Optimal Parameters of Volt–Var Function in Smart Inverters for Improving System Performance

1
Department of Electrical Engineering, Soongsil University, 369, Sangdo-ro, Dongjak-gu, Seoul 06978, Korea
2
Korea Electric Power Research Institute (KEPRI), Korea Electric Power Company (KEPCO), 105, Munji-ro, Yuseong-gu, Daejeon 34056, Korea
*
Author to whom correspondence should be addressed.
Energies 2020, 13(9), 2294; https://doi.org/10.3390/en13092294
Submission received: 17 February 2020 / Revised: 22 April 2020 / Accepted: 29 April 2020 / Published: 6 May 2020
(This article belongs to the Special Issue Optimal Home Energy and Active Management Strategy in Smart Grids)

Abstract

:
This paper proposes a method to improve the performance of a distribution system by optimizing volt–var function of a smart inverter to alleviate the voltage deviation problem due to distributed generation connection. In order to minimize voltage deviation and line losses which represent the performance of a distribution system, this paper proposes an algorithm that optimally sets the parameters of the volt–var function. In the process of optimizing the parameters of the volt–var function, the algorithm proposed in this paper considers minimizing the contribution of the reactive power in order not to affect the output of the distributed generation. In order to apply to the field, the distribution system in South Korea considering the configuration and operation regulation was selected as a test model for algorithm verification. As a result, the system performance was successfully improved by optimally setting the volt–var function of the smart inverter which is an effective way to solve the over-voltage problem caused by distributed generation connection. This paper verified the proposed method through OpenDSS, a quasi-static time-series simulation, for the test model considering the characteristics of the distribution system in South Korea.

Graphical Abstract

1. Introduction

Distributed generation based on renewable energy sources is increasing all over the world, at the same time, distributed generation, such as photovoltaic (PV), are increasing rapidly in South Korea. According to the South Korean government’s plan, the total capacity of renewable energy sources to be supplied by 2030 will be 58.5 GW [1,2]. In particular, in South Korea, by encouraging the installation of the PV through an incentive program, the number of individual businesses is increasing, hence, connecting PV to the distribution system [3,4,5]. Therefore, distribution system operators (DSOs) need to improve system performance while maintaining the stability of the system even though the level of the PV penetration is increased.
When the PV penetration level of the distribution system increases, the problem of the over-voltage generally occurs before any thermal problem [6,7,8,9]. In order to solve the over-voltage problem, DSOs are considering tap control of main transformer (MTR) [7,8,10,11,12], installation of step voltage regulator (SVR) [7,10,13,14,15,16] and control of the distributed generation such as PV [7,8,17]. However, in South Korea, since tap control of the MTR is the authority of the transmission system operators (TSOs), it is difficult to apply tap control of the MTR as a way to solve the over-voltage problem caused by connecting distributed generation. In addition, even when over-voltage occurs in one of the multiple feeders, it is not suitable for solving the problem. When the SVR is applied, one way to solve the over-voltage problem is to effectively solve the over-voltage problem for each feeder, but the disadvantage is that the cost increase as the number of installation increases depending on the number of feeders. Therefore, the function of controlling the output on the distributed generation in accordance with the distribution system condition is in the spotlight.
As mentioned above, in order to solve problems caused by increased penetration levels of the distributed generation and to improve the system performance, research has been done on the setting of the volt–var function. References [18,19] proposed a method to find optimal volt–var curves for grid-connected rooftop PV using a three-phase optimal power flow. However, these papers have limitations for performance improvement by optimizing only the set points of the volt–var curve. Reference [20] proposed the algorithm for volt–var curve selection with the integration of a high-level penetration of a PV smart inverter. However, it is practically difficult to change the optimal setting of the curve every hour. Reference [21] provided an option to optimize the volt–var and volt–watt function considering PV output and System losses. However, in this reference, reactive power command was fixed and voltage, which is an important factor, was not considered. References [22,23] evaluated the impact of a smart inverter volt–var function on voltage and power quality in electric power distribution system. These references consider many factors that could be considered in the system and classify the PV penetration rate as a scenario. However, there is a lack of explanation for the optimized volt–var curve and weights which significantly affect the results. Reference [24] reduced the energy losses by suggesting the optimal volt–var control method considering PV penetration rate and weather conditions. However, this reference does not consider the voltage factor which is an important factor in the system. Further, there is a realistic problem that it is difficult to update the volt–var control depending on the situation. Reference [25] described the function of a smart invert to improve the distribution system performance such as hosting capacity. However, this reference considered the factor of the system and did not consider the optimization process of the volt–var curves. Reference [26] evaluated the volt–var function and volt–watt function based on PV penetration level and PV curtailment. However, this reference was evaluated using a set-point of volt–var curve. Reference [27] analyzed the system factor according to volt–var function using a multi-objective function. However, the system factors were not considered at the same time by fixing the weight to 1. Further, this method causes a decrease in the PV output by not considering the effect on the active power for reactive power. Reference [28] analyzed the impact of the smart invert setting on the performance of a distribution feeder in the United States. However, this reference does not consider various factors of distribution systems. Further, the improvement of the proposed method was limited due to only using standard settings. References [29,30] analyzed five different inverter control strategies for differing objective functions. Further, these papers analyzed the output reduction effect of the active power due to the reactive power control. However, the improvement effect reached its limit because the inverter function such as volt–var had not been optimized.
This paper contributes the following parts to improve the shortcomings of existing studies.
  • Existing studies have the problem of analyzing only one of various factors such as power quality, losses, energy of the distribution system. So, in the setting process of the volt–var function, various factors such as voltage deviation, system loss and peak of reactive power were considered using a multi-objective function.
  • The objective function was not properly utilized due to the weight that was not appropriate in the previous studies. Therefore, by using weights appropriately, the algorithm proposed in this paper could provide options to DSOs according to the situation of the distribution system.
  • In previous studies, the volt–var function was proposed to update hourly or daily depending on the PV and load pattern. However, this method has encountered difficulties in real industry. To solve this problem, this paper verified the algorithm in a test model based on South Korea distribution system using real PV and load data (one-year).
Section 2.1 describes the test model that considers the characteristics of distribution system in South Korea for algorithm verification. Section 2.2 describes the volt–var function of smart inverter to alleviate the over-voltage due to connecting distributed generation. Section 2.3 describes the parameter optimization algorithm to improve the system performance while alleviating over-voltage problem. Section 3 shows the simulation configuration and results for verifying the proposed algorithm. Section 4 provides discussion about this paper. Section 5 is a conclusion.

2. Analysis Methodology

2.1. Test Model for Effect Verification

Section 2.1 describes the test model for verifying the effectiveness of the proposed algorithm. To consider South Korea’s distribution system, the test model consisted of system configuration, operating regulation and field data. Figure 1 shows the test model considering the characteristics of distribution system in South Korea [7,13,14,15,31]. Table 1 shows the parameters used in the test model. Feeder #1 has a short range with urban, feeder #2 has a medium range and feeder #3 has a long range feeder with rural. The power conditioning system (PCS) capacity for modelling in the PV was set differently from case to case, but this model assumes a 10% margin [29,30,32]. The installation location of the PV was assumed to be the end of the long range feeder (Feeder #3) where the over-voltage problem occurs first before other location [9,33]. The reason for the assuming only one PV is to make it easier to analyze the system performance according to the parameter of the volt–var function.
Figure 2 shows a one-year pattern that normalized the PV output and power usage of the load [34,35]. In the case of the PV output pattern which is South Korea’s Yeong-Am PV data, the output is the highest in May due to the surrounding environment, such as temperature. Regarding the power usage of the load, the power usage is drastically reduced in the spring and autumn due to the holiday season (Korean New Year’s Day, Korean Thanksgiving Day). In addition, power usage increases due to heating and cooling loads in summer and winter.
As mentioned in the introduction, existing studies which are based on the daily pattern data are difficult to apply in the real industry due to the set parameters of the volt–var function.The updating method based on daily mesurements will be applicable when communication performance is solved. In order to solve this problem, this paper proposes an algorithm to optimize the parameter of the volt–var function using a pattern of one year.

2.2. Volt–Var Function of Smart Inverter

Section 2.2 describes the volt–var function of a smart inverter which is a solution to alleviate the over-voltage problem caused by the increase of connecting distributed generation. The volt–var function could help to maintain the power quality of the distribution system by controlling reactive power according to the point of common coupling (PCC) voltage. Figure 3a shows the common volt–var function curve [23,24,28]. The volt–var function is to control the absorption the reactive power if the voltage begins to exceed the upper level. On the contrary, when the voltage begins to fall below the lower level, the reactive power could be injected in the distribution system to help in maintaining the normal voltage. Figure 3b shows the standard default setting of volt–var function [25,33,36]. The standard setting is referred to as “Aggressive”, “Moderate”, or “Mild” depending on the slope. The volt–var function as a standard has a dead-band according to the nominal voltage (except “aggressive”). Except for the dead-band, the region is linearly configured for the absorption or injection of the reactive power to help maintain the PCC voltage. The peak of the reactive power for these curves is affected by the inverter’s capacity and operator’s priority.
Equation (1) shows the reactive power command ( Q s . i ( V ( t ) ) ) of the smart inverter according to the PCC voltage ( V ( t ) ) [24,26]. When the PCC voltage is lower than V v v 1 , the smart inverter contributes to the reactive power ( Q v v 1 ) to rise the PCC voltage. When the PCC voltage is between V v v 1 and V v v 2 , the smart inverter injects the reactive power corresponding to the slope to maintain the normal voltage. When the PCC voltage is between V v v 2 and V v v 3 in the setting curve where the dead-band exists, the smart inverter does not contribute the reactive power to the distribution system. On the contrary, when the PCC voltage rises between V v v 3 and V v v 4 , the smart inverter absorbs the reactive power to help limit the voltage rise. When the voltage rises above V v v 4 , the smart inverter contributes to limit the voltage rise by absorbing the reactive power ( Q v v 4 ).
Q s . i ( V ( t ) ) = Q v v 1 ( V ( t ) V v v 1 ) Q v v 1 V v v 2 V v v 1 ( V ( t ) V v v 2 ) ( V v v 1 < V ( t ) V v v 2 ) 0 ( V v v 2 < V ( t ) V v v 3 ) Q v v 4 V v v 4 V v v 3 ( V ( t ) V v v 3 ) ( V v v 3 < V ( t ) V v v 4 ) Q v v 4 ( V v v 4 < V ( t ) )
Figure 4 shows the limit range of the inverter’s reactive power. The PV system produces the energy depending on the PV panel (nameplate (kW)), irradiation and weather condition. Therefore, for economic reasons, individual business often prefers the PCS size smaller over the PV panel. However, when the reactive power needs to contribute a lot to the distribution system, the active power could be affected, such as limited output [18,23,29,37,38]. For this reason, the contribution of the reactive power should be minimized in order to guarantee the profits of individual businesses.
Figure 5 shows the voltage profile to confirm the improvement effect of the voltage quality when the volt–var function as “moderate” of Figure 3b was applied. The “moderate” setting is the most common of the standard settings. The quasi-static time-series PCC voltage was getting closer to the nominal voltage by applying the volt–var function. In other words, this means that the voltage deviation was reduced and the voltage quality was improved. Further, in terms of the grid code, an increase in voltage margin could be seen as an increase in hosting capacity.

2.3. Optimizing Parameter of Volt–Var Function Using Particle Swarm Optimization

Section 2.3 describes the process of optimizing the parameters of the volt–var function to improve the system performance using particle swarm optimization (PSO). The PSO is a computational method that optimizes the problem by iteratively improving the candidate solution by obtaining a motif from the movement of organisms in a bird flock or fish school. The PSO is very simple and fast because only the optimistic particles in different generations transmit information to other particles. By using PSO, one of the metaheuristics, as an optimization tool, algorithm proposed in this paper set a high iteration to avoid local solutions and reach a global solution. This method could increase the calculation time, but the setting of the smart inverter is not a big problem because it is a planning stage, not a real-time control stage or an operation stage. In addition, by using PSO as an optimization tool of the algorithm, it can be flexibly applied to distribution systems with different configurations. In addition to the PSO, there are optimization methods such as genetic algorithms (GAs), and ant colony algorithms to solve the distribution system problem. However, the performance comparison of the optimization technique is not covered because it is beyond the scope of this paper [13,14,15,31,37,38,39,40,41].
The setting of the volt–var function on the smart inverter affected the system losses and voltage deviation which represent the indicators of the system performance. The line losses are related to revenues from DSOs and customers. The voltage deviation is directly related to the power quality and planning of the system operation. Further, in some cases, as mentioned in Section 2.2, setting the volt–var function has an adverse effect like reducing the output of the PV. However, most PV operators in South Korea are managed by individual businesses. Therefore, since the PV output is directly related to the profit of the individual, it is difficult to mount the control which causes the output reduction in the smart inverter. For these reasons, this paper considered the elements of the multi-objective function to optimize the voltage deviation, the system losses and the peak of the reactive power.
Equation (2) represents the objective function that should be minimized to improve system performance.
M i n O F ( v v n e w ) = M i n t = 1 8760 | δ V i , t ( v v n e w ) | | δ V i , t ( v v c o n ) | ω 1 + | P t ( v v n e w ) | | P t ( v v c o n ) | ω 2 + | Q i ( v v n e w ) | | Q i ( v v c o n ) | ω 3
where,
  • i: Bus with distributed generation
  • t: Time [h]
  • v v n e w : Parameter for newly updated volt–var function ( V v v 1 , V v v 2 , V v v 3 , V v v 4 , Q v v 1 , Q v v 4 )
  • v v c o n : Parameter of conventional volt–var function in Figure 3b (Moderate)
  • ω : Weight for each evaluation index (voltage deviation, line losses, peak of reactive power)
  • V r e f : 22.9 [kV]
  • V i , t : Voltage of the bus (i) at time (t) according to parameters of the volt–var function
  • δ V i , t ( v v ) = V r e f V i , t ( v v ) V r e f : Voltage deviation index of the bus (i) at time (t)
  • P t ( v v ) : System losses at time (t) according to parameters of the volt–var function
  • Q i ( v v ) : Peak of reactive power on smart inverter according to parameters of the volt–var function
Equation (3) represents the fitness value for improving system performance at each simulation iteration period (one year) by using Equation (2) and constraint. Particles (parameter, v v n e w ) with a minimum (optimum) fitness value represent the parameter of the volt–var function that can maximize the system performance.
M i n F ( v v n e w ) = M i n O F ( v v n e w ) + c N c o n s t ω c · P F c
where
  • N c o n s t : Set constraint
  • ω c : Penalty coefficient
  • P F c : Weight for each constraint
The following list describes the constraints that must be considered when setting the parameters of the volt–var function. In this paper, the penalty coefficient ( 10 × 10 20 ) is set to a very high value in order to find an optimized parameter that satisfies the constraints.
  • Voltage constraints
    Table 2 shows the range in which the voltage of the distribution system regulated in South Korea should be maintained. Therefore, the voltage of the distribution system must be kept within the range as shown in Equation (4) during processing optimization of setting parameter [42].
    V i m i n V i , t V i m a x
    where, V i m i n = 0 . 908 [ p . u . ] , V i m a x = 1 . 039 [ p . u . ]
  • Parameter Setting Range of Volt–Var Function
    In the process of setting optimal parameters, the parameter range is set as Equation (5) to enable the smart inverter to operate properly. The reason why V v v 3 is set equal to or greater than V v v 2 is to consider a dead-band through the optimization process. The proposed algorithm in this paper is similar to the existing volt–var function curve through these constraints, but could find the optimal parameters to improve the system performance.
    V v v 1 < V v v 2 V v v 3 < V v v 4 0 | Q v v 1 | 1 , 0 | Q v v 4 1
Figure 6 shows a flowchart that set the optimal parameters of the volt–var function for improving system performance using PSO. The minimum fitness value of Equation (3), which takes into account some constraints, could be calculated by iterating until the termination condition is satisfied.

3. Simulation for Effect Verification

Section 3 verified the performance of the volt–var parameter optimization algorithm for the test model considering the distribution system characteristics of South Korea through simulation. To verify the contribution of this paper, the simulation tool was utilized by OpenDSS which is a quasi-static time-series simulation.

3.1. Simulation Configuration

Section 3.1 shows the simulation configuration for algorithm verification proposed in this paper. Table 3 shows the cases for comparison between the conventional method and proposed method to confirm the contribution of the proposed algorithm.
In order to confirm the effect of applying the volt–var function, the case where the volt–var function is not applied is named without a volt–var function (W/O V-V). Case A represents the default setting (“moderate”) by a standard volt–var function. Case B applies the same weight to each system performance and case C applies the most weight ( ω 1 ) to prioritize the reduction of the voltage deviation. Case D applies the most weight ( ω 2 ) to prioritize the improvement of the system losses. Case E sets high weight ( ω 3 ) to prioritize the reduction of the peak of the reactive power so as not to affect the active power of the PV. When the fitness value of Equation (3) is optimal according to the weight, the parameter could be used to represent a volt–var curve as shown in the Figure 7a, Figure 8a and Figure 9a which could maximize the system performance.

3.2. Simulation Results

Section 3.2 describes the simulation results for verifying the proposed algorithm. Figure 7 compared the effects of the conventional method and proposed a method for voltage deviation. Figure 7a shows the volt–var curve according to the cases and Figure 7b shows the voltage deviation index according to the volt–var curve. Case C which sets the highest weight ( ω 1 ) for voltage deviation was optimized for a curve with no dead-band, unlike other cases. Case C shows the most optimized result in terms of voltage deviation through this curve. The voltage deviation index near zero indicates near nominal voltage, which means improved system performance.
Figure 8 compares the effects of the conventional method and proposed method on the system losses. Figure 8a shows the optimized curves by the cases and Figure 8b shows the hourly system losses by the case. Case D which has the highest weight ( ω 2 ) for system loss shows that the system losses is the lowest. System losses are affected by various factors such as substation distance (transmission system), line impedance, PV output and load pattern.
Figure 9 compared the effects of the conventional method and proposed method for suppressing reactive power peak. Figure 9a shows the optimized curves for suppressing reactive power peak. Figure 9b shows hourly reactive power output of smart inverter according to the case. Because the W/O V-V case is not mounted with function, the reactive power does not contribute to the distribution system. The reactive power peak of case A is 0.1385 [p.u.], the reactive power peak of case B is 0.0352 [p.u.], the reactive power peak of case C is 0.03 [p.u.]. The best reason for the peak suppression effect is that the reactive power command is the smallest in the area where the curve of case C is generated from the peak.

4. Discussions

Section 4 discusses the results of the proposed algorithm. Table 4 shows the results of the simulation. The factors indicated per unit are shown to make it easier to analyze the improvement effect compared to the conventional method. The improvement effect on the maximum voltage and the minimum voltage is most effective in case C which has a high weighting on the voltage deviation. Further, case C is the minimum value for the sum of voltage deviation for one year. In terms of system loss, it is confirmed that case D, which has the highest weight for system loss, improves by 6.2% when the function is not applied (W/O V-V) and by 2% compared to case A. In terms of suppressing the peak of reactive power, case E was found to be up to 75% of the limitation effect. In terms of the evaluation index (fitness value), case B, which applied the same weight to each system performance index, improved by 22% compared to case A. Although the fitness values of case B and case E are similar, case B considers the whole part of the system factors identically, and case E has an effect of suppressing reactive power because it applies a high weight to the reactive power suppression.

5. Conclusions

This paper proposed an algorithm that optimizes the volt–var function parameter of the smart inverter which is a method for mitigating over-voltage due to high penetration of the distributed generation. In order to improve the system performance, voltage deviation and system losses which are indicators of the distribution system, were minimized. Further, the peak of the reactive power was minimized in order to avoid affecting the output of the distributed generation. As a result, the system performance was effectively improved depending on how the weight is selected during the optimization process. Improving the system performance by weighting could provide various options to the DSOs.
The algorithm proposed in this paper has the following advantages:
  • Through the test model considering the distribution system characteristics of South Korea, this paper verified that the over-voltage problem caused by the high penetration of the distributed generation was solved by the volt–var function (Check through Case A).
  • The parameter settings of the volt–var function were optimally set through a multi-objective function considering the voltage deviation, the system losses and the suppression peak of the reactive power (Check Case B).
  • Case C improved by setting more weight to the voltage deviation. This optimization case could be applied when hosting capacity increases and power quality improvements are needed.
  • Case D validated the effect by setting more weight to improve the system losses. This optimization case could be applied to situations where system loss is to be minimized such as a long distance feeder and distributed generation line.
  • Case E is an optimization to minimize the peak of the reactive power in order to not affect the output of the distributed generation. This optimization case is applicable to the state that needs to suppress the peak of the reactive power due to capacity limitation of the PCS and new installation of the smart inverter.
The algorithm proposed in this paper could improve the system performance such as voltage deviation and system losses for the DSOs. In addition, individual businesses could maximize profits by not affecting output of the distributed generation. According to the system condition, the system performance could be maximized through the algorithm proposed in this paper.

Author Contributions

Methodology and Writing-original draft, H.-J.L.; software, K.-H.Y.; validation, J.-W.S., supervision, J.-C.K.; editing, S.-M.C. All authors have read and agreed to the published version of the manuscript.

Funding

This research was supported in part by Korea Electric Power Corporation (Grant number:R18XA04), This work was supported by the Korea Institute of Energy Technology Evaluation and Planning (KETEP) and the Ministry of Trade, Industry & Energy (MOTIE) of the Republic of Korea (No. 2019381010001B).

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Ministry of Trade, Industry and Energy (MOTIE). Renewable Energy 3020 Implement Plan; Ministry of Trade, Industry and Energy (MOTIE): Sejong, Korea, 2017. [Google Scholar]
  2. Ministry of Trade, Industry and Energy (MOTIE). The 8th Electricity Demand and Supply Basic Plan (2017–2031); Ministry of Trade, Industry and Energy (MOTIE): Sejong, Korea, 2017. [Google Scholar]
  3. Choi, H.Y. South Korean Government Releases Draft of Plans to Increase Renewable Energy Use. HANKYOREH. 2017. Available online: http://english.hani.co.kr/arti/english_edition/e_national/825098.html (accessed on 17 February 2020).
  4. Kim, H.; Park, H. PV Waste Management at the Crossroads of Circular Economy and Energy Transition: The Case of South Korea. Sustainability 2018, 10, 3565. [Google Scholar] [CrossRef] [Green Version]
  5. Yun, C.Y.; Kim, C.K.; Kim, J.Y.; Kim, H.G.; Kang, Y.H.; Kim, Y.I. Solar Potential Analysis in Korea using GIS-based information. In Proceedings of the 2018 IEEE 7th World Conference on Photovoltaic Energy Conversion (WCPEC) (A Joint Conference of 45th IEEE PVSC, 28th PVSEC & 34th EU PVSEC), Waikoloa Village, HI, USA, 10–15 June 2018. [Google Scholar]
  6. Moon, W.S.; Hur, J.-S.; Kim, J.-C. A Protection of interconnection transformer for DG in Korea distribution power system. In Proceedings of the IEEE Power and Energy Society General Meeting, San Diego, CA, USA, 22–26 July 2012. [Google Scholar]
  7. Yun, S.Y.; Hwang, P.I.; Moon, S.I.; Kwon, S.C.; Song, I.K.; Choi, J.H. Development and Field Test of Voltage VAR Optimization in the Korean Smart Distribution Management System. Energies 2014, 7, 643–669. [Google Scholar] [CrossRef]
  8. Hwang, P.I.; Moon, S.I.; Jeong, M.G.; Song, I.K. Volt/var optimization of the korean smart distribution management system. In Proceedings of the 22nd International Conference and Exhibition on Electricity Distribution (CIRED 2013), Stockholm, Sweden, 10–13 June 2013. [Google Scholar]
  9. Reno, M.J. PV Locational Hosting Capacity Analysis. Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). In Proceedings of the IEEE Power and Energy Society General Meeting Panel, Boston, MA, USA, 17–21 July 2016. [Google Scholar]
  10. Go, S.I.; Ahn, S.J.; Choi, J.H.; Jung, W.W.; Chu, C.M. Development and test of conservation voltage reduction application for Korean Smart Distribution Management System. In Proceedings of the 2015 IEEE Power & Energy Society General Meeting, Denver, CO, USA, 26–30 July 2015. [Google Scholar]
  11. Kim, M.Y.; Song, Y.U.; Kim, K.H. The Advanced Voltage Regulation Method for ULTC in Distribution Systems with DG. J. Electr. Eng. Technol. 2013, 8, 737–743. [Google Scholar] [CrossRef] [Green Version]
  12. Suh, J.; Hwang, S.; Jang, G. Development of a Transmission and Distribution Integrated Monitoring and Analysis System for High Distributed Generation Penetration. Energies 2017, 10, 1282. [Google Scholar] [CrossRef] [Green Version]
  13. Lee, H.O.; Huh, J.S.; Kim, B.K.; Rho, D.S.; Kim, J.C. Improvement Method of SVR Control in Power Distribution System Interconnected Distributed Generator. Trans. Korean Electr. Inst. Electr. Eng. 2014, 63, 224–229. [Google Scholar]
  14. Lee, H.O.; Huh, J.S.; Kim, C.H.; Kim, J.C. A Study on the SVR Optimal Placement in Distribution System with Distributed Generators. J. Korean Inst. Illum. Electr. Install. Eng. 2013, 27, 69–75. [Google Scholar]
  15. Lee, H.O. A Study on Optimal Placement and Voltage Control Method of SVR in Smart Grid. Doctoral Dissertation, Soongsil University, Seoul, Korea, 2014. Available online: http://www.riss.kr/search/detail/DetailView.do?p_mat_type=be54d9b8bc7cdb09&control_no=984b4e498373b3d9ffe0bdc3ef48d419 (accessed on 17 February 2020).
  16. Kobayashi, T.; Aoki, H. SVR optimal placement problem in distribution network with Distributed Generators. In Proceedings of the 2012 IEEE Power and Energy Society General Meeting, San Diego, CA, USA, 22–26 July 2013. [Google Scholar]
  17. Kim, Y.S.; Kim, G.H.; Lee, J.D.; Cho, C. New Requirements of the Voltage/VAR Function for Smart Inverter in Distributed Generation Control. Energies 2016, 9, 929. [Google Scholar] [CrossRef] [Green Version]
  18. O’Connell, A.; Keane, A. Volt–var curves for photovoltaic inverters in distribution systems. IET Gener. Trans. Distrib. 2017, 11, 730–739. [Google Scholar] [CrossRef]
  19. Montenegro, D.; Bello, M. Coordinating Control Devices and Smart Inverter Functionalities in the Presence of Variable Weather Conditions. In Proceedings of the 2018 IEEE/PES Transmission and Distribution Conference and Exposition (T&D), Denver, CO, USA, 16–19 April 2018. [Google Scholar]
  20. Jafari, M.; Olowu, T.O.; Sarwat, A.I. Optimal Smart Inverters Volt-VAR Curve Selection with a Multi-Objective Volt-VAR Optimization using Evolutionary Algorithm Approach. In Proceedings of the 2018 North American Power Symposium (NAPS), Fargo, ND, USA, 9–11 September 2018. [Google Scholar]
  21. Dao, V.T.; Ishii, H.; Hayashi, Y. Optimal parameters of volt–var functions for photovoltaic smart inverters in distribution networks. IEEJ Trans. Electr. Electr. Eng. 2018, 14, 75–84. [Google Scholar] [CrossRef] [Green Version]
  22. Ding, F.; Nguyen, A.; Walinga, S.; Nagarajan, A.; Baggu, M.; Chakraborty, S.; McCarty, M.; Bell, F. Application of autonomous smart inverter Volt-VAR function for voltage reduction energy savings and power quality in electric distribution systems. In Proceedings of the 2017 IEEE Power & Energy Society Innovative Smart Grid Technologies Conference (ISGT), Washington, DC, USA, 23–26 April 2017. [Google Scholar] [CrossRef]
  23. Ding, F.; Nagarajan, A.; Chakraborty, S.; Baggu, M.; Nguyen, A.; Walinga, S.; McCarty, M.; Bell, F. Photovoltaic Impact Assessment of Smart Inverter Volt-VAR Control on Distribution System Conservation Voltage Reduction and Power Quality; Office of Scientific and Technical Information (OSTI), National Renewable Energy Lab. (NREL): Golden, CO, USA, 2016. [Google Scholar]
  24. Takasawa, Y.; Akagi, S.; Yoshizawa, S.; Ishii, H.; Hayashi, Y. Effectiveness of updating the parameters of the Volt-VAR control depending on the PV penetration rate and weather conditions. In Proceedings of the 2017 IEEE Innovative Smart Grid Technologies—Asia (ISGT-Asia), Auckland, New Zealand, 4–7 December 2017. [Google Scholar]
  25. Rylander, M.; Reno, M.J.; Quiroz, J.E.; Ding, F.; Li, H.; Broderick, R.J.; Mather, B.; Smith, J. Methods to determine recommended feeder-wide advanced inverter settings for improving distribution system performance. In Proceedings of the 2016 IEEE 43rd Photovoltaic Specialists Conference (PVSC), Portland, OR, USA, 5–10 June 2016. [Google Scholar]
  26. Takasawa, Y.; Akagi, S.; Yoshizawa, S.; Ishii, H.; Hayashi, Y. Evaluation of Voltage Regulation Functions of Smart Inverters Based on Penetration Level and Curtailment in Photovoltaic Systems. In Proceedings of the 2018 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT-Europe), Sarajevo, Bosnia-Herzegovina, 21–25 October 2018. [Google Scholar]
  27. Bello, M.; Montenegro, D.; York, B.; Smith, J. Optimal Settings for Multiple Groups of Smart Inverters on Secondary Systems Using Autonomous Control. In Proceedings of the 2017 IEEE Rural Electric Power Conference (REPC), Columbus, OH, USA, 23–25 April 2017. [Google Scholar]
  28. Abate, S.R.; McDermott, T.E.; Rylander, M.; Smith, J. Smart inverter settings for improving distribution feeder performance. In Proceedings of the 2015 IEEE Power & Energy Society General Meeting, Denver, CO, USA, 26–30 July 2015. [Google Scholar]
  29. Seuss, J.; Reno, M.J.; Lave, M.; Broderick, R.J.; Grijalva, S. Advanced inverter controls to dispatch distributed PV systems. In Proceedings of the 2016 IEEE 43rd Photovoltaic Specialists Conference (PVSC), Portland, OR, USA, 5–10 June 2016. [Google Scholar]
  30. Reno, M.J.; Lave, M.S.; Broderick, R.J.; Seuss, J.; Smith, S.G. Multi-Objective Advanced Inverter Controls to Dispatch the Real and Reactive Power of Many Distributed PV Systems; Office of Scientific and Technical Information (OSTI), Sandia National Lab. (SNL-NM): Albuquerque, NM, USA, 2016. [Google Scholar] [CrossRef]
  31. Choi, J.H.; Kim, J.C. Network reconfiguration at the power distribution system with dispersed generations for loss reduction. In Proceedings of the 2000 IEEE Power Engineering Society Winter Meeting, Conference Proceedings (Cat. No.00CH37077), Singapore, 23–27 January 2000. [Google Scholar]
  32. Seal, B. Common Functions for Smart Inverters 4th Edition 3002008217; EPRI Report; Electric Power Research Institute (EPRI): Palo Alto, CA, USA, 2016. [Google Scholar]
  33. van Zandt, D. Mitigation Methods to Increase Feeder Hosting Capacity 3002013382; EPRI Report; Electric Power Research Institute (EPRI): Palo Alto, CA, USA, 2018. [Google Scholar]
  34. Southern California Edison. 2019 Static Load Profiles. 2019. Available online: https://www.sce.com/regulatory/load-profiles (accessed on 17 February 2020).
  35. Korea Western Power Company Limited; Photovoltaic Generation Status of Korea Western Power Company Limited. 2019. Available online: https://www.data.go.kr/dataset/15025486/fileData.do (accessed on 17 February 2020).
  36. Nelson, A.; Martin, G.; Hurtt, J. Experimental evaluation of grid support enabled PV inverter response to abnormal grid conditions. In Proceedings of the 2017 IEEE Power & Energy Society Innovative Smart Grid Technologies Conference (ISGT), Washington, DC, USA, 23–26 April 2017. [Google Scholar]
  37. Cho, G.J. A Study on Power System Planning and Operational Scheme Establishment for Achieving Maximum Penetration Level of Distributed Generation. Ph.D. Thesis, Sungkyunkwan University, Seoul, Korea, 2019. Retrieved from Research Information Sharing Service (RISS). Available online: http://www.riss.kr/search/detail/DetailView.do?p_mat_type=be54d9b8bc7cdb09&control_no=d0810e5092bdb877ffe0bdc3ef48d419 (accessed on 17 February 2020).
  38. Sarmiento, J.E.; Carreno, E.M.; de Souza, A.C.Z. Modeling inverters with volt–var functions in grid-connected mode and droop control method in islanded mode. Electr. Power Syst. Res. 2018, 155, 265–273. [Google Scholar] [CrossRef]
  39. Rini, D.P.; Shamsuddin, S.M.; Yuhaniz, S.S. Particle swarm optimization: Technique, system and challenges. Int. J. Comput. Appl. 2011, 14, 19–26. [Google Scholar] [CrossRef]
  40. Kalogerakis, C.; Koutroulis, E.; Lagoudakis, M.G. Global MPPT Based on Machine-Learning for PV Arrays Operating under Partial Shading Conditions. Appl. Sci. 2020, 10, 700. [Google Scholar] [CrossRef] [Green Version]
  41. James, K.; Russell, E. Particle swarm optimization. In Proceedings of the ICNN’95-International Conference on Neural Networks, Perth, WA, Australia, 27 November–1 December 1995. [Google Scholar]
  42. Korea Electric Power Company (KEPCO). Regulation on the Use of Electrical Equipment for Transmission Distribution System (Appendix 4). Available online: http://cyber.kepco.co.kr/ckepco/front/jsp/CY/H/C/CYHCHP00704.jsp# (accessed on 17 February 2020).
Figure 1. Test Model considering Characteristics of Distribution System in South Korea [7,13,14,15,31].
Figure 1. Test Model considering Characteristics of Distribution System in South Korea [7,13,14,15,31].
Energies 13 02294 g001
Figure 2. South Korea’s One-Year PV Output and Power Usage Pattern of Load. (a) Power Usage Pattern of Load [34]. (b) PV Output Pattern [35].
Figure 2. South Korea’s One-Year PV Output and Power Usage Pattern of Load. (a) Power Usage Pattern of Load [34]. (b) PV Output Pattern [35].
Energies 13 02294 g002
Figure 3. Volt–Var Function Curve. (a) Common Volt–Var Function Curve [23,24,28]. (b) Standard Default Setting of Volt–Var Function [25,33,36].
Figure 3. Volt–Var Function Curve. (a) Common Volt–Var Function Curve [23,24,28]. (b) Standard Default Setting of Volt–Var Function [25,33,36].
Energies 13 02294 g003
Figure 4. Determining Inverter’s Reactive Power Limit Range [18,23,29,37,38].
Figure 4. Determining Inverter’s Reactive Power Limit Range [18,23,29,37,38].
Energies 13 02294 g004
Figure 5. Voltage Profile when Volt–Var Function was applied or not.
Figure 5. Voltage Profile when Volt–Var Function was applied or not.
Energies 13 02294 g005
Figure 6. Flowchart for Setting Optimal Parameter of Volt–Var Function.
Figure 6. Flowchart for Setting Optimal Parameter of Volt–Var Function.
Energies 13 02294 g006
Figure 7. Case Comparison to verify the Improvement Effect on Voltage Deviation Index.
Figure 7. Case Comparison to verify the Improvement Effect on Voltage Deviation Index.
Energies 13 02294 g007
Figure 8. Case Comparison to verify the Improvement Effect on System Losses.
Figure 8. Case Comparison to verify the Improvement Effect on System Losses.
Energies 13 02294 g008
Figure 9. Case Comparison to verify the Improvement Effect on Limiting Reactive Power Peak.
Figure 9. Case Comparison to verify the Improvement Effect on Limiting Reactive Power Peak.
Energies 13 02294 g009
Table 1. Parameters of Test Model.
Table 1. Parameters of Test Model.
ClassificationParameter
Photovoltaic (PV) Capacity10 [MW]
Power Conditioning System (PCS) Capacity11 [MVA]
Each Load500 [kW]/225 [kVAR]
Transformer154/22.9 [kV], 45/60 [MVA]
Line Impedance ( A C S R 160 mm 2 )0.182 + j0.391 [ Ω /km]
Table 2. Voltage Operating Regulation Range of Distribution System in South Korea.
Table 2. Voltage Operating Regulation Range of Distribution System in South Korea.
Nominal VoltageVoltage Operating Regulation Range
22,900 [V] (1.0 [p.u.])20,800 [V] (0.908 [p.u.] ∼ 23,800 [V] (1.039 [p.u.]) (−2100 ∼ +900)
Table 3. Case Configuration.
Table 3. Case Configuration.
Case ω 1 ω 2 ω 3 Remark
W/O V-V---Without Volt–Var Function (Conventional Method without Function)
Case A---Standard Default Setting (Conventional Method with Function)
Case B111Equal Weight for All Elements
Case C211Priority to Voltage Deviation
Case D121Priority to System Losses
Case E112Priority to Reducing Peak of Reactive Power
Table 4. Simulation Results.
Table 4. Simulation Results.
ClassificationW/O V-VCase ACase BCase CCase DCase E
Maximum Voltage [p.u.]1.0451.0351.0381.0171.0381.038
Minimum Voltage [p.u.]0.9380.9570.9380.9730.9680.938
Sum of Voltage Deviation [Index]307.26236.11306.97134.89155.23307.01
Sum of Voltage Deviation [p.u.]1.03131.00001.30010.57130.65741.3003
System Losses [MWh/Year]975.39933.39975.89940.75914.60975.81
System Losses [p.u.]1.04501.00001.04551.00790.97991.0454
Peak of Reactive Power [kVAR]-1384.90355.451407.781224.30352.94
Peak of Reactive Power [p.u.]-1.00000.25671.01650.88400.2548
Fitness Value (Equation (3))-32.34562.59572.53582.3457

Share and Cite

MDPI and ACS Style

Lee, H.-J.; Yoon, K.-H.; Shin, J.-W.; Kim, J.-C.; Cho, S.-M. Optimal Parameters of Volt–Var Function in Smart Inverters for Improving System Performance. Energies 2020, 13, 2294. https://doi.org/10.3390/en13092294

AMA Style

Lee H-J, Yoon K-H, Shin J-W, Kim J-C, Cho S-M. Optimal Parameters of Volt–Var Function in Smart Inverters for Improving System Performance. Energies. 2020; 13(9):2294. https://doi.org/10.3390/en13092294

Chicago/Turabian Style

Lee, Hyeong-Jin, Kwang-Hoon Yoon, Joong-Woo Shin, Jae-Chul Kim, and Sung-Min Cho. 2020. "Optimal Parameters of Volt–Var Function in Smart Inverters for Improving System Performance" Energies 13, no. 9: 2294. https://doi.org/10.3390/en13092294

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop