Next Article in Journal
The Role of BDNF as a Biomarker in Cognitive and Sensory Neurodegeneration
Next Article in Special Issue
Predicting Hospital Ward Admission from the Emergency Department: A Systematic Review
Previous Article in Journal
Augmentative Plating versus Exchange Intramedullary Nailing for the Treatment of Aseptic Non-Unions of the Femoral Shaft—A Biomechanical Study in a SawboneTM Model
Previous Article in Special Issue
Monitoring Perfusion Index in Patients Presenting to the Emergency Department Due to Drug Use
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Brief Report

Hemolysis Control in the Emergency Department by Interventional Blood Sampling

1
Department of Emergency Medicine, Guri Hospital, Hanyang University College of Medicine, Guri 11923, Republic of Korea
2
Department of Emergency Medicine, Yongin Severance Hospital, Yongin 16995, Republic of Korea
3
Department of Philosophy, University of Nevada, Las Vegas, NV 89154, USA
*
Authors to whom correspondence should be addressed.
These authors contributed equally to this work.
J. Pers. Med. 2023, 13(4), 651; https://doi.org/10.3390/jpm13040651
Submission received: 27 March 2023 / Revised: 5 April 2023 / Accepted: 8 April 2023 / Published: 10 April 2023
(This article belongs to the Collection Advances of Emergency and Intensive Care)

Abstract

:
The hemolysis rate in the emergency department (ED) is higher compared to that in other departments. We propose a new blood sampling technique without repeated venipuncture to reduce hemolysis and compare the hemolysis rate between blood collected by this method and that collected with an intravenous (IV) catheter. This prospective study included a nonconsecutive sample of patients visiting the ED (aged ≥ 18 years) of a tertiary urban university hospital. The intravenous catheterization was performed by three pre-trained nurses. The new blood collection technique involved sample collection without removing the catheter needle, performed immediately before the conventional method (through an IV catheter), without additional venipuncture. Two blood samples were collected from each patient using both the new and conventional methods, and the hemolysis index was evaluated. We compared the hemolysis rate between the two methods. From the 260 patients enrolled in this study, 147 (56.5%) were male, and the mean age was 58.3 years. The hemolysis rate of the new blood collection method was 1.9% (5/260), which was significantly lower than that of the conventional method (7.3%; 19/260) (p = 0.001). The new blood collection method can reduce the hemolysis rate as compared to the conventional blood collection method.

1. Introduction

During hemolysis, red blood cell (RBC) membranes rupture, resulting in the release of hemoglobin (Hb) into the serum. Inappropriate blood sample collection is a major cause of hemolysis and the primary cause of sample rejection, accounting for approximately 60% of rejected specimens [1,2,3].
The American Society of Clinical Pathology has defined a hemolysis rate of ≤2% as the benchmark for the best sample collection practice. However, several studies have reported a hemolysis rate of >2% in the emergency departments (EDs) of hospitals, and the hemolysis rate in EDs has been reported predominantly in comparison to that in other departments [2,4,5,6,7]. We hypothesize that the blood collection method in EDs may contribute to the high hemolysis rate. Blood samples are mainly collected using a straight stick needle in other departments (the standard method), while in EDs, they are mainly collected using peripheral intravenous (IV) catheters, wherein the line is initiated to increase efficiency and decrease patient discomfort by avoiding a second venipuncture (the conventional method) (Figure 1).
Drawing blood through IV catheters is associated with a significantly higher risk of hemolysis than via the conventional method using straight stick needles [8,9,10,11]. Nevertheless, blood sample collection via an IV catheter has been conventionally used and accepted as a standard nursing practice in EDs. This is because drawing blood with a straight stick needle requires repeated venipuncture, increasing patient discomfort and ED workload [8]. These disadvantages are more prominent in patients with difficult venipuncture access, who are admitted predominantly to the ED [8]. Moreover, repeated blood sampling with straight stick needles (the standard method) is difficult in EDs in general. Therefore, in this study, we proposed a new blood sampling technique to reduce hemolysis without repeated venipuncture and compared the hemolysis rate between the new blood collection method and the conventional method using an IV catheter.

2. Material and Methods

2.1. Study Design and Setting

This prospective study included a nonconsecutive sample of patients admitted to the ED from March 2020 to May 2020 in a tertiary urban university hospital, which has an average of approximately 50,000 visits per year. It was ethically approved by the Institutional Review Board of the Hanyang University Guri Hospital in September 2018 (Gyeonggi-do, Republic of Korea; 25 September 2018). Prior to the start of the experiment, informed consent was collected from both the enrolled patients and the practitioners (nurses and laboratory technicians).

2.2. Study Population

The participants of this study were patients (aged ≥ 18 years) admitted between 9:00 a.m. and 12:00 p.m. on working days, requiring blood sampling for laboratory tests. Patients with underlying diseases or conditions that affect hemolysis, including autoimmune hemolytic anemia, sickle cell disorder, thalassemia, hereditary spherocytosis, and pyruvate kinase deficiency, were excluded. Patients with hyperacute symptoms, including chest pain, dyspnea, focal neurologic deficits, and altered mental status, were also not included, as it is difficult to obtain informed consent from these patients in an emergency setting.

2.3. Study Protocol and Data Collection

According to our experimental protocol, three nurses with >5 years of clinical experience in the ED performed the blood collections. Prior to the study, the nurses completed a retraining course that included the new blood sampling method implemented in this study. They placed an IV catheter (BD Angiocath PlusTM; Becton Dickinson Infusion Therapy Systems Inc., Sandy, UT, USA) in an upper or lower limb vein and collected blood according to the following protocol: (1) applied a tourniquet and inserted a catheter into the patient’s upper or lower limb; (2) in the case of flashback, removed the catheter lever lock plug; (3) connected a syringe and removed the tourniquet; (4) drew blood using a stylet needle (specimen 1); (5) threaded the catheter and withdrew the stylet needle; (6) connected a new syringe and drew blood again (specimen 2); (7) collected each specimen in a new vacutainer and rotated; (8) labelled the vacutainer with a randomly preassigned number; (9) transferred the vacutainer to the core laboratory immediately after collection using a pneumatic tube; (10) contacted the laboratory technician directly (Figure 2).
In accordance with the protocol, the laboratory technician collected the two vacutainers as soon as they were contacted and centrifuged them according to the manufacturer’s instructions. The Hb level in the samples was also quantified as the hemolysis index (HI) using the chemistry analyzer AU5800 (Beckman Coulter, Brea, CA, USA). Based on previous studies, the association between the HI value and the concentration of free Hb was considered as follows: HI value of 0, Hb < 50 mg/dL; HI value of 1, Hb < 100 mg/dL; HI value of 2, Hb < 200 mg/dL; HI value of 3, Hb < 300 mg/dL; HI value of 4, Hb < 400 mg/dL; HI value of 5, Hb > 500 mg/dL [12,13]. The laboratory technicians were blinded to the study specimens and phlebotomy techniques. They only recorded the patients’ identification numbers, assessed the time and HI values, and randomly assigned the number of each vacutainer (specimen).
The data, including patient information (sex, age, underlying diseases, blood pressure, and presenting symptoms), were recorded in a predesigned form. The location of the IV catheterization (upper arm, antecubital, forearm, hand, or leg), catheter size (18–24 gauge), and catheterization difficulty (1 = very easy; 2 = easy; 3 = neither easy nor difficult; 4 = difficult; 5 = very difficult) were also recorded. All of the data were collected daily by the researcher CK.

2.4. Main Outcome

Blood samples with >100 mg/dL of free Hb can cause non-specific binding in laboratory tests. Therefore, serological testing is not recommended for these serum samples [14]. By the biochemical protocol of our institution, detailed serologic testing is not performed for samples with an HI of grade 2 (≥100 mg/dL of Hb) or above. Therefore, hemolysis was defined as an HI of grade 2 or higher. The presence of hemolysis was compared between the two methods.

2.5. Statistical Analyses

The continuous variables were presented as means and standard deviations (SDs), and the categorical variables were presented as frequencies and percentages (%). The statistical analysis included the Wilcoxon test for the paired samples (for the continuous variables) and the McNemar test for the paired samples (for the categorical data). The statistical analyses were conducted using SPSS (version 27.0 for Windows, Chicago, IL, USA). The statistical significance was set at a p value of <0.05.

3. Results

3.1. Demographics and Baseline Characteristics

Overall, 260 patients were enrolled in this study (Figure 3). Of these, 56.5% were male, and the mean age was 58.3 ± 20.3 (SD) years. Of the total patients enrolled, 19.6%, 16.5%, and 7.3% of the patients had pre-existing hypertension, diabetes mellitus, and renal insufficiency, respectively. The presenting symptoms included abdominal pain (68.1%), dizziness (18.8%), headache (8.1%), and others (5.0%).
The IV catheterization details (IV catheterization location, size, and difficulty) are presented in Table 1. Approximately three-quarters (72.3%) of the patients underwent catheterization in the antecubital fossa (40.0%) and forearm (32.3%). A large-gauge IV catheter (18 gauge) was used in 84.6% of the patients. The nurses reported that most (97.3%) of the IV catheterizations were not difficult.

3.2. Main Outcome

A comparison of the HI between the new and conventional blood collection methods is presented in Table 2. The hemolysis rate of the new blood collection method was 1.9%, which was significantly lower than that of the conventional method via an IV catheter (7.3%) (p = 0.001). The mean HI value of the new blood collection method was 0.16 ± 0.026, which was significantly lower than that of the conventional method via the IV catheter (0.36 ± 0.046) (p < 0.001).

4. Discussion

The new blood collection method proposed in this study reduced the hemolysis rate (by 1.9%) compared to the conventional blood collection method using an IV catheter (7.3%) (p = 0.003). Similar to our results, previous studies have reported an ED hemolysis rate higher (6–30%) than the 2% benchmark established by the American Society for Clinical Pathology [2,4,5,6,7]. Although the reasons for the higher hemolysis rates in EDs are likely multifactorial, blood collection using an IV catheter has been proposed to greatly contribute to them. Johnson & Johnson explained the cause of the high hemolysis rates with the use of straight stick needles. As catheter material development technologies advance, softer plastic has been used in catheters to reduce irritation to the inner walls of blood vessels. Softer catheters can be used well under positive pressure conditions for the administration of fluids or drugs, but they can collapse under negative pressure conditions, including blood collection, resulting in turbulence and hemolysis. Thus, hemolysis caused by using an IV catheter is greater than that caused by using a straight stick needle, which provides an intact inner lumen unchanged by negative pressure [5]. The new blood collection method proposed here can also provide an intact inner lumen during negative pressure conditions of blood sampling without the need for a second needle insertion, thereby lowering the hemolysis rate by reducing turbulence.
Hemolysis is the breakdown of RBCs, which can affect laboratory results. Blood samples with >100 mg/dL of hemoglobin can cause non-specific binding in serologic tests, causing sample rejection and resulting in unnecessary repeated testing. It causes additional patient discomfort, higher costs, increased ED workload, delays in definitive acute care, and an increased ED stay. These delays severely affect patients with time-sensitive diseases, including myocardial infarction and acute stroke [2,15]. Although blood samples with HI values of 1 (Hb concentration: 50–100 mf/dL) are not rejected by laboratories, they can also produce unreliable test results. Perovic et al. reported that hemolysis significantly affected the values of α-amylase, alkaline phosphatase, aspartate aminotransferase, bilirubin, creatine kinase (CK), CK-MB, gamma-glutamyl transferase, iron, lactate dehydrogenase, magnesium, potassium, total protein, and uric acid, even at HI = 1 [16]. Moreover, Bais et al. reported that contemporary troponin-I and high-sensitivity troponin-T tests were sufficiently affected at relatively low degrees of hemolysis based on their tests [15]. Thus, although reduction of the rejection rate is important, reduction of the HI value itself (the degree of hemolysis) is also important. The median HI value of the new method was 0.16 ± 0.026 in this study, which was significantly lower than that of the conventional method (0.36 ± 0.049).
A peripheral IV catheter, 20 gauge or larger, placed in the antecubital fossa or forearm is recommended for contrast computed tomography (CT), because a flow rate of 3 mL/s or higher is necessary for injecting contrast media [17]. Contrast CT scans are widely used during ED management [18,19,20]; thus, a 20-gauge or larger IV catheter is usually preferred in EDs. At our institution, an 18-gauge catheter has been primarily used for IV lines, and it was most frequently used (84.6%) during the study period. Small-sized catheters (22 or 24 gauge) were also inserted in some patients with thin or fragile blood vessels (15.4%).
The internal diameter of the straight stick needles used in this study was smaller than that of the outside catheter. The 18-gauge catheter usually has a 20-gauge inside needle. A small catheter diameter may cause higher hemolysis. A small internal diameter can result in a large negative force being applied to the blood, inducing shear stress on the RBCs during blood sampling [21,22]. Thus, the smaller diameter of the inside straight needle than the outside catheter may offset the effect of the straight needle on reducing hemolysis. However, this phenomenon (size-dependent effect) was not observed when a sufficiently large gauge needle (18–22 gauge) was used [22]. Thus, most of the results with an 18-gauge catheter may not be significantly affected by the difference in size between the outer catheter (18 gauge) and the inner needle (20 gauge). However, the results obtained with the 22- and 24-gauge catheters could be affected. Thus, the results of this study may be difficult to apply to the small-gauge catheter (22 gauge or smaller) used during the blood sampling. The sample size for blood sampling using small-gauge catheters was small in this study; thus, further research is needed.
In laboratories, it is common practice to detect and report hemolysis using visual inspection of the specimens after centrifugation and comparing them with the hemolytic chart. However, visual assessment is subjective, and several studies have reported little agreement between the actual hemoglobin levels and the hemolysis grades [23,24]. In this study, the degree of hemolysis was determined using the HI for consistency between the laboratory technicians; this method has been proven to be accurate for identifying the level of hemolysis [13,25].
This study had some limitations. Inexperienced nurses may pull the syringe strongly or have long tourniquet times, which can affect the degree of hemolysis [5]. In this study, only three experienced nurses were involved in the catheterization practice to reduce the inexperience bias. Nevertheless, bias due to differences in practitioners cannot be excluded.
Most patients (95%) included in this study complained of abdominal pain (68.1%), dizziness (18.8%), and headache (8.1%). As all types of patients visiting the ED were not included in the study, the results of this study may not be generalizable to all ED situations.

5. Conclusions

The new blood collection method can reduce the hemolysis rate as compared to the conventional blood collection method using an IV catheter.

Study Approval

The study was ethically approved by the Institutional Review Board of the Hanyang University Guri Hospital in September 2018 (Gyeonggi-do, Republic of Korea; 2018-09-025). Prior to the start of the experiment, informed consent was collected from both the enrolled patients and the practitioners (nurses and laboratory technicians).

Author Contributions

Formal analysis, investigation, data curation, writing—original draft preparation, H.L. (Hyeseung Lee); methodology, formal analysis, investigation, writing—original draft preparation, H.L. (Heekyung Lee); conceptualization, methodology, formal analysis, writing—original draft preparation, supervision, C.K.; validation, formal analysis, H.S.; investigation, visualization, I.L.; formal analysis, Y.K. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Institutional Review Board Statement

It was ethically approved by the Institutional Review Board of the Hanyang University Guri Hospital in September 2018 (Gyeonggi-do, Republic of Korea; 2018-09-025).

Informed Consent Statement

Prior to the start of the experiment, informed consent was collected from both the enrolled patients and the practitioners (nurses and laboratory technicians).

Data Availability Statement

The datasets used and/or analyzed during the current study are available from the corresponding author on reasonable request.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. CLSI. Procedures for the Collection of Diagnostic Blood Specimens by Venipuncture; Approved Standard, 6th ed.; CLSI Document h3; Clinical and Laboratory Standards Institute: Wayne, PA, USA, 2007; Volume A6. [Google Scholar]
  2. Carraro, P.; Servidio, G.; Plebani, M. Hemolyzed specimens: A reason for rejection or a clinical challenge? Clin. Chem. 2000, 46, 306–307. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  3. Jones, B.A.; Calam, R.R.; Howanitz, P.J. Chemistry specimen acceptability: A College of American Pathologists Q-Probes study of 453 laboratories. Arch. Pathol. Lab. Med. 1997, 121, 19–26. [Google Scholar]
  4. Lippi, G.; Salvagno, G.L.; Favaloro, E.J.; Guidi, G.C. Survey on the prevalence of hemolytic specimens in an academic hospital according to collection facility: Opportunities for quality improvement. Clin. Chem. Lab. Med. 2009, 47, 616–618. [Google Scholar] [CrossRef] [PubMed]
  5. Grant, M.S. The effect of blood drawing techniques and equipment on the hemolysis of ED laboratory blood samples. J. Emerg. Nurs. 2003, 29, 116–121. [Google Scholar] [CrossRef] [PubMed]
  6. Heyer, N.J.; Derzon, J.H.; Winges, L.; Shaw, C.; Mass, D.; Snyder, S.R.; Epner, P.; Nichols, J.H.; Gayken, J.A.; Ernst, D.; et al. Effectiveness of practices to reduce blood sample hemolysis in EDs: A laboratory medicine best practices systematic review and meta-analysis. Clin. Biochem. 2012, 45, 1012–1032. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  7. Söderberg, J.; Jonsson, P.A.; Wallin, O.; Grankvist, K.; Hultdin, J. Haemolysis index—An estimate of preanalytical quality in primary health care. Clin. Chem. Lab. Med. 2009, 47, 940–944. [Google Scholar] [CrossRef] [Green Version]
  8. Lowe, G.; Stike, R.; Pollack, M.; Bosley, J.; O’Brien, P.; Hake, A.; Landis, G.; Billings, N.; Gordon, P.; Manzella, S.; et al. Nursing blood specimen collection techniques and hemolysis rates in an emergency department: Analysis of venipuncture versus intravenous catheter collection techniques. J. Emerg. Nurs. 2008, 34, 26–32. [Google Scholar] [CrossRef]
  9. Lippi, G.; Cervellin, G.; Mattiuzzi, C. Critical review and meta-analysis of spurious hemolysis in blood samples collected from intravenous catheters. Biochem. Med. 2013, 23, 193–200. [Google Scholar] [CrossRef] [Green Version]
  10. Kennedy, C.; Angermuller, S.; King, R.; Noviello, S.; Walker, J.; Warden, J.; Vang, S. A comparison of hemolysis rates using intravenous catheters versus venipuncture tubes for obtaining blood samples. J. Emerg. Nurs. 1996, 22, 566–569. [Google Scholar] [CrossRef]
  11. Halm, M.A.; Gleaves, M. Obtaining blood samples from peripheral intravenous catheters: Best practice? Am. J. Crit. Care 2009, 18, 474–478. [Google Scholar] [CrossRef] [Green Version]
  12. Lippi, G.; Avanzini, P.; Cervellin, G. Prevention of hemolysis in blood samples collected from intravenous catheters. Clin. Biochem. 2013, 46, 561–564. [Google Scholar] [CrossRef] [PubMed]
  13. Nikolac Gabaj, N.; Miler, M.; Vrtarić, A.; Hemar, M.; Filipi, P.; Kocijančić, M.; Šupak Smolčić, V.; Ćelap, I.; Šimundić, A.M. Precision, accuracy, cross reactivity and comparability of serum indices measurement on Abbott Architect c8000, Beckman Coulter AU5800 and Roche Cobas 6000 c501 clinical chemistry analyzers. Clin. Chem. Lab. Med. 2018, 56, 776–788. [Google Scholar] [CrossRef] [PubMed]
  14. A Quick-Reference Tool for Hemolysis Status. CDC; Division of Vector-borne Diseases; National Center for Emerging and Zoonotic Infectious Diseases. n.d. Available online: https://www.cdc.gov/ncezid/dvbd/stories/research-lab-diagnostics/hemolysis-palette.html (accessed on 23 February 2023).
  15. Phelan, M.P.; Hustey, F.M.; Good, D.M.; Reineks, E.Z. Seeing red: Blood sample hemolysis is associated with prolonged emergency department throughput. J. Appl. Lab. Med. 2020, 5, 732–737. [Google Scholar] [CrossRef] [PubMed]
  16. Perović, A.; Dolčić, M. Influence of hemolysis on clinical chemistry parameters determined with Beckman Coulter tests—Detection of clinically significant interference. Scand. J. Clin. Lab. Investig. 2019, 79, 154–159. [Google Scholar] [CrossRef]
  17. Marshall, T.; Chen, N.M.; Nguyen, E.; Slattery, D.E.; Zitek, T. Rethinking intravenous catheter size and location for computed tomography pulmonary angiography. West J. Emerg. Med. 2019, 20, 244–249. [Google Scholar] [CrossRef]
  18. Lee, S.I.; Kim, J.J.; Yang, H.J.; Lee, K. Spontaneous dissection of celiac trunk with concurrent splenic artery dissection. Clin. Exp. Emerg. Med. 2015, 2, 256–259. [Google Scholar] [CrossRef]
  19. Yumoto, T.; Ihoriya, H.; Tanabe, R.; Naito, H.; Nakao, A. Higher enhanced computed tomography attenuation value of the aorta is a predictor of massive transfusion in blunt trauma patients. Clin. Exp. Emerg. Med. 2019, 6, 330–339. [Google Scholar] [CrossRef]
  20. Chung, J.; Na, J.U.; Lee, J.H.; Han, S.K.; Choi, P.C.; Shin, D.H. Clinical study on ureteritis observed in contrast-enhanced computed tomography in the emergency department. Clin. Exp. Emerg. Med. 2022, 9, 216–223. [Google Scholar] [CrossRef]
  21. Dale, J.C.; Novis, D.A. Outpatient phlebotomy success and reasons for specimen rejection. Arch. Pathol. Lab. Med. 2002, 126, 416–419. [Google Scholar] [CrossRef]
  22. Shah, K.G.; Idrovo, J.P.; Nicastro, J.; McMullen, H.F.; Molmenti, E.P.; Coppa, G. A retrospective analysis of the incidence of hemolysis in type and screen specimens from trauma patients. Int. J. Angiol 2009, 18, 182–183. [Google Scholar] [CrossRef] [Green Version]
  23. Glick, M.R.; Ryder, K.W.; Glick, S.J.; Woods, J.R. Unreliable visual estimation of the incidence and amount of turbidity, hemolysis, and icterus in serum from hospitalized patients. Clin. Chem. 1989, 35, 837–839. [Google Scholar] [CrossRef] [PubMed]
  24. Hawkins, R. Discrepancy between visual and spectrophotometric assessment of sample haemolysis. Ann. Clin. Biochem. 2002, 39, 521–522. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  25. Du, Z.; Liu, J.; Zhang, H.; Bao, B.; Zhao, R.; Jin, Y. Determination of hemolysis index thresholds for biochemical tests on Siemens Advia 2400 chemistry analyzer. J. Clin. Lab. Anal. 2019, 33, e22856. [Google Scholar] [CrossRef] [PubMed] [Green Version]
Figure 1. The standard blood collection method (A) and the conventional blood collection method in EDs (B).
Figure 1. The standard blood collection method (A) and the conventional blood collection method in EDs (B).
Jpm 13 00651 g001
Figure 2. The blood sampling protocol in this study: the new blood collection method (2, 3) and the conventional blood sampling (4, 5) method.
Figure 2. The blood sampling protocol in this study: the new blood collection method (2, 3) and the conventional blood sampling (4, 5) method.
Jpm 13 00651 g002
Figure 3. Flowchart of the study. ED, emergency department; IV, intravenous.
Figure 3. Flowchart of the study. ED, emergency department; IV, intravenous.
Jpm 13 00651 g003
Table 1. Baseline characteristics of the study participants.
Table 1. Baseline characteristics of the study participants.
VariablesValue
Age, year, mean (SD)59.3 (20.3)
Sex, male, n (%)147 (56.5)
Underlying diseases, n (%)
hypertension51 (19.6)
DM43 (16.2)
renal insufficiency19 (7.3)
Presenting symptoms, n (%)
abdominal pain177 (68.1)
dizziness49 (18.8)
headache21 (8.1)
etc.13 (5.0)
Blood pressure, mmHg, mean (SD)
systolic 136 (30.7)
diastolic79 (16.3)
Location of IV catheterization, n (%)
Upper arm2 (0.8)
antecubital104 (40.0)
forearm84 (32.3)
hand65 (25.0)
leg5 (1.9)
Catheter size, n (%)
18 gauge220 (84.6)
22 gauge18 (6.9)
24 gauge22 (8.5)
Difficulty of Catheterization, n (%)
very easy185 (71.2)
easy39 (15.0)
neither easy nor difficult29 (11.2)
difficult6 (2.3)
very difficult1 (0.4)
IV, intravenous; SD, standard deviation.
Table 2. Comparison of the hemolysis index between the new blood collection method and the conventional blood collection method.
Table 2. Comparison of the hemolysis index between the new blood collection method and the conventional blood collection method.
Blood Collection Method
New MethodConventional Method Using IV Catheterp Value
Hemolysis Index (HI)
0224 (86.1)199 (76.5)
131 (11.9)42 (16.2)
23 (1.2)7 (2.7)
32 (0.8)9 (3.5)
403 (1.2)
500
Non-hemolysis vs. hemolysis
non-hemolysis (HI ≤ 1)255 (98.1)241 (92.7)0.001
hemolysis (HI ≥ 2)5 (1.9)19 (7.3)
Mean of HI (SD)0.16 (0.026)0.36 (0.049)<0.001
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Lee, H.; Lee, H.; Kim, C.; Shin, H.; Lee, I.; Kim, Y. Hemolysis Control in the Emergency Department by Interventional Blood Sampling. J. Pers. Med. 2023, 13, 651. https://doi.org/10.3390/jpm13040651

AMA Style

Lee H, Lee H, Kim C, Shin H, Lee I, Kim Y. Hemolysis Control in the Emergency Department by Interventional Blood Sampling. Journal of Personalized Medicine. 2023; 13(4):651. https://doi.org/10.3390/jpm13040651

Chicago/Turabian Style

Lee, Hyeseung, Heekyung Lee, Changsun Kim, Hyungoo Shin, Inhye Lee, and Yihyun Kim. 2023. "Hemolysis Control in the Emergency Department by Interventional Blood Sampling" Journal of Personalized Medicine 13, no. 4: 651. https://doi.org/10.3390/jpm13040651

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop