated the bi-layer PCS structure under surface-normal incidence condition with S4 software. The reflection spectra for the bi-layer PCS with gap distances tg of 110, 115, and 120 nm are plotted out in Figure 7a. Fano-fitting of the reflection spectrum for the coupled bi-layer PCS with tg = 115 nm shows a quality factor of 3.44 × 107, as shown in Figure 7b.
We further studied quality factor of the Fano resonance dependence on the bi-layer gap distance in Figure 8a. The Fabry–Pérot BIC forms at gap distance tg around 114.7 nm. The top and bottom PCS act as a pair of perfect mirrors that trap waves between them. The bound state has an infinite Q and it cannot be observed in the spectrum. When the gap distance is slightly off, the bound state is perturbed, and it can couple to the external radiation mode with extremely high Q. The bulk sensitivity decreases from 950 nm/RIU to 880 nm/RIU when the gap distance increases from 100 nm to 120 nm, as shown in Figure 8b.
We computed the field distribution for the coupled bi-layer PCS with tg = 115 nm using FDTD method. Figure 9a shows the electric field energy profile at the center of the top PCS (z = 100 nm) in the xy plane. The field energy distribution at the center of the hole in the yz plane is shown in Figure 9b. The field is largely concentrated in the gap region between the top and bottom PCS, with large extension to the media above and below the slab. The integrated field energy in one unit cell is plotted in Figure 9c. The optical overlap integral f in the gap analyte region is around 0.33, while f is around 0.26 in the analyte region above the top PCS or beneath the bottom PCS. The total optical overlap integral f in the analyte outside the Si PCS is around 0.85. The sensitivity could be estimated to be 930 nm/RIU based on Equation (2). The sensitivity calculated from spectral resonance tracking is around 925 nm/RIU, which agrees with the calculated sensitivity from optical field overlap integral f.

4. Experimental Results

As a proof-of-concept to the theoretical studies, we experimentally demonstrate one single-layer PCS design, which represents the Case S2 (near surface-normal incidence case) discussed in Section 3. We fabricated the single layer PCS on silicon on insulator (SOI) substrate with electron beam lithography (EBL) and dry etching with HBr/Cl2 gases. The top Si device layer thickness is 250 nm and the buried oxide thickness is 3 μm. The top view and cross-sectional view scanning electron microscope (SEM) images are shown in Figure 10a. The device was characterized with the cross-polarization technique as detailed in a previous work [23]. The measured and simulated resonance locations of the four modes at different incident angle from 0.1° to 5° are plotted in Figure 10b. The measured results agree well with the simulation results.
The reflection spectrum of single layer PCS immersed in water at near surface-normal incidence (Case S2) is shown in Figure 11a. The measured quality factor of mode 1 (M1) is 1.2 × 104 obtained from Lorentzian fitting, which is limited by water absorption in the 1400–1600 nm region (imaginary part of the refractive index of water, ni, is around 10−4) [46]. The simulation in Section 3 only considers the radiation loss (Qrad) in the structure, while neglecting the material absorption loss and the scattering loss. If the scattering loss is negligible in experiment, the total loss can be related to the radiation loss and material loss by the following equation 1/Qtotal = 1/Qrad + 1/Qabs [47]. Absorption of Si is negligible in the 1400–1600 nm range, and thus Qabs is mainly due to water absorption and it can be calculated as Qabs = nr/2fni, where nr is the real part of the refractive index of water (nr = 1.33 at 1400–1600 nm), and f is the optical overlap integral as defined in Equation (1), which is around 0.11 for the measured single layer PCS. Qabs can be estimated to be 6 × 104 which is the upper bound for the Qtotal.
Ethanol/deionized (DI) water mixture with different concentrations (0.1–0.4% volume ratio) were injected into the polydimethylsiloxane (PDMS) microfluidic channel bonded on the device to test the resonance shift of mode M1. The sensorgram of mode M1 with 0.1%, 0.25%, and 0.4% ethanol/DI water mixture are shown in Figure 11b. DI water was used to rinse the PDMS chamber after each test run of ethanol/DI water mixture. In the inset of Figure 11b, the spectral shift of mode M1 is plotted with respect to RI change of the analyte above the PCS surface. The 0.1% ethanol/DI water mixture has a 6 × 10−5 RIU RI change compared to DI water and induced around 5 pm spectral shift, which can be clearly distinguished. The bulk sensitivity is 94 nm/RIU obtained from the linear fitting of the measured results. The sensitivity could be increased by decreasing the PCS thickness and suspending the single layer PCS in the analyte solution so that a larger optical field will interact with the analyte. As discussed in Section 3, the sensitivity for single layer PCS can be as high as 800 nm/RIU with the optimized design.

5. Discussion

All the four cases discussed in this work can achieve high Q and S simultaneously. Detection limit can be estimated from Q and S. Spectral linewidth δλ is related to resonance wavelength λ0 and Q by δλ = λ0/Q. Assume a spectral resolution R’ as 1/20th of the spectral linewidth [2,48], we can achieve DL = R/S~10−8 RIU, with Q = 107 and S = 800 nm/RIU at λ0~1550 nm. The requirements in each configuration studied in this work to achieve Q = 107 and S = 800 nm/RIU are summarized in Table 1. For single layer PCS at surface-normal incidence (case S1), the radius of the hole needs to be less than 15 nm to have DL < 10−8 RIU. For coupled bi-layer PCS to achieve DL < 10−8 RIU at surface-normal incidence, the gap distance tg is required to be in less than 0.5 nm away from 114.7 nm. Small hole size or high accuracy in gap distance and PCS thickness control are challenging in terms of fabrication of the device. For single layer PCS with oblique incident light (case S2 and S3), the hole size can be relatively large. DL < 10−8 RIU can be achieved for hole radius of 100–200 nm by controlling the incident angle and the azimuth angle. Case S3 has larger incident angle tolerance than case S2. It can maintain high Q > 107 in an incident angle range of 3°–4.2° with φ = 0°. The larger incident angle range to maintain high Q is beneficial in relaxing the optical alignment requirement in practical sensor systems, as typically the incident Gaussian beam consists of a spread of k points (or incident angle) related to the lateral size of the beam [32]. However, case S3 has less tolerance in terms of azimuth angle compared to case S2. In case S2, quality factors of mode A and C are not affected much when azimuth angle φ is not zero, while φ needs to be less than 0.02° for mode B in case S3 to achieve Q > 107. In experiment, the azimuth angle can be controlled by rotating the sample stage or adjusting the principle axis of the linear polarizer to control the polarization direction of the incident beam.
If we tune the incident angle for coupled bi-layer PCS, the dependence of Q on incident angle for the four modes shows a similar trend as that for the single-layer PCS. For one coupled bi-layer PCS design with t1 = t2 = tg = 80 nm, a = 1000 nm, and r = 100 nm, mode A and C have extremely high Q at θ ~0°, while mode B can achieve near infinite Q at an incident angle of ~3°. The result suggests that the approaches to achieve high Q in single layer PCS by tuning incident angle also apply to coupled bi-layer PCS.
In biochemical sensing experiments, aqueous solution has a large absorption in the 1400–1600 nm range. For the two proposed PCS structures in Section 3, single layer PCS and coupled bi-layer PCS, high sensitivity is attributed to the large optical overlap integral with the analyte. However, a large optical overlap integral results in higher absorption loss, which limits the ultimate Q factor in experiment through Qabs, although Qrad can go up to 107 for both cases. Therefore, Q and S are trade-offs in biochemical sensors in the 1400–1600 nm region. To fully take advantage of the extremely high Q of the silicon-based PCS, aqueous solution with lower absorption loss can be used, such as deuterium oxide [49]. Nevertheless, the principles discussed in this work are applicable to PCS structures fabricated with other materials, such as Si3N4 and TiO2, for biochemical sensing in the visible wavelength region (400–800 nm), where water absorption is three orders of magnitude lower than that in the 1400–1600 nm region.

6. Conclusions

In this work, we have presented the designs of single-layer and coupled bi-layer PCS based on BIC to achieve high Q and high S at the same time. A theoretical high Q of 107 and S of 800 nm/RIU (DL~10−8 RIU) were achieved by tuning the hole radius, the incident angle, and azimuth angle of the light for single-layer PCS. In the case of coupled bi-layer PCS, the separation distance between the top and the bottom PCS is varied and investigated to achieve high Q and S. Trade-offs of different designs are investigated thoroughly for practical implementation. One non-optimal design of single-layer PCS was fabricated and characterized as a proof-of-concept, where we demonstrated a sensitivity of 94 nm/RIU and a quality factor of 1.2 × 104, with a detection limit of 6 × 10−5 RIU. The sensing performance of the BIC-based PhC resonators is superior to traditional PhC designs because of lower radiation loss and stronger light interaction between the mode and the analyte. The compact defect-free PCS sensor platform with low detection limit provides new approaches to real-time and on-chip biosensing with microfluidics integration.

Acknowledgments

This work was supported by US NSF under Grant No. ECCS-1407947 and US ARO W911NF-15-1-0431.

Author Contributions

Y.S. and W.Z. designed the research; Y.L. performed the research; Y.L., Y.S. and W.Z. analyzed the data; and all authors contributed in writing the paper.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Fan, X.; White, I.M.; Shopova, S.I.; Zhu, H.; Suter, J.D.; Sun, Y. Sensitive optical biosensors for unlabeled targets: A review. Anal. Chim. Acta 2008, 620, 8–26. [Google Scholar] [CrossRef] [PubMed]
  2. White, I.M.; Fan, X. On the performance quantification of resonant refractive index sensors. Opt. Express 2008, 16, 1020–1028. [Google Scholar] [CrossRef] [PubMed]
  3. Lee, M.; Fauchet, P.M. Two-dimensional silicon photonic crystal based biosensing platform for protein detection. Opt. Express 2007, 15, 4530–4535. [Google Scholar] [CrossRef] [PubMed]
  4. Cunningham, B.; Lin, B.; Qiu, J.; Li, P.; Pepper, J.; Hugh, B. A plastic colorimetric resonant optical biosensor for multiparallel detection of label-free biochemical interactions. Sens. Actuators B Chem. 2002, 85, 219–226. [Google Scholar] [CrossRef]
  5. Block, I.D.; Chan, L.L.; Cunningham, B.T. Photonic crystal optical biosensor incorporating structured low-index porous dielectric. Sens. Actuators B Chem. 2006, 120, 187–193. [Google Scholar] [CrossRef]
  6. Guo, Y.; Ye, J.Y.; Divin, C.; Huang, B.; Thomas, T.P.; Baker, J.J.R.; Norris, T.B. Real-Time biomolecular binding detection using a sensitive photonic crystal biosensor. Anal. Chem. 2010, 82, 5211–5218. [Google Scholar] [CrossRef] [PubMed]
  7. Magnusson, R.; Wawro, D.; Zimmerman, S.; Ding, Y. Resonant photonic biosensors with polarization-based multiparametric discrimination in each channel. Sensors 2011, 11, 1476. [Google Scholar] [CrossRef] [PubMed]
  8. Chan, L.L.; Gosangari, S.L.; Watkin, K.L.; Cunningham, B.T. Label-free imaging of cancer cells using photonic crystal biosensors and application to cytotoxicity screening of a natural compound library. Sens. Actuators B Chem. 2008, 132, 418–425. [Google Scholar] [CrossRef]
  9. Sun, Y.; Shopova, S.I.; Frye-Mason, G.; Fan, X. Rapid chemical-vapor sensing using optofluidic ring resonators. Opt. Lett. 2008, 33, 788–790. [Google Scholar] [CrossRef] [PubMed]
  10. Lai, W.-C.; Chakravarty, S.; Wang, X.; Lin, C.; Chen, R.T. On-chip methane sensing by near-IR absorption signatures in a photonic crystal slot waveguide. Opt. Lett. 2011, 36, 984–986. [Google Scholar] [CrossRef] [PubMed]
  11. Sun, Y.; Fan, X. Analysis of ring resonators for chemical vapor sensor development. Opt. Express 2008, 16, 10254–10268. [Google Scholar] [CrossRef] [PubMed]
  12. Anker, J.N.; Hall, W.P.; Lyandres, O.; Shah, N.C.; Zhao, J.; Van Duyne, R.P. Biosensing with plasmonic nanosensors. Nat. Mater. 2008, 7, 442–453. [Google Scholar] [CrossRef] [PubMed]
  13. Shankaran, D.R.; Gobi, K.V.; Miura, N. Recent advancements in surface plasmon resonance immunosensors for detection of small molecules of biomedical, food and environmental interest. Sens. Actuators B Chem. 2007, 121, 158–177. [Google Scholar] [CrossRef]
  14. Lai, W.-C.; Chakravarty, S.; Zou, Y.; Guo, Y.; Chen, R.T. Slow light enhanced sensitivity of resonance modes in photonic crystal biosensors. Appl. Phys. Lett. 2013, 102, 041111. [Google Scholar] [CrossRef] [PubMed]
  15. Kang, C.; Phare, C.T.; Vlasov, Y.A.; Assefa, S.; Weiss, S.M. Photonic crystal slab sensor with enhanced surface area. Opt. Express 2010, 18, 27930–27937. [Google Scholar] [CrossRef] [PubMed]
  16. Dorfner, D.; Zabel, T.; Hürlimann, T.; Hauke, N.; Frandsen, L.; Rant, U.; Abstreiter, G.; Finley, J. Photonic crystal nanostructures for optical biosensing applications. Biosens. Bioelectron. 2009, 24, 3688–3692. [Google Scholar] [CrossRef] [PubMed]
  17. Scullion, M.G.; Di Falco, A.; Krauss, T.F. Slotted photonic crystal cavities with integrated microfluidics for biosensing applications. Biosens. Bioelectron. 2011, 27, 101–105. [Google Scholar] [CrossRef] [PubMed]
  18. Yang, D.; Kita, S.; Liang, F.; Wang, C.; Tian, H.; Ji, Y.; Lončar, M.; Quan, Q. High sensitivity and high Q-factor nanoslotted parallel quadrabeam photonic crystal cavity for real-time and label-free sensing. Appl. Phys. Lett. 2014, 105, 063118. [Google Scholar] [CrossRef]
  19. Yang, D.; Tian, H.; Ji, Y.; Quan, Q. Design of simultaneous high-Q and high-sensitivity photonic crystal refractive index sensors. J. Opt. Soc. Am. B 2013, 30, 2027–2031. [Google Scholar] [CrossRef]
  20. Wang, B.; Dündar, M.A.; Nötzel, R.; Karouta, F.; He, S.; van der Heijden, R.W. Photonic crystal slot nanobeam slow light waveguides for refractive index sensing. Appl. Phys. Lett. 2010, 97, 151105. [Google Scholar] [CrossRef]
  21. Nicolaou, C.; Lau, W.T.; Gad, R.; Akhavan, H.; Schilling, R.; Levi, O. Enhanced detection limit by dark mode perturbation in 2D photonic crystal slab refractive index sensors. Opt. Express 2013, 21, 31698–31712. [Google Scholar] [CrossRef] [PubMed]
  22. Wang, S.; Liu, Y.; Zhao, D.; Yang, H.; Zhou, W.; Sun, Y. Optofluidic Fano resonance photonic crystal refractometric sensors. Appl. Phys. Lett. 2017, 110, 091105. [Google Scholar] [CrossRef]
  23. Liu, Y.; Wang, S.; Zhao, D.; Zhou, W.; Sun, Y. High quality factor photonic crystal filter at k~0 and its application for refractive index sensing. Opt. Express 2017, 25, 10536–10545. [Google Scholar] [CrossRef] [PubMed]
  24. El Beheiry, M.; Liu, V.; Fan, S.; Levi, O. Sensitivity enhancement in photonic crystal slab biosensors. Opt. Express 2010, 18, 22702–22714. [Google Scholar] [CrossRef] [PubMed]
  25. Wang, S.; Liu, Y.; Zhao, D.; Shuai, Y.; Yang, H.; Zhou, W.; Sun, Y. Optofluidic double-layer fano resonance photonic crystal slab liquid sensors. In Proceedings of the CLEO: Science and Innovations 2015, San Jose, CA, USA, 10 May 2015. [Google Scholar]
  26. Fan, S.; Joannopoulos, J.D. Analysis of guided resonances in photonic crystal slabs. Phys. Rev. B 2002, 65, 235112. [Google Scholar] [CrossRef]
  27. Johnson, S.G.; Fan, S.; Villeneuve, P.R.; Joannopoulos, J.D.; Kolodziejski, L.A. Guided modes in photonic crystal slabs. Phys. Rev. B 1999, 60, 5751–5758. [Google Scholar] [CrossRef]
  28. Magnusson, R.; Wang, S.S. New principle for optical filters. Appl. Phys. Lett. 1992, 61, 1022–1024. [Google Scholar] [CrossRef]
  29. Zhou, W.; Zhao, D.; Shuai, Y.-C.; Yang, H.; Chuwongin, S.; Chadha, A.; Seo, J.-H.; Wang, K.X.; Liu, V.; Ma, Z.; et al. Progress in 2D photonic crystal Fano resonance photonics. Prog. Quantum Electron. 2014, 38, 1–74. [Google Scholar] [CrossRef]
  30. Hsu, C.W.; Zhen, B.; Stone, A.D.; Joannopoulos, J.D.; Soljačić, M. Bound states in the continuum. Nat. Rev. Mater. 2016, 1, 16048. [Google Scholar] [CrossRef]
  31. Zhen, B.; Hsu, C.W.; Lu, L.; Stone, A.D.; Soljačić, M. Topological Nature of Optical Bound States in the Continuum. Phys. Rev. Lett. 2014, 113, 257401. [Google Scholar] [CrossRef] [PubMed]
  32. Hsu, C.W.; Zhen, B.; Lee, J.; Chua, S.-L.; Johnson, S.G.; Joannopoulos, J.D.; Soljacic, M. Observation of trapped light within the radiation continuum. Nature 2013, 499, 188–191. [Google Scholar] [CrossRef] [PubMed]
  33. Lee, J.; Zhen, B.; Chua, S.-L.; Qiu, W.; Joannopoulos, J.D.; Soljačić, M.; Shapira, O. Observation and differentiation of unique high-Q optical resonances near zero wave vector in macroscopic photonic crystal slabs. Phys. Rev. Lett. 2012, 109, 067401. [Google Scholar] [CrossRef] [PubMed]
  34. Yoon, J.W.; Song, S.H.; Magnusson, R. Critical field enhancement of asymptotic optical bound states in the continuum. Sci. Rep. 2015, 5, 18301. [Google Scholar] [CrossRef] [PubMed]
  35. Li, L.; Yin, H. Bound States in the Continuum in double layer structures. Sci. Rep. 2016, 6, 26988. [Google Scholar] [CrossRef] [PubMed]
  36. Liu, V.; Povinelli, M.; Fan, S. Resonance-enhanced optical forces between coupled photonic crystal slabs. Opt. Express 2009, 17, 21897–21909. [Google Scholar] [CrossRef] [PubMed]
  37. Shuai, Y.; Zhao, D.; Tian, Z.; Seo, J.-H.; Plant, D.V.; Ma, Z.; Fan, S.; Zhou, W. Double-layer Fano resonance photonic crystal filters. Opt. Express 2013, 21, 24582–24589. [Google Scholar] [CrossRef] [PubMed]
  38. Liu, V.; Fan, S. S4 : A free electromagnetic solver for layered periodic structures. Comput. Phys. Commun. 2012, 183, 2233–2244. [Google Scholar] [CrossRef]
  39. Qiang, Z.; Yang, H.; Chen, L.; Pang, H.; Ma, Z.; Zhou, W. Fano filters based on transferred silicon nanomembranes on plastic substrates. Appl. Phys.Lett. 2008, 93, 061106. [Google Scholar] [CrossRef]
  40. Chen, L.; Qiang, Z.; Yang, H.; Pang, H.; Ma, Z.; Zhou, W. Polarization and angular dependent transmissions on transferred nanomembrane Fano filters. Opt. Express 2009, 17, 8396–8406. [Google Scholar] [CrossRef] [PubMed]
  41. Luk’yanchuk, B.; Zheludev, N.I.; Maier, S.A.; Halas, N.J.; Nordlander, P.; Giessen, H.; Chong, C.T. The Fano resonance in plasmonic nanostructures and metamaterials. Nat. Mater. 2010, 9, 707–715. [Google Scholar] [CrossRef] [PubMed]
  42. Oskooi, A.F.; Roundy, D.; Ibanescu, M.; Bermel, P.; Joannopoulos, J.D.; Johnson, S.G. Meep: A flexible free-software package for electromagnetic simulations by the FDTD method. Comput. Phys. Commun. 2010, 181, 687–702. [Google Scholar] [CrossRef]
  43. Yu, Z.; Fan, S. Extraordinarily high spectral sensitivity in refractive index sensors using multiple optical modes. Opt. Express 2011, 19, 10029–10040. [Google Scholar] [CrossRef] [PubMed]
  44. Lousse, V.; Suh, W.; Kilic, O.; Kim, S.; Solgaard, O.; Fan, S. Angular and polarization properties of a photonic crystal slab mirror. Opt. Express 2004, 12, 1575–1582. [Google Scholar] [CrossRef] [PubMed]
  45. Sakoda, K. Optical Properties of Photonic Crystals; Springer: Berlin, Germany, 2005. [Google Scholar]
  46. Hale, G.M.; Querry, M.R. Optical Constants of Water in the 200-nm to 200-μm Wavelength Region. Appl. Opt. 1973, 12, 555–563. [Google Scholar] [CrossRef] [PubMed]
  47. Xu, T.; Wheeler, M.S.; Ruda, H.E.; Mojahedi, M.; Aitchison, J.S. The influence of material absorption on the quality factor of photonic crystal cavities. Opt. Express 2009, 17, 8343–8348. [Google Scholar] [CrossRef] [PubMed]
  48. Arnold, S.; Khoshsima, M.; Teraoka, I.; Holler, S.; Vollmer, F. Shift of whispering-gallery modes in microspheres by protein adsorption. Opt. Lett. 2003, 28, 272–274. [Google Scholar] [CrossRef] [PubMed]
  49. Armani, A.M.; Armani, D.K.; Min, B.; Vahala, K.J.; Spillane, S.M. Ultra-high-Q microcavity operation in H2O and D2O. Appl. Phys. Lett. 2005, 87, 151118. [Google Scholar] [CrossRef]
Figure 1. Schematic and key design parameters of the proposed sensor structures, with angle and polarization defined for incident light beam: (a) Single layer PCS, where a is the lattice constant, r is the hole radius, t is the Si PCS thickness, θ is the incident angle, and φ is the azimuth angle. The inset shows the Brillouin zone symmetric points in the k-space (Γ, X and M) for the photonic crystal lattice; and (b) Coupled bi-layer PCS where t1 is the top Si PCS thickness, t2 is the bottom Si PCS thickness, and tg is the air gap distance between the top and the bottom Si PCS.
Figure 1. Schematic and key design parameters of the proposed sensor structures, with angle and polarization defined for incident light beam: (a) Single layer PCS, where a is the lattice constant, r is the hole radius, t is the Si PCS thickness, θ is the incident angle, and φ is the azimuth angle. The inset shows the Brillouin zone symmetric points in the k-space (Γ, X and M) for the photonic crystal lattice; and (b) Coupled bi-layer PCS where t1 is the top Si PCS thickness, t2 is the bottom Si PCS thickness, and tg is the air gap distance between the top and the bottom Si PCS.
Sensors 17 01861 g001
Figure 2. Simulation of single-layer PCS with a = 1000 nm and t = 160 nm at surface-normal incidence (θ = 0°). (a) Reflection spectra of PCS with two different hole radiuses. (b) Quality factor and sensitivity of the Fano resonance in PCS with different hole radiuses.
Figure 2. Simulation of single-layer PCS with a = 1000 nm and t = 160 nm at surface-normal incidence (θ = 0°). (a) Reflection spectra of PCS with two different hole radiuses. (b) Quality factor and sensitivity of the Fano resonance in PCS with different hole radiuses.
Sensors 17 01861 g002
Figure 3. Simulated field distribution of the single layer PCS with a = 1000 nm, r = 100 nm, and t = 160 nm, at surface-normal incidence (θ = 0°). (a) ε|E|2 distribution at the center of the PCS in the xy plane, with boundary of the hole labeled in dashed circle. (b) ε|E|2 distribution at the center of the hole in the yz plane, with boundary of the Si PCS labeled in dashed rectangles. (c) Distribution of integrated ε|E|2 in one unit cell along vertical (z-axis) direction, with blue shaded area indicating the Si PCS.
Figure 3. Simulated field distribution of the single layer PCS with a = 1000 nm, r = 100 nm, and t = 160 nm, at surface-normal incidence (θ = 0°). (a) ε|E|2 distribution at the center of the PCS in the xy plane, with boundary of the hole labeled in dashed circle. (b) ε|E|2 distribution at the center of the hole in the yz plane, with boundary of the Si PCS labeled in dashed rectangles. (c) Distribution of integrated ε|E|2 in one unit cell along vertical (z-axis) direction, with blue shaded area indicating the Si PCS.
Sensors 17 01861 g003
Figure 4. Simulation of single-layer PCS with a = 1000 nm, r = 100 nm, and t = 160 nm at different incident angles with φ = 0°. (a) Resonance spectral location dependence on incident angle. (b) Bulk sensitivity dependence on incident angle.
Figure 4. Simulation of single-layer PCS with a = 1000 nm, r = 100 nm, and t = 160 nm at different incident angles with φ = 0°. (a) Resonance spectral location dependence on incident angle. (b) Bulk sensitivity dependence on incident angle.
Sensors 17 01861 g004
Figure 5. Study of quality factor in single-layer PCS at different incident angles with φ = 0°. Design of the PCS: a = 1000 nm, t = 160 nm, r = 100 nm in (a)–(c), and r = 200 nm in (d). Q factor of the four modes in PCS at an incident angle in the range of 0–7° (a) and at near-zero incident angles (b). Mode B at incident angles near infinite Q condition for the PCS with two different radii: r = 100 nm in (c) and r = 200 nm in (d), respectively.
Figure 5. Study of quality factor in single-layer PCS at different incident angles with φ = 0°. Design of the PCS: a = 1000 nm, t = 160 nm, r = 100 nm in (a)–(c), and r = 200 nm in (d). Q factor of the four modes in PCS at an incident angle in the range of 0–7° (a) and at near-zero incident angles (b). Mode B at incident angles near infinite Q condition for the PCS with two different radii: r = 100 nm in (c) and r = 200 nm in (d), respectively.
Sensors 17 01861 g005
Figure 6. Simulation of mode B in single-layer PCS with a = 1000 nm, r = 100 nm, and t = 160 nm at θ = 3.5°. (a) Resonance spectral location dependence on azimuth angle φ. (b) Quality factor dependence of mode B1 on azimuth angle φ.
Figure 6. Simulation of mode B in single-layer PCS with a = 1000 nm, r = 100 nm, and t = 160 nm at θ = 3.5°. (a) Resonance spectral location dependence on azimuth angle φ. (b) Quality factor dependence of mode B1 on azimuth angle φ.
Sensors 17 01861 g006
Figure 7. (a) Simulated reflection spectra of the coupled bi-layer PCS, with a = 1000 nm, t1 = t2 = 80 nm, r = 100 nm and three different gap distances, tg, at surface-normal incidence. (b) Zoom-in of the reflection spectrum of PCS with tg = 115 nm. Fano-fitting shows a Q factor of 3.44 × 107.
Figure 7. (a) Simulated reflection spectra of the coupled bi-layer PCS, with a = 1000 nm, t1 = t2 = 80 nm, r = 100 nm and three different gap distances, tg, at surface-normal incidence. (b) Zoom-in of the reflection spectrum of PCS with tg = 115 nm. Fano-fitting shows a Q factor of 3.44 × 107.
Sensors 17 01861 g007
Figure 8. Quality factor (a) and sensitivity (b) for the resonance in bi-layer PCS of a = 1000 nm, t1 = t2 = 80 nm, r = 100 nm at surface-normal incidence, with gap distance, tg, varying from 100 nm to 120 nm.
Figure 8. Quality factor (a) and sensitivity (b) for the resonance in bi-layer PCS of a = 1000 nm, t1 = t2 = 80 nm, r = 100 nm at surface-normal incidence, with gap distance, tg, varying from 100 nm to 120 nm.
Sensors 17 01861 g008
Figure 9. Simulation of field distribution of bi-layer PCS with a = 1000 nm, t1 = t2 = 80 nm, r = 100 nm, tg = 115 nm at surface-normal incidence. (a) ε|E|2 distribution at the center of the top PCS in the xy plane, with hole boundary shown in the dashed circle. (b) ε|E|2 distribution at the center of the hole in the yz plane, dashed rectangles show the boundary of top and bottom Si PCS. (c) Distribution of integrated ε|E|2 in one unit cell along vertical (z-axis) direction, with the blue shaded area showing the top and bottom Si PCS.
Figure 9. Simulation of field distribution of bi-layer PCS with a = 1000 nm, t1 = t2 = 80 nm, r = 100 nm, tg = 115 nm at surface-normal incidence. (a) ε|E|2 distribution at the center of the top PCS in the xy plane, with hole boundary shown in the dashed circle. (b) ε|E|2 distribution at the center of the hole in the yz plane, dashed rectangles show the boundary of top and bottom Si PCS. (c) Distribution of integrated ε|E|2 in one unit cell along vertical (z-axis) direction, with the blue shaded area showing the top and bottom Si PCS.
Sensors 17 01861 g009
Figure 10. (a) SEM top view and angled cross-sectional view of one single layer PCS on SOI substrate, with a zoom-in image of one air hole in the inset. The PCS parameters: a = 990 nm, r = 85 nm, and t = 250 nm. (b) Simulated and tested resonance locations for the four modes of the PCS on SOI substrate at different incident angles. Simulated data points are represented by squares and connected by solid lines, and tested data points are represented by circles and connected by dashed lines.
Figure 10. (a) SEM top view and angled cross-sectional view of one single layer PCS on SOI substrate, with a zoom-in image of one air hole in the inset. The PCS parameters: a = 990 nm, r = 85 nm, and t = 250 nm. (b) Simulated and tested resonance locations for the four modes of the PCS on SOI substrate at different incident angles. Simulated data points are represented by squares and connected by solid lines, and tested data points are represented by circles and connected by dashed lines.
Sensors 17 01861 g010
Figure 11. (a) Measured reflection spectrum of one single layer PCS immersed in water, with cross-polarizer technique. A zoom-in spectrum of mode M1 is shown in the inset. The PCS parameters: a = 970 nm, r = 85 nm, and t = 250 nm. (b) Sensorgram for injecting different concentrations of ethanol/DI water mixture and rinsing with water. The inset shows spectral shift as a function of refractive index change, and the sensitivity of the PCS is fitted to be 94 nm/RIU.
Figure 11. (a) Measured reflection spectrum of one single layer PCS immersed in water, with cross-polarizer technique. A zoom-in spectrum of mode M1 is shown in the inset. The PCS parameters: a = 970 nm, r = 85 nm, and t = 250 nm. (b) Sensorgram for injecting different concentrations of ethanol/DI water mixture and rinsing with water. The inset shows spectral shift as a function of refractive index change, and the sensitivity of the PCS is fitted to be 94 nm/RIU.
Sensors 17 01861 g011
Table 1. Summary of different approaches to achieve Q > 107, S > 800 nm/RIU and DL < 10−8 RIU in PCS sensor design.
Table 1. Summary of different approaches to achieve Q > 107, S > 800 nm/RIU and DL < 10−8 RIU in PCS sensor design.
ConfigurationCasesIncident angle θRequirement
Single layerS1Radius r < 15 nm
Single layerS2≈0°0° < θ < 0.01°
Single layerS3>0°3° < θ < 4.2°; φ < 0.02°
Bi-layer-Gap tg = 114.2–115.2 nm

Share and Cite

MDPI and ACS Style

Liu, Y.; Zhou, W.; Sun, Y. Optical Refractive Index Sensing Based on High-Q Bound States in the Continuum in Free-Space Coupled Photonic Crystal Slabs. Sensors 2017, 17, 1861. https://doi.org/10.3390/s17081861

AMA Style

Liu Y, Zhou W, Sun Y. Optical Refractive Index Sensing Based on High-Q Bound States in the Continuum in Free-Space Coupled Photonic Crystal Slabs. Sensors. 2017; 17(8):1861. https://doi.org/10.3390/s17081861

Chicago/Turabian Style

Liu, Yonghao, Weidong Zhou, and Yuze Sun. 2017. "Optical Refractive Index Sensing Based on High-Q Bound States in the Continuum in Free-Space Coupled Photonic Crystal Slabs" Sensors 17, no. 8: 1861. https://doi.org/10.3390/s17081861

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop