Article

Hierarchical NiCo2O4 Hollow Sphere as a Peroxidase Mimetic for Colorimetric Detection of H2O2 and Glucose

1
State Key Laboratory of Marine Resource Utilization in South China Sea, Key Laboratory of Tropical Biological Resources of Ministry of Education Hainan University, College of Material and Chemical Engineering, Haikou 570228, China
2
Laboratory Cultivation Base of Natural Gas Conversion, School of Chemistry and Chemical Engineering, Ningxia University, Yinchuan 750021, China
*
Author to whom correspondence should be addressed.
Sensors 2017, 17(1), 217; https://doi.org/10.3390/s17010217
Submission received: 6 December 2016 / Revised: 9 January 2017 / Accepted: 16 January 2017 / Published: 23 January 2017
(This article belongs to the Special Issue Colorimetric and Fluorescent Sensor)

Abstract

:
In this work, the hierarchical NiCo2O4 hollow sphere synthesized via a “coordinating etching and precipitating” process was demonstrated to exhibit intrinsic peroxidase-like activity. The peroxidase-like activity of NiCo2O4, NiO, and Co3O4 hollow spheres were comparatively studied by the catalytic oxidation reaction of 3,3,5,5-tetramethylbenzidine (TMB) in presence of H2O2, and a superior peroxidase-like activity of NiCo2O4 was confirmed by stronger absorbance at 652 nm. Furthermore, the proposed sensing platform showed commendable response to H2O2 with a linear range from 10 μM to 400 μM, and a detection limit of 0.21 μM. Cooperated with GOx, the developed novel colorimetric and visual glucose-sensing platform exhibited high selectivity, favorable reproducibility, satisfactory applicability, wide linear range (from 0.1 mM to 4.5 mM), and a low detection limit of 5.31 μM. In addition, the concentration-dependent color change would offer a better and handier way for detection of H2O2 and glucose by naked eye.

1. Introduction

Natural enzymes have been widely studied and applied in various fields due to their high substrate specificity and brilliant catalytic activity under mild conditions [1]. However, application of these enzymes is restricted by their high cost, complicated purification and immobilization procedures, and harsh reaction conditions [2,3]. Therefore, the low-cost enzyme mimics with good stability, excellent catalytic activity, and satisfactory selectivity were highly in demand [4]. Since Gao’s [5] first report on an intrinsic peroxidase-like activity of Fe3O4 nanoparticles, various nanomaterials such as MFe2O4 [6,7], MoS2 [8], Co3O4 [9,10], NiO [11], CuS [12], graphene oxide [13], and graphene oxide–Fe3O4 composite [14] have been further investigated as peroxidase mimetics for H2O2 detection. These researches reveal that the nanomaterial-based peroxidase mimetics possess the advantages of high specific surface area, controllable morphologies and sizes, and tunable catalytic properties that would be promising candidates for bioassays and clinical diagnosis [4,15,16].
NiCo2O4 is a typical spinal metal oxide, with Ni ions occupying the octahedral sites while Co ions are integrally distributed to both the octahedral and tetrahedral sites [17,18]. Due to its superior catalytic activity and conductivity to that of single Co3O4 or NiO [19,20], NiCo2O4 has gained great attention in the areas of supercapacitor, electrocatalyst, oxidation evolution reaction, and biosensor [21,22]. It has been reported that Co3O4 nanoparticles possess an intrinsic peroxidase-like and catalase-like activity, and NiO exhibits peroxidase-like activity as well [9,11,23]. The surface of NiCo2O4 is rich in oxidation states Ni2+/Ni3+ and Co2+/Co3+, which make it a better electron transfer mediator for peroxidase substrates (such as 3,3,5,5-tetramethylbenzidine (TMB)) and H2O2 analysis. Moreover, the superior conductivity of NiCo2O4 is conducive to improving the electron transfer kinetics within the materials. To the best of our knowledge, the study of NiCo2O4 as an enzyme mimetic remains unexplored, which greatly inspires the research interest in applying nanostructured NiCo2O4 to colorimetric detection of H2O2. Besides, it is well known that the catalytic properties of active materials seriously depend on their morphology and size, which significantly influence the surface efficiency and stability of catalysts [24,25]. The hierarchical hollow structure assembled from particle units is endowed with the advantages of high surface-to-volume ratio, ample mass diffusion pathways, and satisfactory structure stability [26,27]. Therefore, the hierarchical hollow structured NiCo2O4 materials are expected to function as highly efficient peroxidase mimetics for colorimetric detection of H2O2 and glucose.
In this paper, the hierarchical NiCo2O4 hollow sphere was prepared through a facile Cu2O-templated approach based on the “coordinating etching and precipitating” (CEP) process, and its peroxidase-like activity was investigated for the first time. Moreover, the peroxidase-like activity of the hierarchical NiCo2O4 hollow sphere was compared to that of single NiO and Co3O4 with the presence of TMB and H2O2 under parallel condition. In addition, the hierarchical NiCo2O4 hollow sphere was applied to the colorimetric detection of H2O2. Combined with glucose oxidase (GOx), a novel colorimetric and visual glucose-sensing platform was developed. Finally, the selectivity, reproducibility, and applicability of this proposed sensing platform were assessed by a standard method.

2. Experimental

2.1. Chemicals

CuCl2·2H2O, sodium dodecyl sulfate (SDS), NaOH, NH2OH·HCl, CoCl2·6H2O, Na2S2O3·5H2O, glucose, and absolute ethanol were purchased from Shanghai Sinopharm Chemical Reagent Co., Ltd. (Shanghai, China). Polyvinylpyrrolidone (PVP, K30, MW ≈ 3800) was provided by Aldrich (Shanghai, China). Citric acid monohydrate, trisodium citrate dihydrate, and 30% H2O2 were supplied by Guangzhou Chemical Reagent Factory ich (Guangzhou, China). TMB was obtained from Macklin ich (Shanghai, China). Glucose oxidase (GOx, 50 KU) was procured from Sangon Biotech (Shanghai, China) Co., Ltd. (Shanghai, China) and stored in a freezer at −20 °C. All chemical reagents were of analytical grade and were used without further purification.

2.2. Apparatus

X-ray diffraction (XRD) analysis was performed using a D8 Tools XRD instrument (Bruker, Karlsruhe, Germany) with a voltage of 40 kV and a current of 30 mA with Cu Kα radiation (k = 1.5406 Å). Field-emission scanning electron microscope (SEM) images were obtained by Hitachi S-4800. Transmission electron microscopy (TEM) micrographs were acquired using a JEOL-2100F microscope. The ζ-potential was measured using dynamic light scattering (DLS) at 25 °C (Malvern Nanosizer ZS90). X-ray photoelectron spectroscopy (XPS) data were characterized by Thermo Scientific ESCALAB250 (Thermo Scientific, Waltham, MA, USA) using Al radiation. Nitrogen sorption experiments were carried out at 77 K on a Micro Meritics Tristar II 3020 surface area and pore size analyzer (Norcross, GA, USA). Prior to the measurements, the samples were outgassed at 200 °C in vacuum for 6 h. UV–vis absorption spectra were recorded using a 723PC spectrophotometer (Shanghai Jinghua Science and Technology Co., Ltd., Shanghai, China).

2.3. Synthesis of Hierarchical NiCo2O4 Hollow Sphere

The NiCo2O4 hollow sphere was synthesized based on a “CEP” process by selecting S2O32− as etchant towards the pre-prepared Cu2O solid-sphere template. The Cu2O solid sphere was obtained according to our previous work [28]. First, 5 mg of the as-prepared Cu2O nanospheres, 1.13 mg of CoCl2·6H2O, 0.57 mg of NiCl2·6H2O, and 0.33 g of PVP were dissolved into a mixed solution (Vethanol:Vwater = 1:1, 10 mL), stirred, and sonicated. Then, 4 mL of Na2S2O3 aqueous solution (1 M) was added dropwise into the mixture and kept stirring for about 10 min. The resulting precursor was collected by several rinse–centrifugation cycles with deionized (DI) water and ethanol. Finally, the precursor was calcinated in a muffle furnace at 300 °C for 4 h at a ramp rate of 1 °C·min−1 under the air condition.

2.4. Catalytic Oxidation of TMB

To investigate the peroxidase-like activity of NiCo2O4 hollow sphere, catalytic oxidation reaction of TMB in sodium citrate buffer solution was performed in presence of H2O2. Five microliters of 1 mg·mL−1 NiCo2O4 hollow sphere dispersion was incubated with 3 mL of pre-prepared sodium citrate buffer solution (0.1 M, pH 4.5) in the presence of H2O2 (0.02 M) and TMB (0.08 mM). The photographs and UV–vis spectra were obtained after incubation at room temperature for 30 min.

2.5. Colorimetric Detection of H2O2

Five microliters of 1 mg/mL NiCo2O4 hollow sphere dispersion, 25 μL of 10 mM TMB, and 3 μL of H2O2 in different concentrations were added to 3 mL sodium citrate buffer solution (0.1 M, pH 4.5). The UV–vis absorption spectra were recorded from 500 nm to 800 nm.

2.6. Colorimetric Detection of Glucose

Five microliters of 1 mg/mL NiCo2O4 hollow sphere dispersion, 25 μL of 10 mM TMB, 5 μL of 10 mg/mL GOx, and 3 μL of glucose in different concentrations were added to 3 mL of sodium citrate buffer solution (0.1 M, pH 4.5). The UV–vis absorption spectra were recorded from 500 nm to 800 nm.

3. Results and Discussion

3.1. Materials Characterization

The Ni–Co hydroxide precursor was synthesized via a deliberately designed “CEP” process, and the duplication and the elimination of Cu2O template were completed simultaneously within 10 min at room temperature [29,30]. The final NiCo2O4 hollow sphere product was obtained after a simple thermal treatment based on the above processes. As shown in Figure 1a, a high-quality Cu2O template with an average size of approximately 400 nm was obtained, and its rough texture on the surface was conducive to creating more chemical etching interface. From the TEM image in Figure 1b, a solid construction can be confirmed. After the etching process and thermal treatment, the obtained NiCo2O4 sphere (Figure 1c) well inherited the spherical structure of the template, indicating the controllability of the “CEP” process and the stability in structure. The “wormlike” secondary structures can be observed clearly in the magnified image in Figure 1d, and the hollow structure feature can be initially identified by the cracked sphere. Afterwards, we performed TEM characterization to further testify to the inner structure of the hierarchical sphere.
As shown in Figure 2a,b, the distinct contrast between the shells and inner space fully demonstrates the hollow construction of the hierarchical NiCo2O4 sphere. The diameter of the hollow sphere is about 400 nm, which is similar to that of pre-grown Cu2O sphere. Furthermore, the apparent bright and dark aberrations on the ultrathin shell (<30 nm) imply the existence of nanopores, and sheetlike secondary structures of several nanometers in thickness are uniformly grown on the sphere. Notably, the ultrathin hollow sphere with affluent secondary structures could provide more efficient inner and outer surface and create more catalytically active sites. The inserted selected area electron diffraction (SAED) pattern in Figure 2b reveals a polycrystalline feature of the as-prepared material. Figure 2c displays the amplified image of the selected area marked in (b), in which the nanopore and ripple structure can be identified, and the high-resolution TEM image in Figure 2d also attests to the evident crystalline structure in the NiCo2O4 hollow sphere. More detailed structure information was further determined by XRD and N2 adsorption–desorption tests.
Figure 3a depicts the typical XRD pattern of the as-prepared materials, in which all diffraction peaks can be assigned to the spinal-structured NiCo2O4 (JCPDS No. 20-0781). The peaks at 2θ values of 31°, 36°, 45°, 59°, and 65° are corresponding to (200), (311), (400), (511), and (440) crystal faces of NiCo2O4 in cubic phase [31]. No other impurity peaks appear, indicating the high purity of the samples. The porosity of the hierarchical NiCo2O4 hollow sphere was assessed by N2 adsorption–desorption test as shown in Figure 3b, which gives a typical IV-type isotherm. The specific surface area estimated by Brunauer–Emmett–Teller (BET) method is 59.4 m2·g−1, and the inserted pore size distribution curve demonstrates the existence of mesopores [32]. Apparently, the porous structure of the hierarchical NiCo2O4 hollow sphere is beneficial to supply more mass transport pathways and active sites. Furthermore, the DLS result shows that the surface of the as-obtained NiCo2O4 hollow spheres is positively charged (about 3.0 mV) in water, which is conducive to the absorption of negatively charged GOx and improves the dispersibility of the particles in the solution. Additionally, the surface composition and valence state of the hierarchical NiCo2O4 hollow sphere are also vital, since the catalytic reactions mainly happened on the surface of catalysts.
XPS was applied to study the element and valance information of NiCo2O4 hollow sphere. The survey spectrum in Figure 4a demonstrates the existence of nickel, cobalt, oxygen, and slight carbon atoms. By using a Gaussian fitting, the high-resolution spectrum of Ni 2p exhibits two spin-orbit doublets (Ni2+ and Ni3+) and two shakeup satellites (Figure 4b). The peaks at 854.2 eV and 871.9 eV are attributed to Ni2+, and the peaks at 855.8 eV and 873.5 eV can be assigned to Ni3+. The Co 2p spectrum can also be fitted into two spin-orbit doublets (Co2+ and Co3+) and two shakeup satellites (Figure 4c) in the same way. These results are well in agreement with many other reports, demonstrating the Ni2+ and Ni3+, Co2+ and Co3+ inside the NiCo2O4 hollow sphere [33]. The high-resolution spectrum of O 1s exhibits three oxygen species marked as O1, O2, and O3. Based on the previous reports, O1 (with a binding energy of 529.5 eV) was a typical metal–oxygen bond, and O2 (with a binding energy of 530.7 eV) was generally attributed to defects, impurities, and some low oxygen coordination within the spinal structure [34]. As for O3 (with a binding energy of 531.6 eV), it was associated with physi- and chemisorbed water molecules [35]. The rich surface chemical composition and valence state of the NiCo2O4 hollow sphere may lead to a large number of distributional differences in local electronic cloud density, which greatly affect the catalytic activity.

3.2. Synthesis Mechanism

Based on the above discussion, the well-designed “CEP” process has been successfully applied to the synthesis of the hierarchical porous NiCo2O4 hollow sphere. Figure 5a–d display the evolution in morphology and structure, from Cu2O solid sphere to the final hierarchical NiCo2O4 hollow sphere. Figure 5e displays the corresponding schematic illustration of the formation process. As is well known, according to the HSAB (hard and soft acids and bases) theory, Cu+ has much stronger interaction with S2O32− (soft–soft interaction) than that of O2− (soft–hard interaction). Thus, the presence of S2O32− would lead to the elimination of the Cu2O template and an increased local OH concentration on the etching interface. Besides, accompanied by the hydrolyzation of S2O32− and coprecipitation of metal ions with OH, Ni–Co hydroxide units are preferential to nucleation and growth at the etching interface to form the Ni–Co hydroxide hollow sphere (Figure 5b). It is noteworthy that both the template elimination and duplication processes can be accurately controlled by simply adjusting the ratio of water to ethanol.

3.3. Peroxidase-Like Activity of the Hierarchical NiCo2O4 Hollow Sphere

To investigate the peroxidase-like activity of the hierarchical NiCo2O4 hollow sphere, the catalysis of the peroxidase substrate TMB was performed in presence or absence of H2O2. Additionally, the peroxidase-like activities of NiO and Co3O4 hollow spheres synthesized by the same method were also studied for comparison. Thus, five controlled experiments were carried out: (i) TMB + H2O2; (ii) TMB + NiCo2O4; (iii) TMB + H2O2 + NiCo2O4; (iv) TMB + H2O2 + NiO; (v) TMB + H2O2 + Co3O4. As shown in Figure 6a, only with the coexistence of H2O2 and NiCo2O4 catalyst could beget an obvious absorption peak at 652 nm (iii) due to the oxidation of TMB, which indicates a peroxidase-like activity. As in previous reported work, both of the as-prepared NiO (iv) and Co3O4 (v) catalysts exhibited peroxidase-like activity in this research. However, the corresponding absorption spectra reveals that the hierarchical NiCo2O4 hollow sphere obviously possesses a stronger absorption peak than that of NiO and Co3O4 under the parallel condition, suggesting an enhanced peroxidase-like activity. The possible reaction mechanism is different from that of Fe-based catalysts, which are mainly conducted by the “Fenton” reaction. During this process, TMB molecules are absorbed on the surface of the hierarchical NiCo2O4 hollow sphere, and can donate lone-pair electrons from the amino groups to the catalyst [8]. That results in an increase in electron density and mobility in the NiCo2O4 hollow sphere, which would facilitate the electron transfer from the NiCo2O4 hollow sphere to H2O2 to accelerate the oxidation rate of TMB by H2O2 [9]. Furthermore, the enhanced peroxidase-like activity of the NiCo2O4 catalyst should be attributed to the diversified distribution of surface electron clouds and the hierarchical porous hollow structure that could provide ample active sites for catalytic reaction. The peroxidase-like activity of the hierarchical NiCo2O4 hollow sphere is also dependent on the TMB concentration and pH environment. As shown in Figure 6b, the absorption intensity at 652 nm was increased with the increasing of TMB, but no obvious increase was observed when the concentration was greater than 0.08 mM (25 μL), suggesting an optimized TMB concentration. Additionally, the pH-dependent peroxidase-like activity in Figure 6c indicates that the optimal pH should be 4.5.

3.4. Colorimetric Detection of H2O2

Based on the above peroxidase-like activity investigation of the hierarchical NiCo2O4 hollow sphere, a colorimetric method was developed for detection of H2O2. In Figure 7a, the absorbance at 652 nm for oxidized TMB increases with the concentration of H2O2. Figure 7b shows the corresponding linear calibration curve and photograph of color change. The linear range is from 0.01 mM to 0.4 mM, and the detection limit is calculated to be 0.21 μM. Notably, the concentration-dependent color change could offer a handy way for detection of H2O2 by naked eye.

3.5. Colorimetric Detection of Glucose

The concentration of blood glucose is an important physiological indicator for the human body. The detection of glucose is meaningful for clinical diagnosis and treatment of disease. H2O2 is one of the main intermediate products of glucose oxidase-catalyzed reaction. To take full advantage of the peroxidase-like activity of the hierarchical NiCo2O4 hollow sphere, the colorimetric detection of glucose was also developed, and the reaction mechanism is illustrated in Figure 8. As shown in Figure 9a, the absorbance at 652 nm for oxidized TMB increases with the concentration of H2O2. The corresponding linear calibration curve and photograph of color change in Figure 9b shows that the linear range is from 0.1 mM to 4.5 mM with a detection limit of 5.31 μM. It can be seen from Table 1 that the proposed catalyst performs satisfactory combination properties toward glucose sensing compared with most non-Pt-based catalysts. Even though the present NiCo2O4-based sensor exhibits slightly lower sensing performance to that of a Pt-based sensor, but it is also a low-cost and effective detection method. Moreover, the concentrations of blood glucose in healthy and diabetic persons is generally in the range of 3–8 mM and 9–40 mM, respectively [36]. Therefore, the proposed method is applicable to glucose analysis in real serum by simple dilution.

3.6. Selectivity, Reproducibility, and Applicability

The selectivity, reproducibility, and applicability of the proposed sensor for glucose detection were investigated. As shown in Figure 10, the presence of glucose apparently produced much stronger absorption intensity and color change than that of other analytes, indicating a good selectivity to glucose of this biosensor. The reproducibility was evaluated by three consecutive detections, resulting in an acceptable relative standard deviation (RSD) of 3.24%. For applicability, the sensor was applied to detect the human serum sample: the detected glucose concentration was 4.2 mM with an acceptable RSD of 4.5%, compared to the concentration of 4.4 mM determined by the hospital.

4. Conclusions

In summary, the hierarchical NiCo2O4 hollow sphere was successfully synthesized by a “coordinating etching and precipitating” process and exhibited intrinsic peroxidase-like activity. The experimental results revealed that the hierarchical NiCo2O4 hollow sphere possessed superior peroxidase-like activity to that of single NiO or Co3O4. For use as a peroxidase mimic, the proposed sensing platform showed a commendable response to H2O2 with a linear range from 10 μM to 400 μM and a detection limit of 0.21 μM. More importantly, combined with GOx, the developed glucose-sensing platform exhibited high selectivity, superb reproducibility, satisfactory applicability, wide linear range from 0.1 mM to 4.5 mM, and low detection limit of 5.31 μM. Additionally, the concentration-dependent color change could offer a handy way for detection of H2O2 and glucose by naked eye. Therefore, the hierarchical NiCo2O4 hollow sphere would be a promising candidate for colorimetric detection of H2O2 and glucose.

Acknowledgments

This research was financially supported by National Natural Science Foundation of China (No. 21301042 and 51361009) and National Basic Research Program of China (973 program, No. 2012CB9339020).

Author Contributions

Jinchun Tu conceived and designed the experiments; Wei Huang performed the experiments and analyzed the data; Jinchun Tu contributed reagents/materials/analysis tools; Wei Huang, Tianye Lin, Yang Cao, Xiaoyong Lai, Juan Peng and Jinchun Tu wrote the paper.

Conflicts of Interest

The authors declare no conflict of interest. The funding sponsors had no role in the design of the study; in the collection, analyses, or interpretation of data; in the writing of the manuscript, and in the decision to publish the results.

References

  1. Bankar, S.B.; Bule, M.V.; Singhal, R.S.; Ananthanarayan, L. Glucose oxidase—An overview. Biotechnol. Adv. 2009, 27, 489–501. [Google Scholar] [CrossRef] [PubMed]
  2. Ronkainen, N.J.; Halsall, H.B.; Heineman, W.R. Electrochemical biosensors. Chem. Soc. Rev. 2010, 39, 1747–1763. [Google Scholar] [CrossRef] [PubMed]
  3. Sun, J.; Li, C.; Qi, Y.; Guo, S.; Liang, X. Optimizing Colorimetric Assay Based on V2O5 Nanozymes for Sensitive Detection of H2O2 and Glucose. Sensors 2016, 16, 584. [Google Scholar] [CrossRef] [PubMed]
  4. Kuah, E.; Toh, S.; Yee, J.; Ma, Q.; Gao, Z. Enzyme Mimics: Advances and Applications. Chem. Eur. J. 2016, 22, 8404–8430. [Google Scholar] [CrossRef] [PubMed]
  5. Gao, L.; Zhuang, J.; Nie, L.; Zhang, J.; Zhang, Y.; Gu, N.; Wang, T.; Feng, J.; Yang, D.; Perrett, S.; et al. Intrinsic peroxidase-like activity of ferromagnetic nanoparticles. Nat. Nanotechnol. 2007, 2, 577–583. [Google Scholar] [CrossRef] [PubMed]
  6. Su, L.; Qin, W.; Zhang, H.; Rahman, Z.U.; Ren, C.; Ma, S.; Chen, X. The peroxidase/catalase-like activities of MFe2O4 (M = Mg, Ni, Cu) MNPs and their application in colorimetric biosensing of glucose. Biosens. Bioelectron. 2015, 63, 384–391. [Google Scholar] [CrossRef] [PubMed]
  7. Su, L.; Feng, J.; Zhou, X.; Ren, C.; Li, H.; Chen, X. Colorimetric Detection of Urine Glucose Based ZnFe2O4 Magnetic Nanoparticles. Anal. Chem. 2012, 84, 5753–5758. [Google Scholar] [CrossRef] [PubMed]
  8. Zhao, K.; Gu, W.; Zheng, S.; Zhang, C.; Xian, Y. SDS–MoS2 nanoparticles as highly-efficient peroxidase mimetics for colorimetric detection of H2O2 and glucose. Talanta 2015, 141, 47–52. [Google Scholar] [CrossRef] [PubMed]
  9. Mu, J.; Wang, Y.; Zhao, M.; Zhang, L. Intrinsic peroxidase-like activity and catalase-like activity of Co3O4 nanoparticles. Chem. Commun. 2012, 48, 2540–2542. [Google Scholar] [CrossRef] [PubMed]
  10. Zhang, Z.; Hao, J.; Yang, W.; Lu, B.; Ke, X.; Zhang, B.; Tang, J. Porous Co3O4 Nanorods-Reduced Graphene Oxide with Intrinsic Peroxidase-Like Activity and Catalysis in the Degradation of Methylene Blue. ACS Appl. Mater. Interfaces 2013, 5, 3809–3815. [Google Scholar] [CrossRef] [PubMed]
  11. Ray, C.; Dutta, S.; Sarkar, S.; Sahoo, R.; Roy, A.; Pal, T. Intrinsic peroxidase-like activity of mesoporous nickel oxide for selective cysteine sensing. J. Mater. Chem. B 2014, 2, 6097–6105. [Google Scholar] [CrossRef]
  12. Dutta, A.K.; Das, S.; Samanta, S.; Samanta, P.K.; Adhikary, B.; Biswas, P. CuS nanoparticles as a mimic peroxidase for colorimetric estimation of human blood glucose level. Talanta 2013, 107, 361–367. [Google Scholar] [CrossRef] [PubMed]
  13. Song, Y.; Qu, K.; Zhao, C.; Ren, J.; Qu, X. Graphene Oxide: Intrinsic Peroxidase Catalytic Activity and Its Application to Glucose Detection. Adv. Mater. 2010, 22, 2206–2210. [Google Scholar] [CrossRef] [PubMed]
  14. Dong, Y.-L.; Zhang, H.-G.; Rahman, Z.U.; Su, L.; Chen, X.-J.; Hu, J.; Chen, X.-G. Graphene oxide-Fe3O4 magnetic nanocomposites with peroxidase-like activity for colorimetric detection of glucose. Nanoscale 2012, 4, 3969–3976. [Google Scholar] [CrossRef] [PubMed]
  15. Ragg, R.; Tahir, M.N.; Tremel, W. Solids Go Bio: Inorganic Nanoparticles as Enzyme Mimics. Eur. J. Inorg. Chem. 2016, 2016, 1906–1915. [Google Scholar] [CrossRef]
  16. Liu, B.; Han, X.; Liu, J. Iron oxide nanozyme catalyzed synthesis of fluorescent polydopamine for light-up Zn2+ detection. Nanoscale 2016, 8, 13620–13626. [Google Scholar] [CrossRef] [PubMed]
  17. Verma, S.; Joshi, H.M.; Jagadale, T.; Chawla, A.; Chandra, R.; Ogale, S. Nearly Monodispersed Multifunctional NiCo2O4 Spinel Nanoparticles: Magnetism, Infrared Transparency, and Radiofrequency Absorption. J. Phys. Chem. C 2008, 112, 15106–15112. [Google Scholar] [CrossRef]
  18. Knop, O.; Reid, K.I.G.; Sutarno; Nakagawa, Y. Chalkogenides of the transition elements. VI. X-ray, neutron, and magnetic investigation of the spinels Co3O4, NiCo2O4, Co3S4, and NiCo2S4. Can. J. Chem. 1968, 46, 3463–3476. [Google Scholar] [CrossRef]
  19. Alcántara, R.; Jaraba, M.; Lavela, P.; Tirado, J.L. NiCo2O4 Spinel: First Report on a Transition Metal Oxide for the Negative Electrode of Sodium-Ion Batteries. Chem. Mater. 2002, 14, 2847–2848. [Google Scholar] [CrossRef]
  20. Zhou, W.; Kong, D.; Jia, X.; Ding, C.; Cheng, C.; Wen, G. NiCo2O4 nanosheet supported hierarchical core-shell arrays for high-performance supercapacitors. J. Mater. Chem. A 2014, 2, 6310–6315. [Google Scholar] [CrossRef]
  21. Hussain, M.; Ibupoto, Z.; Abbasi, M.; Liu, X.; Nur, O.; Willander, M. Synthesis of Three Dimensional Nickel Cobalt Oxide Nanoneedles on Nickel Foam, Their Characterization and Glucose Sensing Application. Sensors 2014, 14, 5415–5425. [Google Scholar] [CrossRef] [PubMed]
  22. Jadhav, H.S.; Kalubarme, R.S.; Park, C.-N.; Kim, J.; Park, C.-J. Facile and cost effective synthesis of mesoporous spinel NiCo2O4 as an anode for high lithium storage capacity. Nanoscale 2014, 6, 10071–10076. [Google Scholar] [CrossRef] [PubMed]
  23. Jia, H.; Yang, D.; Han, X.; Cai, J.; Liu, H.; He, W. Peroxidase-like activity of the Co3O4 nanoparticles used for biodetection and evaluation of antioxidant behavior. Nanoscale 2016, 8, 5938–5945. [Google Scholar] [CrossRef] [PubMed]
  24. Burch, R. Gold catalysts for pure hydrogen production in the water-gas shift reaction: Activity, structure and reaction mechanism. Phys. Chem. Chem. Phys. 2006, 8, 5483–5500. [Google Scholar] [CrossRef] [PubMed]
  25. Gong, J. Structure and Surface Chemistry of Gold-Based Model Catalysts. Chem. Rev. 2012, 112, 2987–3054. [Google Scholar] [CrossRef] [PubMed]
  26. Zhao, Y.; Jiang, L. Hollow Micro/Nanomaterials with Multilevel Interior Structures. Adv. Mater. 2009, 21, 3621–3638. [Google Scholar] [CrossRef]
  27. Hu, J.; Chen, M.; Fang, X.; Wu, L. Fabrication and application of inorganic hollow spheres. Chem. Soc. Rev. 2011, 40, 5472–5491. [Google Scholar] [CrossRef] [PubMed]
  28. Xu, C.F.; Cao, Y.; Chen, Y.; Huang, W.; Chen, D.L.; Huang, Q.Y.; Tu, J.C. Fast Synthesis of Hierarchical Co(OH)2 Nanosheet Hollow Spheres with Enhanced Glucose Sensing. Eur. J. Inorg. Chem. 2016, 2016, 3163–3168. [Google Scholar] [CrossRef]
  29. Nai, J.; Tian, Y.; Guan, X.; Guo, L. Pearson’s Principle Inspired Generalized Strategy for the Fabrication of Metal Hydroxide and Oxide Nanocages. J. Am. Chem. Soc. 2013, 135, 16082–16091. [Google Scholar] [CrossRef] [PubMed]
  30. Wang, Z.; Luan, D.; Boey, F.Y.C.; Lou, X.W. Fast Formation of SnO2 Nanoboxes with Enhanced Lithium Storage Capability. J. Am. Chem. Soc. 2011, 133, 4738–4741. [Google Scholar] [CrossRef] [PubMed]
  31. Ma, F.-X.; Yu, L.; Xu, C.-Y.; Lou, X.W. Self-supported formation of hierarchical NiCo2O4 tetragonal microtubes with enhanced electrochemical properties. Energy Environ. Sci. 2016, 9, 862–866. [Google Scholar] [CrossRef]
  32. Zhang, Y.; Ma, M.; Yang, J.; Su, H.; Huang, W.; Dong, X. Selective synthesis of hierarchical mesoporous spinel NiCo2O4 for high-performance supercapacitors. Nanoscale 2014, 6, 4303–4308. [Google Scholar] [CrossRef] [PubMed]
  33. Liu, L.; Wang, J.; Hou, Y.; Chen, J.; Liu, H.-K.; Wang, J.; Wu, Y. Self-Assembled 3D Foam-Like NiCo2O4 as Efficient Catalyst for Lithium Oxygen Batteries. Small 2016, 12, 602–611. [Google Scholar] [CrossRef] [PubMed]
  34. Liu, L.; Zhang, H.; Yang, J.; Mu, Y.; Wang, Y. Self-assembled novel dandelion-like NiCo2O4 microspheres@nanomeshes with superior electrochemical performance for supercapacitors and lithium-ion batteries. J. Mater. Chem. A 2015, 3, 22393–22403. [Google Scholar] [CrossRef]
  35. Yu, X.; Sun, Z.; Yan, Z.; Xiang, B.; Liu, X.; Du, P. Direct growth of porous crystalline NiCo2O4 nanowire arrays on a conductive electrode for high-performance electrocatalytic water oxidation. J. Mater. Chem. A 2014, 2, 20823–20831. [Google Scholar] [CrossRef]
  36. Jiang, H.; Chen, Z.; Cao, H.; Huang, Y. Peroxidase-like activity of chitosan stabilized silver nanoparticles for visual and colorimetric detection of glucose. Analyst 2012, 137, 5560–5564. [Google Scholar] [CrossRef] [PubMed]
  37. Chen, W.; Chen, J.; Feng, Y.-B.; Hong, L.; Chen, Q.-Y.; Wu, L.-F.; Lin, X.-H.; Xia, X.-H. Peroxidase-like activity of water-soluble cupric oxide nanoparticles and its analytical application for detection of hydrogen peroxide and glucose. Analyst 2012, 137, 1706–1712. [Google Scholar] [CrossRef] [PubMed]
  38. Xu, X.; Yang, X. Facile colorimetric detection of glucose based on an organic Fenton reaction. Anal. Methods 2011, 3, 1056–1059. [Google Scholar] [CrossRef]
  39. Tian, J.; Liu, S.; Luo, Y.; Sun, X. Fe(iii)-based coordination polymer nanoparticles: Peroxidase-like catalytic activity and their application to hydrogen peroxide and glucose detection. Catal. Sci. Technol. 2012, 2, 432–436. [Google Scholar] [CrossRef]
  40. Liu, Q.; Zhu, R.; Du, H.; Li, H.; Yang, Y.; Jia, Q.; Bian, B. Higher catalytic activity of porphyrin functionalized Co3O4 nanostructures for visual and colorimetric detection of H2O2 and glucose. Mater. Sci. Eng. C 2014, 43, 321–329. [Google Scholar] [CrossRef] [PubMed]
  41. Liang, H.; Jiang, S.; Yuan, Q.; Li, G.; Wang, F.; Zhang, Z.; Liu, J. Co-immobilization of multiple enzymes by metal coordinated nucleotide hydrogel nanofibers: Improved stability and an enzyme cascade for glucose detection. Nanoscale 2016, 8, 6071–6078. [Google Scholar] [CrossRef] [PubMed]
  42. Liu, B.; Sun, Z.; Huang, P.-J.J.; Liu, J. Hydrogen Peroxide Displacing DNA from Nanoceria: Mechanism and Detection of Glucose in Serum. J. Am. Chem. Soc. 2015, 137, 1290–1295. [Google Scholar] [CrossRef] [PubMed]
  43. Chen, X.; Zhou, X.; Hu, J. Pt-DNA complexes as peroxidase mimetics and their applications in colorimetric detection of H2O2 and glucose. Anal. Methods 2012, 4, 2183–2187. [Google Scholar] [CrossRef]
Figure 1. (a,b) SEM and TEM images of Cu2O solid sphere; (c,d) SEM images of the hierarchical NiCo2O4 hollow sphere.
Figure 1. (a,b) SEM and TEM images of Cu2O solid sphere; (c,d) SEM images of the hierarchical NiCo2O4 hollow sphere.
Sensors 17 00217 g001
Figure 2. TEM (ac) and HRTEM (d) images of NiCo2O4 hollow sphere. Inset in (b) is the corresponding selected area electron diffraction (SAED) pattern.
Figure 2. TEM (ac) and HRTEM (d) images of NiCo2O4 hollow sphere. Inset in (b) is the corresponding selected area electron diffraction (SAED) pattern.
Sensors 17 00217 g002
Figure 3. (a) X-ray diffraction (XRD) pattern of as-prepared NiCo2O4 hollow sphere sample; (b) N2 adsorption–desorption isotherms, and inset is the corresponding pore size distribution of the as-prepared hierarchical NiCo2O4 hollow sphere.
Figure 3. (a) X-ray diffraction (XRD) pattern of as-prepared NiCo2O4 hollow sphere sample; (b) N2 adsorption–desorption isotherms, and inset is the corresponding pore size distribution of the as-prepared hierarchical NiCo2O4 hollow sphere.
Sensors 17 00217 g003
Figure 4. X-ray photoelectron spectroscopy (XPS) spectrum of the NiCo2O4 hollow sphere: (a) survey; (b) Ni 2p; (c) Co 2p; (d) O 1s.
Figure 4. X-ray photoelectron spectroscopy (XPS) spectrum of the NiCo2O4 hollow sphere: (a) survey; (b) Ni 2p; (c) Co 2p; (d) O 1s.
Sensors 17 00217 g004
Figure 5. Representative TEM images of the samples at different stages: (a) Cu2O; (b) Cu2O@Ni–Co hydroxide; (c) Ni–Co hydroxide hollow sphere precursor; and (d) NiCo2O4 hollow sphere. (e) The corresponding schematic illustration of the formation process for hierarchical NiCo2O4 hollow sphere. Abbreviations: TT, thermal treatment.
Figure 5. Representative TEM images of the samples at different stages: (a) Cu2O; (b) Cu2O@Ni–Co hydroxide; (c) Ni–Co hydroxide hollow sphere precursor; and (d) NiCo2O4 hollow sphere. (e) The corresponding schematic illustration of the formation process for hierarchical NiCo2O4 hollow sphere. Abbreviations: TT, thermal treatment.
Sensors 17 00217 g005
Figure 6. (a) Photograph and absorption spectra of colorimetric reactions under different conditions: (i) 3,3,5,5-tetramethylbenzidine (TMB) + H2O2; (ii) TMB + NiCo2O4; (iii) TMB + H2O2 + NiCo2O4; (iv) TMB + H2O2 + NiO; (v) TMB + H2O2 + Co3O4. TMB concentration- (b) and pH- (c) dependent peroxidase-like activity of hierarchical NiCo2O4 hollow sphere. Experimental conditions: 5 μL of 1 mg·mL−1 enzyme mimetic dispersions were incubated with 3 mL of pre-prepared sodium citrate buffer solution (0.1 M, pH 4.5) with the presence of H2O2 (0.02 M) and TMB (0.08 mM).
Figure 6. (a) Photograph and absorption spectra of colorimetric reactions under different conditions: (i) 3,3,5,5-tetramethylbenzidine (TMB) + H2O2; (ii) TMB + NiCo2O4; (iii) TMB + H2O2 + NiCo2O4; (iv) TMB + H2O2 + NiO; (v) TMB + H2O2 + Co3O4. TMB concentration- (b) and pH- (c) dependent peroxidase-like activity of hierarchical NiCo2O4 hollow sphere. Experimental conditions: 5 μL of 1 mg·mL−1 enzyme mimetic dispersions were incubated with 3 mL of pre-prepared sodium citrate buffer solution (0.1 M, pH 4.5) with the presence of H2O2 (0.02 M) and TMB (0.08 mM).
Sensors 17 00217 g006
Figure 7. (a) Absorption spectra of the hierarchical NiCo2O4 hollow sphere with various concentrations of H2O2 (0.01–0.4 mM). (b) The corresponding linear calibration curve. The inset shows the photograph of color change for various concentrations.
Figure 7. (a) Absorption spectra of the hierarchical NiCo2O4 hollow sphere with various concentrations of H2O2 (0.01–0.4 mM). (b) The corresponding linear calibration curve. The inset shows the photograph of color change for various concentrations.
Sensors 17 00217 g007
Figure 8. Scheme illustration for colorimetric detection of glucose using the hierarchical NiCo2O4 hollow sphere.
Figure 8. Scheme illustration for colorimetric detection of glucose using the hierarchical NiCo2O4 hollow sphere.
Sensors 17 00217 g008
Figure 9. (a) Absorption spectra of the hierarchical NiCo2O4 hollow sphere with various concentrations of glucose (0.1–4.5 mM). (b) The corresponding linear calibration curve. The inset shows the photograph of color change for various concentrations.
Figure 9. (a) Absorption spectra of the hierarchical NiCo2O4 hollow sphere with various concentrations of glucose (0.1–4.5 mM). (b) The corresponding linear calibration curve. The inset shows the photograph of color change for various concentrations.
Sensors 17 00217 g009
Figure 10. Selectivity of the proposed sensor for glucose detection was assessed by measuring the absorption intensity at 652 nm. The concentrations for fructose, galactose, sucrose, and NaCl are 20 mM, respectively.
Figure 10. Selectivity of the proposed sensor for glucose detection was assessed by measuring the absorption intensity at 652 nm. The concentrations for fructose, galactose, sucrose, and NaCl are 20 mM, respectively.
Sensors 17 00217 g010
Table 1. Comparison of the linear ranges and the detection limits with other methods for the detection of glucose.
Table 1. Comparison of the linear ranges and the detection limits with other methods for the detection of glucose.
CatalystLinear Range (μM)Detection Limit (μM)Reference
NiCo2O4100–45005.31This work
CuO100–8000-[37]
V2O510–200010[3]
Au nanoparticles30–100030[38]
FeCPNPs2–201[39]
H2TCPP–Co3O4 nanocomposites1–100.86[40]
Zn2+/AMP nanofiber-0.6[41]
CeO2 nanoparticle-8.9[42]
Pt–DNA complexes0.1–10000.1[43]
FeCPNPs: Fe (III)-based coordination polymer nanoparticles. H2TCPP: 5,10,15,20-Tetrakis(4-carboxyl pheyl)-porphyrin. AMP: Adenosine 5′-monophosphate.

Share and Cite

MDPI and ACS Style

Huang, W.; Lin, T.; Cao, Y.; Lai, X.; Peng, J.; Tu, J. Hierarchical NiCo2O4 Hollow Sphere as a Peroxidase Mimetic for Colorimetric Detection of H2O2 and Glucose. Sensors 2017, 17, 217. https://doi.org/10.3390/s17010217

AMA Style

Huang W, Lin T, Cao Y, Lai X, Peng J, Tu J. Hierarchical NiCo2O4 Hollow Sphere as a Peroxidase Mimetic for Colorimetric Detection of H2O2 and Glucose. Sensors. 2017; 17(1):217. https://doi.org/10.3390/s17010217

Chicago/Turabian Style

Huang, Wei, Tianye Lin, Yang Cao, Xiaoyong Lai, Juan Peng, and Jinchun Tu. 2017. "Hierarchical NiCo2O4 Hollow Sphere as a Peroxidase Mimetic for Colorimetric Detection of H2O2 and Glucose" Sensors 17, no. 1: 217. https://doi.org/10.3390/s17010217

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop