Next Article in Journal
Research on the Mass Adding and Removing Combined Mechanical Trimming Method of the Ring MEMS Gyroscope
Previous Article in Journal
Investigating the Influence of Probe Pressure on Human Skin Using Diffusive Reflection Spectroscopy
Previous Article in Special Issue
Low-Temperature Adaptive Dual-Network MXene Nanocomposite Hydrogel as Flexible Wearable Strain Sensors
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Research on Packaging Reliability and Quality Factor Degradation Model for Wafer-Level Vacuum Sealing MEMS Gyroscopes

1
School of Computer, Guangdong University of Technology, Guangzhou 510006, China
2
Science and Technology on Reliability Physics and Application Technology of Electronic Component Laboratory, China Electronic Product Reliability and Environmental Testing Research Institute, Guangzhou 510006, China
3
National Key Laboratory of Science and Technology on Micro/Nano Fabrication, Institute of Microelectronics, Peking University, Beijing 100871, China
*
Authors to whom correspondence should be addressed.
Micromachines 2023, 14(10), 1956; https://doi.org/10.3390/mi14101956
Submission received: 11 September 2023 / Revised: 14 October 2023 / Accepted: 17 October 2023 / Published: 20 October 2023
(This article belongs to the Special Issue Flexible and Wearable Sensors, and Systems)

Abstract

:
MEMS gyroscopes are widely applied in consumer electronics, aerospace, missile guidance, and other fields. Reliable packaging is the foundation for ensuring the survivability and performance of the sensor in harsh environments, but gas leakage models of wafer-level MEMS gyroscopes are rarely reported. This paper proposes a gas leakage model for evaluating the packaging reliability of wafer-level MEMS gyroscopes. Based on thermodynamics and hydromechanics, the relationships between the quality factor, gas molecule number, and a quality factor degradation model are derived. The mechanism of the effect of gas leakage on the quality factor is explored at wafer-level packaging. The experimental results show that the reciprocal of the quality factor is exponentially related to gas leakage time, which is in accordance with the theoretical analysis. The coefficients of determination (R2) are all greater than 0.95 by fitting the curves in Matlab R2022b. The stable values of the quality factor for drive mode and sense mode are predicted to be 6609.4 and 1205.1, respectively, and the average degradation characteristic time is 435.84 h. The gas leakage time is at least eight times the average characteristic time, namely 3486.72 h, before a stable condition is achieved in the packaging chamber of the MEMS gyroscopes.

1. Introduction

The microelectromechanical system (MEMS) represents a sophisticated microintelligent system that leverages microelectronics, micromechanics, and related technologies to integrate sensors, actuators, and signal transmission components [1]. MEMS sensors exhibit key attributes such as compact size, lightweight design, and cost-effectiveness, and they are on the brink of achieving passive operation, miniaturization, and immunity to interference [2]. With the relentless progression of technology, MEMS sensors have found widespread utility across various domains, including consumer electronics, aerospace, military equipment, biomedicine, and more [3]. Notably, MEMS sensors usually rely on movable resonant structures, such as gyroscopes and accelerometers.
To optimize the performance of these devices, it is important to reduce the air damping of their moving structures. High-vacuum packaging serves to achieve this point, thereby obtaining a high Q-value, particularly in the case of gyroscopes [4]. Nowadays, the Q-value of high-performance gyroscopes can exceed 100,000 or even 1,000,000, underscoring the increasing importance of packaging reliability [5]. However, it is imperative to acknowledge that the vacuum within the MEMS chamber is subject to gradual degradation over time, exerting a direct impact on the performance of vacuum-packaged MEMS sensors and posing a significant threat to their long-term reliability [6]. Consequently, the issues of vacuum degradation and subsequent failure represent recurrent challenges encountered in the context of vacuum-packaged MEMS sensors [7].
Wafer-level packaging encapsulates MEMS structures on silicon chips between bonded wafers through surface micromachining and electrical interconnections [8,9]. It has the advantages of low cost, mass production, and high reliability. In 2019, Faisal Iqbal et al. fabricated a multiaxis gyroscope at 100 mTorr using wafer-level packaging, which has a high sensitivity of 12.56 μV/dps, 17.13 μV/dps, and 25.79 μV/dps in the roll, pitch, and yaw modes, respectively [10]. In 2021, Mustafa Mert Torunbalci et al. proposed a simple all-silicon wafer-level packaging method that achieves good hermeticity after temperature cycling (25–85 °C) and harsh temperature shocks (5 min @ 300 °C) [11]. A MEMS disk resonant gyroscope based on wafer-level packaging was reported by Hao Wang et al., achieving an angular random walk (ARW) of 0.05 ° / h and a bias instability of 0.42°/h within a full scale of ±300°/s [12].
While previous studies have established the relationship between the quality factor and temperature [13,14,15,16], research on the relationship between the quality factor and air pressure has rarely been reported. It is noteworthy that the impact of temperature on sensors can be mitigated through circuit compensation [17,18], but the effect of variations in gas pressure is generally difficult to compensate by circuitry, which leads to significant degradation of gyroscope performance [19,20]. Therefore, this paper focuses on elucidating the effects of pressure changes on the Q-value of MEMS gyroscopes.
Apart from temperature, gas leakage will cause pressure fluctuations in MEMS gyroscopes [21,22]. The internal pressure and leakage rate of the wafer-level packaged gyroscopes can be monitored by FIB and capacitance [23,24]. In 2019, Hengmao Liang et al. proposed a low-cost, 3D wafer-level packaging technology based on a coplanar Au-Si bonding structure [25]. The leak rate of the packaged chips (the cavity volume is ~0.0015 cc) is 5 × 10−8 atm·cc s−1 according to the MIL-STD-883F standard [26]. A wafer-level vacuum encapsulation method for sealing cavities by Au-Al thermocompression bonding at 250 °C has been proposed with a leak rate smaller than 2.8 × 10−14 mbarL/s [27]. In 2021, a novel solid–liquid interdiffusion (SLID) bonding process was reported, which yielded a leak value lower than 0.1 × 10−9 atm·cm3/s [28]. Nevertheless, there is a lack of theoretical studies on the model of gas leakage within wafer-level packaged gyroscopes. As a result, analyzing the pressure variation caused by gas leakage at wafer-level packaging is the focus of this work.
To eliminate the effect of temperature on pressure, it is essential to develop a degradation model at room temperature [29]. In our previous work, we developed a quality factor degradation model for device-level packaged gyros based on internal material outgassing, ignoring the effect of air leakage [30]. Considering that wafer-level packaging is an inevitable trend for high-performance gyroscopes, we performed long-term degradation tests for the two-mode quality factors of vacuum-sealed gyroscopes stored at room temperature, aiming to investigate packaging reliability and the degradation model for quality factors in wafer-level packaged gyroscopes.

2. Theoretical Analyses

The wafer-level vacuum-packaged gyroscope is shown in Figure 1. The movable structure of the gyroscope is enclosed within a vacuum chamber, utilizing a “sandwich” structure by anodic bonding between the glass substrate and the glass cover. The glass base below contains the electrodes and isolation layers. However, gas leakage within the encapsulation leads to an increase in the number of free gas molecules, resulting in variations in internal pressure and quality factors in the cavity.
Figure 2 illustrates a simplified gas leakage process in the vacuum chamber. As the length and width of the vacuum-encapsulated cavity are significantly larger than the height, the gas diffusion region is seen as a two-dimensional plane. Assuming that initially there is a vacuum in the cavity, the outside gas diffuses from the boundary to the center of the cavity. The gas molecules are uniformly distributed along the x-z cross-section and the y-z cross-section, with diffusion along the x and y axes. Eventually, the gas within the cavity will reach dynamic equilibrium with the external gas at room temperature. Therefore, based on the principles of thermodynamics and fluid mechanics, the relationships between the quality factors of dive mode and sense mode (Qd and Qs), pressure (p), gas molecule number (N), and their degradation models can be derived in detail.

2.1. The Effect Mechanism of Gas Leakage

The relationship between the quality factor, air pressure, and gas number can be deduced as follows:
According to the principle of thermodynamics, the gas viscosity coefficient μ0 can be obtained as [31]:
μ 0 = 1 3 ρ v ¯ λ ¯ = N v ¯ τ ¯ 3 V 8 k b T m 0 π
where v ¯ is mean velocity, λ ¯ is mean free path, and ρ is gas density, which equations can be expressed from Maxwell’s velocity distribution law; kb, m0, and τ ¯ are the Boltzmann constant, the mass of a molecule, and the mean free time, respectively; T is the temperature; V is the volume of the sealed cavity; and N is the number of gas molecules.
The quality factor is strongly related to the air damping of the gyroscope, which mainly includes slide-film damping and squeeze-film damping. Slide-film damping is caused by the parallel motion of two flat plates while maintaining a constant gap. Squeeze-film damping is caused by the relative vertical movement of the two flat plates. Based on thermodynamic theory, the damping coefficient of slip-film combs c s l i d e and squeeze-film combs c s q u e e z e can be expressed as [32]:
c s l i d e = μ 0 S d c s q u e e z e = σ μ 0 w 3 l d 3
where S is the overlapped area of the plate capacitor, d is the gap between the combs, w and l are the width and length of the plate capacitor, respectively, and σ is a parameter determined by w / l . If w / l = 1 , then σ = 0.427 . If w / l 0 , then σ = 1 . Then, we can obtain [33]:
c s q u e e z e c s l i d e = σ w 3 l d 2 S = σ w 2 d 2
Based on the definition of the quality factor, the quality factors of the two modes can be derived as [33]:
Q s = m s ω s c s q u e e z e = d 3 m s ω s σ μ 0 w 3 l , Q d = m d ω d c s l i d e = d m d ω d μ 0 S
where ms, cs, ω s , and Qs represent the mass, damping coefficient, resonant frequency, and quality factor of the sense mode, respectively. md, cd, ω d , and Qd represent the mass, damping coefficient, resonant frequency, and quality factor of the drive mode, respectively.
According to the ideal gas state equation, there is [31]:
p V = N k b T
where p is the internal pressure. Thus, utilizing the previous equation, we can deduce [30]:
Q s = 3 π d 3 m s ω s 8 σ w 3 l τ ¯ p , Q d = 3 π d m d ω d 8 S τ ¯ p
The relationships between the quality factor, air pressure, and gas number can be simplified to
p ( t ) N ( t ) Q 1 ( t )
It can be seen that the internal pressure is directly proportional to the number of gas molecules and inversely proportional to the quality factor. Therefore, gas leakage due to the failure of the wafer package will increase the internal air pressure, resulting in a decrease in the quality factor.

2.2. Degradation Models Based on Gas Leakage

Simplify the enclosed cavity into a rectangle with length and width of 2lx and 2ly, respectively. By assuming that the cavity is initially under vacuum, it is inferred that external gas molecules will gradually diffuse from the boundary toward the center. Taking the center of the cavity as the origin, establish a rectangular coordinate system, as shown in the figure. Due to the symmetry of gas diffusion, only the first quadrant is analyzed here. The maximum diffusion lengths along the x and y directions are lx and ly, respectively. The gas diffusion equation and boundary conditions are as follows:
u t = D 2 u x 2 + 2 u y 2 , ( 0 < x l x , 0 < y l y ) u x x = 0 = u y y = 0 = 0 , u x x = l x = u y y = l y = b k ( u u 0 ) u x , y , 0 = 0
where u ( x , y , t ) is the instantaneous gas density, x and y are the distances from the center of the cavity, respectively, t is the gas diffusion time, u0 represents the external gas density, which affects the rate of gas leakage, D is the gas diffusion coefficient, and b and k represent the heat transfer coefficient and thermal conductivity, respectively.
If θ = u u 0 , the equation for the definite solution is:
θ t = D 2 θ x 2 + 2 θ y 2 , ( 0 < x l x , 0 < y l y ) θ x x = 0 = θ y y = 0 = 0 , θ x x = l x = θ y y = l y = b k θ θ x , y , 0 = u 0 = θ 0
First, we assume that θ ( x , y , t ) = X ( x ) Y ( y ) T ( t ) by using the method of separation of variables, and we can obtain:
X ( x ) Y ( y ) d T d t = D ( Y ( y ) T ( t ) 2 X x 2 + X ( x ) T ( t ) 2 Y y 2 )
Equation (10) can be expressed as:
1 D T ( t ) d T d t = 1 X ( x ) 2 X x 2 + 1 Y ( y ) 2 Y y 2 = λ
If both sides of Equation (11) are equal to the constant −λ, we can obtain:
T ( t ) + λ D T ( t ) = 0
1 X ( x ) 2 X x 2 = λ + 1 Y ( y ) 2 Y y 2 = μ
Similarly, if both sides of Equation (13) are equal to a constant μ , the equation for X(x) can be isolated as follows:
X ( x ) + μ X ( x ) = 0 X ( 0 ) = 0 , X ( l x ) = b k X
First, we discuss the solution to Equation (14).
① If μ < 0 , assuming that μ = β 2 and β > 0 , then the general solution of Equation (14) is:
X ( x ) = C 1 e β x + C 2 e β x
From boundary condition X ( 0 ) = 0 , we can obtain X ( 0 ) = ( C 1 C 2 ) β = 0 . Since β > 0 , C 1 = C 2 . From boundary condition X ( l x ) = b k X , we can yield:
C 1 β ( e β l x e β l x ) = b k ( e β l x + e β l x ) C 1
If C 1 0 , then Equation (16) can be shown as:
k b l x β l x = e β l x + e β l x e β l x e β l x = c o t h ( β l x )
Now, assuming that Z 1 = k b l x β l x and Z 2 = c o t h ( β l x ) , we found that Z 1 and Z 2 have no intersection from Figure 3. Equation (17) has solutions only if C 1 = 0 . We can obtain C 1 = C 2 = 0 and X ( x ) 0 , which is a trivial solution. Therefore, μ < 0 is not valid.
② If μ = 0 , then the solution of Equation (14) is
X ( x ) = C 1 x + C 2
Substituting X ( 0 ) = 0 into Equation (18), we can yield C 1 = 0 . Substituting X l x = b k X into Equation (18), we can obtain C 1 = b k ( C 1 l x + C 2 ) . Thus, C 2 = 0 , X ( x ) 0 , and μ = 0 are not valid.
③ If μ > 0 , assuming that μ = β 2   a n d   β > 0 , then the general solution of Equation (14) is
X ( x ) = C 1 sin β x + C 2 cos β x
We can obtain C 1 = 0 by substituting X ( 0 ) = 0 into Equation (19). Equation (14) is derived as
X ( x ) = C 2 cos β x
Equation (13) can be deduced as
1 Y ( y ) 2 Y y 2 = λ + μ
If λ = μ + η , then the equation for Y(y) is obtained as
Y ( y ) + η Y ( y ) = 0 Y ( 0 ) = 0 , Y ( l y ) = b k Y
Similarly, Equation (22) has a nontrivial solution only if η > 0 . Supposing η = γ 2 , the general solution of Equation (15) is Y ( y ) = D 1 s i n ( γ y ) + D 2 c o s ( γ y ) . We can yield D 1 = 0 by substituting the boundary condition into the above formula. Consequently, the solution to Equation (22) is:
Y ( y ) = D 2 cos γ y
For the differential Equation (12), the categorical variables are used. Integrating both sides and taking the logarithm, it is obtained as:
T ( t ) = A exp ( λ D t )
where A is the integration constant, and θ ( x , y , t ) can be written as
θ = A exp ( λ D t ) C 2 cos ( β x ) D 2 cos ( γ y )
Substituting Equations (20) and (23) into the boundary conditions X l x = b k X and Y l y = b k Y , respectively, we can yield:
cot ( β l x ) = β k b
cot ( γ l y ) = γ k b
The transcendental Equation (26) can be solved by the graphical method. Supposing that Z 3 = c o t ( β l x ) and Z 4 = k b l x β l x , the curves for Z 3 and Z 4 are shown in Figure 4, respectively. The intersections of the curves are the solutions of Equation (26).
According to the above graph, there are infinite values of β (noted as β 1 , β 2 β m ). Each β corresponds to one form of Equation (25). Similarly, we found numerous γ (noted as γ 1 , γ 2 γ n ) based on the graphical method and corresponding Equation (23). By the superposition principle of solution, Equation (25) can be written as
θ ( x , y , t ) = m = 1 n = 1 exp ( λ D t ) E 1 m cos ( β m x ) G 1 n cos ( γ n y )
where E1m and G1n are integration constants, and A is combined with E1m. To solve for E1m and G1n, substituting Equation (28) into the boundary condition θ ( x , y , 0 ) = u 0 = θ 0 , we can yield:
θ 0 = m = 1 n = 1 E 1 m G 1 n cos ( β m x ) cos ( γ n y )
Equation (30) multiplied by c o s ( β p x ) d x ,   c o s ( γ q y ) d y and integrated from −lx to lx for x and from −ly to ly for y, respectively. It can be deduced as:
θ 0 l x l x l y l y cos β p x cos γ q y d x d y = l x l x l y l y m = 1 n = 1 E 1 m G 1 n cos β m x cos γ n y cos β p x cos γ q y d x d y
Since the above integrals are orthogonal, Equation (30) can be written as:
θ 0 l x l x cos β p x d x l y l y cos γ q y d y = E 1 m G 1 n l x l x cos 2 β m x d x l y l y cos 2 γ n y d y
Therefore, the solution of E1mG1n is deduced as:
E 1 m G 1 n = θ 0 4 sin β m l x sin γ n l y β m l x + sin β m l x cos β m l x γ n l y + sin γ n l y cos γ n l y
Substitute Equation (32) into Equation (28). From Equation (9), we know that θ 0 = u 0 . Equation (28) can then be written as:
θ = m = 1 n = 1 u 0 4 sin β m l x sin γ n l y cos β m x cos γ n y exp ( λ m n D t ) β m l x + sin β m l x cos β m l x γ n l y + sin γ n l y cos γ n l y
The higher-order terms are ignored in the above equations, only the first-order component is considered (m = 1, n = 1), and θ = u u 0 . The gas density can be deduced as:
u = u 0 u 0 4 sin β l x sin γ l y cos β x cos γ y exp ( λ D t ) β l x + sin β l x cos β l x γ n l y + sin γ l y cos γ l y
Integrating θ ( x , y , t ) over −lx to lx and −ly to ly, the number of gas molecules N(t) in the cavity can be calculated as:
N ( t ) = 4 l x l y u 0 16 u 0 sin 2 β l x sin 2 γ l y exp ( λ D t ) β γ β l x + sin β l x cos β l x γ l y + sin γ l y cos γ l y
Consequently, the degradation model can be obtained as
Q 1 ( t ) N ( t ) = a b exp ( c t )
where a, b, and c are constants, which can be yielded by comparing Equations (35) and (36).
a = 4 l x l y u 0
b = 16 u 0 sin 2 β l x sin 2 γ l y β γ β l x + sin β l x cos β l x γ l y + sin γ l y cos γ l y
c = λ D
The coefficients a, b, and c depend on factors such as the dimensions of the vacuum chamber, external temperature, pressure, etc. The physical meanings of the model parameters a, b, and c are as follows:
Parameter a denotes the quantity of gas molecules in the sample cavity, determined by the cavity size and external gas density. It also governs the final quality factor’s magnitude. Parameter b indicates that chamber size and pressure affect the degradation level. Parameter c characterizes the quality factor’s degradation rate, which is dependent on the gas diffusion coefficient and temperature.
Since equation Q ( t ) 1 N ( t ) = a b e x p ( c t ) serves as a simplified model, Equations (37)–(39) can only calculate the parameters a, b, and c in equation N t = a b e x p ( c t ) , which are used to predict the number of gas molecules N(t). The parameters a, b, and c fitted from the experimental data are specific to equation Q ( t ) 1 = a b e x p ( c t ) , which is used to predict the quality factor Q(t). In summary, while the parameters in equation N t = a b e x p ( c t ) can be computed using Equations (37)–(39), the parameters in equation Q ( t ) 1 = a b e x p ( c t ) cannot be directly obtained by Equations (37)–(39).
When t = 0 , N ( t ) 0 , which means that the number of gas molecules in the initial state of the chamber is approximately 0, namely, the vacuum state. The correctness of the theoretical derivation is confirmed by fitting the experimental data in Matlab to obtain ab. When t tends to infinity, l i m t N t = 4 l x l y u 0 , which means that the number of gas molecules tends to a constant value 4 l x l y u 0 , reaching the equilibrium state. The number of gas molecules in the cavity is predicted by experimentally measuring the external gas density u 0 . At the same time, the Q-value of both drive and sense modes reach stable values. We, therefore, define a constant k q to describe the magnitude of the change of the Q-value. The quality factor can be considered to reach a stable value when k q = | Q | Q < 1 % .

3. Experimental Results

To research the degradation of gyroscopes due to gas leakage in a practical situation, a long-term degradation test of the two-mode quality factor was performed over 8 months. During this period, the gyroscope was stored in a temperature-controlled chamber at room temperature (25 °C). The two-mode quality factors corresponding to different times were obtained through several tests. The results indicate a decrease in the quality factors from several hundred thousand to several thousand. The internal encapsulation leaks slowly at room temperature, and the air leakage causes a rise in air pressure and a decrease in quality factors. It takes about 4 months to enter a plateau of natural degradation, but it is not the end state. The relationship between 1/Qd and air leakage time t is approximately exponential, as is the relationship between 1/Qs and gas leakage time t, according to the data fitting analysis using Matlab. It is consistent with the analytical model of Equation (36), thus validating the correctness of the theoretical analysis.
During a natural degradation time of about 1.5 months, it can be concluded that parameters a, b, and c of the drive mode are 1.369 ∗ 10−4, 1.052 ∗ 10−4, and 3.35 ∗ 10−3, respectively. The fitted curve is 1 / Q d = 1.369 10 4 1.052 10 4 exp ( 3.35 10 3 t ) . The coefficient of determination (R2) is 0.98. For the sense mode, parameters a, b, and c are 7.477 ∗ 10−4, 1.802 ∗ 10−4, and 3.269 ∗ 10−3, respectively. The fitted equation is 1 / Q s = 7.477 10 4 1.802 10 4 exp ( 3.269 10 3 t ) . The coefficient of determination (R2) is 0.96. The test results and fitting curves are shown in Figure 5.
Over a period of approximately 8 months of natural degradation, the parameters a, b, and c of the drive mode are 1.513 ∗ 10−4, 1.115 ∗ 10−4, and 2.159 ∗ 10−3, respectively. The fitted equation is 1 / Q d = 1.513 10 4 1.115 10 4 exp ( 2.159 10 3 t ) . The coefficient of determination (R2) is 0.95. For the sense mode, parameters a, b, and c are 8.298 ∗ 10−4, 7.393 ∗ 10−4, and 2.448 ∗ 10−3, respectively. The fitted equation is 1 / Q s = 8.298 10 4 7.393 10 4 exp ( 2.448 10 3 t ) . The coefficient of determination (R2) is 0.97. The test results and fitting curves are shown in Figure 6. Thus, for Qd and Qs, the final values of 1 / a at room temperature are 6609.4 and 1205.1, respectively.
In addition, the fitted values of 1.369 ∗ 10−4 and 1.513 ∗ 10−4 for the drive mode do not differ greatly between two different time periods, and this is also the case for the sense mode. However, due to the differences in parameters such as mass and resonant frequency between the drive mode and the sense mode, the quality factors of the two modes are not the same. Consequently, this leads to variations in the fitting values of the two modes. It is important to note that Q ( t ) 1 is proportional to N ( t ) rather than Q ( t ) 1 being equal to N ( t ) . According to the definition of characteristic time (i.e., the time corresponding to the completion of e 1 of the air leakage process), it can be calculated that the characteristic times 1 / c of drive mode and sense mode are 463.18 h and 408.5 h, respectively, and the average degradation characteristic time is 435.84 h.
The fitted curves in Figure 6 indicate that the curves change from a sharp rise to a slow rise at approximately 2000 h. After 2000 h, although the Q-value remains in a slow decline for a long period of time, k q is extremely small, and the Q-value is approximately stable. Based on the experimental data, the k q values for both the drive and detection modes are 0.007 at t = 3096 h, indicating that the Q-value changes are extremely small and stable. Hence, to reach a steady state with air leakage inside the gyro package, the gas leakage time is at least eight times the average characteristic time, namely 3486.72 h. Since the natural aging time is too long for reliability design, temperature cycling tests for MEMS gyroscopes can be adopted to accelerate the encapsulation leakage process, thus improving the efficiency of package reliability research. Continuing this line of investigation will be a key focus of our future research.

4. Conclusions

This paper presents a novel method for assessing the reliability of wafer-level, packaged MEMS gyroscopes. Based on the principles of thermodynamics and hydrodynamics, a detailed derivation of the relationships between quality factor, air pressure, and gas number, as well as their degradation models, are presented. The results of degradation tests have demonstrated an exponential relationship between the reciprocal of the quality factor and the air leakage time at room temperature, which is consistent with the theoretical analysis, and the coefficients of determination (R2) are all greater than 0.95. Based on the experimental data, an equation describing the variation of quality factors Q(t) with leakage time t was obtained by Matlab. This equation makes it possible to predict the steady-state value of the quality factor under this condition, thereby assessing the reliability of the gyroscope sealing against gas leakage. The limit values of the quality factor for the two modes are predicted to be 6609.4 and 1205.1, respectively. The proposed model holds potential for implementation in reliability design and the establishment of standards for degradation tests.
By fitting the experimental data to a mathematical model, a quantitative relationship between the quality factor and time is established to extrapolate the long-term behavior of the gyroscope’s quality factor. This predictive capability provides valuable insight into the reliability of the gyroscope’s sealing mechanism, facilitating an evaluation of the stability and effectiveness of the encapsulation process in preventing gas leakage. However, it is important to note that gas leakage and natural degradation of the encapsulation at room temperature exhibit an extremely slow progression, taking more than 4 months to reach a degradation plateau. To expedite the design cycle for gas leakage package reliability, our future research will focus on temperature cycling tests of wafer-level gyroscopes to accelerate the gas leakage process. Additionally, these temperature cycling tests will foster the expansion of cracks at material interfaces, ultimately allowing leakage to reach a stable value. By reaching a steady state for gas leaks, the reliability of the gyroscope is expected to be notably enhanced.
In summary, this study presents a comprehensive approach to assessing the reliability of wafer-level packaged MEMS gyroscopes. The derived models and experimentally validated results provide a deeper understanding of the degradation behavior and sealing effectiveness of gas leakage. The proposed model has significant implications for reliability design and the establishment of degradation test standards in the field of MEMS gyroscopes.

Author Contributions

Methodology, Y.X. and C.H.; software, S.L.; validation, S.L.; formal analysis, H.W.; investigation, Y.X.; data curation, H.W.; writing—original draft, Y.X.; writing—review and editing, C.H.; supervision, Q.H. and G.Y.; project administration, L.C. and Q.H.; funding acquisition, C.H. All authors have read and agreed to the published version of the manuscript.

Funding

This work was partially supported by the National Natural Science Foundation of China (grant no. 62104047), the Natural Science Foundation of Guangdong Province (grant no. 2023A1515010291), and the Basic and Applied Basic Research Project of Guangzhou Basic Research Program (grant no. 2023A04J1707).

Data Availability Statement

Not applicable.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Xu, P.; Si, C.; He, Y.; Wei, Z.; Jia, L.; Han, G.; Ning, J.; Yang, F. A Novel High-Q Dual-Mass MEMS Tuning Fork Gyroscope Based on 3D Wafer-Level Packaging. Sensors 2021, 21, 19. [Google Scholar] [CrossRef] [PubMed]
  2. Du, G.; Dong, X.; Huang, X.; Su, W.; Zhang, P. Reliability Evaluation Based on Mathematical Degradation Model for Vacuum Packaged MEMS Sensor. Micromachines 2022, 13, 1713. [Google Scholar] [CrossRef] [PubMed]
  3. Esashi, M. Wafer level packaging of MEMS. J. Micromech. Microeng. 2008, 18, 073001. [Google Scholar] [CrossRef]
  4. Gerrard, D.D.; Ahn, C.H.; Flader, I.B.; Chen, Y.; Ng, E.J.; Yang, Y.; Kenny, T.W. Q-factor optimization in disk resonator gyroscopes via geometric parameterization. In Proceedings of the 2016 IEEE 29th International Conference on Micro Electro Mechanical Systems (MEMS), Shanghai, China, 24–28 January 2016; pp. 994–997. [Google Scholar]
  5. Jia, L.; Han, G.; Wei, Z.; Si, C.; Ning, J.; Yang, F.; Han, W. A Novel Packaged Ultra-High Q Silicon MEMS Butterfly Vibratory Gyroscope. Micromachines 2022, 13, 1967. [Google Scholar] [CrossRef]
  6. Mirjalili, R.; Wen, H.; Serrano, D.E.; Ayazi, F. Substrate-decoupled silicon disk resonators having degenerate gyroscopic modes with Q in excess of 1-million. In Proceedings of the 2015 Transducers—2015 18th International Conference on Solid-State Sensors, Actuators and Microsystems (TRANSDUCERS), Anchorage, AK, USA, 21–25 June 2015; pp. 15–18. [Google Scholar]
  7. Akashi, T.; Funabashi, H.; Takagi, H.; Omura, Y.; Hata, Y. Wafer-level hermetic vacuum packaging by bonding with a copper–tin thin film sealing ring. J. Micromech. Microeng. 2018, 28, 044002. [Google Scholar] [CrossRef]
  8. Ayazi, F.; Wen, H.; Jeong, Y.; Gupta, P.; Daruwalla, A.; Liu, C.-S. High-Q Timing and Inertial Measurement Unit Chip (TIMU) with 3D Wafer-Level Packaging. In Proceedings of the 2019 IEEE Custom Integrated Circuits Conference (CICC), Austin, TX, USA, 14–17 April 2019; pp. 1–8. [Google Scholar]
  9. Esashi, M. Packaging, Sealing, and Interconnection. In 3D and Circuit Integration of MEMS; John Wiley & Sons, Ltd.: Hoboken, NJ, USA, 2021; pp. 377–407. [Google Scholar]
  10. Iqbal, F.; Din, H.; Lee, B. Single Drive Multi-Axis Gyroscope with High Dynamic Range, High Linearity and Wide Bandwidth. Micromachines 2019, 10, 410. [Google Scholar] [CrossRef]
  11. Torunbalci, M.M.; Gavcar, H.D.; Yesil, F.; Alper, S.E.; Akin, T. An All-Silicon Process Platform for Wafer-Level Vacuum Packaged MEMS Devices. IEEE Sens. J. 2021, 21, 13958–13964. [Google Scholar] [CrossRef]
  12. Wang, H.; Quan, H.; Zhou, J.; Zhang, L.; Xie, J.; Chang, H. A Wafer-Level Vacuum Packaged MEMS Disk Resonator Gyroscope With 0.42°/h Bias Instability Within ±300°/s Full Scale. IEEE Trans. Ind. Electron. 2022, 69, 5304–5313. [Google Scholar] [CrossRef]
  13. Wang, Y.; Cao, R.; Li, C.; Dean, R.N. Concepts, Roadmaps and Challenges of Ovenized MEMS Gyroscopes: A Review. IEEE Sens. J. 2021, 21, 92–119. [Google Scholar] [CrossRef]
  14. Schiwietz, D.; Weig, E.M.; Degenfeld-Schonburg, P. Temperature Dependence of Quality Factors at High Frequencies in MEMS Gyroscopes. In Proceedings of the 2023 IEEE 36th International Conference on Micro Electro Mechanical Systems (MEMS), Munich, Germany, 15–19 January 2023; pp. 877–880. [Google Scholar]
  15. Cui, J.; Zhao, Q. Thermal Stabilization of Quality Factor for Dual-axis MEMS Gyroscope Based on Joule Effect In-situ Dynamic Tuning. IEEE Trans. Ind. Electron. 2023, 71, 1060–1068. [Google Scholar] [CrossRef]
  16. Schiwietz, D.; Weig, E.M.; Degenfeld-Schonburg, P. Thermoelastic damping in MEMS gyroscopes at high frequencies. Microsyst. Nanoeng. 2023, 9, 11. [Google Scholar] [CrossRef] [PubMed]
  17. Cui, J.; Yan, G.; Zhao, Q. Enhanced temperature stability of scale factor in MEMS gyroscope based on multi parameters fusion compensation method. Measurement 2019, 148, 106947. [Google Scholar] [CrossRef]
  18. Cui, J.; Zhao, Q. Bias thermal stability improvement of MEMS gyroscope with quadrature motion correction and temperature self-sensing compensation. Micro Nano Lett. 2020, 15, 234–238. [Google Scholar] [CrossRef]
  19. Pistorio, F.; Saleem, M.M.; Somà, A. A Dual-Mass Resonant MEMS Gyroscope Design with Electrostatic Tuning for Frequency Mismatch Compensation. Appl. Sci. 2021, 11, 1129. [Google Scholar] [CrossRef]
  20. Gill, W.A.; Howard, I.; Mazhar, I.; McKee, K. A Review of MEMS Vibrating Gyroscopes and Their Reliability Issues in Harsh Environments. Sensors 2022, 22, 7405. [Google Scholar] [CrossRef]
  21. Liang, H.; He, X.; Xiong, B. Two-Mask Wafer-Level Vacuum Packaging with Bulk-Si 3D Interconnects for MEMS Devices and Its Package Performances. IEEE Sens. J. 2022, 22, 14522–14530. [Google Scholar] [CrossRef]
  22. Kopf, M.; Mogor-Györffy, R.; Breitling, A. Hydrogen gas diffusion influences cavity pressure of encapsulated inertial sensors. Micro Nano Eng. 2022, 16, 100144. [Google Scholar] [CrossRef]
  23. A New Method to Determine the Internal Pressure and Leakage Rate of MEMS Packages|Semantic Scholar. Available online: https://www.semanticscholar.org/paper/A-new-method-to-determine-the-internal-pressure-and-Wang-Coster/caa2ac6493607a1e2eda6b53f09a724c00075269 (accessed on 8 April 2023).
  24. Wang, B.; De Coster, J.; Wevers, M.; De Wolf, I. Gas leak rate study of MEMS thin film packages in different environments. In Proceedings of the 5th Electronics System-Integration Technology Conference (ESTC), Helsinki, Finland, 16–18 September 2014; pp. 1–4. [Google Scholar]
  25. Liang, H.; Liu, S.; Xiong, B. 3D wafer level packaging technology based on the co-planar Au–Si bonding structure. J. Micromech. Microeng. 2019, 29, 035010. [Google Scholar] [CrossRef]
  26. MIL-STD-883F; Department of defense test method standard: Microcircuits. United States Department of Defense: Arlington County, VA, USA, 2010.
  27. Wang, X.; Bleiker, S.J.; Edinger, P.; Errando-Herranz, C.; Roxhed, N.; Stemme, G.; Gylfason, K.B.; Niklaus, F. Wafer-Level Vacuum Sealing by Transfer Bonding of Silicon Caps for Small Footprint and Ultra-Thin MEMS Packages. J. Microelectromechanical Syst. 2019, 28, 460–471. [Google Scholar] [CrossRef]
  28. Temel, O.; Kalay, Y.E.; Akin, T. Wafer-Level Low-Temperature Solid-Liquid Inter-Diffusion Bonding with Thin Au-Sn Layers for MEMS Encapsulation. J. Microelectromechanical Syst. 2021, 30, 64–71. [Google Scholar] [CrossRef]
  29. Aono, T.; Suzuki, K.; Kanamaru, M.; Okada, R.; Maeda, D.; Hayashi, M.; Isono, Y. Development of wafer-level-packaging technology for simultaneous sealing of accelerometer and gyroscope under different pressures. J. Micromech. Microeng. 2016, 26, 105007. [Google Scholar] [CrossRef]
  30. He, C.H.; Wang, Y.P.; Huang, Q.W.; Zhao, Q.C.; Yang, Z.C.; Zhang, D.C.; Yan, G.Z. Research on the packaging reliability and degradation models of quality factors for a high vacuum sealed MEMS gyroscope. In Proceedings of the 2017 19th International Conference on Solid-State Sensors, Actuators and Microsystems (TRANSDUCERS), Kaohsiung, Taiwan, 18–22 June 2017; pp. 1077–1080. [Google Scholar]
  31. Feynman, R.P.; Leighton, R.B.; Sands, M. The Feynman Lectures on Physics, Vol. I: The New Millennium Edition: Mainly Mechanics, Radiation, and Heat; Basic Books: New York, NY, USA, 2011; Volume 1. [Google Scholar]
  32. Clark, W.A. Micromachined Vibratory Rate Gyroscope. Ph.D. Thesis, University of California, Berkeley, CA, USA, 1997. [Google Scholar]
  33. Yazdi, N. Micro-G Silicon Accelerometers with High Performance CMOS Interface Circuitr. Ph.D. Thesis, University of Michigan, Ann Arbor, MI, USA, 1999. [Google Scholar]
Figure 1. (a) Schematic of a wafer-level vacuum-packaged gyroscope. (b) Physical diagram of wafer-level vacuum-packaged gyroscopes.
Figure 1. (a) Schematic of a wafer-level vacuum-packaged gyroscope. (b) Physical diagram of wafer-level vacuum-packaged gyroscopes.
Micromachines 14 01956 g001
Figure 2. The simplified process of gas leakage, model derivation of quality factors (Qd and Qs), and number of gas molecules (N).
Figure 2. The simplified process of gas leakage, model derivation of quality factors (Qd and Qs), and number of gas molecules (N).
Micromachines 14 01956 g002
Figure 3. Diagram of the solution to Equation (17).
Figure 3. Diagram of the solution to Equation (17).
Micromachines 14 01956 g003
Figure 4. Diagram of the solution to the transcendental Equation (26).
Figure 4. Diagram of the solution to the transcendental Equation (26).
Micromachines 14 01956 g004
Figure 5. During approximately 1.5 months, the reciprocal of the quality factor is exponentially related to the gas leakage time. (a) Drive mode. (b) Sense mode.
Figure 5. During approximately 1.5 months, the reciprocal of the quality factor is exponentially related to the gas leakage time. (a) Drive mode. (b) Sense mode.
Micromachines 14 01956 g005
Figure 6. During approximately 8 months, the reciprocal of the quality factor is exponentially related to the gas leakage time. (a) Drive mode. (b) Sense mode.
Figure 6. During approximately 8 months, the reciprocal of the quality factor is exponentially related to the gas leakage time. (a) Drive mode. (b) Sense mode.
Micromachines 14 01956 g006
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Xu, Y.; Liu, S.; He, C.; Wu, H.; Cheng, L.; Huang, Q.; Yan, G. Research on Packaging Reliability and Quality Factor Degradation Model for Wafer-Level Vacuum Sealing MEMS Gyroscopes. Micromachines 2023, 14, 1956. https://doi.org/10.3390/mi14101956

AMA Style

Xu Y, Liu S, He C, Wu H, Cheng L, Huang Q, Yan G. Research on Packaging Reliability and Quality Factor Degradation Model for Wafer-Level Vacuum Sealing MEMS Gyroscopes. Micromachines. 2023; 14(10):1956. https://doi.org/10.3390/mi14101956

Chicago/Turabian Style

Xu, Yingyu, Shuibin Liu, Chunhua He, Heng Wu, Lianglun Cheng, Qinwen Huang, and Guizhen Yan. 2023. "Research on Packaging Reliability and Quality Factor Degradation Model for Wafer-Level Vacuum Sealing MEMS Gyroscopes" Micromachines 14, no. 10: 1956. https://doi.org/10.3390/mi14101956

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop