Article

Experimental and Modeling Investigations on the Water Sorption Behaviors of Autoclaved Aerated Concrete

by
Halina Garbalińska
1,*,
Magdalena Bochenek
1 and
Marcin Stasiak
2
1
Faculty of Civil and Environmental Engineering, West Pomeranian University of Technology in Szczecin, Al. Piastów 50a, 70-311 Szczecin, Poland
2
Institute of Mathematics, Faculty of Automatic Control, Robotics and Electrical Engineering, Poznań University of Technology, Piotrowo 3A, 60-965 Poznań, Poland
*
Author to whom correspondence should be addressed.
Materials 2021, 14(21), 6235; https://doi.org/10.3390/ma14216235
Submission received: 9 August 2021 / Revised: 7 October 2021 / Accepted: 14 October 2021 / Published: 20 October 2021
(This article belongs to the Section Construction and Building Materials)

Abstract

:
The thermal and moisture properties of building envelope materials determine their performance over many years of use. Moisture has a particularly negative impact, impairing all the technical parameters and adversely affecting the microclimatic conditions inside the building. This article presents research and analysis on the moisture behavior of partitions made of autoclaved aerated concrete. Autoclaved aerated concrete is a very popular material for building external walls because of its relatively good thermal insulation and sufficient strength, if it is not subjected to increased moisture. This study investigated how the moisture content of this material changes with the change in relative air humidity. The four most popular density classes were studied. The sorption isotherms were determined by the static gravimetric method throughout the whole hygroscopic range. Moreover, the applicability of various models to describe sorption isotherms of this material group has been extensively evaluated. The tested models (Peleg, Redlich, Chen, Oswin, Henderson, Lewicki, Caurie, and GAB) all provided a very good fit with the experimental results for the tested material group (R2 ranged from 0.9599 to 0.9978). This paper indicates that the use of two additional approximation parameters (SSE and RMSE) allows a more precise assessment of the quality of individual models.

1. Introduction

The properties of a building envelope made of hygroscopic materials strongly depend on the moisture content—with an increase in moisture, the thermal insulation performance of the partitions decreases (increased energy loss), and both the quality of the indoor climate (mold growth, increased VOC emissions) and the durability (physical, chemical, and biological damage) deteriorate. Therefore, significant attention has been paid to problems associated with the dampness of building materials, and in particular to the research and modeling of sorption isotherms.
Sorption isotherms describe the adsorption properties of a porous material. The shape of a sorption isotherm depends on the adsorbent microstructure (in particular, the pore size) as well as adsorbate–adsorbent interactions; therefore, different hygroscopic materials exhibit very different sorption isotherm characteristics.
Two classifications of sorption isotherms are most commonly cited in the literature: the Brunauer classification and the International Union of Pure and Applied Chemistry (IUPAC) [1,2]. The Brunauer classification includes five types of adsorption isotherms, which are shown in Figure 1.
The classification recommended by the International Union of Pure and Applied Chemistry (IUPAC) distinguishes six types of adsorption isotherms, as shown in Figure 2.
IUPAC isotherms of type I, II, and III overlap with type I, II, and III of the Brunauer classification.
A type I isotherm is produced by microporous adsorbents, where the micropores are rapidly filled at relatively low pressure. The shape of this isotherm is convex, and the amount of adsorbed gas slowly approaches a limit value as p/p0 increases. Type II isotherms display a characteristic inflection point, which indicates the moment of complete monolayer coverage and the onset of the formation of subsequent layers. Type III isotherms are produced by materials with very weak adsorbate–adsorbent interactions, and their shape is concave over the entire p/p0 range, without an inflection point.
Type IV and V isotherms exhibit a hysteresis loop and are produced by mesoporous materials in which capillary condensation occurs. At low relative pressures, a type IV isotherm corresponds to a type II isotherm, whereas a type V isotherm is characteristic of mesoporous materials, but with weak adsorbent interactions; thus, it shows some similarity with a type III isotherm.
A type VI isotherm describes multi-layer adsorption on a homogeneous surface. The steepness of the steps depends on the homogeneity of the adsorbent surface, the temperature, and the type of adsorbate [3,4,5].
Type I isotherms are best described by the Langmuir and Freundlich equations:
The Langmuir equation [3,6]:
a = a m K p 1 + K p
where: a—the amount of adsorbed substance; am—the amount of adsorbate corresponding to the coverage of the monolayer; K—the adsorption equilibrium constant; p—the adsorbate pressure.
The Freundlich equation [5,6]:
a = k p 1 n
or,
a = a m ( K p ) m
where: m, n—empirically defined heterogeneity coefficients.
Type II–V isotherms are best described by the BET (Brunauer–Emmett–Teller) equation, which has the following form [3,4,6]:
a = a m c p p 0 ( 1 p p 0 ) [ 1 + ( c 1 ) p p 0 ]
where: p/p0—relative partial pressure of water vapor; p0—saturated vapor pressure; c—constant.
The isothermal sorption of building materials (including aerated concretes) has been the subject of many research papers (e.g., [7,8,9,10,11,12,13,14,15]) that have focused on experimentally determining sorption isotherms, as well as their mathematical descriptions. In these studies, the influence of various factors on the equilibrium moisture level in a given material, e.g., autoclaved aerated concrete, was evaluated at different relative humidity levels.
Figure 3 shows examples of the sorption isotherms of several autoclaved aerated concretes that were studied in [16,17,18]. For the five different concretes presented, a relationship was discovered between the equilibrium mass humidity Um and the relative air humidity φ.
The runs illustrated in Figure 3 indicate a significant influence of aerated concrete density on the profile of the corresponding sorption isotherm. The intensification of the sorption process for concrete with the highest density of 600 kg/m3, which takes place over the entire tested humidity range φ, is worth noting.
The reverse effect is shown in Figure 4, where data were compiled to compare the sorption isotherms of aerated concrete of densities ranging from 300 to 500 kg/m3. Tests were carried out using the standard method in desiccators on 4 cm × 4 cm × 1 cm samples. Reproduced runs indicated that more aerated concretes had a higher sensitivity to moisture than class 500 concrete.
Figure 5 illustrates the seemingly opposite trend, in which the highest equilibrium moisture values were noted for the concrete with the highest density of 580 kg/m3; however, this was related to the fact that this concrete, similar to 420 kg/m3 aerated concrete, is an ash concrete, which is characterized by higher sorption moisture contents relative to sand concretes.
The available data indicate that, in addition to density, the volume of adsorbed moisture was influenced by the composition of the raw materials as well as the production process. Non-autoclaved concretes, which are made of cement and fly ash, showed higher sorption capacities. The differences may also be related to the selection of autoclaving parameters.
It should be stressed that the acquisition of sorption isotherm data of porous building materials is very time-consuming because experiments must be performed under several conditions, such as different humidities φ, that must be stably maintained for many months. For this reason, many researchers have tried to find a mathematical model that can accurately predict the sorption isotherms of a given material. Among the most popular are the models proposed by Keller [3], Henry [5,6], Freundlich [5,6], Dubinin and Raduszkiewicz [4], Redlich-Peterson [20], Kisarow [21], Hüttig [22,23], Łykow [24], Hansen [25] Chen and Chen [26], Jovanovič [27], and many others; however, not all of them are suitable for describing the isotherms of building materials.
A comprehensive summary of the selected equations, together with the results of their adaptation to various types of building materials, can be found in [16]. It presents both experimental results and approximations of sorption isotherms for the most popular building materials: silicate brick, ceramic brick, aerated concrete, cement mortar, modified mortar, and cement-lime mortar. Tests on these materials were carried out at three environmental temperatures and at six levels of relative humidity.
This extensive dataset was then used in [16] to test 24 equations to assess their accuracy in describing the isotherms of each of the six analyzed building materials. In each case, the best match with the experimental data was found for the Chen function [26].
Taking into account the favorable results given in [16], the suitability of Chen’s model for describing the sorption isotherms of the four most popular density classes of aerated concrete (400, 500, 600, and 700) was also tested. In addition to Chen’s model, a few other models were selected that appeared promising in terms of their description’s accuracy, i.e., those that have since been applied in other areas, mainly the food industry.

2. Materials and Methods

Due to the complex interactions between various material and technological factors, the initial assumptions for the planned studies were specified beforehand. The purpose of those studies was to reconstruct the isotherms of aerated concretes that differed only in density and then to assess the accuracy of their model description using equations selected from the literature. Therefore, the purpose was to eliminate side factors that may have had an uncontrollable effect on the Um equilibrium values obtained at the different φ levels tested.
We decided to conduct experiments on the most common density classes: 400, 500, 600, and 700 kg/m3, which differ only in their pore structures. To eliminate the uncontrollable influence of other material and technological factors, we ensured that all test materials came from the same manufacturer, while guaranteeing that the same raw materials were used to produce concrete in each class, as well as the same technological parameters. Thus, sorption studies were performed on samples that differed only in density. The samples of each class served as four porous model mediums designed to recreate their isotherms and then evaluate the suitability of the tested models for describing them.
The raw materials used for AAC are sand, ground quicklime, cement, gypsum, alumina powder and water. Before sorption testing, composition tests of all autoclaved aerated concretes were performed. Table 1 summarizes the data for each AAC class tested.
Sorption studies were performed using the classical gravimetric method. For these tests, 4 perpendicular samples were taken from each class with a frontal surface area of 6 cm × 12 cm and a thickness of approx. 1 cm. These samples were cut from the internal part of the blocks for each density class. The actual sample density was 407 kg/m3 for AAC 400, 495 kg/m3 for AAC 500, 569 kg/m3 for AAC 600, and 665 kg/m3 for AAC 700, respectively. After the samples were surveyed, they were dried in a dryer to a constant weight at 105 °C, then insulated on their sides with a silicone coating and re-dried to a constant weight (Figure 6a). These prepared samples were placed on racks and sealed in containers with pre-prepared saturated aqueous solutions of appropriately selected salts at the bottom. These test systems were placed in two thermostatic chambers set to 20 °C, and each chamber contained 7 containers (Figure 6b).
The standard method of sorption testing of building materials (gravimetric static method) is described by European [28] and US standards [29], which provide two alternative methods for determining the sorption properties of porous building materials: using desiccators and using a climatic chamber.
In [30], both sorption and desorption processes were studied in autoclaved aerated concretes of four density classes (400, 500, 600 and 700). The testing was carried out by two independent methods, the traditional gravimetric Saturated Salt Solution (SSS) method and the Dynamic Vapor Sorption method (DVS). A comparison of sorption isotherms determined independently by each method (SSS and DVS) is presented in [31]. Analogous comparisons concerning desorption isotherms were presented in [32]. The research results provided in [31,32] show that the dynamic method (DVS) exhibits good agreement with the traditional method (SSS) over a wide range of relative humidity, excluding the highest humidity φ > 75%, at which the DVS method provides underestimates for both sorption isotherms and desorption isotherms.
This article presents the sorption results obtained using the standard method, which uses suitable hygrostatic solutions to stabilize the environmental humidity in each of the 7 containers. Solutions were prepared using the following salts: LiCl, MgCl2, Mg(NO3)2, NaNO2, NaCl, KCl, and K2SO4. Table 2 lists the relative air humidity φ over the saturated aqueous solutions of these salts at 20 °C.
The study of the sorption processes under 7 moisture humidity conditions lasted 10 months and was finished only when each sample reached equilibrium moisture content, allowing the Um value to be determined for all samples of each of the four classes tested.
In addition to these measurements, the suitability of several selected models for describing experimentally determined sorption isotherms of the four tested density classes of aerated concrete was evaluated.
Eight models in total were selected from the literature for further analysis. Chen’s model was evaluated first, which proved to be very accurate in [16]. It can be described in the form of an equation:
U m = a φ ( 1 + b φ ) ( 1 c φ )
where: Um—mass moisture content; a, b, c—experimentally determined constants; φ = p/p0 relative air humidity; p—partial pressure of water vapor; p0—saturated vapor pressure.
In addition to Chen’s model, other models have been recommended in the literature to describe the moisture isotherms of autoclaved aerated concrete. The most commonly used models are the GAB model and the models proposed by Henderson, Oswin, and Lewicki [16,26]. These are described by Formulas (6)–(9), with the symbols represented by: Um—mass moisture content; φ—relative air humidity; a, b, c, K, F, G, H—constants used in the different models:
The GAB model:
U m = a m c K φ ( 1 K φ ) ( 1 K φ + c K φ )
The Henderson model:
U m = a ( ln ( 1 φ ) ) b
The Oswin model:
U m = a ( φ ( 1 φ ) ) b
The Lewicki model:
U m = F ( 1 ( 1 φ ) G 1 1 + φ H )
In this paper, we evaluated the accuracy of the above-mentioned five models recommended in the literature for describing the sorption isotherms of aerated concretes, as well as three additional ones. These models were selected in their own field after conducting preliminary analyses to assess their suitability. Their validity was demonstrated in other fields, mainly for modeling food sorption isotherms [35,36,37]. These were the models proposed by Peleg [38], Redlich-Peterson [20], and Caurie [39], by the following equations:
The Peleg model:
U m = k 1 φ n 1 + k 2 φ n 2
The Redlich-Peterson model:
U m = K φ 1 + B φ n
The Caurie model:
U m = e A φ + B
where: Um—mass moisture content; φ—relative air humidity; A, B, K, n, k1, k2, n1, n2—constants based on experimental tests (k1 > 1; k2 > 1; n1 > 1; 0 < n2 < 1 and 0 < φ < 1).

3. Results and Discussion

Table 3 shows the obtained Um equilibrium values derived from sorption measurements carried out on four samples from each of the tested classes, with seven humidity levels arranged in the environment of the samples by the hygrostatic solutions described above. The data in Table 3 are shown on the top graphs placed in Figures 9–12. The shape of the measured isotherms corresponded to a type III isotherm in the Brunauer and IUPAC classifications. The sigmoidal shape of the water vapor sorption curves indicated the formation of multi-molecular water layers on the pore surfaces of the tested materials. There was no clear boundary in the transition from monolayer adsorption to multilayer adsorption. In the high-humidity range, capillary condensation was observed, which intensified the course of individual equilibrium curves to varying degrees.
The data included in Table 3 were collected during a PhD thesis [30]. These results correspond to equilibrium states, obtained after storing the samples for several months under particular moisture conditions. The results refer to a total of 112 cuboidal samples 1 cm × 6 cm × 12 cm, with 28 samples from each class.
Subsequently, an attempt was made to find the best fit of the theoretical curves to the experimental points.
Table 4 summarizes the individual parameters assigned to Equations (5)–(12) for the four AAC density classes tested, for all eight models.
Table 5 summarizes the calculated R2 (coefficient of determination), SSE (Sum of Squares Due to Error), and RMSE (Root Mean Squared Error) values to better assess the accuracy of each model. The SSE is the sum of the squares of the data errors—the closer the SSE value is to zero, the better the fit is. The RMSE can be used to indicate the accuracy of the model fit to the data—the lower the RMSE, the better the model fit.
By evaluating the values for each of the three parameters (R2, SSE, and RMSE), it was possible to more thoroughly diagnose the quality of the fit for each model.
Figure 7 summarizes the SSE values of the eight models tested, which are divided into four AAC density classes.
In a similar arrangement, the RMSE values of the tested models and the different AAC density classes are presented in Figure 8.
By analyzing the R2 values in Table 5, the most unfavorable values appeared for the AAC500 density class, and the R2 values in samples taken from this material ranged from ca. 0.986 (for the Peleg and Lewicki models) to ca. 0.960 (for the Caurie model). However, it should be noted that all R2 values indicated a very good accuracy of the fit for each of the tested models and for all density classes.
A more thorough assessment was possible by applying additional factors, i.e., SSE and RMSE.
The analysis of the SSE parameter values presented in Figure 7 reveals five models that are best suited to describe the sorption isotherms for all the tested autoclaved aerated concretes. This group includes the Peleg, Redlich, GAB, Chen, and Lewicki models. Apparently weaker in the evaluation are the other three models: Oswin, Henderson and Caurie. In particular, the last two stand out negatively in terms of the SSE coefficient value.
The analogical observations concerning individual models can be made after the analysis of the RMSE parameters illustrated in Figure 8. Additionally, in this case, a group of five best suited models can be identified (Peleg, Redlich, GAB, Chen, and Lewicki) with relatively low values of RMSE parameters. The other three models, in particular the Henderson and Caurie models, do not qualify for a positive evaluation.
In-depth analysis of the data summarized in Figure 7 and Figure 8 indicates that the Peleg model has the most favorable SSE and RMSE parameters.
Figure 9, Figure 10, Figure 11 and Figure 12 show the experimental values of Um for individual concrete samples of classes 400, 500, 600, and 700, as well as graphs of the best fit of the Peleg model. Error charts are provided for each approximation.
By analyzing individual datasets, it can be concluded that due to the resulting approximation errors for each concrete, they show minimum error values at humidities φ = 11, 33, 54, 65, 75, and 85% at levels not exceeding 0.2% for AAC 400, 0.5% for AAC 500, 0.4% for AAC 600, and 0.2% for AAC 700. Slightly higher approximation errors (but still relatively low) were observed for the highest moisture level φ = 98%. Their values did not exceed 1.4% for AAC 400, 1.5% for AAC 500, 1.7% for AAC 600, and 1.0% for AAC 700.

4. Conclusions

Based on moisture sorption studies, this process was found to proceed with similar intensities in four classes of tested aerated concretes. The results indicated that the moisture content of the samples increased significantly as the relative humidity increased. The isotherms showed a gradual progression at relative humidity values below 75–85%. In contrast, a significant increase in moisture content occurred in the humidity range of 75–85% to 98%.
The sorption isotherms of all studied aerated concretes were sigmoidal and belonged to type III isotherms, according to the Brunauer and IUPAC classifications.
It should be emphasized that experimental determination of the sorption isotherms of porous building materials is very labor- and time-consuming. Testing at different humidity levels needs to be arranged and then the changing mass of samples needs to be measured systematically over a period of many months in each climate. Despite this, scientists undertake this type of research because of the relevance of sorption isotherms in the estimation of other material parameters (e.g., heat transfer coefficient), values of which are strongly related to the moisture content in the material. Therefore, among other things, the accuracy of the sorption isotherms reconstruction and the quality of the description of their course are extremely important.
This paper evaluates the quality of eight models—five (Chen, Oswin, Henderson, Lewicki, and GAB) that are recommended in the literature for the description of autoclaved aerated concrete isotherms and an additional three (Peleg, Redlich, and Caurie) that have so far been used mainly in relation to the food industry.
To assess the suitability of the analyzed models, three approximation parameters were used (R2, SSE and RMSE).
The R2 parameter is a common quality measure for a model under consideration. It takes values from 0 to 1, and the higher the value, the better the fit provided by the model. If R2 meets inequalities 0.9 < R2 < 1, the fit is considered good.
Restricted to the basic R2 parameter, every model would receive a positive recommendation due to the satisfactory R2 value ranging from 0.9599 (Caurie) to 0.9978 (Peleg).
The inclusion of the additional parameters SSE and RMSE in this analysis made it possible to carry out a more precise assessment and to identify five models (Peleg, Redlich, GAB, Chen, and Lewicki) ensuring a good quality of the sorption isotherms that fit to the determined experimental data. The lower the value of both of these approximation parameters, the more precise the description provided by the model. The values of the SSE and RMSE parameters summarized in Table 5 and visualized in Figure 7 and Figure 8 allow the selection of five models (Peleg, Redlich, GAB, Chen, and Lewicki) that ensure the sorption isotherms fit well with the experimental data. For all tested concretes (AAC 400, AAC 500, AAC 600 and AAC 700), the parameters SSE and RMSE were the lowest in Peleg’s model.
Based on the analyses carried out, it can be concluded that the Peleg method most accurately correlated the equilibrium moisture content of Um of all tested concretes with the relative air humidity φ = p/p0 across the whole hygroscopic range. The maximum approximation error was slightly above 1.5% for all experimental data.
Based on the data obtained and the conducted analyses, it is reasonable to evaluate the quality of the model on the basis of three approximation parameters, supplementing the basic parameter R2 with two additional parameters SSE and RMSE. This makes it possible to select the model that provides the most accurate description for the type of material tested.
Of course, the specific microstructural properties of the material should be considered separately. Due to the influence of the mineralogical composition and the particular microstructure of a porous material during its sorption processes, the authors plan to relate these material parameters to the sorption isotherms assigned to the individual classes of autoclaved aerated concretes tested.

Author Contributions

Conceptualization, H.G. and M.B.; methodology, H.G., M.B. and M.S.; software, M.S.; validation, M.B. and M.S.; formal analysis, H.G. and M.B.; investigation, H.G. and M.B.; resources, M.B.; data curation, M.B. and M.S.; writing—original draft preparation, M.B.; writing—review and editing, H.G.; visualization, M.B. and M.S.; supervision, H.G.; project administration, H.G.; funding acquisition, H.G. All authors have read and agreed to the published version of the manuscript.

Funding

This work was carried out as a part of the project UPB-DZS−503-12-083-05/4 (supported by West Pomeranian University of Technology in Szczecin, Poland) and as a part of project 0213/SIGR/2154 Mathematical modeling in technical science and theoretical research in mathematics (supported by Rector of Poznan University of Technology, Poland).

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

Data available in a publicly accessible repository.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Brunauer, S.; Deming, L.S.; Deming, W.E.; Teller, E. Theory of the van der Waals Adsorption of Gases. J. Am. Chem. Soc. 1940, 62, 1723–1732. [Google Scholar] [CrossRef]
  2. Sing, K.S.W. Reporting physisorption data for gas/solid systems with special reference to the determination of surface area and porosity. Pure Appl. Chem. 1982, 54, 2201–2218. [Google Scholar] [CrossRef]
  3. Keller, J.; Staudt, R. Gas Adsorption Equilibria: Experimental Methods and Adsorption Isotherms; Springer: New York, NY, USA, 2005. [Google Scholar] [CrossRef] [Green Version]
  4. Lowell, S.; Shields, J.E.; Thomas, M.A.; Thommes, M. Characterization of Porous Solids and Powders: Surface Area, Pore Size and Density; Kluwer Academic Publishers: Dordrecht, The Netherlands, 2004. [Google Scholar] [CrossRef]
  5. Rouquerol, J.; Rouquerol, F.; Sing, K. Absorption by Powders and Porous Solids; Academic Press: Cambridge, MA, USA, 1998. [Google Scholar] [CrossRef]
  6. Perry, R.H.; Green, D.W. Perry’s Chemical Engineers’ Handbook; McGraw-Hill: New York, NY, USA, 1997; ISBN 0070498415. [Google Scholar]
  7. Campanale, M.; Deganello, M.; Moro, L. Effect of Moisture Movement on Tested Thermal Conductivity of Moist Aerated Autoclaved Concrete. Transp. Porous Media 2013, 98, 125–146. [Google Scholar] [CrossRef]
  8. Chen, H.Y.; Chen, C. Equilibrium relative humidity method used to determine the sorption isotherm of autoclaved aerated concrete. Build. Environ. 2014, 81, 427–435. [Google Scholar] [CrossRef]
  9. Feng, C.; Janssen, H.; Wu, C.; Feng, Y.; Meng, Q. Validating various measures to accelerate the static gravimetric sorption isotherm determination. Build. Environ. 2013, 69, 64–71. [Google Scholar] [CrossRef] [Green Version]
  10. Giarma, C. Proposal of an empirical relationship for moisture storage function of concrete. Bauphysik 2010, 32, 160–166. [Google Scholar] [CrossRef]
  11. Gómez, I.; Sala, J.M.; Millán, J.A. Moisture storage properties of multi-slotted light-weight ceramic blocks: Comparison between two manufacturers. J. Build. Phys. 2008, 31, 225–242. [Google Scholar] [CrossRef]
  12. Kumar, A.; Ketel, S.; Vance, K.; Oey, T.; Neithalath, N.; Sant, G. Water Vapor Sorption in Cementitious Materials—Measurement, Modeling and Interpretation. Transp. Porous Media 2014, 103, 69–98. [Google Scholar] [CrossRef]
  13. Pavlík, Z.; Medved, I.; Žumár, J.; Pavlíková, M.; Černý, R. Theoretical formulas for approximation of sorption isotherms of chosen building materials. In Proceedings of the 19th International Meeting of Thermophysical Society, Podkylava, Slovak Republic, 8–10 October 2014; pp. 89–96. [Google Scholar]
  14. Pavlík, Z.; Žumár, J.; Medved, I.; Černý, R. Water vapor adsorption in porous building materials: Experimental measurement and theoretical analysis. Transp. Porous Media 2012, 91, 939–954. [Google Scholar] [CrossRef]
  15. Wang, Y.; Huang, J.; Wang, D.; Liu, Y.; Zhao, Z.; Liu, A. Experimental study on hygrothermal characteristics of coral sand aggregate concrete and aerated concrete under different humidity and temperature conditions. Constr. Build. Mater. 2020, 230, 117034. [Google Scholar] [CrossRef]
  16. Stolarska, A.; Garbalińska, H. Assessment of suitability of some chosen functions for describing of sorption isotherms in building materials. Heat Mass Transf. 2017, 53, 1603–1617. [Google Scholar] [CrossRef]
  17. Drochytka, R.; Zach, J. The study of thermal and moisture behavior of autoclaved cellular concrete. In Materials of 5th International Conference on AAC: Securing a Sustainable Future; University of Technology and Life Sciences Press: Bydgoszcz, Poland, 2011; pp. 201–206. [Google Scholar]
  18. Koronthayova, O. Moisture storage capacity and microstructure of ceramic brick and autoclaved aerated concrete. Constr. Build. Mater. 2011, 25, 879–885. [Google Scholar] [CrossRef]
  19. Jerman, M.; Keppert, M.; Výborný, J.; Černý, R. Hygric, thermal and durability properties of autoclaved aerated concrete. Constr. Build. Mater. 2013, 41, 352–359. [Google Scholar] [CrossRef]
  20. Redlich, O.; Peterson, D.L. A useful adsorption isotherm. J. Phys. Chem. 1959, 63, 1024–1026. [Google Scholar] [CrossRef]
  21. Paderewski, M.L. Adsorption Processes in Chemical Engineering; WNT: Warszawa, Poland, 1999. (In Polish) [Google Scholar]
  22. Fergusson, R.R.; Barber, R.M. Derivation and development of Huttig’s multilayer sorption isotherm. Trans. Faraday Soc. 1950, 46, 400–407. [Google Scholar] [CrossRef]
  23. Hüttig, G.F. Zur Auswertung der adsorptions-isothermen. Chem. Mon. 1948, 78, 177–184. [Google Scholar] [CrossRef]
  24. Łykow, A.W. Transporterscheinungen in Kapillarporösen Körpern; Academie: Berlin, Germany, 1958. [Google Scholar]
  25. Marynowicz, A.; Wyrwał, J. Testing the Humidity Properties of Selected Building Materials under Isothermal Conditions; Studia z Zakresu Inżynierii: Warszawa, Poland, 2005; Volume 52. (In Polish) [Google Scholar]
  26. Chen, Y.; Chen, Z. Transfer function method to calculate moisture absorption and desorption in buildings. Build. Environ. 1998, 33, 201–207. [Google Scholar] [CrossRef]
  27. Jovanović, D.S. Physical adsorption of gases. Colloid Polym. Sci. 1969, 235, 1214–1225. [Google Scholar] [CrossRef]
  28. ISO 12571. Hygrothermal Performance of Building Materials and Products—Determination of Hygroscopic Sorption Properties; European Committee for Standardization: Brussels, Belgium, 2013. [Google Scholar]
  29. ASTM E104-02(2012). Standard Practice for Maintaining Constant Relative Humidity by Means of Aqueous Solutions; ASTM International: West Conshohocken, PA, USA, 2012. [Google Scholar]
  30. Bochenek, M. Evaluation of Hygro-Thermal Properties Variability in Autoclaved Aerated Concrete of Diverse Density. Ph.D. Thesis, West Pomeranian University of Technology Szczecin, Szczecin, Poland, 2016. (In Polish). [Google Scholar]
  31. Garbalińska, H.; Bochenek, M.; Malorny, W.; Von Werder, J. Comparative analysis of the dynamic vapor sorption (DVS) technique and the traditional method for sorption isotherms determination—Exemplified at autoclaved aerated concrete samples of four density classes. Cem. Concr. Res. 2017, 91, 97–105. [Google Scholar] [CrossRef]
  32. Garbalińska, H.; Bochenek, M. Experimentelle Ermittlung der Desorptionsisothermen von Porenbeton unterschiedlicher Dichte mit der Standardmethode SSS und mit der DVS-Technik. Bauphysik 2017, 39, 191–196. [Google Scholar] [CrossRef]
  33. Greenspan, L. Humidity Fixed Points of Binary Saturated Aqueous Solutions. J. Res. Natl. Bur. Stand. A Phys. Chem. 1977, 81A, 89–96. [Google Scholar] [CrossRef]
  34. Jiřiĉková, M.; Černý, R.; Rovnaniková, P. Measurement of moisture storage parameters of building materials. Acta Polytech. 2003, 43, 39–43. [Google Scholar] [CrossRef]
  35. Soleimanifard, S.; Hamdami, N. Modelling of the sorption isotherms and determination of the isosteric heat of split pistachios, pistachio kernels and shells. Czech J. Food Sci. 2018, 36, 268–275. [Google Scholar] [CrossRef]
  36. Mutluab, C.; Koça, A.; Erbaş, M. Some physical properties and adsorption isotherms of vacuum-dried honey powder with different carrier materials. LWT 2020, 134, 110166. [Google Scholar] [CrossRef]
  37. Saleha, R.; Karim, N.A.; Hensel, O.; Sturm, B. Mathematical modelling of adsorption isotherms of Malaysian variety of purple flesh sweet potato at different temperatures. Therm. Sci. Eng. Prog. 2018, 7, 326–330. [Google Scholar] [CrossRef]
  38. Peleg, M. Assessment of a semi-empirical four parameter general model for sigmoid moisture sorption isotherms. J. Food Process. Eng. 1993, 16, 21–37. [Google Scholar] [CrossRef]
  39. Caurie, M. A new model equation for predicting safe storage moisture levels for optimum stability of dehydrated foods. J. Food Technol. 1970, 5, 301–307. [Google Scholar] [CrossRef]
Figure 1. Types of isotherms according to Brunauer, based on [1].
Figure 1. Types of isotherms according to Brunauer, based on [1].
Materials 14 06235 g001
Figure 2. The types of isotherms according to IUPAC, based on [2].
Figure 2. The types of isotherms according to IUPAC, based on [2].
Materials 14 06235 g002
Figure 3. Sorption isotherms, based on [16,17,18].
Figure 3. Sorption isotherms, based on [16,17,18].
Materials 14 06235 g003
Figure 4. Sorption isotherms of class 300, 350, and 500 kg/m3 aerated concrete, based on [19].
Figure 4. Sorption isotherms of class 300, 350, and 500 kg/m3 aerated concrete, based on [19].
Materials 14 06235 g004
Figure 5. Sorption isotherms of 300, 350, 400, and 500 kg/m3 sand-based aerated concretes and 420 and 580 kg/m3 ash-based aerated concretes, based on [17].
Figure 5. Sorption isotherms of 300, 350, 400, and 500 kg/m3 sand-based aerated concretes and 420 and 580 kg/m3 ash-based aerated concretes, based on [17].
Materials 14 06235 g005
Figure 6. Samples dried to a constant mass, located in the dryer (a) and samples in closed containers placed inside the thermostatic chamber (b). Both photographs are from the authors’ collection.
Figure 6. Samples dried to a constant mass, located in the dryer (a) and samples in closed containers placed inside the thermostatic chamber (b). Both photographs are from the authors’ collection.
Materials 14 06235 g006
Figure 7. Graphical representation of the SSE values determined for all eight models analyzed and the four AAC density classes tested (data on individual values of SSE are presented in Table 5).
Figure 7. Graphical representation of the SSE values determined for all eight models analyzed and the four AAC density classes tested (data on individual values of SSE are presented in Table 5).
Materials 14 06235 g007
Figure 8. Graphical representation of the RMSE values determined for the eight models analyzed and the four AAC density classes tested (data on individual values of RMSE are presented in Table 5).
Figure 8. Graphical representation of the RMSE values determined for the eight models analyzed and the four AAC density classes tested (data on individual values of RMSE are presented in Table 5).
Materials 14 06235 g008
Figure 9. The sorption isotherms of class 400 aerated concrete described by the Peleg equation, plotted with the approximation error.
Figure 9. The sorption isotherms of class 400 aerated concrete described by the Peleg equation, plotted with the approximation error.
Materials 14 06235 g009
Figure 10. The sorption isotherms of class 500 aerated concrete described by the Peleg equation, plotted with the approximation error.
Figure 10. The sorption isotherms of class 500 aerated concrete described by the Peleg equation, plotted with the approximation error.
Materials 14 06235 g010
Figure 11. The sorption isotherms of class 600 aerated concrete described by the Peleg equation, plotted with the approximation error.
Figure 11. The sorption isotherms of class 600 aerated concrete described by the Peleg equation, plotted with the approximation error.
Materials 14 06235 g011
Figure 12. The sorption isotherms of class 700 aerated concrete described by the Peleg equation, plotted with the approximation error.
Figure 12. The sorption isotherms of class 700 aerated concrete described by the Peleg equation, plotted with the approximation error.
Materials 14 06235 g012
Table 1. Percent phase contribution.
Table 1. Percent phase contribution.
MineralAAC 400 [%]AAC 500 [%]AAC 600 [%]AAC 700 [%]
Rutile0.040.020.050.06
Basanite3.463.055.580.74
Anhydrite9.484.823.204.23
Calcite 24.735.502.031.66
Calcite 10.730.470.181.50
Tobermorite29.0228.3529.9935.42
Quartz52.5457.7958.9756.39
Table 2. The steady-state values of relative humidity over saturated aqueous solutions of selected salts, based on [28,29,33,34].
Table 2. The steady-state values of relative humidity over saturated aqueous solutions of selected salts, based on [28,29,33,34].
Chemical FormulaName (IUPAC)T [°C]φ [%]
LiClLithium chloride2011
MgCl2Magnesium chloride2033
Mg(NO3)2Magnesium nitrate (V)2054
NaNO2Sodium (III) nitrate2065
NaClSodium chloride2075
KClPotassium chloride2085
K2SO4Potassium sulphate (VI)2098
Table 3. Stabilized sorption moisture content Um of the autoclaved aerated concretes of classes 400, 500, 600, and 700 [30].
Table 3. Stabilized sorption moisture content Um of the autoclaved aerated concretes of classes 400, 500, 600, and 700 [30].
φ [%]AAC 400AAC 500AAC 600AAC 700
Um [%]Um [%]Um [%]Um [%]
110.3780.3820.540.886
0.4860.410.4940.7
0.530.2620.6230.734
0.4350.50.5770.79
330.8220.6980.9521.126
0.910.5880.9120.992
0.9420.5790.8270.947
0.8880.6180.9871.108
541.2091.011.2441.224
1.2740.8581.1841.309
1.1040.8861.2051.44
1.2361.0791.071.43
651.3271.141.3931.363
1.5271.0671.1771.377
1.4280.9161.2691.426
1.161.2491.1791.397
751.6961.5221.5051.388
1.6081.2281.8271.461
1.5421.21.4431.486
1.3821.4941.4261.442
852.151.7272.2011.937
1.9882.2982.1451.973
1.9872.0742.4121.973
1.9981.5532.1062.224
9815.89413.15714.80417.788
16.13410.90517.3317.911
15.93210.29117.05816.262
14.14312.50717.06616.888
Table 4. Summary of the determined coefficients of the analyzed models for the tested aerated concretes.
Table 4. Summary of the determined coefficients of the analyzed models for the tested aerated concretes.
Model ParameterAAC 400AAC 500AAC 600AAC 700
Pelegk122.715.4122.9925.37
k21.8131.5341.6391.594
n124.8720.3921.3323.98
n20.63870.72610.50990.3354
RedlichK−1.212−1.036−1.1−1.359
B2.1831.7382.1142.265
n16.859.52311.3522.03
Chena1.21 × 1041.54 × 1051.21 × 1061.50 × 106
b3.20 × 1044.57 × 1053.13 × 1063.93 × 106
c0.99560.9910.99650.9978
Oswina0.63460.59980.63430.6084
b0.82080.7630.83770.8581
Hendersona0.61350.62010.61440.5539
b2.3662.1512.4132.517
LewickiF0.4394−0.93195.941−11.82
G0.9144−3.3410.9914−0.1096
H−6.5714.1031.09831.87
CaurieA2.93 × 10−511.7613.5614.5
B13.44−9.073−10.49−11.39
GABam0.37730.33750.3880.3811
c3.03 × 1064.75× 1053.27× 1064.16× 106
K0.99560.9910.99650.9978
Table 5. Summary of SSE, R2, and RMSE approximation parameters for the analyzed models and the tested aerated concretes.
Table 5. Summary of SSE, R2, and RMSE approximation parameters for the analyzed models and the tested aerated concretes.
AAC 400AAC 500AAC 600AAC 700
PelegSSE2.7726.0154.4641.992
R20.99630.98580.99480.9978
RMSE0.31460.46350.39930.2667
RedlichSSE3.1246.135.1583.791
R20.99580.98560.99350.9959
RMSE0.32820.45980.42180.3616
ChenSSE4.8836.5185.8955.781
R20.99340.98470.99310.9937
RMSE0.41040.47410.45090.4465
OswinSSE7.1557.3778.4659.884
R20.99010.98260.99010.9892
RMSE0.48840.49590.53120.574
HendersonSSE13.6411.0114.5917.47
R20.98170.97410.98290.9809
RMSE0.67420.60570.69740.7632
LewickiSSE4.9336.0037.7195.796
R20.99340.98590.9910.9937
RMSE0.41240.4550.51590.4471
CaurieSSE22.4117.0322.9426.06
R20.96990.95990.97310.9715
RMSE0.86440.75330.87440.932
GABSSE4.8836.5185.8955.781
R20.99340.98470.99310.9937
RMSE0.41040.47410.45090.4465
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Garbalińska, H.; Bochenek, M.; Stasiak, M. Experimental and Modeling Investigations on the Water Sorption Behaviors of Autoclaved Aerated Concrete. Materials 2021, 14, 6235. https://doi.org/10.3390/ma14216235

AMA Style

Garbalińska H, Bochenek M, Stasiak M. Experimental and Modeling Investigations on the Water Sorption Behaviors of Autoclaved Aerated Concrete. Materials. 2021; 14(21):6235. https://doi.org/10.3390/ma14216235

Chicago/Turabian Style

Garbalińska, Halina, Magdalena Bochenek, and Marcin Stasiak. 2021. "Experimental and Modeling Investigations on the Water Sorption Behaviors of Autoclaved Aerated Concrete" Materials 14, no. 21: 6235. https://doi.org/10.3390/ma14216235

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop