Next Article in Journal
A Structural Model for Aggression in Middle School Students in Korea: Based on Ajzen’s Theory of Planned Behavior
Next Article in Special Issue
Scanning Electron Microscope Examination as an Alternative to Classical Microbiology in the Diagnostics of Catheter-Related Sepsis?
Previous Article in Journal
The Association between Academic Schedule and Physical Activity Behaviors in University Students
Previous Article in Special Issue
High Frequency of Antibiotic Resistance Genes (ARGs) in the Lerma River Basin, Mexico
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Environmental Dissemination of SARS-CoV-2 in a University Hospital during the COVID-19 5th Wave Delta Variant Peak in Castile-León, Spain

by
Priscilla Gomes da Silva
1,2,3,4,5,*,
José Gonçalves
6,7,
Andrés Torres Franco
6,7,
Elisa Rodriguez
6,7,
Israel Diaz
6,7,
Antonio Orduña Domingo
8,
Sonsoles Garcinuño Pérez
9,
Gabriel Alberto March Roselló
9,
Carlos Jesús Dueñas Gutiérrez
10,
Maria São José Nascimento
11,
Sofia I.V. Sousa
4,5,
Pedro Garcia Encina
6,7 and
João R. Mesquita
1,2,3,*
1
ICBAS—School of Medicine and Biomedical Sciences, Porto University, 4050-313 Porto, Portugal
2
Epidemiology Research Unit (EPIunit), Institute of Public Health, University of Porto, 1800-412 Porto, Portugal
3
Laboratório para a Investigação Integrativa e Translacional em Saúde Populacional (ITR), 1800-412 Porto, Portugal
4
LEPABE—Laboratory for Process Engineering, Environment, Biotechnology and Energy, Faculty of Engineering, University of Porto, 1800-412 Porto, Portugal
5
ALiCE—Associate Laboratory in Chemical Engineering, Faculty of Engineering, University of Porto, 1800-412 Porto, Portugal
6
Institute of Sustainable Processes, Valladolid University, Dr. Mergelina S/N., 47011 Valladolid, Spain
7
Department of Chemical Engineering and Environmental Technology, University of Valladolid, Dr. Mergelina s/n., 47011 Valladolid, Spain
8
Microbiology Service, Valladolid University Clinical Hospital (HCUV), Faculty of Medicine, University of Valladolid, 47011 Valladolid, Spain
9
Microbiology Service, Valladolid University Clinical Hospital (HCUV), 47011 Valladolid, Spain
10
Internal Medicine, Infectious Diseases Section, Valladolid University Clinical Hospital (HCUV), 47011 Valladolid, Spain
11
Faculty of Pharmacy, University of Porto, 1800-412 Porto, Portugal
*
Authors to whom correspondence should be addressed.
Int. J. Environ. Res. Public Health 2023, 20(2), 1574; https://doi.org/10.3390/ijerph20021574
Submission received: 26 December 2022 / Revised: 11 January 2023 / Accepted: 13 January 2023 / Published: 15 January 2023

Abstract

:
The dominant SARS-CoV-2 Delta variant (B.1.617.2) became the main circulating variant among countries by mid 2021. Attention was raised to the increased risk of airborne transmission, leading to nosocomial outbreaks even among vaccinated individuals. Considering the increased number of COVID-19 hospital admissions fueled by the spread of the variant, with Spain showing the highest COVID-19 rates in mainland Europe by July 2021, the aim of this study was to assess SARS-CoV-2 environmental contamination in different areas of a University Hospital in the region of Castile-León, Spain, during the peak of the 5th wave of COVID-19 in the country (July 2021). Air samples were collected from sixteen different areas of the Hospital using a Coriolis® μ air sampler. Surface samples were collected in these same areas using sterile flocked plastic swabs. RNA extraction followed by a one-step RT-qPCR were performed for detection of SARS-CoV-2 RNA. Of the 21 air samples, only one was positive for SARS-CoV-2 RNA, from the emergency waiting room. Of the 40 surface samples, 2 were positive for SARS-CoV-2 RNA, both from the microbiology laboratory. These results may be relevant for risk assessment of nosocomial infection within healthcare facilities, thus helping prevent and minimize healthcare staff’s exposure to SARS-CoV-2, reinforcing the importance of always wearing appropriate and well-fit masks at all times and proper PPE when in contact with infected patients.

1. Introduction

In the beginning of the COVID-19 pandemic, it was thought that SARS-CoV-2 transmission occurred through direct, indirect, or close contact with infected people, mostly by droplets and fomites [1] and regular and thorough hand hygiene, wearing masks, and social distancing proving to be effective ways for preventing SARS-CoV-2 infection [2,3,4,5].
As the COVID-19 pandemic progressed and more data about SARS-CoV-2 became available, alarms were raised on the importance of airborne transmission [6], especially considering that SARS-CoV-2 replication occurs primarily in the respiratory tract [7,8] and its high degree of genetic similarities with SARS-CoV [9], which had been reported as being airborne in several studies during the SARS outbreak of 2002/2003 [10,11,12,13,14]. Currently, airborne transmission of SARS-CoV-2 has been accepted as a mode of transmission [15,16], being frequently associated with poorly ventilated and/or crowded indoor environments, where people tend to stay for longer periods of time [16].
In addition to that, the emergence of SARS-CoV-2 variants of concern that caused more infections and spread faster led to infection waves worldwide. Among these variants, the Delta variant (B.1.617.2), which was first reported in India in October 2020 and classified as a “variant of concern (VOC)” by the WHO on 11 May 2021 [17], rapidly spread around the globe, becoming the dominant variant circulating among countries by mid 2021 [18], and being responsible for the record-high cases reported in most European countries during 2021 [19]. This was attributed mainly to the fact that the Delta variant is more transmissible and is excreted in higher viral loads in those infected than the previously identified VOCs [20,21,22]. Moreover, some studies have reported that Delta have higher aerosol and surface stability, meaning that it might be more easily transmitted via long-range aerosols [23,24]. In fact, attention was raised to the increased risk of airborne transmission, as well as nosocomial infections with Delta [25], which has inclusively led to vast nosocomial outbreaks even among vaccinated individuals [26,27,28].
Considering the increased number of COVID-19 hospital admissions fueled by the spread of the Delta variant, with Spain showing the highest COVID-19 rates in mainland Europe by July 2021 [29], the aim of this study was to assess SARS-CoV-2 environmental contamination (both air and surfaces) in different areas of a University Hospital in the region of Castile-León, Spain, during the peak of the 5th wave of COVID-19 in the country (July 2021), caused by the Delta variant.

2. Materials and Methods

2.1. Sampling Sites

Environmental sampling took place in a Hospital in Castile-Leon, northern Spain, between 27 and 29 July 2021. Air (n = 21) and surface (n = 40) samples were collected from the following areas of the hospital: microbiology laboratory, emergency department, COVID-19 patients’ triage, COVID-19 patients’ triage waiting room, COVID-19 observation wards, non-COVID-19 intensive care unit (ICU), COVID-19 ICU, COVID-19 ICU’s pharmacy, internal medicine nurses’ room (non-COVID area), corridor of internal medicine department (non-COVID area), internal medicine’s doctor’s room (COVID-19 area), internal medicine department’s corridor (COVID-19 area), internal medicine’s nurses’ room (COVID-19 area), internal medicine’s waiting room, internal medicine oncology department’s corridor, internal medicine’s oncology department’s waiting room. Further details about each sampling site are summarized in Table 1 and Table 2.

2.2. Collection of Air and Surface Samples

Air samples were collected using one Coriolis® µ (Bertin Instruments, Montigny-le-Bretonneux, France) cyclonic microbial air sampler. One air sampling was collected from each of the above-mentioned areas of the Hospital for 10 min each with an airflow rate of 300 L/min (total of 3 m3). In every sampling location, the sampler was placed in the middle of the room or as close to the middle of the room as possible, with their air inlets at approximately 1.3 m height, which is approximately the distance from the ground to the nose of a seated person. The samples were collected on wet medium, with 6 mL of sterile phosphate buffered saline (PBS) added to the collection cones before sampling. After every sample, the cleaning and decontamination of the sampler were performed according to the manufacturer’s instructions. Briefly, a wipe dampened with a surfactant–water solution was used to clean the external parts of the air sampler. After that, the sampler was wiped down with a soft cloth to remove any excess product.
Surface samples were also collected from each of the above-mentioned areas of the hospital on 10 cm × 10 cm surface (100 cm2) using sterile flocked plastic swabs previously wetted on PBS and immediately placed in vials containing 4 mL of PBS. The surfaces sampled in every room were the ones pointed by the healthcare workers present in every sampled room as frequently touched surfaces.
The researchers responsible for performing the sampling were wearing KN95 masks and gloves at all times, with masks changed every 4 h, gloves changed after handling each sample, and hand washing between handling each sample.
All samples were stored at 4 °C until transportation to the laboratory facilities and were processed within 24 h.

2.3. RNA Extraction and Detection of SARS-CoV-2

RNA extraction was performed using the NucleoSpin® mini kit for viral RNA/DNA purification (Macherey-Nagel, Düren, Germany) according to the manufacturer’s instructions. To determine the extraction efficiency of the samples, The Mengovirus Extraction Control kit KMG (BioMérieux, Marcyl’Etoile, France) was used according to the manufacturer’s instructions. The nucleic acids extracted from the air and swab samples were tested for SARS-CoV-2 using the TaqPath™ 1-Step RT-qPCR Master Mix (ThermoFisher catalog #A15300). The reaction aimed at two viral gene targets (N1, N2) using viral target-specific primers and Taqman probe technology (IDT Technologies, San Diego, CA, USA) according to a previously described protocol [30,31]. For the QuantStudio™ 1 Real-Time PCR System (ThermoFisher catalog #A40427), the QuantStudio™ Design & Analysis Software v1.5.1 was used to control the runs and remotely analyze the data. Each RT-qPCR run included triplicates for each sample, including negative and positive controls, and a negative control of RNA isolation.
Reactions were set up and run with initial conditions of 15 min at 50 °C and 2 min at 95 °C, then 45 cycles of 95 °C for 3 s and 55 °C for 30 s [30,31]. A standard curve was constructed using the ssDNA targets for both N1 and N2 regions in a ten-fold serial dilution mixture starting at 2 × 105 copies/µL to quantify the number of viral gene copies present in each sample from the measured CT values. The limit of detection (LOD) was 10 copies/µL for N1 and 10 copies/µL for N2. Air sample results are expressed in copies/m3, and surface sample results in copies/cm2.

3. Results

The negative controls of isolation and non-template controls that were added to monitor each sampling run were negative, discarding the possibility of contamination during RNA extraction and during the preparation of the plate for RT-qPCR. The Ct values of the mengovirus RNA varied only slightly between samples, confirming that the RNA isolation was almost optimal and that there was little or no inhibition in the RT-qPCR. The positive controls added to the RT-qPCR reactions for each gene behaved as expected with very low inter-reaction variation.
Of the 21 air samples collected in 16 different areas of the hospital, only 1 was positive for SARS-CoV-2 RNA, namely a sample from the emergency’s waiting room, with an average copy number of 8.30 gene copies/μL.
Of the 40 surface samples collected, 2 were positive for SARS-CoV-2 RNA, both from the microbiology laboratory, with an average copy number of 3.65 and 3.57 gene copies/μL, respectively. One of the samples was from the buttons of the laminar flow cabinet (sample handling room) and the other from the handle of a freezer containing COVID-19 samples (See Table 3 below).

4. Discussion

In Spain, the fifth wave of COVID-19 caused by the Delta variant reached its peak by the end of July 2021 [32]. Because the Delta variant is more contagious and its reproductive number higher than the previous VOCs [33], attention was brought to an increased risk in airborne transmission, as well as nosocomial infections [25].
Indeed, a nosocomial cluster of COVID-19 caused by the Delta variant was reported in a major acute care hospital in Singapore [28]. This cluster comprised 47 cases and happened despite enhancement of infection control measures for COVID-19 undertaken by this hospital. Turbulent air flow and swabs from air exhaust filters showed to be positive for SARS-CoV-2. Another nosocomial outbreak caused by the Delta variant in a highly vaccinated population was described in Israel in 2021 [26]. This cluster had 42 infected patients, staff, and family members, of which 39 were fully vaccinated. Moreover, all cases were linked and traced to one patient, with several transmissions having occurred between people who were wearing face masks. Similarly, a study in Finland has reported an outbreak caused by the SARS-CoV-2 Delta variant in a secondary care hospital, which resulted in 58 infections, including 18 deaths in patients and 45 infections among healthcare staff [34]. This outbreak occurred despite the use of personal protective equipment (PPE), a high vaccination coverage, and universal masking by the healthcare staff.
These studies reflect the higher transmissibility of the Delta variant, which in turn can lead to an increase in the risk for airborne transmission and nosocomial infections even when appropriate PPE are being used, and among fully vaccinated individuals as well. With that in mind, it was our goal to investigate the presence of SARS-CoV-2 in indoor air and surfaces of a major hospital in the region of Castile-León in Spain, in order to assess if hospital measures to reduce nosocomial infection in place were efficient at preventing infection with the high transmissible Delta variant. During the collection period, the cumulative incidence rate (IR) and the cumulative mortality rate (MR) at 14 days at the national level was ~800 cases per 100,000 habitants and ~150 deaths per 100,000 habitants, respectively [35].
We found in our study three samples positive for SARS-CoV-2 RNA, namely one air sample from the emergency’s waiting room and two surface samples from the hospital’s microbiology laboratory, where COVID-19 nasopharyngeal swab samples from COVID-19 suspected patients were processed and analyzed. The low number of positive samples found are not surprising, though. Unlike the pre-vaccination period of the COVID-19 pandemic, the number of hospitalized people and people admitted to the ICU greatly decreased due to the high COVID-19 vaccination rate in Spain by 29 July 2021, with 56% of the population with at least one dose of the vaccine at the time this experiment ended [36]. The benefits of a high vaccination coverage can be seen in the evolution of cumulative hospitalization rates and cumulative ICU admissions at 7 days per 100,000 habitants in Spain during this period (end of July 2021), figured at ~10 cases per 100,000 habitants, in contrast to January and February 2021, when the number of vaccinated people was still low (2.7% of population with at least one dose of the vaccine), and it figured at ~40 cases per 100,000 habitants [35]. Taking that into consideration, a great degree of air and environmental contamination with SARS-CoV-2 was not expected.
Of note, data on SARS-CoV-2 testing of suspected COVID-19 patients, as well as sequencing of positive samples, were provided by the Hospital. During the week this experiment took place, 4734 people suspected of being infected with SARS-CoV-2 have been tested for COVID-19 in this hospital, of which 725 tested positive (15.3%). Of the 725 positive patients, 639 were from primary care, and 86 came from the clinical hospital (9 admitted, 17 from the polyclinics and 60 from emergencies). Of these 725 positive cases 547 cases (75.4%) were from the delta variant (absence of 69–70 deletion, and presence of N501Y mutation), 160 cases (22.1%) were from the alpha variant (presence of deletion 69–70, and presence of N501Y mutation), and 18 cases (2.5%) were from other strains of the virus which are neither delta nor alpha. Out of these 725 positive samples, a random sample constituting of 55 positive patients, was further analyzed through whole genome sequencing (NextSeq Illumina). Table 4 shows the information about the variants identified through sequencing of samples from SARS-CoV-2 positive patients at the hospital during the week the experiment took place.
When taking a closer look at these results, it is important to highlight the fact that, in the microbiology laboratory of the hospital, there were two surface samples positive for SARS-CoV-2 RNA, with no positive air sample in this environment. As such, the positive surface samples are likely the result of deposition of airborne particles or even contamination of surfaces by clinical samples since it is in that area of the hospital that SARS-CoV-2 molecular diagnosis is performed using the same combinations of primers/probes as we used in this study.
When it comes to the positive air sample from the emergency’s waiting room, it should be highlighted that during the whole duration of sampling this room was empty, suggesting that the positive air sample is likely the result of suspended SARS-CoV-2 particles in the air emitted by patients who have been in the room previously to our air sampling.
It is worth to mention that the same air sampling methodology has been previously used in both healthcare and non-healthcare facilities and successfully detected the presence of SARS-CoV-2 RNA in indoor and outdoor air samples [37,38], including negative pressure rooms [37], although with a low rate of positivity just as in this study. Nonetheless, the absence of detectable SARS-CoV-2 in air samples might be due to many factors, among them (1) infected patients were not present in the sampled environments long enough to shed a measurable amount of virus; (2) patients in this hospital were all complying with preventive guidelines and were wearing high quality masks such as KN95 and PFF2 masks; (3) the specific transmission prevention rules in place at this hospital such as a “clean area” where patients who have tested negative for COVID-19 through RT-PCR were taken to, which was completely isolated from the “contaminated area” where patients with RT-PCR confirmed COVID-19 were taken to, control measures over capacity and attendance per day in order to reduce the circulation of people in the hospital, as well the use of properly pressurized rooms (positive or negative) according to the type of patients present in each area/room of the hospital.
Negative pressure rooms incorporate a ventilation system designed so that air flows from the corridor into the negative pressure room, with COVID-19 patients usually kept in isolation wards with this type of pressurization in order to prevent the contaminated air to escape from these areas to other parts of the hospital [39]. Therefore, detection of SARS-CoV-2 in the air of negative pressure rooms with COVID-19 patients is to be expected.
Other alternative approaches to predict the dispersion of SARS-CoV-2 in the air in different environments could be computational fluid dynamics stimulation models [40,41], risk assessment analysis [42,43,44], and modelling of aerosol transport and virus exposure with numerical simulations [45]. More conclusions could be drawn if other similar studies are performed during the circulation of other variants of concern, so a comparison between patterns of SARS-CoV-2 distribution in these environments could be compared in different waves caused by different variants.
Nonetheless, it has been demonstrated that expiratory aerosol particles can escape from surgical masks due to imperfect sealing [46,47], making surgical masks less efficient when it comes to preventing transmission of more transmissible variants such as the Delta variant, and, more recently, the Omicron (B.1.1.529) and all its sub-lineages [48,49,50,51]. That coupled to the fact that current health policies in many countries are still dealing with the consequences of taking too long to acknowledge airborne transmission of SARS-CoV-2, make the surge of these new more transmissible VOCs lead to much higher quantum production rates, suggesting that the pandemic is now driven mainly by the airborne route of transmission [52]. Taking all that into consideration, and considering that SARS-CoV-2 has now become part of our lives and from now on we will continue to co-exist with it [53], public health policies should pay close attention to current infection prevention guidelines and determine the necessary updates in said guidelines in order to minimize airborne transmission of new VOCs [53], especially when it comes to wearing masks in closed spaces and healthcare settings. In this regard, the recommendation for use of more efficient masks (e.g., KN95 and FFP2 masks) should be maintained, as this is one of the most efficient ways of preventing widespread transmission of SARS-CoV-2 through the airborne route in all environments.

5. Conclusions

Considering that COVID-19 is an airborne disease, an in light of the surge of new variants highly transmissible and less susceptible to vaccines, as well as the current lift of restrictions worldwide, it is essential that the prevention guidelines for COVID-19 maintain the recommendation for the use of more efficient masks such as KN95 or FFP2 models in healthcare settings, as these have been proven to be more effective than surgical and cloth masks when it comes to these more transmissible variants. The results may be relevant for risk assessment of nosocomial infection within healthcare facilities, thus helping prevent and minimize healthcare staff’s exposure to SARS-CoV-2, reinforcing the importance of always wearing appropriate and well-fit masks at all times and proper PPE when in contact with infected patients.

Author Contributions

Conceptualization, P.G.d.S. and J.R.M.; methodology P.G.d.S., J.R.M., S.I.V.S., J.G., A.T.F., E.R. and P.G.E.; investigation, P.G.d.S., J.G. and A.T.F.; resources, J.R.M., S.I.V.S. and P.G.E.; writing—original draft preparation, P.G.d.S.; writing—review and editing, P.G.d.S., J.R.M., S.I.V.S., M.S.J.N., J.G., A.T.F., E.R., P.G.E., I.D., A.O.D., S.G.P., G.A.M.R. and C.J.D.G.; supervision, J.R.M., S.I.V.S. and P.G.E.; All authors have read and agreed to the published version of the manuscript.

Funding

This work was supported by national funds, through Fundação para a Ciência e Tecnologia (FCT, Portuguese Foundation for Science and Technology), under projects UIDB/04750/2020 and LA/P/0064/2020, and by LA/P/0045/2020 (ALiCE) and UIDB/00511/2020-UIDP/00511/2020 (LEPABE) funded by national funds through FCT/MCTES (PIDDAC). This work also had financial support from the Regional Government of Castilla y León and the FEDER program (projects CLU 2017-09, UIC315 and VA266P20) and by the Regional Government of Castilla y León and the FEDER program (projects CLU 2017-09, CL-EI-2021-07, UIC315 and VA266P20). This work was also supported by the AIRCOVID initiative and is financed by the EEA Grants Bilateral Relations Fund through the Agreement on the European Economic Area (EEE), Iceland, Liechtenstein and Norway, which are partners in the internal market with the States-Members of the European Union. As a way of promoting a continuous and balanced strengthening of economic and trade relations, the parties to the EEA Agreement established a multi-annual Financial Mechanism, known as EEA Grants. The EEA Grants aim to reduce social and economic disparities in Europe and strengthen bilateral relations between these three countries and the beneficiary countries. For the period 2014–2021, a total contribution of EUR 2.8 billion has been agreed to 15 beneficiary countries. Portugal will benefit from an allocation of EUR 102.7 million. Learn more at eeagrants.gov.pt (accessed on 12 January 2023).

Data Availability Statement

The data presented in this study are available on request from the corresponding author.

Acknowledgments

Priscilla Gomes da Silva thanks the Portuguese Foundation for Science and Technology—FCT for the financial support of her Ph.D. work (2020.07806.BD, CRM: 0026504) contract through the DOCTORATES 4 COVID-19 program.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. WHO. Transmission of SARS-CoV-2: Implications for Infection Prevention Precautions. Available online: https://www.who.int/news-room/commentaries/detail/transmission-of-sars-cov-2-implications-for-infection-prevention-precautions (accessed on 28 September 2020).
  2. Ma, Q.X.; Shan, H.; Zhang, H.L.; Li, G.M.; Yang, R.M.; Chen, J.M. Potential Utilities of Mask-Wearing and Instant Hand Hygiene for Fighting SARS-CoV-2. J. Med. Virol. 2020, 92, 1567–1571. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  3. Alzyood, M.; Jackson, D.; Aveyard, H.; Brooke, J. COVID-19 Reinforces the Importance of Handwashing. J. Clin. Nurs. 2020, 29, 2760–2761. [Google Scholar] [CrossRef] [PubMed]
  4. Moosa, I.A. The Effectiveness of Social Distancing in Containing Covid-19. Appl. Econ. 2020, 52, 6292–6305. [Google Scholar] [CrossRef]
  5. Asadi, S.; Cappa, C.D.; Barreda, S.; Wexler, A.S.; Bouvier, N.M.; Ristenpart, W.D. Efficacy of Masks and Face Coverings in Controlling Outward Aerosol Particle Emission from Expiratory Activities. Sci. Rep. 2020, 10, 15665. [Google Scholar] [CrossRef] [PubMed]
  6. Morawska, L.; Milton, D.K. It Is Time to Address Airborne Transmission of COVID-19. Clin. Infect. Dis. 2020, 71, 2311–2313. [Google Scholar] [CrossRef]
  7. Murgolo, N.; Therien, A.G.; Howell, B.; Klein, D.; Koeplinger, K.; Lieberman, L.A.; Adam, G.C.; Flynn, J.; McKenna, P.; Swaminathan, G.; et al. SARS-CoV-2 Tropism, Entry, Replication, and Propagation: Considerations for Drug Discovery and Development. PLoS Pathog. 2021, 17, e1009225. [Google Scholar] [CrossRef]
  8. Romano-Bertrand, S.; Carré, Y.; Aho Glélé, L.S.; Lepelletier, D. How to Address SARS-CoV-2 Airborne Transmission to Ensure Effective Protection of Healthcare Workers? A Review of the Literature. Infect. Dis. Now 2021, 51, 410–417. [Google Scholar] [CrossRef]
  9. Lu, R.; Zhao, X.; Li, J.; Niu, P.; Yang, B.; Wu, H.; Wang, W.; Song, H.; Huang, B.; Zhu, N.; et al. Genomic Characterisation and Epidemiology of 2019 Novel Coronavirus: Implications for Virus Origins and Receptor Binding. Lancet 2020, 395, 565–574. [Google Scholar] [CrossRef] [Green Version]
  10. Li, Y.; Huang, X.; Yu, I.T.S.; Wong, T.W.; Qian, H. Role of Air Distribution in SARS Transmission during the Largest Nosocomial Outbreak in Hong Kong. Indoor Air 2005, 15, 83–95. [Google Scholar] [CrossRef]
  11. Xiao, S.; Li, Y.; Wong, T.-w.; Hui, D.S.C. Role of Fomites in SARS Transmission during the Largest Hospital Outbreak in Hong Kong. PLoS ONE 2017, 12, e0181558. [Google Scholar] [CrossRef]
  12. Yu, I.T.S.; Wong, T.W.; Chiu, Y.L.; Lee, N.; Li, Y. Temporal-Spatial Analysis of Severe Acute Respiratory Syndrome among Hospital Inpatients. Clin. Infect. Dis. 2005, 40, 1237–1243. [Google Scholar] [CrossRef] [Green Version]
  13. Booth, T.F.; Kournikakis, B.; Bastien, N.; Ho, J.; Kobasa, D.; Stadnyk, L.; Li, Y.; Spence, M.; Paton, S.; Henry, B.; et al. Detection of Airborne Severe Acute Respiratory Syndrome (SARS) Coronavirus and Environmental Contamination in SARS Outbreak Units. J. Infect. Dis. 2005, 191, 1472–1477. [Google Scholar] [CrossRef]
  14. Olsen, S.J.; Chang, H.L.; Cheung, T.Y.Y.; Tang, A.F.Y.; Fisk, T.L.; Ooi, S.P.L.; Kuo, H.W.; Jiang, D.D.S.; Chen, K.T.; Lando, J.; et al. Transmission of the Severe Acute Respiratory Syndrome on Aircraft. N. Engl. J. Med. 2003, 349, 2416–2422. [Google Scholar] [CrossRef]
  15. Centers for Disease Control and Prevention (CDC). SARS-CoV-2 Transmission. Available online: https://www.cdc.gov/coronavirus/2019-ncov/science/science-briefs/sars-cov-2-transmission.html#print (accessed on 30 April 2022).
  16. WHO. Coronavirus Disease (COVID-19): How Is It Transmitted? Available online: https://www.who.int/news-room/q-a-detail/coronavirus-disease-covid-19-how-is-it-transmitted (accessed on 16 August 2021).
  17. World Health Organization (WHO). Tracking SARS-CoV-2 Variants. Available online: https://www.who.int/en/activities/tracking-SARS-CoV-2-variants (accessed on 2 May 2022).
  18. Yu, F.; Lau, L.-T.; Fok, M.; Lau, J.Y.-N.; Zhang, K. COVID-19 Delta Variants—Current Status and Implications as of August 2021. Precis. Clin. Med. 2021, 4, 287–292. [Google Scholar] [CrossRef]
  19. Rosham, A.; Biswas, R. Global COVID-19 Cases Hit 250 Million, Eastern Europe Infections at Record Levels. Available online: https://www.reuters.com/business/healthcare-pharmaceuticals/global-covid-19-cases-near-250-million-delta-surge-eases-2021-11-07/ (accessed on 2 May 2022).
  20. Tian, D.; Sun, Y.; Zhou, J.; Ye, Q. The Global Epidemic of the SARS-CoV-2 Delta Variant, Key Spike Mutations and Immune Escape. Front. Immunol. 2021, 12, 751778. [Google Scholar] [CrossRef]
  21. Despres, H.W.; Mills, M.G.; Shirley, D.J.; Schmidt, M.M.; Huang, M.-L.; Jerome, K.R.; Greninger, A.L.; Bruce, E.A. Quantitative Measurement of Infectious Virus in SARS-CoV-2 Alpha, Delta and Epsilon Variants Reveals Higher Infectivity (Viral Titer:RNA Ratio) in Clinical Samples Containing the Delta and Epsilon Variants. medRxiv, 2021; preprint. [Google Scholar]
  22. Callaway, E. Delta Coronavirus Brace for Impact. Nature 2021, 595, 17–18. [Google Scholar] [CrossRef]
  23. Schuit, M.; Biryukov, J.; Beck, K.; Yolitz, J.; Bohannon, J.; Weaver, W.; Miller, D.; Holland, B.; Krause, M.; Freeburger, D.; et al. The Stability of an Isolate of the SARS-CoV-2 B.1.1.7 Lineage in Aerosols Is Similar to 3 Earlier Isolates. J. Infect. Dis. 2021, 224, 1641–1648. [Google Scholar] [CrossRef]
  24. Meister, T.L.; Fortmann, J.; Todt, D.; Heinen, N.; Ludwig, A.; Brüggemann, Y.; Elsner, C.; Dittmer, U.; Steinmann, J.; Pfaender, S.; et al. Comparable Environmental Stability and Disinfection Profiles of the Currently Circulating SARS-CoV-2 Variants of Concern B.1.1.7 and B.1.351. J. Infect. Dis. 2021, 224, 420–424. [Google Scholar] [CrossRef]
  25. Reardon, S. How the Delta Variant Achieves Its Ultrafast Spread. Available online: https://www.nature.com/articles/d41586-021-01986-w (accessed on 20 May 2022).
  26. Shitrit, P.; Zuckerman, N.S.; Mor, O.; Gottesman, B.S.; Chowers, M. Nosocomial Outbreak Caused by the SARS-CoV-2 Delta Variant in a Highly Vaccinated Population, Israel, July 2021. Eurosurveillance 2021, 26, 2100822. [Google Scholar] [CrossRef]
  27. Jung, J.; Lee, J.; Park, H.; Lim, Y.-J.; Kim, E.O.; Park, M.-S.; Kim, S.-H. Nosocomial Outbreak by Delta Variant From a Fully Vaccinated Patient. J. Korean Med. Sci. 2022, 37, e133. [Google Scholar] [CrossRef]
  28. Lim, W.Y.; Tan, G.S.E.; Htun, H.L.; Phua, H.P.; Kyaw, W.M.; Guo, H.; Cui, L.; Mak, T.M.; Poh, B.F.; Wong, J.C.C.; et al. First Nosocomial Cluster of COVID-19 Due to the Delta Variant in a Major Acute Care Hospital in Singapore: Investigations and Outbreak Response. J. Hosp. Infect. 2022, 122, 27–34. [Google Scholar] [CrossRef] [PubMed]
  29. Dombey, D.; Burn-Murdoch, J.; Wise, P. Delta Variant Drives Spain’s COVID-19 Rate to Highest in Mainland Europe. Available online: https://www.ft.com/content/06334a7b-30cc-40bf-942b-e3bcd2efb305 (accessed on 1 December 2022).
  30. CDC. CDC 2019-Novel Coronavirus (2019-NCoV) Real-Time RT-PCR Diagnostic Panel. Available online: https://www.fda.gov/media/134922/download (accessed on 30 April 2022).
  31. Gonçalves, J.; Torres-Franco, A.F.; Gomes da Silva, P.; Rodriguéz, E.; Díaz, I.; González Pena, M.J.; Mesquita, J.R.; Munoz, R.; García-Encina, P.A. Exposure Assessment of SARS-CoV-2 and Nov GII/GII in Aerosols Generated by a Municipal Wastewater Treatment Plant. SSRN, 2022; preprint. [Google Scholar] [CrossRef]
  32. McMurtry, A. Spain’s 5th COVID-19 Wave Takes Toll on Hospitals, Tourism. Available online: https://www.aa.com.tr/en/europe/spain-s-5th-covid-19-wave-takes-toll-on-hospitals-tourism/2316038 (accessed on 2 May 2022).
  33. Liu, Y.; Rocklöv, J. The Reproductive Number of the Delta Variant of SARS-CoV-2 Is Far Higher Compared to the Ancestral SARS-CoV-2 Virus. J. Travel Med. 2021, 28, taab124. [Google Scholar] [CrossRef] [PubMed]
  34. Hetemäki, I.; Kääriäinen, S.; Alho, P.; Mikkola, J.; Savolainen-Kopra, C.; Ikonen, N.; Nohynek, H.; Lyytikäinen, O. An Outbreak Caused by the SARS-CoV-2 Delta Variant (B.1.617.2) in a Secondary Care Hospital in Finland, May 2021. Eurosurveillance 2021, 26, 2100636. [Google Scholar] [CrossRef] [PubMed]
  35. Instituto de Salud Carlos III. Red Nacional de Vigilancia Epidemiológica Informe No 89. Situación de COVID-19 En España. Available online: https://www.isciii.es/QueHacemos/Servicios/VigilanciaSaludPublicaRENAVE/EnfermedadesTransmisibles/Documents/GRIPE/Informes%20semanales/Temporada_2020-21/Informe%20n%C2%BA%2089%20Situaci%C3%B3n%20de%20COVID-19%20en%20Espa%C3%B1a%20a%2028%20de%20julio%20de%202021.pdf (accessed on 15 November 2022).
  36. Junta de Castilla y León. Situación Epidemiológica del Coronavirus (COVID-19) En Castilla y León. Available online: https://analisis.datosabiertos.jcyl.es/pages/coronavirus/?seccion=vacunaciones-suministros (accessed on 12 January 2023).
  37. da Silva, P.G.; Gonçalves, J.; Lopes, A.I.B.; Esteves, N.A.; Bamba, G.E.E.; Nascimento, M.S.J.; Branco, P.T.B.S.; Soares, R.R.G.; Sousa, S.I.V.; Mesquita, J.R. Evidence of Air and Surface Contamination with SARS-CoV-2 in a Major Hospital in Portugal. Int. J. Environ. Res. Public Health 2022, 19, 525. [Google Scholar] [CrossRef] [PubMed]
  38. da Silva, P.G.; Gonçalves, J.; Nascimento, M.S.J.; Sousa, S.I.V.; Mesquita, J.R. Detection of SARS-CoV-2 in the Indoor and Outdoor Areas of Urban Public Transport Systems of Three Major Cities of Portugal in 2021. Int. J. Environ. Res. Public Health 2022, 19, 5955. [Google Scholar] [CrossRef]
  39. Al-Benna, S. Negative Pressure Rooms and COVID-19. J. Perioper. Pract. 2021, 31, 18–23. [Google Scholar] [CrossRef]
  40. Tan, H.; Wong, K.Y.; Dzarfan Othman, M.H.; Kek, H.Y.; Tey, W.Y.; Nyakuma, B.B.; Mong, G.R.; Kuan, G.; Ho, W.S.; Kang, H.S.; et al. Controlling Infectious Airborne Particle Dispersion during Surgical Procedures: Why Mobile Air Supply Units Matter? Build. Environ. 2022, 223, 109489. [Google Scholar] [CrossRef]
  41. Li, Y.; Qian, H.; Hang, J.; Chen, X.; Cheng, P.; Ling, H.; Wang, S.; Liang, P.; Li, J.; Xiao, S.; et al. Probable Airborne Transmission of SARS-CoV-2 in a Poorly Ventilated Restaurant. Build. Environ. 2021, 196, 107788. [Google Scholar] [CrossRef]
  42. Ali, S.; Noreen, S.; Farooq, I.; Bugshan, A.; Vohra, F. Risk Assessment of Healthcare Workers at the Frontline against COVID-19. Pak. J. Med. Sci. 2020, 36, S99–S103. [Google Scholar] [CrossRef]
  43. Zhang, X.; Ji, Z.; Yue, Y.; Liu, H.; Wang, J. Infection Risk Assessment of COVID-19 through Aerosol Transmission: A Case Study of South China Seafood Market. Environ. Sci. Technol. 2021, 55, 4123–4133. [Google Scholar] [CrossRef]
  44. Guo, W.; Fu, Y.; Jia, R.; Guo, Z.; Su, C.; Li, J.; Zhao, X.; Jin, Y.; Li, P.; Fan, J.; et al. Visualization of the Infection Risk Assessment of SARS-CoV-2 through Aerosol and Surface Transmission in a Negative-Pressure Ward. Environ. Int. 2022, 162, 107153. [Google Scholar] [CrossRef]
  45. Vuorinen, V.; Aarnio, M.; Alava, M.; Alopaeus, V.; Atanasova, N.; Auvinen, M.; Balasubramanian, N.; Bordbar, H.; Erästö, P.; Grande, R.; et al. Modelling Aerosol Transport and Virus Exposure with Numerical Simulations in Relation to SARS-CoV-2 Transmission by Inhalation Indoors. Saf. Sci. 2020, 130, 104866. [Google Scholar] [CrossRef]
  46. Cappa, C.D.; Asadi, S.; Barreda, S.; Wexler, A.S.; Bouvier, N.M.; Ristenpart, W.D. Expiratory Aerosol Particle Escape from Surgical Masks Due to Imperfect Sealing. Sci. Rep. 2021, 11, 12110. [Google Scholar] [CrossRef]
  47. Wang, Y.; Deng, Z.; Shi, D. How Effective Is a Mask in Preventing COVID-19 Infection? Med. Devices Sens. 2021, 4, e10163. [Google Scholar] [CrossRef]
  48. Davies, N.G.; Abbott, S.; Barnard, R.C.; Jarvis, C.I.; Kucharski, A.J.; Munday, J.D.; Pearson, C.A.B.; Russell, T.W.; Tully, D.C.; Washburne, A.D.; et al. Estimated Transmissibility and Impact of SARS-CoV-2 Lineage B.1.1.7 in England. Science 2021, 372, eabg3055. [Google Scholar] [CrossRef]
  49. Fan, Y.; Li, X.; Zhang, L.; Wan, S.; Zhang, L.; Zhou, F. SARS-CoV-2 Omicron Variant: Recent Progress and Future Perspectives. Signal Transduct. Target. Ther. 2022, 7, 141. [Google Scholar] [CrossRef]
  50. Earnest, R.; Uddin, R.; Matluk, N.; Renzette, N.; Turbett, S.E.; Siddle, K.J.; Loreth, C.; Adams, G.; Tomkins-Tinch, C.H.; Petrone, M.E.; et al. Comparative Transmissibility of SARS-CoV-2 Variants Delta and Alpha in New England, USA. Cell Rep. Med. 2022, 3, 100583. [Google Scholar] [CrossRef]
  51. Duong, B.V.; Larpruenrudee, P.; Fang, T.; Hossain, S.I.; Saha, S.C.; Gu, Y.; Islam, M.S. Is the SARS CoV-2 Omicron Variant Deadlier and More Transmissible Than Delta Variant? Int. J. Environ. Res. Public Health 2022, 19, 4586. [Google Scholar] [CrossRef]
  52. Rowe, B.R.; Canosa, A.; Meslem, A.; Rowe, F. Increased Airborne Transmission of COVID-19 with New Variants, Implications for Health Policies. Build. Environ. 2022, 219, 109132. [Google Scholar] [CrossRef]
  53. Cirrincione, L.; Plescia, F.; Ledda, C.; Rapisarda, V.; Martorana, D.; Lacca, G.; Argo, A.; Zerbo, S.; Vitale, E.; Vinnikov, D.; et al. COVID-19 Pandemic: New Prevention and Protection Measures. Sustainability 2022, 14, 4766. [Google Scholar] [CrossRef]
Table 1. Details from air samples locations.
Table 1. Details from air samples locations.
Air SamplerSample LocationFunction of the AreaHospital Area
Coriolis μEntranceRoom where the Hospital main entrance is locatedMicrobiology diagnostics
Sample handling roomRoom where clinical samples from patients are handled for molecular testingMicrobiology diagnostics
Extraction roomRoom where DNA/RNA extraction of clinical samples to be tested through PCR is performedMicrobiology diagnostics
Waiting room (clean area)Waiting room for patients that have tested negative for COVID-19Emergency Department
ReceptionReception of the emergency department where all patients arriving at the hospital stay in the beginning prior to triageEmergency Department
TriageRoom where patients are brought to be categorized based on their symptomsEmergency Department
COVID-19 waiting roomWaiting room only for patients diagnosed with COVID-19Emergency Department
COVID-19 areaRoom where only COVID-19 patients are being treatedEmergency Department
Corridor between triage and COVID-19 areaCorridor located continuously after the triage room and before the COVID-19 areaEmergency Department
Non-COVID-19 areaRoom where only patients who have tested negative for COVID-19 are being treatedICU
PharmacyRoom where medications are storedICU
COVID-19 areaRoom where only COVID-19 patients are being treatedICU
Non-COVID-19 area: Nurses’ roomDesignated room for nurses where they can go to during their work breaksInternal Medicine
CorridorMain corridor within the Internal MedicineInternal Medicine
Non-COVID-19 practitioners’ roomDesignated room for doctors who are treating patients who are not infected with COVID-19Internal Medicine
COVID-19 practitioners roomDesignated room for doctors who are treating patients who are infected with COVID-19Internal Medicine
10th floor corridorMain corridor of the 10th floor (clean area)Internal Medicine
10th floor nurses roomDesignated room for nurses where they can go to during their work breaksInternal Medicine
8th floor waiting roomWaiting room for Internal Medicine patientsInternal Medicine
6th floor oncology roomWaiting room for oncology patientsInternal Medicine
Corridor of oncology waiting roomCorridor outsider the oncology waiting roomInternal Medicine
Table 2. Details from surface samples collection.
Table 2. Details from surface samples collection.
Sample LocationHospital Area
Sample reception room: tableMicrobiology diagnostics
Reception room: door handleMicrobiology diagnostics
Entrance door: inside handleMicrobiology diagnostics
Sample handling room: keyboardMicrobiology diagnostics
Sample handling room: buttons from laminar flow cabinetMicrobiology diagnostics
Table where samples are placed before openingMicrobiology diagnostics
Touchscreen of MagNA machine (nucleic acid extraction machine) in extraction roomMicrobiology diagnostics
Buttons of KingFisher machine (nucleic acid extraction machine) in extraction roomMicrobiology diagnostics
COVID-19 samples’ freezer: handleMicrobiology diagnostics
Vending machine: buttonEmergency Department
Coffee machine: buttonEmergency Department
Door handle from door leading to non-COVID areaEmergency Department
Door handle from toilet’s door in the non-COVID areaEmergency Department
Wall where patients stay in the non-COVID areaEmergency Department
Table where medication is preparedEmergency Department
Triage: Buttons Spot Vital SignsEmergency Department
PhoneEmergency Department
Door handle to door leading to common roomEmergency Department
Chair in COVID-19 waiting roomEmergency Department
Door handle from the toilet’s door in the COVID-19 areaEmergency Department
Touch screen from vital signs device in the COVID-19 areaEmergency Department
Toilet’s flush button in the COVID-19 areaEmergency Department
Gloves box in the COVID-19 areaEmergency Department
Door handle of staff’s toiletEmergency Department
Toilet’s flush button in staff’s toiletEmergency Department
Staff’s table in the non-COVID-19 areaICU
Computer’s keyboard in the non-COVID-19 areaICU
Phone in the non-COVID areaICU
Pharmacy’s tableICU
Staff’s computer’s keyboard in the COVID-19 areaICU
Phone in the COVID-19 areaICU
Table in the non-medical staff’s room in the COVID-19 areaICU
Microwave’s handle in the non-medical staff room of COVID-19 areaICU
11th floor, nurses room: microwave handleInternal Medicine
11th floor: computer’s keyboard in corridorInternal Medicine
11th floor, medical doctors room: phoneInternal Medicine
10th floor, medical doctors room: phoneInternal Medicine
10th floor: computer’s keyboard corridorInternal Medicine
Microwave handle nurses roomInternal Medicine
8th floor: small table in waiting roomInternal Medicine
Toilet’s flush buttonInternal Medicine
Entrance door’s handleInternal Medicine
6th floor: toilet faucetInternal Medicine
6th floor: toilet flush buttonInternal Medicine
Waiting room: small tableInternal Medicine
5th floor traumatology and orthopedics’ toilet: sink faucetInternal Medicine
5th floor traumatology and orthopedics’ toilet: flush buttonInternal Medicine
5th floor traumatology and orthopedics’: exit door handleInternal Medicine
Table 3. Values of gene copies/L and standard deviation for the positive air and surface samples tested in triplicate for the N1 region.
Table 3. Values of gene copies/L and standard deviation for the positive air and surface samples tested in triplicate for the N1 region.
N1
SampleResult 1 (Copies/μL)Result 2 (Copies/μL)Result 3 (Copies/μL)Average Copies/μLStandard Deviation
Emergency’s waiting room-4.383.928.300.645
Buttons from the laminar flow cabinet (sample handling room)1.961.551.823.650.468
Handle of freezer for COVID-19 samples2.201.37-3.571.167
Table 4. Variants identified through sequencing of samples from SARS-CoV-2 positive patients at the hospital during the week the experiment took place.
Table 4. Variants identified through sequencing of samples from SARS-CoV-2 positive patients at the hospital during the week the experiment took place.
VariantDelta (70.9%)Alpha (21.8%)Beta (3.6%)Lambda (3.6%)
LineageB.1.617.2AY12AY4(B.1.1.7)(B.1.351)(C.37.1)
Number of cases31441222
Total number of cases55
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Gomes da Silva, P.; Gonçalves, J.; Torres Franco, A.; Rodriguez, E.; Diaz, I.; Orduña Domingo, A.; Garcinuño Pérez, S.; March Roselló, G.A.; Dueñas Gutiérrez, C.J.; São José Nascimento, M.; et al. Environmental Dissemination of SARS-CoV-2 in a University Hospital during the COVID-19 5th Wave Delta Variant Peak in Castile-León, Spain. Int. J. Environ. Res. Public Health 2023, 20, 1574. https://doi.org/10.3390/ijerph20021574

AMA Style

Gomes da Silva P, Gonçalves J, Torres Franco A, Rodriguez E, Diaz I, Orduña Domingo A, Garcinuño Pérez S, March Roselló GA, Dueñas Gutiérrez CJ, São José Nascimento M, et al. Environmental Dissemination of SARS-CoV-2 in a University Hospital during the COVID-19 5th Wave Delta Variant Peak in Castile-León, Spain. International Journal of Environmental Research and Public Health. 2023; 20(2):1574. https://doi.org/10.3390/ijerph20021574

Chicago/Turabian Style

Gomes da Silva, Priscilla, José Gonçalves, Andrés Torres Franco, Elisa Rodriguez, Israel Diaz, Antonio Orduña Domingo, Sonsoles Garcinuño Pérez, Gabriel Alberto March Roselló, Carlos Jesús Dueñas Gutiérrez, Maria São José Nascimento, and et al. 2023. "Environmental Dissemination of SARS-CoV-2 in a University Hospital during the COVID-19 5th Wave Delta Variant Peak in Castile-León, Spain" International Journal of Environmental Research and Public Health 20, no. 2: 1574. https://doi.org/10.3390/ijerph20021574

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop