Article

Flexible Electrochemical Platform Coupled with In Situ Prepared Synthetic Receptors for Sensitive Detection of Bisphenol A

School of Chemistry and Chemical Engineering, Yangzhou University, Yangzhou 225002, China
*
Author to whom correspondence should be addressed.
Biosensors 2022, 12(12), 1076; https://doi.org/10.3390/bios12121076
Submission received: 16 October 2022 / Revised: 15 November 2022 / Accepted: 21 November 2022 / Published: 25 November 2022
(This article belongs to the Special Issue Biosensing and Diagnosis)

Abstract

:
A flexible electrochemical sensor based on the carbon felt (CF) functionalized with Bisphenol A (BPA) synthetic receptors was developed. The artificial Bisphenol A receptors were grafted on the CF by a simple thermal polymerization molecular imprinting process. Fourier-transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM) and electrochemical characterizations were used to analyze the receptors. Characterization results demonstrated that the Bisphenol A synthetic receptors successfully formed on the CFs surface. Because the synthetic receptor and the porous CFs were successfully combined, the sensor displayed a better current response once Bisphenol A was identified. The sensor’s linear range was determined to be from 0.5 to 8.0 nM and 10.0 to 300.0 nM, with a detection limit of 0.36 nM. Even after being bent and stretched repeatedly, the electrode’s performance was unaffected, demonstrating the robustness, adaptability and viability of installing the sensor on flat or curved surfaces for on-site detection. The designed electrochemical sensor has been used successfully to identify Bisphenol A in milk samples with satisfactory results. This work provided a promising platform for the design of implantable, portable and miniaturized sensors.

1. Introduction

Endocrine disruptors (EDC) are exogenous chemicals that disrupt the human endocrine system and increase the risk of diabetes, obesity, cardiovascular disease and prostate cancer [1]. Bisphenol A (2,2-bis (4-hydroxyphenyl) propane, BPA) has been functionalized as a kind of EDC to disturb the human endocrine system due to its structural resemblance to estrogen. However, Bisphenol A is a precursor material for the synthesis of epoxy resins, polycarbonate and polysulfone resins [2]. It is frequently present in plastic products, the inner coating of canned food and food packaging bags. Long-term storage and heat treatment can lead to the penetration of Bisphenol A into food from packaging materials [3,4]. This has raised concerns about food safety [5]. Therefore, the analysis and detection of Bisphenol A are particularly important.
Several analytical methods have been reported for the detection of Bisphenol A, including high-performance liquid chromatography (HPLC) [6], liquid chromatography-mass spectrometry (LC-MS) [7], gas chromatography-mass spectrometry (GC-MS) [8], spectrophotometry [9] and enzyme-linked immunosorbent assay (ELISA) [10]. However, the chromatography and mass spectrometry-based methods are expensive, time-consuming and require complex sample pretreatment. ELISA method is readily available from many manufacturers, but the preparation of antibodies is labor-intensive and expensive. ELISA method also suffers from the instability of biomolecules and short signal stability [11]. Therefore, the development of new methods with simplicity, stability and sensitivity that can detect trace amounts of Bisphenol A residue has become a major research challenge.
Electrochemical analysis technology with low cost, fast response speed and high sensitivity is a promising option for the development of inexpensive, simple and convenient Bisphenol A sensors [12,13,14]. Bisphenol A has two phenolic hydroxyl groups, which can be oxidized easily on the electrode surface [15]. This character makes it possible to identify Bisphenol A using straightforward electrochemical techniques. It is crucial to choose a material to enhance the performance of the electrochemical sensor when an electrochemical approach is put into practice. Currently, several materials, such as carbon nanomaterials and transition metal oxides, have been utilized as electrode modifiers to improve the electrochemical sensitivity for Bisphenol A detection [16,17,18]. However, the oxidation products of Bisphenol A would produce non-conductive polymers on the electrode surface, deactivating the electrode surface and preventing further reactions [19]. When Bisphenol A was first recognized and accumulated on the electrode surface, the selectivity and sensitivity of the electrochemical sensor could be improved [20].
In recent years, synthetic receptors have been widely used in sensing platforms for recognition and accumulation. Molecularly imprinted polymers (MIPs) have become a research hotspot due to their superior selectivity over natural receptors, increased physicochemical stability and better selectivity [21,22]. Hamed E M et al. have summarized the different production methods and the varied types of sensors that employed MIPs for Bisphenol A detection [23]. Nanomaterials with large surface areas are always modified on the rigid electrodes to construct the electrochemical sensors [24]. However, the growing demand for portable and wearable electronics demands is beyond the capacity of rigid electrodes. It is important and necessary to build flexible sensors with good sensitivity and selectivity. CFs have received a lot of interest as a flexible electrode material due to their rich porosity structure and effective adsorption. Compared with conventional rigid electrodes, CF electrodes can be simply regenerated by ultrasonic cleaning [25]. The CF electrode can further be modified to offer a larger specific surface area, more active sites and better recognition ability [26]. In this work, a molecularly imprinted polymer layer was deliberately modified on the surface of a CF electrode by a simple in situ thermal polymerization process to fabricate a novel and sensitive electrochemical sensor for the detection of Bisphenol A [27]. Figure 1 depicts the preparation and application of the MIP@CF sensor for the detection of Bisphenol A. The molecularly imprinted precursor solution was created using the ideal molar ratio of Bisphenol A to methacrylic acid (MAA) and then was thermally polymerized on the surface of the CF. After the release of the template molecule Bisphenol A, the imprinted cavity of Bisphenol A remained on the MIP@CF electrode as the layer with selectivity. The imprinted cavity reidentified the Bisphenol A and provided an electrochemical response signal during the detecting procedure. Cyclic voltammetry (CV) was utilized to evaluate the electro-oxidation behaviors of the identified Bisphenol A, and differential pulse voltammetry (DPV) was employed to quantify Bisphenol A in real samples.

2. Experimental

2.1. Reagents and Apparatus

Graphite CFs, 2 mm thick, were purchased from Tianjin Carbon Factory (Tianjin, China). Acetonitrile (MW:41.05), ethanol (MW:46.07), methacrylic acid (MAA, MW: 86.09), Bisphenol A (MW:228.29), protocatechuic acid (PCA, MW:154.1), ascorbic acid (AA, MW:176.12), catechol (CC, MW:110.11) and hydroquinone (HQ, MW:110.11) with analytically purity were all purchased from Sinopharm Chemical Reagent Co., Ltd. (Shanghai, China). Ethylene glycol dimethacrylate (EGDMA, MW:198.22) was bought from Aladdin Industrial Corporation (Shanghai, China). Azobisisobutyronitrile (AIBN, MW:164.21) was obtained from Shanghai Shisi Hewei Chemical Co., Ltd. (Shanghai, China). All the reagents were of analytical grade and were used as received without further purification.
GeminiSEM 300 (German Carl Zeiss Co., Carl, Germany) was used to characterize the morphologies of the materials. The molecular structures of CF, Bisphenol A, Bisphenol A–MIP@CF and MIP@CF were checked and compared using a Cary 610/670 FTIR microscope (Varian, Palo Alto, CA, USA). The pH of solutions was adjusted using PHS-25 pH meter (Shanghai INESA Scientific Instrument Co., Ltd., Shanghai, China). A traditional three-electrode system was used for all the electrochemical experiments on a CHI-1040C workstation (Chenhua, Shanghai, China), using CF, MIP@CF and NIP@CF as working electrodes (working area = 1 cm2), a platinum wire as the counter electrode and an Ag/AgCl electrode as the reference electrode, respectively.

2.2. Preparation of MIP or NIP Modified Electrodes

The CFs were cut into 1.0 cm × 1.5 cm before they were ultrasonically cleaned with ethanol and deionized water for 15 min, respectively, then they were dried in a vacuum oven at 60 °C for 2 h for further use.
The MIP precursor solution was prepared by dissolving template Bisphenol A (0.5 mmol) and functional monomer MAA (2.5 mmol) in 12.5 mL of acetonitrile solution, stirring at room temperature for 3 h to make a homogeneous mixture. Then, 10 mmol of crosslinking agent EGDMA and 40 mg of initiator AIBN were added in turn, and the mixture was further stirred for 10 min, followed by bubbling with nitrogen for 20 min. Finally, the mixture was heated in a water bath at 60 °C for 30 min to form a pre-polymerized solution [28,29].
To prepare MIP–modified electrodes, the CFs were saturated with a pre-polymerized solution (400 μL) before being put on an electric heating table at 60 °C for in situ thermal polymerizations for 4 h. The obtained electrodes were named Bisphenol A–MIP@CF before the elution operation. Lastly, the BPA–MIP@CF electrode was immersed in acetic acid/methanol (1:9, V:V) eluent until the template molecule was fully removed. The resulting electrode was named MIP@CF. For comparison, NIP@CF electrodes were fabricated by the same procedure, except that the template molecule Bisphenol A was not added to the precursor solution during the polymerization process.

2.3. Bisphenol A Electrochemical Measurement

The incubation solution was a mixture of acetonitrile and PBS with a volume ratio of 1:9 and Bisphenol A with various concentrations. The MIP@CF was incubated at room temperature for a period of time in the incubation solution. Then the obtained electrode was taken out, thoroughly washed with PBS three times, and then immersed in a blank PBS solution for electrochemical analysis. The difference of current in MIP@CF electrode before and after capturing Bisphenol A reflects the concentrations of Bisphenol A.

2.4. Real Sample Analysis

Pure milk samples were purchased from a local supermarket. 2 mL of milk was diluted with 10 mL of PBS and centrifuged at 12,000 rpm for 15 min. The supernatant was collected and centrifuged again. Then, a certain amount of supernatant was mixed with PBS for electrochemical analysis. A certain amount of Bisphenol A standard solutions were added to the milk samples to determine the recovery rates of the assay.

3. Results and Discussions

3.1. Characterization of CF, Bisphenol A–MIP@CF, MIP@CF

The surface morphologies of CF, Bisphenol A–MIP@CF and MIP@CF were analyzed and characterized by SEM. It was observed that the CF was composed of cross-linked networks (Figure 2A). The huge voids between carbon fibers were conductive to the transport of the incubation solution during the recognition process, while the cross-linked fibers were beneficial to the electron transfer to promote the electrocatalytic oxidation of Bisphenol A on the electrode [30,31,32]. In addition, there were abundant parallel cracks on the surface of carbon fiber (Figure 2B), and this roughness was beneficial for surface modification [33]. After the CF was modified by molecular imprinting technology, the diameter of the fiber was increased from 9.42 μm to 9.81 μm. The fiber surface became rough, and some bulk substances were loaded (Figure 2C,D), which may be the synthesized Bisphenol A molecularly imprinted polymers. For the MIP@CF electrode, as shown in Figure 2E,F, it could be clearly observed that the surface blocks were reduced, and the diameter of the fiber was slightly decreased to 9.76 μm. The elution process removed the template from the polymers. During this process, the loosely adhered polymer agglomerates were removed from the surface [34,35].
FTIR spectra of bare CF, Bisphenol A, BPA–MIP@CF and MIP@CF were studied and compared in Figure 3. The differences in these spectra confirmed the integration of new functional groups on the surface of the CF after imprinting. Compared with the bare CF (curve a) and Bisphenol A (curve b), the stretching vibration peak of the methylene group in the CF after Bisphenol A imprinting appeared at 2968 cm−1, and the characteristic peak of the benzene ring appeared at 1500 cm−1–1300 cm−1, which proved that the Bisphenol A molecule was successfully imprinted on the surface of the CF (curve c). No peak in the range of 1500 cm−1–1300 cm−1 was observed in this position of CF after elution of Bisphenol A, indicating that Bisphenol A has been successfully eluted from the electrode surface [36]. In addition, the characteristic absorption peaks at 1703 cm−1, 1292 cm−1 and 1136 cm−1 were observed from curves c and d, which were attributed to the C=O vibration peaks of carboxyl group in MAA and the symmetric and asymmetric stretching vibration peaks of C-O of ester group in EGDMA. The methylene peak, which was attributed to the C-H stretching of the methylene group of EGDMA and AIBN, also appears at 2998 cm−1 [37,38,39]. These results indicated that Bisphenol A had been successfully imprinted on the surface of CF, and a molecular imprint cavity was formed after elution.

3.2. Flexibility Tests of MIP@CF

The MIP@CF electrodes express superior flexibility. CV images under different bending angles and twist times were studied. Figure 4A showed that the shapes of the CV curves were basically unchanged after the electrode bending angle was from 0 to 180°. In addition, CV curves remain almost unchanged after twisting 50 times (Figure 4B), indicating that bending and twisting did not affect the electrochemical performance of the electrode [40,41,42]. The insets of Figure 4A,B also confirmed the flexibility of the electrodes. Almost no change was observed in the oxidation and reduction peak current after bending and twisting (Figure 4C,D). The results showed that the electrode has good application potential in flexible electronics.

3.3. Electrochemical Behaviors of Different Modified Electrodes

The electrochemical behaviors of different electrodes were compared using the CV technique. Figure 5A showed the CV of the CF, BPA–MIP@CF, MIP@CF and NIP@CF in KCl solution containing 5 mM [Fe(CN)6]3−/4−. It can be seen from the figure that the bare CF electrode, without any modification, exhibits an obvious pair of well-separated redox peaks (curve a), indicating the good electron transfer ability of CF. Compared with the unmodified CF, the BPA–MIP@CF only showed an oxidation peak current at Epa of 605 mV. The redox peaks of [Fe(CN)6]3−/4− disappeared (curve b). The polymer film on the CF inhibited the transfer of the [Fe(CN)6]3−/4− to the electrode, so the redox peaks of [Fe(CN)6]3−/4− were diminished. However, Bisphenol A imprinted in the polymer film could be oxidized at Epa of 605 mV [43]. The CV of NIP@CF supported this conclusion (curve d). No oxidation or reduction peak was observed on the NIP@CF. The formed non-conductive polymer layer on the CF hindered the electron transfer of [Fe(CN)6]3−/4−. The lack of the oxidation peak at around 605 mV also supported the fact that the peak was attributed to the oxidation of Bisphenol A [39]. The curve c in Figure 5A was the CV response of MIP@CF, which left the cavity on the polymer after the removal of Bisphenol A template. The redox peak of [Fe(CN)6]3−/4− appeared again. After the elution of the template from the polymer, some cavities were left on the polymer. [Fe(CN)6]3−/4− could diffuse through these cavities to the conductive CF surface, and electron transfer process was performed on the CF. The redox current on MIP@CF was slightly larger than that on the bared CF. This means that the extraction of template resulted in plenty of transport channels that were favorable to the redox reactions of [Fe(CN)6]3−/4−. The sensing performance of the MIP@CF for Bisphenol A detection was evaluated by comparing the oxidation current and oxidation potential of Bisphenol A on CF and MIP@CF. It can be seen from Figure 5B that Bisphenol A has obvious oxidation peak on both electrodes, and no corresponding reduction peak was found in the reverse scanning. This result indicates that the oxidation reaction of Bisphenol A on both electrodes was irreversible. Furthermore, the MIP@CF electrode (a) exhibited a significantly strong oxidation peak for Bisphenol A compared with bare CF (b). This was due to the specific recognition and accumulation of Bisphenol A by the imprinted sites [44]. The scan rate study is possible to understand whether the oxidation/reduction reaction mechanism of the analyte is controlled by adsorption or diffusion process. The CV responses of 1.0 μM of Bisphenol A on a MIP@CF were recorded at different scan rates (Figure S1). The oxidation peak current increased gradually with the increase in scan rate with a linear relationship in the range of 10–100 mVs−1. The corresponding linear regression equation was: Ip (mA) = 0.00065 + 0.0227 υ (mVs−1). This indicated that the oxidation of Bisphenol A on the MIP@CF was a typical adsorption-controlled process [45]. These results indicated that the MIP@CF can be used as an electrochemical tool for sensitive detection of Bisphenol A.
The pH value of the solution was an important parameter because it affected the oxidation potential of Bisphenol A. As shown in Figure 5C,D, the peak potential of Bisphenol A shifted negatively when the pH value increased from 5.0 to 9.0. The linear relationship between the oxidation peak potential (Ep) and pH was: Ep(V) = −0.0659·pH + 1.10822 (R2 = 0.994). The slope of 66 mV/pH is close to the theoretical value of 59 mV/pH unit. The results showed that the oxidation reaction of Bisphenol A on the MIP@CF was accompanied by an equal amount of proton and electron transfer processes [46].

3.4. Parameters Optimization for Sensor Preparation

In order to obtain the optimal sensing performance of the MIP@CF sensor for Bisphenol A detection, various experimental parameters were studied and optimized. Since the molar ratio of the template molecule and the functional monomer played an important role in the structure and rebinding affinity of the polymer, the molar ratio of Bisphenol A and MAA was adjusted from 1:3 to 1:8, and the corresponding oxidation peak currents were measured respectively. As shown in Figure 6A, the oxidation current value was the largest when the Bisphenol A: MAA ratio was 1:5. On the one hand, when the molar ratio of MAA continued to increase, excessive MAA monomer hindered the recognition site of Bisphenol A and resulted in a decrease in oxidation current. On the other hand, when the proportion of template molecule Bisphenol A was too high, insufficient number of monomers led to insufficient polymerization, and it was difficult to form effective imprinting binding sites. The obtained MIP film would have lower imprinting efficiency [47]. Therefore, the optimal molar ratio of template molecule to functional monomer was set as 1:5 in the preparation of the MIP@CF sensor.
The thermal polymerization time would influence the formation of the MIP layer on the CF surface and thus affect the performance of the MIP@CF sensor. It can be seen from Figure 6B that the oxidation current value gradually increases as the polymerization time increases and reaches the maximum current value at 4 h. However, the current value decreases as time continues to increase. This showed that the imprinted site had reached saturation after 4 h of thermal polymerization. Therefore, 4 h served as the optimal polymerization time for subsequent experiments.
Figure 6C shows that the current value of the oxidation peak is influenced by the pH of the detection solution. The peak current is the largest when pH 7.0 PBS is used. At higher pH, the decrease in peak current may be due to the electrostatic repulsion of the negatively charged anionic Bisphenol A to the sensor surface [48]. Therefore, a pH of 7.0 PBS was subsequently selected for the detection of Bisphenol A.
Figure 6D shows the effect of incubation time on the oxidative current after the MIP@CF sensor was incubated in the recognition solution, which contained Bisphenol A at different times. The oxidation current value gradually increased with the prolongation of incubation time and reached the maximum value after 20 min. So 20 min was selected as the optimum recognition time for Bisphenol A detection.

3.5. Sensing-Performance of MIP@CF in Bisphenol A Detection

The analytical performance of MIP@CF for Bisphenol A detection was evaluated by differential voltammetry pulse method (DPV). Figure 7A shows the response of different concentrations of Bisphenol A on the MIP@CF. It was observed that the peak currents increased linearly with the concentration of Bisphenol A. Figure 7B showed the linear relationship between DPV peak currents and Bisphenol A concentrations. Two calibration curves could be seen in the figure. In 0.5 nM to 8.0 nM range, the regression equation was: IP(μA) = 13.28·C (nM) + 14.18. Bisphenol A was easily converted into its oxidation products on the electrode surface in this lower concentration range and had a high detection sensitivity. In 10.0 nM to 300.0 nM range, the regression equation was: IP(μA) = 0.843·C (μM) + 173.47. The identification of the target and the diffusion of reaction products at high concentrations require more oxidation reaction time than when the concentration is low. Moreover, the surface of the MIP@CF electrode will be contaminated by high concentration of oxidation products. These facts result in relatively low detection sensitivity. The limit of detection (LOD) was as low as 0.36 nM based on 3 s y / x b , where s y / x was the standard deviation of y-intercepts of the regression line and b was the slope of the calibration curve in the low concentration range of Bisphenol A [49].
Compared with other methods shown in Table 1, this work exhibits better sensing performance in terms of wider linear range and lower detection limit.

3.6. Selectivity

The selectivity of the method was evaluated by measuring the DPV responses of different interfering substances on the MIP@CF sensors. The electrodes were incubated in 0.5 μM of Bisphenol A or 5.0 μM of the interferences, including protocatechuic acid (PCA), ascorbic acid (AA), catechol (CC) and hydroquinone (HQ). The DPV responses of these compounds are shown in Figure S2. There was almost no oxidation peak of these interfering substances near the specific oxidation peak potential of Bisphenol A, and the high response signal to Bisphenol A verified the high selectivity of the sensor. Figure 8A shows the current responses of Bisphenol A and the interfering substances at about 0.6 V. It was shown that the presence of 10 times interferences does not have significant effects on the oxidation peak of Bisphenol A. The presence of the special binding site regions in MIP polymers ensures the specific recognition of Bisphenol A at the imprinted site through the hydrogen bonds and Van der Waals force and makes the sensor have good selectivity. The special oxidation peak potential also contributed to the good selectivity of the sensor for Bisphenol A detection.

3.7. Reproducibility and Stability of the Sensor

The reproducibility of the MIP@CF sensor for 0.5 μM of Bisphenol A was measured by measuring the current responses of five different modified electrodes to Bisphenol A under the optimal conditions. Figure 8B,C showed the result that the relative standard deviation (RSD) of the five electrodes was 3.7%, indicating the excellent reproducibility of the sensor. The prepared electrodes were stored in a refrigerator at 4 °C for 12 days, and the response of the electrodes to the same concentration of Bisphenol A was measured every 2 days to determine its stability. The results showed that the relative standard deviation (RSD) of the method was 4.1%, indicating the acceptable stability of the sensor.

3.8. Real Samples Analysis

To verify the analytical potential of the sensor in the detection of real samples, the sensor was applied to detect Bisphenol A in pure milk samples. Bisphenol A was not detected in pure milk samples. Therefore, the recovery experiments were performed. A certain amount of Bisphenol A was added to the pure milk samples, and the recoveries were tested (Figure S3). The analysis results are shown in Table 2. It could be seen that the recovery of Bisphenol A is between 91.26–112%. The results showed that MIP@CF can be used as a novel electrochemical sensor for the detection of Bisphenol A in real samples.

4. Conclusions

In this work, a Bisphenol A synthetic receptor was deliberately modified on a flexible CF by a simple thermal polymerization process to construct a Bisphenol A electrochemical sensor. The receptor and the flexible CF work together to give the sensor excellent sensitivity, stability, selectivity and flexibility. This sensor showed linear DPV current responses to Bisphenol A from 0.5 to 8.0 nM and 10.0 to 300.0 nM. A good recovery result was obtained when this sensor was applied for the detection of Bisphenol A in milk samples. This work provides an effective way for the development of versatile electrochemical sensing platforms for the diagnosis of EDCs.

Supplementary Materials

The following supporting information can be downloaded at: https://www.mdpi.com/article/10.3390/bios12121076/s1. Figure S1. (A) CVs of 1.0 μmol·L−1 BPA at MIP@CF electrode at different scan rates; (B) The oxi-dation peak currents of 1.0 μmol·L−1 BPA against scan rates; Figure S2. DPV responses of the MIP@CF electrode in pH 7.0 PBS solution after the recognition of 0.5 μM of Bisphenol A or 5.0 μM of protocatechuic acid (PCA), ascorbic acid (AA), catechol (CC), and hydroquinone (HQ); Figure S3. Electrochemical response of MIP@CF for milk sample analysis.

Author Contributions

Conceptualization, C.-Y.X., Q.X. and X.-Y.H.; methodology, C.-Y.X. and K.-P.N.; software, Y.Y.; validation, C.-Y.X., K.-P.N. and Q.X.; formal analysis, C.-Y.X. and Z.W.; investigation, C.-Y.X. and Z.W.; resources, X.-Y.H.; data curation, C.-Y.X., K.-P.N. and Q.X; writing—original draft preparation, C.-Y.X., writing—review and editing, Q.X. and X.-Y.H.; visualization, C.-Y.X. and Z.W.; supervision, Q.X.; project administration, C.-Y.X., Y.Y. and Q.X.; funding acquisition, Q.X. All authors have read and agreed to the published version of the manuscript.

Funding

This research was funded by NSFC (22076161, 21675140 and 21705141), the Talent Support Program of Yangzhou University, the Open Project Program of Jiangsu Key Laboratory of Zoonosis (No. R2013), Yangzhou University Interdisciplinary Research Foundation for Chemistry Discipline of Targeted Support (yzuxk202009), the project funded by the PAPD and TAPP.

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

Not applicable.

Acknowledgments

We thank the Test Center of Yangzhou University for the SEM and TEM characterizations.

Conflicts of Interest

The authors declare no conflict of interest.

Abbreviations

BPA: Bisphenol A; FTIR: Fourier-transform infrared spectroscopy; SEM: Scanning electron microscope; S/N: signal to noise; EDC: Endocrine disruptor; HPLC: high-performance liquid chromatography; LC-MS: liquid chromatography-mass spectrometry; GC-MS: gas chromatography-mass spectrometry; ELISA: enzyme-linked immunosorbent assay; MIP: Molecularly imprinted polymers; CF: carbon felt; MAA: methacrylic acid; DPV: differential voltammetry pulse method; EGDMA: ethylene glycol dimethacrylate; NIP: non-molecularly imprinted polymers; AIBN: Azobisisobutyronitrile; PBS: phosphate buffered saline; MW: molecular weight.

References

  1. Xu, W.; Zhang, Y.; Yin, X.; Zhang, L.; Cao, Y.; Ni, X.; Huang, W. Highly sensitive electrochemical BPA sensor based on titanium nitride-reduced graphene oxide composite and core-shell molecular imprinting particles. Anal. Bioanal. Chem. 2021, 413, 1081–1090. [Google Scholar] [CrossRef] [PubMed]
  2. Zhang, Y.; Mi, K.; Xue, W.; Wei, W.; Yang, H. Acute BPA exposure-induced oxidative stress, depressed immune genes expression and damage of hepatopancreas in red swamp crayfish Procambarus clarkii. Fish Shellfish Immun. 2020, 103, 95–102. [Google Scholar] [CrossRef] [PubMed]
  3. Shim, K.; Kim, J.; Shahabuddin, M.; Yamauchi, Y.; Hossain, S.A.; Kim, J.H. Efficient wide range electrochemical bisphenol-A sensor by self-supported dendritic platinum nanoparticles on screen-printed carbon electrode. Sens. Actuators B 2018, 255, 2800–2808. [Google Scholar] [CrossRef]
  4. Li, Y.; Gao, Y.; Cao, Y.; Li, H. Electrochemical sensor for bisphenol A determination based on MWCNT/melamine complex modified GCE. Sens. Actuators B 2012, 171–172, 726–733. [Google Scholar] [CrossRef]
  5. Su, B.; Shao, H.; Li, N.; Chen, X.; Cai, Z.; Chen, X. A sensitive bisphenol A voltammetric sensor relying on AuPd nanoparticles/graphene composites modified glassy carbon electrode. Talanta 2017, 616, 126–132. [Google Scholar] [CrossRef] [PubMed]
  6. Zhang, Y.; Yuan, Z.-L.; Deng, X.-Y.; Wei, H.-D.; Wang, W.-L.; Xu, Z.; Feng, Y.; Shi, X. Metal-organic framework mixed-matrix membrane-based extraction combined HPLC for determination of bisphenol A in milk and milk packaging. Food Chem. 2022, 386, 132753. [Google Scholar] [CrossRef]
  7. Ma, W.; Wan, S.; Lin, C.; Lin, X.; Xie, Z. Towards online specific recognition and sensitive analysis of bisphenol A by using AuNPs@aptamer hybrid-silica affinity monolithic column with LC-MS. Talanta 2020, 219, 121275. [Google Scholar] [CrossRef]
  8. Correia-Sá, L.; Norberto, S.; Delerue-Matos, C.; Calhau, C.; Domingues, V.F. Micro-QuEChERS extraction coupled to GC–MS for a fast determination of Bisphenol A in human urine. J. Chromatogr. B 2018, 1072, 9–16. [Google Scholar] [CrossRef] [Green Version]
  9. Temel, N.K.; Gürkan, R. A micellar sensitized kinetic method for quantification of low levels of bisphenol A in foodstuffs by spectrophotometry. Anal. Methods 2017, 9, 1190. [Google Scholar] [CrossRef]
  10. Lei, Y.; Fang, L.; Akash, M.S.H.; Liu, Z.; Shi, W.; Chen, S. Development and comparison of two competitive ELISAs for the detection of bisphenol A in human urine. Anal. Methods 2013, 5, 6106. [Google Scholar] [CrossRef]
  11. Peng, Y.; Wang, J.; Wu, C. Determination of Endocrine Disruption Potential of Bisphenol A Alternatives in Food Contact Materials Using In Vitro Assays: State of the Art and Future Challenges. J. Agric. Food Chem. 2019, 67, 12613–12625. [Google Scholar] [CrossRef] [PubMed]
  12. Gao, Y.; Wang, L.; Shen, C.; Wang, C.; Hu, X.; Wang, G. An electrochemical sensor on the hierarchically porous Cu-BTC MOF platform for glyphosate determination. Sens. Actuators B 2019, 283, 487–494. [Google Scholar]
  13. Yu, L.; Zhang, Q.; Yang, B.; Xu, Q.; Xu, Q.; Hu, X. Electrochemical sensor construction based on Nafion/calcium lignosulphonate functionalized porous graphene nanocomposite and its application for simultaneous detection of trace Pb2+ and Cd2+. Sens. Actuators B 2018, 259, 540–551. [Google Scholar] [CrossRef]
  14. Mao, A.; Li, H.; Jin, D.; Yu, L.; Hu, X. Fabrication of electrochemical sensor for paracetamol based on multi-walled carbon nanotubes and chitosan–copper complex by self-assembly technique. Talanta 2015, 144, 252–257. [Google Scholar] [CrossRef] [PubMed]
  15. Fu, S.; Zhu, Y.; Zhang, Y.; Zhang, M.; Zhang, Y.; Qiao, L.; Yin, N.; Song, K.; Liu, M.; Wang, D. Recent advances in carbon nanomaterials-based electrochemical sensors for phenolic compounds detection. Microchem. J. 2021, 171, 106776. [Google Scholar] [CrossRef]
  16. Sanko, V.; Şenocak, A.; Tümay, S.O.; Orooji, Y.; Demirbas, E.; Khataee, A. An electrochemical sensor for detection of trace-level endocrine disruptor bisphenol A using Mo2Ti2AlC3 MAX phase/MWCNT composite modified electrode. Environ. Res. 2022, 212, 113037. [Google Scholar] [CrossRef] [PubMed]
  17. Teymoori, N.; Raoof, J.B.; Khalilzadeh, M.A.; Ojani, R. An electrochemical sensor based on CuO nanoparticle for simultaneous determination of hydrazine and bisphenol A. J. Iran. Chem. Soc. 2018, 15, 2271–2279. [Google Scholar] [CrossRef]
  18. Akilarasan, M.; Kogularasu, S.; Chen, S.-M.; Chen, T.-W.; Lin, S.-H. One-step synthesis of reduced graphene oxide sheathed zinc oxide nanoclusters for the trace level detection of bisphenol A in tissue papers. Ecotoxicol. Environ. Saf. 2018, 161, 699–705. [Google Scholar] [CrossRef]
  19. Tsekeli, T.R.; Sebokolodi, T.I.; Karimi-Maleh, H.; Arotiba, O.A. A Silver-Loaded Exfoliated Graphite Nanocomposite Anti-Fouling Electrochemical Sensor for Bisphenol A in Thermal Paper Samples. ACS Omega 2021, 6, 9401–9409. [Google Scholar] [CrossRef]
  20. Ren, Y.; Ma, W.; Ma, J.; Wen, Q.; Wang, J.; Zhao, F. Synthesis and properties of bisphenol A molecular imprinted particle for selective recognition of BPA from water. J. Colloid Interf. Sci. 2012, 367, 355–361. [Google Scholar] [CrossRef]
  21. Pei, D.-N.; Zhang, A.-Y.; Pan, X.-Q.; Si, Y.; Yu, H.-Q. Electrochemical Sensing of Bisphenol A on Facet-Tailored TiO2 Single Crystals Engineered by Inorganic-Framework Molecular Imprinting Sites. Anal. Chem. 2018, 90, 3165–3173. [Google Scholar] [CrossRef]
  22. Jiang, H.; Jiang, D.; Shao, J.; Sun, X. Magnetic molecularly imprinted polymer nanoparticles based electrochemical sensor for the measurement of Gram-negative bacterial quorum signaling molecules (N-acyl-homoserine-lactones). Biosens. Bioelectron. 2016, 75, 411–419. [Google Scholar] [CrossRef] [PubMed]
  23. Hamed, E.M.; Li, S.F.Y. Molecularly imprinted polymers-based sensors for bisphenol-A: Recent developments and applications in environmental, food and biomedical analysis. Trends Environ. Anal. Chem. 2022, 35, e00167. [Google Scholar] [CrossRef]
  24. Karthika, P.; Shanmuganathan, S.; Viswanathan, S.; Delerue-Matos, C. Molecularly imprinted polymer-based electrochemical sensor for the determination of endocrine disruptor bisphenol-A in bovine milk. Food Chem. 2021, 363, 130287. [Google Scholar] [CrossRef] [PubMed]
  25. Kim, M.; Song, Y.E.; Xiong, J.-Q.; Kim, K.-Y.; Jang, M.; Jeon, B.-H.; Kim, J.R. Electrochemical detection and simultaneous removal of endocrine disruptor, bisphenol A using a carbon felt electrode. J. Electroanal. Chem. 2021, 880, 114907. [Google Scholar] [CrossRef]
  26. Pang, Y.-H.; Wang, Y.-Y.; Shen, X.-F.; Qiao, J.-Y. Covalent organic framework modified carbon cloth for ratiometric electrochemical sensing of bisphenol A and S. Microchim. Acta 2022, 189, 189. [Google Scholar] [CrossRef] [PubMed]
  27. He, S.; Zhang, L.; Bai, S.; Yang, H.; Cui, Z.; Zhang, X.; Li, Y. Advances of molecularly imprinted polymers (MIP) and the application in drug delivery. Eur. Polym. J. 2021, 143, 110179. [Google Scholar] [CrossRef]
  28. Kamel, A.H.; Jiang, X.; Li, P.; Liang, R. A paper-based potentiometric sensing platform based on molecularly imprinted nanobeads for determination of bisphenol A. Anal. Methods 2018, 10, 3890. [Google Scholar] [CrossRef]
  29. Liu, K.; Song, Y.; Song, D.; Liang, R. Plasticizer-free polymer membrane potentiometric sensors based on molecularly imprinted polymers for determination of neutral phenols. Anal. Chim. Acta 2020, 1121, 50–56. [Google Scholar] [CrossRef]
  30. Shi, J.; Chen, J.; Li, G.; An, T.; Yamashita, H. Fabrication of Au/TiO2 nanowires@carbon fiber paper ternary composite for visible-light photocatalytic degradation of gaseous styrene. Catal. Today 2017, 281, 621–629. [Google Scholar] [CrossRef]
  31. Zuo, T.-T.; Wu, X.-W.; Yang, C.-P.; Yin, Y.-X.; Ye, H.; Li, N.-W.; Guo, Y.-G. Graphitized Carbon Fibers as Multifunctional 3D Current Collectors for High Areal Capacity Li Anodes. Adv. Mater. 2017, 29, 1700389. [Google Scholar] [CrossRef] [PubMed]
  32. Wang, J.; Xu, Q.; Xia, W.W.; Shu, Y.; Jin, D.; Zang, Y.; Hu, X. High sensitive visible light photoelectrochemical sensor based on in-situ prepared flexible Sn3O4 nanosheets and molecularly imprinted polymers. Anal. Bioanal. Chem. 2018, 271, 215–224. [Google Scholar] [CrossRef]
  33. Chen, S.; Chu, X.; Wu, L.; Foord, J.S.; Hu, J.; Hu, H.; Yang, J. Three-Dimensional PbO2-Modified Carbon Felt Electrode for Efficient Electrocatalytic Oxidation of Phenol Characterized with In Situ ATR-FTIR. J. Phys. Chem. C 2022, 126, 912–921. [Google Scholar] [CrossRef]
  34. Dong, L.; Liu, X.; Xu, H.; Wu, D.; Gao, S.; Zhong, L.; Kong, Y. Improved chiral electrochemical recognition of tryptophan enantiomers based on three- dimensional molecularly imprinted overoxidized polypyrrole/MnO2/carbon felt composites. Chirality 2019, 31, 917–922. [Google Scholar] [CrossRef] [PubMed]
  35. Yang, Z.; Qin, T.; Niu, Y.; Zhang, Y.; Zhang, C.; Li, P.; Zhu, M.; Jia, Y.; Li, Q. Flexible visible-light-driven photoelectrochemical biosensor based on molecularly imprinted nanoparticle intercalation-modulated graphene fiber for ultrasensitive urea detection. Carbon 2020, 157, 457–465. [Google Scholar] [CrossRef]
  36. Xu, R.; Qian, X.; Zhang, Z.; Yuan, F.; Song, Y.; Liu, J.; Zhang, Q.; Wei, J. A molecularly Imprinted Electrochemical Sensor Based on NMWCNT/CPE for Highly Sensitive and Selective Detection of Bisphenol A. Int. J. Electrochem. Sci. 2022, 17, 220536. [Google Scholar] [CrossRef]
  37. Metwally, M.G.; Shehab, O.R.; Ibrahim, H.; Nashar, R.M.E. Electrochemical detection of Bisphenol A in plastic bottled drinking waters and soft drinks based on molecularly imprinted polymer. J. Environ. Chem. Eng. 2022, 10, 107699. [Google Scholar] [CrossRef]
  38. Pan, J.; Hu, W.; Dai, X.; Guan, W.; Zou, X.; Wang, X.; Huo, P.; Yan, Y. Molecularly imprinted polymers based on magnetic fly-ash-cenosphere composites for bisphenol A recognition. J. Mater. Chem. 2011, 21, 15741. [Google Scholar] [CrossRef]
  39. Zhou, G.; Cao, Y.; Jin, Y.; Wang, C.; Wang, Y.; Hua, C.; Wu, S. Novel selective adsorption and photodegradation of BPA by molecularly imprinted sulfur doped nano-titanium dioxide. J. Clean. Prod. 2020, 274, 122929. [Google Scholar] [CrossRef]
  40. Xu, M.; Song, Y.; Ye, Y.; Gong, C.; Shen, Y.; Wang, L.; Wang, L. A novel flexible electrochemical glucose sensor based on gold nanoparticles/polyaniline arrays/carbon cloth electrode. Sens. Actuators B 2017, 252, 1187–1193. [Google Scholar] [CrossRef]
  41. Wu, D.; Zhong, W. A new strategy for anchoring a functionalized graphene hydrogel in a carbon cloth network to support a lignosulfonate/polyaniline hydrogel as an integrated electrode for flexible high arealcapacitance supercapacitors. J. Mater. Chem. A 2019, 7, 5819. [Google Scholar] [CrossRef]
  42. Jiang, H.; Zhou, C.; Yan, X.; Miao, J.; You, M.; Zhu, Y.; Li, Y.; Zhou, W.; Cheng, X. Effects of various electrolytes on the electrochemistry performance of Mn3O4/carbon cloth to ultra-flexible all-solid-state asymmetric supercapacitor. J. Energy Storage 2020, 32, 101898. [Google Scholar] [CrossRef]
  43. Alam, A.U.; Deen, M.J. Bisphenol A Electrochemical Sensor Using Graphene Oxide and β-Cyclodextrin-Functionalized Multi-Walled Carbon Nanotube. Anal. Chem. 2020, 92, 5532–5539. [Google Scholar] [CrossRef]
  44. Zheng, W.; Xiong, Z.; Li, H.; Yu, S.; Li, G.; Niu, L.; Liu, W. Electrodeposited Pt@Molecularly imprinted polymer core-shell nanostructure: Enhanced sensing platform for sensitive and selective detection of bisphenol A. Sens. Actuators B 2018, 272, 655–661. [Google Scholar] [CrossRef]
  45. Yücebaşa, B.B.; Yücebaşa, Y.T.; Bolat, G.; Özgür, E.; Uzun, L.; Abaci, S. Molecular imprinted polymer based electrochemical sensor for selective detection of paraben. Sens. Actuators B 2020, 305, 127368. [Google Scholar] [CrossRef]
  46. Wang, Y.; Yin, C.; Zhuang, Q. An electrochemical sensor modified with nickel nanoparticle/nitrogen-doped carbon nanosheet nanocomposite for bisphenol A detection. J. Alloys Compd. 2020, 827, 154335. [Google Scholar] [CrossRef]
  47. Rawool, C.R.; Srivastava, A.K. A dual template imprinted polymer modified electrochemical sensor based on Cu metal organic framework/mesoporous carbon for highly sensitive and selective recognition of rifampicin and isoniazid. Sens. Actuators B 2019, 288, 493–506. [Google Scholar] [CrossRef]
  48. Wang, J.-Y.; Su, Y.-L.; Wu, B.-H.; Cheng, S.-H. Reusable electrochemical sensor for bisphenol A based on ionic liquid functionalized conducting polymer platform. Talanta 2016, 147, 103–110. [Google Scholar] [CrossRef]
  49. Desimoni, E.; Brunetti, B. About estimating the limit of detection by the signal to noise approach. Pharm. Anal. 2015, 6, 355. [Google Scholar]
  50. Ali, M.Y.; Alam, A.U.; Howlader, M.M.R. Fabrication of highly sensitive Bisphenol A electrochemical sensor amplified with chemically modified multiwall carbon nanotubes and β-cyclodextrin. Sens. Actuators B 2020, 320, 128319. [Google Scholar] [CrossRef]
  51. Li, Z.; Hu, J.; Xiao, Y.; Zha, Q.; Zeng, L.; Zhu, M. Surfactant assisted Cr-metal organic framework for the detection of bisphenol A in dust from E-waste recycling area. Anal. Chim. Acta 2021, 1146, 174–183. [Google Scholar] [CrossRef] [PubMed]
  52. Kesavan, G.; Nataraj, N.; Chen, S.-M.; Lin, L.-H. Hydrothermal synthesis of NiFe2O4 nanoparticles as an efficient electrocatalyst for the electrochemical detection of bisphenol A. New J. Chem. 2020, 44, 7698–7707. [Google Scholar] [CrossRef]
  53. Lei, Y.; Zhang, Y.; Wang, B.; Zhang, Z.; Yuan, L.; Li, J. A lab-on-injector device with Au nanodots confined in carbon nanofibers for in situ electrochemical BPA sensing in beverages. Food Control 2022, 134, 108747. [Google Scholar] [CrossRef]
  54. Naik, T.S.S.K.; Anil, A.G.; Swamy, B.E.K.; Singh, S.; Madhavi, V.; Raghavendra, S.M.; Ramamurthy, P.C. A novel electrochemical sensor based on 2,6-bis (2-benzimidazoyl) pyridine for the detection of Bisphenol A. Mater. Chem. Phys. 2022, 275, 125287. [Google Scholar] [CrossRef]
Figure 1. Schematic illustration of the preparation and application of MIP@CF sensor for the detection of BPA.
Figure 1. Schematic illustration of the preparation and application of MIP@CF sensor for the detection of BPA.
Biosensors 12 01076 g001
Figure 2. SEM images of bare CF (A,B), BPA–MIP@CF (C,D) and MIP@CF (E,F).
Figure 2. SEM images of bare CF (A,B), BPA–MIP@CF (C,D) and MIP@CF (E,F).
Biosensors 12 01076 g002
Figure 3. FTIR spectra of the CF (a), BPA (b), BPA–MIP@CF (c) and MIP@CF (d).
Figure 3. FTIR spectra of the CF (a), BPA (b), BPA–MIP@CF (c) and MIP@CF (d).
Biosensors 12 01076 g003
Figure 4. CVs of MIP@CF electrode with different bending angle (A) and twist time (B) in 5.0 mmol·L−1 K4[Fe(CN)6] with 0.1 mol·L−1 KCl at the scan rate of 50 mV·s−1; Relationship between the anodic (Ipa) and cathodic peak (Ipc) currents vs. bending angle (C) and twist time (D).
Figure 4. CVs of MIP@CF electrode with different bending angle (A) and twist time (B) in 5.0 mmol·L−1 K4[Fe(CN)6] with 0.1 mol·L−1 KCl at the scan rate of 50 mV·s−1; Relationship between the anodic (Ipa) and cathodic peak (Ipc) currents vs. bending angle (C) and twist time (D).
Biosensors 12 01076 g004
Figure 5. (A) CV responses of bare CF (a), BPA–MIP@CF (b), MIP@CF (c) and NIP@CF (d) in 5.0 mmol·L−1 K4[Fe(CN)6] with 0.1 mol·L−1 KCl at the scan rate of 50 mV·s−1; (B) CV curves of bare CF (b), MIP@CF (a) after recognizing 1.0 μM BPA; (C) CV responses of MIP@CF electrode at different pH (5.0, 6.0, 7.0, 8.0 and 9.0) after recognizing 1.0 μM BPA at the scan rate of 50 mV·s−1; (D) The relationship between the peak potentials and pH values.
Figure 5. (A) CV responses of bare CF (a), BPA–MIP@CF (b), MIP@CF (c) and NIP@CF (d) in 5.0 mmol·L−1 K4[Fe(CN)6] with 0.1 mol·L−1 KCl at the scan rate of 50 mV·s−1; (B) CV curves of bare CF (b), MIP@CF (a) after recognizing 1.0 μM BPA; (C) CV responses of MIP@CF electrode at different pH (5.0, 6.0, 7.0, 8.0 and 9.0) after recognizing 1.0 μM BPA at the scan rate of 50 mV·s−1; (D) The relationship between the peak potentials and pH values.
Biosensors 12 01076 g005
Figure 6. Plots of the oxidation currents of BPA versus (A) template/monomer ratio; (B) thermal polymerization time; (C) pH value of the detection solution and (D) elution time after the accumulation of 1.0 μM BPA.
Figure 6. Plots of the oxidation currents of BPA versus (A) template/monomer ratio; (B) thermal polymerization time; (C) pH value of the detection solution and (D) elution time after the accumulation of 1.0 μM BPA.
Biosensors 12 01076 g006
Figure 7. (A) DPV responses of BPA in blank pH 7.0 PBS after the recognition of different concentrations of BPA; (B) Calibration curves for BPA in the concentration ranges of 0.5 nM to 8.0 nM and 10.0 nM to 300.0 nM. The inset plot represented the calibration curve in the concentration ranges of 0.5 nM to 8.0 nM.
Figure 7. (A) DPV responses of BPA in blank pH 7.0 PBS after the recognition of different concentrations of BPA; (B) Calibration curves for BPA in the concentration ranges of 0.5 nM to 8.0 nM and 10.0 nM to 300.0 nM. The inset plot represented the calibration curve in the concentration ranges of 0.5 nM to 8.0 nM.
Biosensors 12 01076 g007
Figure 8. Investigating the selectivity of the MIP@CF sensor for 0.5 μM of Bisphenol A or 5.0 μM of the interferences (A), reproducibility (B) and stability (C) of MIP@CF electrodes for 5.0 μM of BPA.
Figure 8. Investigating the selectivity of the MIP@CF sensor for 0.5 μM of Bisphenol A or 5.0 μM of the interferences (A), reproducibility (B) and stability (C) of MIP@CF electrodes for 5.0 μM of BPA.
Biosensors 12 01076 g008
Table 1. Performance comparison of the prepared sensor for Bisphenol A detection with other sensors.
Table 1. Performance comparison of the prepared sensor for Bisphenol A detection with other sensors.
ElectrodeMethodLinear Range (μM)LOD (nM)Reference
MWCNTs-βCD/SPCELSV0.125–2/2–3013.7[50]
CTAB/MIL-101(Cr)DPV0.02–0.3510[51]
NiFe2O4/SPCEDPV0.02–12.56[52]
AgNPs-EGSWV5–100230[19]
AuNDs@CNFs/SPEDPV0.01–505[53]
GO-MWCNT-βCD/SPELSV0.05–5/5–306[43]
BZPY/MCPEDPV2–1829[54]
MIP@CFDPV0.0005–0.008/0.01–0.30.36This work
Table 2. Determination of BPA in real samples.
Table 2. Determination of BPA in real samples.
SampleOriginal (nM)Added (nM)Found (nM)Recovery (%)RSD (%)
Milk0.001.001.121123.96
0.0050.0051.28102.54.16
0.00200.00182.5091.263.54
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Xu, C.-Y.; Ning, K.-P.; Wang, Z.; Yao, Y.; Xu, Q.; Hu, X.-Y. Flexible Electrochemical Platform Coupled with In Situ Prepared Synthetic Receptors for Sensitive Detection of Bisphenol A. Biosensors 2022, 12, 1076. https://doi.org/10.3390/bios12121076

AMA Style

Xu C-Y, Ning K-P, Wang Z, Yao Y, Xu Q, Hu X-Y. Flexible Electrochemical Platform Coupled with In Situ Prepared Synthetic Receptors for Sensitive Detection of Bisphenol A. Biosensors. 2022; 12(12):1076. https://doi.org/10.3390/bios12121076

Chicago/Turabian Style

Xu, Chen-Yan, Kang-Ping Ning, Zheng Wang, Yao Yao, Qin Xu, and Xiao-Ya Hu. 2022. "Flexible Electrochemical Platform Coupled with In Situ Prepared Synthetic Receptors for Sensitive Detection of Bisphenol A" Biosensors 12, no. 12: 1076. https://doi.org/10.3390/bios12121076

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop