Targeted Delivery of Bioactive Molecules for Vascular Intervention and Tissue Engineering

  • 1Department of Biomedical Engineering, Worcester Polytechnic Institute, Worcester, MA, United States
  • 2Graduate School of Biomedical Sciences, University of Massachusetts Medical School, Worcester, MA, United States
  • 3Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, United States

Cardiovascular diseases are the leading cause of death in the United States. Treatment often requires surgical interventions to re-open occluded vessels, bypass severe occlusions, or stabilize aneurysms. Despite the short-term success of such interventions, many ultimately fail due to thrombosis or restenosis (following stent placement), or incomplete healing (such as after aneurysm coil placement). Bioactive molecules capable of modulating host tissue responses and preventing these complications have been identified, but systemic delivery is often harmful or ineffective. This review discusses the use of localized bioactive molecule delivery methods to enhance the long-term success of vascular interventions, such as drug-eluting stents and aneurysm coils, as well as nanoparticles for targeted molecule delivery. Vascular grafts in particular have poor patency in small diameter, high flow applications, such as coronary artery bypass grafting (CABG). Grafts fabricated from a variety of approaches may benefit from bioactive molecule incorporation to improve patency. Tissue engineering is an especially promising approach for vascular graft fabrication that may be conducive to incorporation of drugs or growth factors. Overall, localized and targeted delivery of bioactive molecules has shown promise for improving the outcomes of vascular interventions, with technologies such as drug-eluting stents showing excellent clinical success. However, many targeted vascular drug delivery systems have yet to reach the clinic. There is still a need to better optimize bioactive molecule release kinetics and identify synergistic biomolecule combinations before the clinical impact of these technologies can be realized.

Introduction

Every 40 seconds an American dies from cardiovascular disease, the leading cause of death in the United States. It is estimated that by 2030, 43.9% of Americans will be living with some form of cardiovascular disease (Go et al., 2014). Some diseases, such as atherosclerosis, can lead to life-threatening blood vessel occlusions. While some preventative medications exist, invasive procedures such as angioplasty, stenting, and bypass surgery are often required to restore blood vessel patency. However, these procedures provide only temporary solutions; it is estimated that up to 15–50% of angioplasties, 16–30% of saphenous vein bypass grafts, and up to 90% of synthetic coronary bypass grafts fail within 1–3 years (Lemson et al., 2000; Goldman et al., 2011; Kennealey et al., 2011; Siracuse et al., 2012; Marmagkiolis et al., 2014). Other vascular diseases such as aneurysm cannot currently be prevented or treated with medication, and must be surgically repaired.

Improvements in peripheral or coronary artery bypass grafting (CABG) in particular have made little clinical progress over the past several decades. The standard of care is to use autologous saphenous veins or internal mammary arteries as donor graft material. However, autologous vein and artery grafts are unavailable in approximately one-third of patients due to severity of vascular disease or previous surgeries (Veith et al., 1979). Synthetic grafts can be effective for surgical bypass of large diameter arteries. Coatings with molecules such as heparin have significantly improved outcomes in applications such as femoropopliteal bypass grafts (Devine et al., 2004; Walluscheck et al., 2005; Lindholt et al., 2011). However, synthetic materials still fail consistently when used as bypass grafts for high-flow, small diameter vessels, such as peripheral and coronary arteries (Pashneh-Tala et al., 2015). When used for CABG, polytetrafluoroethylene (PTFE) has a 2-year patency rate of only 32%, compared to greater than 90% for saphenous vein grafts (Chard et al., 1987; Shah et al., 2005; Hadinata et al., 2009). Thus, new alternatives may be needed for patients who lack suitable autologous grafts for bypass procedures.

Tissue engineered blood vessels (TEBVs) are being investigated as alternatives to synthetic grafts for CABG and other bypass grafting applications. TEBVs may be advantageous because they may more closely mimic the native structure and function of arteries than synthetic materials. In some cases, TEBVs may degrade and be entirely replaced by native tissue (Hibino et al., 2010). Several TEBVs have already been tested in clinical trials for hemodialysis access (Wystrychowski et al., 2014; Lawson et al., 2016) and cavopulmonary conduits (Hibino et al., 2010). While many advances have been made, TEBVs still face challenges such as incomplete endothelialization, thrombosis, stenosis following implantation, and limited function. For example, a recent clinical trial for hemodialysis access grafts reported 1-year primary patency rates of 28%, although secondary patency rates were 89% (Lawson et al., 2016). The low primary patency was primarily due to thrombosis. While this is an improvement over synthetic PTFE grafts, which have 41% primary and 59% secondary 1-year patency rates (Hodges et al., 1997), there is still room for improvement. Additionally, no TEBVs have moved forward into clinical trials specifically for CABG, as this is especially challenging due to the small diameter and high flow rate in the coronary artery. Controlled release of growth factors and other molecules directly within TEBVs may help address some of these problems.

While many different drugs have shown clinical efficacy for treating vascular disease, many are either ineffective or toxic when delivered systemically (Bea et al., 2002; Johnson et al., 2005; Marupudi et al., 2007). For example, statins, which are typically used to prevent restenosis, have also been shown to reverse existing atherosclerotic lesions, but only at doses that are toxic to humans (Bea et al., 2002; Johnson et al., 2005). Targeted delivery of these drugs using biomaterial and tissue engineering approaches may help solve this problem by allowing a much higher dose to be delivered directly to the diseased site.

In this review, we discuss how controlled release of drugs and growth factors can be used for a wide range of vascular intervention applications, from targeted treatment of vascular diseases to improving the function of TEBVs for bypass grafting. Many approaches have been developed to achieve targeted bioactive molecule delivery and localized release in the vasculature, including implantation of drug-eluting stents or bypass grafts, or delivery of specialized bioactive molecule-loaded nanoparticles designed to target sites of injury or disease.

Vascular Disease and Intervention – Opportunities for Targeted Drug Delivery

Localized drug delivery is an ideal strategy for treating vascular diseases such as atherosclerosis, restenosis, and aneurysm, as these focal diseases affect only a small region of the blood vessel. Systemic treatments for these diseases are often ineffective, or cause harmful side effects. To address this challenge, biomaterial approaches are being developed and tested clinically for delivering therapeutics directly to sites of injury and disease.

Atherosclerosis and Restenosis

Atherosclerosis is characterized by the buildup of lipids in the vascular wall, triggered by endothelial dysfunction and inflammation. If left untreated, unstable lesions with necrotic cores may rupture and trigger a life-threatening thrombosis. Even if they do not rupture, lesions can begin to occlude the vessel and restrict blood flow to vital organs. While some preventative medications exist, treatments for large or ruptured lesions are largely invasive. A balloon angioplasty can be inflated in a partial occlusion to restore blood flow (Figure 1A; balloon shown in blue). Stents can also be put in place to mechanically hold the vessel open for a longer period (Figure 1A). In severe cases, the diseased area may need to be replaced or bypassed altogether with a vascular graft (Libby and Theroux, 2005) (Figure 1B). While effective, each of these invasive treatments can damage the endothelium, triggering a cascade of events that leads to intimal hyperplasia (restenosis), or the overgrowth of smooth muscle cells (SMCs) into the vessel lumen (Kornowski et al., 1998). Drug-eluting biomaterials may be one solution to overcoming these problems by locally delivering treatments to heal or prevent these diseases.

FIGURE 1
www.frontiersin.org

FIGURE 1. Current interventions for vascular diseases, and their modes of failure. Stenosis (A), caused by atherosclerosis or intimal hyperplasia, is frequently treated with stent placement [blue balloon in (A) used to deploy stent] to restore patency. However, in-stent restenosis is a frequent complication. In severe cases of occlusion (B), a complete vessel bypass may be necessary. With bypass grafting, there is a risk of failure due to thrombosis or restenosis at graft anastomoses. Aneurysms (C) can be treated with an aneurysm coil, to fill the aneurysmal sac and prevent further dilation. However, over time coils can begin to leak, allowing fluid to re-enter and further enlarge the aneurysm.

Aneurysm

Aneurysms are caused by the localized degradation of the arterial elastin and elastic fibers by matrix metalloproteinases (MMPs). This causes the vascular wall to dilate and weaken, and ultimately rupture (Thompson and Parks, 1996). There are two types of aneurysms. Fusiform aneurysms affect the entire circumference of the vessel region, whereas saccular aneurysms affect only a focal region of the circumference.

There are limited options for treating aneurysms. Once they reach a critical size, surgical intervention becomes necessary. For fusiform aneurysms, the affected region is either replaced or reinforced with a synthetic vascular graft (Tarafdar and Gannon, 2017). For smaller saccular aneurysms in regions such as the brain, the dilated region can be surgically “clipped,” or tied off, so blood cannot flow into the dilated region, although this procedure is highly invasive. In some cases, “flow diverters” are used, which are specially designed stents that block blood from entering the aneurysm. Alternatively, a metallic coil can be guided up through the vasculature to the aneurysm, and essentially “stuffed” in to fill the dilation and prevent blood from entering (Pierot and Wakhloo, 2013) (Figure 1C).

Drug Delivery Opportunities for Vascular Intervention

There are numerous methods for incorporating drugs or growth factors into biomaterials, summarized schematically in Figure 2. Molecules such as heparin can be immobilized on the material surface, an approach which is frequently utilized for reducing thrombosis risk on synthetic vascular grafts (Biran and Pond, 2017). Growth factors can also be bound to heparin-coated surfaces. This strategy results in a longer, sustained release of growth factors than binding them to non-heparinized surfaces (Jeon et al., 2007).

FIGURE 2
www.frontiersin.org

FIGURE 2. Methods for incorporating bioactive molecules into medical devices or tissue engineered grafts. Growth factors can be tethered to graft surfaces, incorporated directly into material coatings, incorporated directly within scaffold materials during fabrication, or absorbed into the material post-fabrication.

Alternatively, therapeutics can be encapsulated within biomaterials during fabrication. For example, with emulsion electrospinning, growth factors are combined with a polymer solution and then electrospun into a scaffold with growth factor-encapsulating fibers (Zhang et al., 2013). Depending on the biomaterial used, molecules encapsulated by materials may be released by affinity interactions, diffusion, bulk or surface degradation of the material; or a combination of release mechanisms. This is advantageous because it enables sustained tunable release of the molecule with minimal burst release (Lee et al., 2007). Burst releases occur when a large portion of the molecules are released in a very short period of time, which can have toxic or other off-target effects on cells depending on the molecule released.

Molecules can also be loaded via diffusion into materials after fabrication, by soaking the material in a bioactive factor solution. For example, growth factors can diffuse into gelatin scaffolds and bind electrostatically to the gelatin. The growth factor is then released by dissociation and diffusion as the gelatin proteolytically degrades (Tabata and Ikada, 1998). Growth factor loading and release methods are reviewed in greater detail in Lee et al. (2011).

Each of these loading techniques results in materials with different bioactive factor release kinetics. Different types of release kinetics may be ideal for different applications. This wide range of available systems and achievable release kinetics may enable drug-delivery systems to be customized for many applications in tissue engineering and regenerative medicine.

Device Design Criteria

When designing drug-eluting biomaterials for tissue engineering or regenerative medicine, many factors need to be considered. It is critical that the material used is biocompatible and will not trigger any local or systemic toxic effects. Many drugs are released as material degrades, and polymer degradation products can be harmful to cells (Higgins et al., 2003). Consistency in the manufacturing process is also important; uneven drug loading may cause too much or too little drug to be delivered. The material fabrication process also plays a role in the effectiveness of a therapeutic. Growth factors, nucleic acids, and many drugs may denature and/or degrade upon heating, so if a heating step is required in the manufacturing process, the bioactivity of the molecules may be diminished. Any material intended for cell culture or implantation must be sterilized without degrading, and may need to be stored for extended periods of time. In some cases, it may be possible to load the material with a drug directly before use. However, this is not always an option, especially for treatments such as stent placement or angioplasty, where time is often a critical factor. Thus, an ideal drug-loaded biomaterial is stable enough for long-term storage and can be available off-the-shelf.

More specific design criteria varies considerably depending on the disease, target mechanism, delivery mechanism, and molecule being delivered. Thus, it is challenging to create broad specifications for drug-eluting biomaterial systems. The delivery mechanism must be designed in such a way that the molecule can reach its intended target. For example, a therapeutic that inhibits SMC proliferation, such as paclitaxel, must be able to penetrate the endothelium to reach the medial layer of the blood vessel. However, a nanoparticle that targets the endothelium, such as vascular endothelial growth factor (VEGF), may not need to penetrate beyond the luminal surface of the blood vessel. Different molecules may require different doses or release kinetics to be effective, depending on how long they remain in the tissue. For example, paclitaxel accumulates and remains in tissue for longer periods of time than sirolimus, and thus does not require as prolonged of a release (discussed further below) (Levin et al., 2004).

Localized Drug Delivery from Vascular Stents

Stent placement has been used to restore blood flow following partial vessel occlusions since the 1980s. However, the original bare-metal stents can trigger life threatening conditions such as thrombosis, and have high rates of restenosis (Chen et al., 2006). Drug-eluting stents can provide localized delivery of therapeutics directly to the blood vessel wall and prevent in-stent restenosis. When designing drug-eluting stents, many factors need to be considered. Optimizing the release kinetics is critical for maximizing drug effectiveness and minimizing adverse effects. Release profile and drug distribution within the tissue can be affected by a number of factors, including the properties of the drug (Bozsak et al., 2015), stent or coating material and drug release mechanism (Acharya and Park, 2006), stent geometry (Seo et al., 2016), coating thickness, stent-induced changes in blood flow patterns (Seo et al., 2016), initial drug loading concentration (Bozsak et al., 2015), presence of thrombi in and around the stent (Hwang et al., 2005), and drug absorption capacity of the surrounding tissue (Balakrishnan et al., 2007). Therapeutics discussed in this section are summarized in Table 1.

TABLE 1
www.frontiersin.org

TABLE 1. Molecules delivered for atherosclerosis treatment.

Paclitaxel and Sirolimus-Eluting Stents

The two original drug-eluting stents, Cypher and Taxus, were fabricated from stainless-steel scaffolds with a permanent polymer coating designed to release sirolimus (Cypher) or paclitaxel (Taxus). Both of these drugs are known to prevent SMC proliferation and migration (Marx et al., 1995; Axel et al., 1997). The Cypher and Taxus stents were approved by the FDA based on their ability to reduce restenosis compared to bare metal stents (Sousa et al., 2001; Grube et al., 2002; Morice et al., 2002; Colombo et al., 2003; Moses et al., 2003; Stone et al., 2004). However, reduced endothelialization and delayed healing compared to bare-metal stents led to high incidences of late in-stent thrombosis. This may be attributed to drug-mediated inhibition of endothelial cell (EC) proliferation, in addition to drug effects on target SMCs, and localized inflammation (Farb et al., 2001; Joner et al., 2006; Pfisterer et al., 2006; Finn et al., 2007a,b; Nakazawa et al., 2008). Sensitivities to the materials used may also play a role in prolonged inflammation (Suzuki et al., 2001).

Paclitaxel and sirolimus have different transport dynamics through the arterial wall, leading paclitaxel to accumulate in the adventitia, rather than the media (Levin et al., 2004). Additionally, modeling simulations indicate that paclitaxel unbinds from tissue 20 times slower than sirolimus, thus causing it to remain in the arterial wall for a longer duration than sirolimus (Balakrishnan et al., 2007; Bozsak et al., 2014; Bozsak et al., 2015). Because the Taxus stent delivers a relatively high dose of paclitaxel over 30 days, it may accumulate in very high levels in the arterial wall and trigger localized inflammation (Radeleff et al., 2010; Bozsak et al., 2015). This may be one possible explanation for why paclitaxel-eluting stents are less effective than sirolimus-eluting stents (Dibra et al., 2005; Kastrati et al., 2005). It is possible that decreasing the loading concentration of paclitaxel in stents and releasing either one short burst, or a much slower release over a period of years, may reduce buildup in the arterial wall, and prevent SMC hyperplasia without delaying the healing process (Bozsak et al., 2014; Bozsak et al., 2015).

The idea of designing stents with a large initial burst release has been applied to paclitaxel-eluting angioplasty balloons. These balloons deliver a short burst of targeted therapy to a diseased region, which accumulates and remains in the arterial wall for an extended period. Paclitaxel-eluting balloons have reduced restenosis rates compared to traditional angioplasty balloons (Rittger et al., 2012; Byrne et al., 2013; Miura et al., 2017). While paclitaxel-eluting stents have largely been phased out, it is possible that further optimization of their release kinetics may have improved clinical results. This highlights the importance of understanding and tuning the release kinetics and diffusion properties of therapeutics released by stents and other systems for each specific drug and clinical indication.

Second Generation Drug-Eluting Stents

Second-generation drug-eluting stents used similar designs to Taxus and Cypher, but with improved drug release kinetics, more biocompatible materials, and altered stent geometry. There are numerous commercially available variations of these designs, most of which elute sirolimus derivatives. As a result of these changes, clinical outcomes have improved compared to first generation designs, especially in improving stent safety, and this has led second generation drug-eluting stents to become the current gold standard (Navarese et al., 2013; Valgimigli et al., 2014; Kobayashi et al., 2016). However, others have suggested that the improvements have not reduced the overall risk of late in-stent thrombosis, indicating that a different approach to stent design is needed (Tada et al., 2013). Second generation drug-eluting stents are reviewed in detail in Ho et al. (2016) and Akinapelli et al. (2017).

Other Stent Designs

Despite the success of second-generation drug-eluting stents, restenosis and thrombosis remain a problem, and currently available drug-eluting stents may not be appropriate for all patients. Thus, other approaches to stent design are being developed. Immobilized heparin on the stent surface may be an additional option for preventing thrombosis. There is currently one commercially available heparin-eluting stent, the Viabahn stent, which is fabricated from a nitinol base with a heparin-bound ePTFE coating. The Viabahn stent demonstrated improved patency rates in clinical trials compared to bare-metal stents (Lammer et al., 2013; Saxon et al., 2013).

Polymer-free drug-eluting stents may be advantageous for patients with polymer sensitivities. While loading drugs onto metallic surface can be challenging, several different strategies have proven effective. For example, the Cre8 stent releases nanoparticles containing amphilimus from reservoirs on the abluminal side of the stent (Carrie et al., 2012). The BioFreedom stent adheres biolimus A9 to a micro-structured metallic surface (Urban et al., 2015). The VESTAsync stent has sirolimus loaded into a microporous hydroxyapatite coating (Costa et al., 2009; van der Giessen et al., 2009). These techniques have had comparable clinical results to second-generation drug-eluting stents, and may reduce the risk of delayed healing (Costa et al., 2009; Carrie et al., 2012; Urban et al., 2015).

More complex stent designs have focused on further optimizing drug release kinetics, in addition to material and mechanical properties. Stents containing reservoirs can be filled with drugs that are released through small holes on the abluminal side of the stent only, allowing for more targeted drug delivery over a longer period (Finkelstein et al., 2003; Krucoff et al., 2008). Other groups have tried using a layer-by-layer assembly approach to coating stents, with materials such as chitosan or hyaluronic acid and therapeutics such as heparin and growth factors, to further control and customize drug release kinetics (Meng et al., 2009; Hossfeld et al., 2013; Liu et al., 2013; Su et al., 2013). Layer-by layer assembly can allow for the release of multiple drugs, which may be more effective than single-drug approaches. For example, coatings releasing sirolimus and heparin have been tested, which act to prevent restenosis and thrombosis, respectively (Su et al., 2013). Heparin also has a high affinity for growth factors, which become immobilized on its surface. In Liu et al. (2013), heparin was immobilized to the stent surface using an avidin–biotin system, and then CD34 and VEGF are bound to the heparin, with the goal of accelerating endothelialization (Liu et al., 2013). Both of these studies have shown promise in vitro.

Bioresorbable Vascular Scaffolds

More recent studies are focused on creating bioresorbable drug-eluting stents, or vascular scaffolds, from either metallic or polymeric materials. By completely degrading, these bioresorbable vascular scaffolds may alleviate many of the negative effects observed with metallic polymer-coated drug-eluting stents. They may also allow for the restoration of normal function and vasomotion of the vessel (Serruys et al., 2016). With non-degradable stents, a permanent focal decrease in vascular compliance can cause regions of compliance mismatch, increasing the risk of restenosis (Farhan et al., 2009; Selvarasu et al., 2011).

The two most widely used polymeric bioresorbable vascular scaffolds, the DESolve and Absorb bioresorbable vascular scaffolds, are both fabricated from poly-L-lactic acid (PLLA), and elute novolimus and everolimus, respectively. The DESolve bioresorbable vascular scaffold degrades completely in about 1 year, while the Absorb bioresorbable vascular scaffold degrades in approximately 3 years. Initial clinical trials of both bioresorbable vascular scaffolds were promising (Abizaid et al., 2016; Serruys et al., 2016). However, recent studies suggested the overall risk of death is similar between second generation drug-eluting stents and bioresorbable vascular scaffolds (Pandya et al., 2016; Stone et al., 2016; El-Hayek et al., 2017), and the risk of very late thrombosis (1–2 years after implantation) may even be higher than in drug-eluting stents (Toyota et al., 2017). Still, more time is needed to determine the extent of other potential long-term benefits, such as restored vessel function.

In addition to degradable polymers, degradable metals can also be used for bioresorbable vascular scaffolds. The DREAMS 2G bioresorbable vascular scaffolds is fabricated from a magnesium alloy with a sirolimus-loaded PLA coating. When the magnesium alloy degrades, it is first converted into hydrated magnesium oxide, and then into magnesium phosphate. Then it is replaced by amorphous calcium phosphate, which remains in the tissue. The magnesium diffuses out of the tissue and is absorbed by the body. The entire degradation process takes about 1 year (Haude et al., 2016). In clinical trials, the DREAMS 2G bioresorbable vascular scaffold performed similarly to polymeric bioresorbable vascular scaffolds, although long-term studies and direct comparisons are still needed (Haude et al., 2016). Bioresorbable vascular scaffolds are reviewed in detail in Bowen et al. (2016) and Ho et al. (2016).

Future of Stent Design

While release kinetics are critical to the performance of drug-eluting stents, they are extremely challenging to measure in vivo. This makes it difficult to engineer stents with specific release profiles, and several design iterations may be needed to achieve the desired outcome. Recent mathematical models combining in vitro with in vivo studies have increased our understanding of therapeutic drug release from stents, which may help reduce the number of iterations needed for success (McGinty et al., 2013, 2017; Bozsak et al., 2014, 2015). In the future, these models may be key to fabricating stents that deliver therapeutics at doses that inhibit SMC proliferation and prevent restenosis, but without toxic effects on ECs that have resulted in delayed healing, inhibition of re-endothelialization, and late thrombosis.

Many new molecules also hold promise for improving future drug-eluting stent designs. The possibility of delivering small-interfering ribonucleic acid (siRNA delivery) is currently being investigated (Hossfeld et al., 2013; Che et al., 2016; Cho and Park, 2017). siRNA are short double-stranded RNA molecules that interfere with the expression of specific genes. Stents have incorporated siRNA with the goal of reducing adhesion molecule receptors to reduce thrombosis and inflammation (Hossfeld et al., 2013), or suppressing SMC proliferation and preventing restenosis (Che et al., 2016). Gene-eluting stents are also being explored, as targeted gene therapy may upregulate production of growth factors or other molecules that may reduce intimal hyperplasia and thrombosis [reviewed in detail in (Yin et al., 2014) and (Adeel and Sharif, 2016)].

As a wider range of stent materials and therapeutics become available with different dosage kinetics, stent selection may be tailored to an individual patient’s needs, in order to deliver the most beneficial dosage of a specific therapeutic(s) to the diseased location for a precise duration.

Nanoparticle-Mediated Drug Delivery for Restenosis Prevention

For minor atherosclerotic lesions, targeted drug delivery via nanoparticles may be a less invasive option than stents or vascular grafts. Nanoparticles have been used clinically for targeted drug delivery to cancerous tumors [reviewed in (Brannon-Peppas and Blanchette, 2012)]. For atherosclerosis, many nanoparticles are in clinical trials to aid in imaging and diagnosing lesions. These specialized nanoparticles may be visible with imaging techniques such as MRI, and others may deliver contrast agents directly to the diseased site [reviewed in (Palekar et al., 2015)]. Here, we will focus on nanoparticles that are in development for the delivery of therapeutics to heal atherosclerotic lesions or prevent their progression.

Nanoparticle Design

The success of any nanoparticle-mediated treatment is determined by the nanoparticles’ ability to reach their target, typically following intravenous injection, and to provide the optimal dose of drug over a sustained period. These qualities are determined by the nanoparticle size (Walkey et al., 2012; Tan et al., 2013), surface properties (Walkey et al., 2012), particle geometry (Tan et al., 2013), shear stress and flow rate in the blood vessel (Klingberg et al., 2015), and drug release kinetics (Panyam and Labhasetwar, 2004). Many different materials have been used for fabricating drug-eluting nanoparticles, including synthetic polymers [reviewed in (Wang et al., 2016)], lipoproteins [reviewed in (Damiano et al., 2013; Harisa and Alanazi, 2014)], lipids (Shiozaki et al., 2016), and metals (Weakley et al., 2011). Different materials and design criteria may be needed depending on the type of drug to be released, and the intended target of the nanoparticle.

In addition to material considerations, the nanoparticle targeting mechanism must be considered (Figure 3). After injection, nanoparticles face several barriers to reaching their target. They may be uptaken by macrophages, distribution may be limited by blood flow, pressure gradients, or cellular internalization [reviewed in (Blanco et al., 2015)]. Thus, developing an effective targeting mechanism may increase nanoparticles’ ability to reach their intended target. Direct application via balloon angioplasty can be used, although intravenous injection is more common. Nanoparticles may naturally accumulate in atherosclerotic lesions, due to increased endothelial permeability at the diseased site, a process known as passive targeting (Duivenvoorden et al., 2014). This is the most common approach for nanoparticles targeting atherosclerotic lesions. Measuring the exact percent targeting efficiency of nanoparticles in vivo is challenging, as nanoparticles rapidly distribute throughout the body. Still, it is often possible to use labeled nanoparticles to measure relative concentration in select organs. For example, van der Valk et al. (2015) reported that 75% of plaque macrophages contained nanoparticles after IV injection with passive targeting. Still, it is unknown what fraction of injected nanoparticles remain in the body. Some materials can alternatively be taken up by macrophages or monocytes in the bloodstream, which may then accumulate in atherosclerotic plaque (Katsuki et al., 2014). Others may be magnetically guided to the diseased site (Chorny et al., 2009). Alternatively, active targeting may be used, where nanoparticles are conjugated with antibodies targeting specific proteins that are overexpressed at sites of vascular injury, such as collagen IV (Fredman et al., 2015), E-selectin (Ma et al., 2016), vascular cell adhesion molecule 1 (VCAM-1) (Nahrendorf et al., 2006), CD36 (Nie et al., 2015), and αvβ3 integrin (Winter et al., 2008). These active targeting systems may improve nanoparticles ability to reach their target. For example, the collagen IV targeting system described in Fredman et al. (2015) compared nanoparticle accumulation in the liver, spleen, and aorta, and found that 70% of measured particles were in the aorta. In addition, nanoparticles activated by elevated shear stresses have been developed. Regions of luminal narrowing caused by atherosclerosis, restenosis, or thrombosis experience elevated levels of shear. Thus, nanoparticles that release therapeutics when exposed to high shear stresses may be effective for targeting atherosclerotic lesions or intimal hyperplasia (Korin et al., 2012). Nanoparticle design is further reviewed in Blanco et al. (2015).

FIGURE 3
www.frontiersin.org

FIGURE 3. Mechanisms of nanoparticle delivery. Nanoparticles can be delivered directly to the lesion site by balloon angioplasty (A), they can be targeted using conjugated antibodies that target specific surface markers on the lesion (B), or they can passively diffuse into the lesion due to increased endothelial permeability (C).

Therapeutics for Nanoparticle-Mediated Delivery

Since atherosclerosis is a very complex disease, combinations of drugs or growth factors may be required for effective treatment. Therapeutics targeting inflammatory cells, SMC proliferation, thrombosis, and dysfunctional endothelial cells have all shown promise in pre-clinical or clinical studies. HMG Co-A reductase inhibitors (known as statins) are widely used for systemic prevention of atherosclerosis, due to their pleiotropic effects on cholesterol levels, SMC proliferation, inhibition of inflammation, and promotion of endothelial health (Liao, 2005). Statins have also been shown to stabilize and reverse advanced atherosclerotic plaques in animals, but only at high doses that are not approved for humans (Bea et al., 2002; Johnson et al., 2005). Thus, the targeted delivery of higher doses via nanoparticles may be able to reverse lesion progression without the harmful effects of systemic delivery (Winter et al., 2008; Zago et al., 2013; Duivenvoorden et al., 2014; Katsuki et al., 2014; Alaarg et al., 2017). A recent study compared the effects of simvastatin delivery via intravenously injected nanoparticles fabricated from Polyethylene glycol (PEG)-ylated polymeric micelles, high-density lipoproteins (HDL), and PEGylated lysosomes on advanced atherosclerotic lesions, with the goal of decreasing inflammation by reducing macrophage burden (Alaarg et al., 2017). They found that PEGylated polymeric micelles yielded greater reductions in macrophage burden in advanced atherosclerotic plaques. This may be due to their slower release of simvastatin and better ability to target macrophages than the other nanoparticle types. This highlights the importance of optimizing nanoparticle design and release kinetics for maximum drug effectiveness.

Other molecules that target inflammation have also shown promise in pre-clinical studies, including interleukin 10 (IL-10) (Kamaly et al., 2016), steroids (Lobatto et al., 2015), and the proresolving peptide Ac2-26, a protein that mimics the effects of annexin 1 (Fredman et al., 2015). van der Valk et al. (2015) tested IV injected, passive targeting, prednisolone-loaded liposomal nanoparticles in a clinical study. While the nanoparticles had shown promise in previous rabbit models (Lobatto et al., 2015), they did not reduce inflammation in human lesions (van der Valk et al., 2015). This may be due to the short-term (10 days) nature of the study. The authors were also unable to verify that the nanoparticles were accumulating in lesions. In the future, nanoparticles that can be imaged may enable lesions to be both visualized and treated at the same time, and alleviate uncertainty over whether they are reaching their target. Additionally, the lack of observed benefit in clinical studies may be due to differences in atherosclerotic plaque formation in animals compared to humans. Rabbits, like many small animals, will not form plaque without a high-cholesterol diet. This results in much higher cholesterol levels than are typically seen in humans, and lesions that are more fatty and inflammatory that human atherosclerotic plaques (Cullen et al., 2003; Yanni, 2004). Mice are also commonly used, but require genetic manipulation in addition to diet changes to develop plaque lesions (Calara et al., 2001). Because small animals have similarly sized cells to humans but much smaller blood vessels, there are fewer cells involved in vessel function and plaque formation, which may affect disease progression. These animals also have considerable genetic homogeneity compared to humans, making it challenging to replicate the large patient-to-patient variability typically seen in humans (Cullen et al., 2003).

Chemotherapeutic agents have been studied as potential atherosclerosis treatments due to their potent anti-proliferative effects. Intravenously injected lipid nanoparticles loaded with the drug carmustine successfully decreased lesion area by reducing SMC proliferation, secretion of inflammatory factors, and macrophage burden in rabbits (Daminelli et al., 2016). Shiozaki et al. (2016) recently published a pilot clinical study where cholesterol-rich non-protein nano-emulsion (LDE) particles, which resemble low-density lipoproteins, were loaded with paclitaxel oleate. When delivered systemically via intravenous injection, the nanoparticles were able to reduce total plaque in patients, though the difference was not significant (Shiozaki et al., 2016).

Due of the complexity of atherosclerosis, the release of multiple factors with different targets may provide a greater benefit than one factor alone. Zhu et al. (2017) designed bilayered poly(lactide-co-glycolide)/poly(vinyl alcohol) (PLGA/PVA) nanoparticles loaded with VEGF-encoding plasmid DNA and paclitaxel. Plasmid DNA encoding genes for growth factors and other proteins can enable upregulated production of a particular molecule without additional stimuli. This system is designed to first increase VEGF production and heal the endothelial layer, and then inhibit SMC proliferation. Results were promising in a rabbit model, where histological analysis showed endothelialization and decreased stenosis after 28 days in animals treated with the bilayered nanoparticles, delivered via angioplasty balloon (Zhu et al., 2017). Using plasmids to induce growth factor production in cells may also help address concerns over growth factor stability and reduce the risk of potentially toxic growth factor burst releases. SiRNA and microRNA are also potential therapeutics for treating atherosclerosis. Ma et al. (2016) utilized intravenously injected polymer nanoparticles to deliver microRNA to enhance endothelial function and reduce lesion size in a mouse model. Others have tested nanoparticle-mediated siRNA delivery, with some success (Li et al., 2010; Leuschner et al., 2011). For example, Leuschner et al. (2011) used siRNA to prevent macrophage accumulation in atherosclerotic plaques.

Overall, nanoparticles have great potential for targeted delivery of therapeutics to atherosclerotic lesions. A wide range of materials, therapeutics, and molecular targets have been investigated, although very few have advanced to clinical trials. Therapeutics and nanoparticle properties discussed in this section are summarized in Tables 2 and 3. With such a complex disease, it is likely that multi-bioactive factor approaches will be needed to effectively heal atherosclerotic lesions, as single bioactive factor approaches may be ineffective. Moving forward, issues such as consistency of nanoparticle fabrication, optimization of nanoparticle targeting and bioactive molecule release, premature nanoparticle clearance from the body, and the potentially harmful effects of some nanoparticles must also be addressed before these treatments become clinically available.

TABLE 2
www.frontiersin.org

TABLE 2. Molecules delivered for aneurysm repair.

TABLE 3
www.frontiersin.org

TABLE 3. Nanoparticle properties.

Targeted Bioactive Molecule Delivery for Aneurysm Repair

Bioactive Factor-Eluting Aneurysm Coils

One treatment method for saccular aneurysms is to “clip” or tie off the aneurysm, to prevent blood from flowing into the aneurysm to cause further dilation or bursting. Aneurysm coiling, where a coil is inserted through the vasculature and into the dilation, is often preferred over clipping because it is a much less invasive procedure, and some aneurysms in the brain may not be accessible for clipping. However, there is a risk that over time blood may leak back into the dilation, causing a secondary aneurysm. To address this, bioactive coils fabricated from degradable polymers, such as PLGA, have been developed. As bioactive polymers degrade, they trigger an inflammatory response and tissue remodeling, which causes new tissue to fill in and “heal” the aneurysm. This approach successfully reduced the rate of residual aneurysms, although it did not improve the overall rate of late aneurysm rupture or reintervention (Broeders et al., 2016).

Bioactive factor-eluting coils may be able to further enhance tissue healing. Growth factors such as VEGF may enhance clot organization and encourage endothelium formation across the aneurysm neck, preventing leakage into the coiled region (Abrahams et al., 2001; Ohyama et al., 2004). Fibroblast growth factor (FGF) is also well-established to promote wound healing and new tissue formation. Coils coated with VEGF or FGF have shown some success in animal studies (Abrahams et al., 2001; Matsumoto et al., 2003; Ohyama et al., 2004; Tsumoto et al., 2007). However, issues such as growth factor instability and suboptimal release kinetics prevented these systems from moving forward to clinical trials.

More recent approaches focus on developing more stable growth factor delivery systems. Wang et al. (2014) tested a coil coated with VEGF-loaded poly(D,L-lactide)-7co-(1,3-trimethylene carbonate), and achieved a sustained VEGF release curve over 25 days (Wang et al., 2014). However, it should be noted that in vitro release experiments do not account for the many complexities of the in vivo environment, including proteases, the inflammatory response, and other factors that may affect material degradation and molecule release rates. Coils coated with more stable molecules such as SEK-1005, a TGF-β inducing peptide known to promote wound healing, have also been studied. While this system accelerated aneurysm healing in rats, inconsistent growth factor loading was a problem (Sano et al., 2010). Hamada et al. (2014) developed a platinum coil with tenascin-C, a protein known to promote fibrosis, loaded in a gellan sulfate core. Gellan sulfate is a heparin-like molecule that strongly binds to tenascin-c, resulting in a slow, controlled release. Additionally, because the protein is released from the core, it avoids potentially harmful buildup at the coil-arterial interface (Toma et al., 2005; Miura et al., 2016). Pre-clinical trials showed improved tissue formation over the aneurysm neck and improved intra-aneurysmal clot organization, which may ultimately lead to improved tissue remodeling (Hamada et al., 2014; Miura et al., 2016). Recently, Gao et al. (2014) designed a coil with a silk-fibroin coating that eluted stromal-cell derived factor 1α (SDF-1α), which demonstrated a steady release of growth factor over 21 days as the coating degraded. In preliminary rat studies, they observed improved tissue growth within the aneurysmal region compared to uncoated coils (Gao et al., 2014).

While many different drugs and growth factors have potential for healing aneurysms, designing coils with optimal release kinetics, as with drug-eluting stents, is key. Delivering too much of a molecule in a short period of time, or not delivering enough, may have negative consequences. Thus, developing systems that can provide controlled, sustained release of stable therapeutics for enhancing clot organization and tissue growth is critical.

Nanoparticle Targeting for Aneurysm Repair

Unlike molecules delivered on aneurysm coils, which aim to “fill” existing saccular aneurysms with new tissue, MMP inhibitors may be effective at preventing elastin degradation and halting aneurysm growth. Specifically, doxycycline has been shown to reduce plasma MMP levels and inflammation of the vessel wall (Baxter et al., 2002; Lindeman et al., 2009). However, systemic delivery causes dose-dependent side effects (Baxter et al., 2002). The Ramamurthi group has investigated localized delivery of the MMP inhibitor doxycycline via PLGA nanoparticles. Nanoparticles were functionalized with a cationic amphiphile, which improved arterial uptake and enhanced MMP inhibitory activity (Sivaraman and Ramamurthi, 2013). They also tested nanoparticles loaded with smaller superparamagnetic iron oxide nanoparticles, in addition to doxycycline, to magnetically guide nanoparticles to the affected area (Sivaraman et al., 2017). So far, results from the above studies have shown promise in in vitro and ex vivo studies. Nosoudi et al. (2015) fabricated poly(D,L-lactide) nanoparticles for the delivery of the MMP inhibitor batimastat. Nanoparticles were conjugated with an elastin antibody that binds to degrading elastin, which may allow systemically delivered nanoparticles to target locations of aneurysm. The approach has shown promise in rats, where the intravenously injected nanoparticles were able to prevent aneurysm expansion (Nosoudi et al., 2015). In addition to MMP inhibitors, nanoparticle-mediated delivery of hyaluronan-oligomers and of transforming growth factor β1 (TGF-β1) have also shown promise as therapeutics for increasing elastin synthesis in vitro (Sylvester et al., 2013; Venkataraman et al., 2016).

While the aforementioned systems are promising for targeting aneurysms, bioactive molecule delivery to the vascular wall may still be hindered by the presence of clots on the aneurysm intraluminal surface. Combining these approaches with other molecules such as tissue plasminogen activator, which allows for controlled fibrinolysis of clots, may enhance their effectiveness. Nanoparticle-mediated tissue plasminogen activator delivery has shown promise in vitro for this purpose (Sivaraman et al., 2016). Ultimately, a more comprehensive approach where nanoparticles can first carefully dissolve clots in the aneurysm, and then deliver MMP inhibitors to stabilize the aneurysm, may be necessary.

Targeted Delivery in Vascular Grafts

Non-degradable Synthetic Vascular Grafts

In severe cases of vascular disease, the affected area may need to be replaced altogether with a bypass graft. Permanent synthetic grafts have been widely used for replacing large diameter blood vessels, in cases of both stenosis and aneurysm. They have excellent mechanical strength and are relatively simple and cost effective to produce on a large scale. However, in small diameter (<6 mm diameter) vessels, synthetic grafts have an extremely high risk of thrombosis and restenosis (Chard et al., 1987; Shah et al., 2005; Hadinata et al., 2009). This may be due to incomplete endothelialization, which is crucial for reducing the risk of these complications (Allen et al., 1984). The surface properties of commonly used synthetic materials can make these grafts challenging to endothelialize (Moby et al., 2007). Incorporating heparin or growth factors onto graft surfaces may help address this challenge.

Heparinized Synthetic Grafts

Synthetic grafts with incorporated heparin have been tested as early as the 1980s (Noishiki et al., 1986; Nojiri et al., 1987). Exogenous heparin is well known to inhibit SMC proliferation, prevent thrombosis, and encourage endothelialization, though high systemic doses can be harmful (O’Donnell, 2012). Thus, targeted delivery of heparin by immobilization on synthetic grafts, particularly those fabricated from ePTFE or Dacron, has been widely studied. Over the years, heparinized grafts have been tested clinically for infrainguinal (Walluscheck et al., 2005), femoropopliteal (Devine et al., 2001, Devine et al., 2004; Bosiers et al., 2006; Daenens et al., 2009; Lindholt et al., 2011), and aortic bypass grafting (Tsilimparis et al., 2015), and as arteriovenous shunts (Shemesh et al., 2015). Overall, trials have been successful, with patency rates comparable to native saphenous vein, and improved over non-heparinized synthetic grafts. An example illustrating this improvement is provided in Figure 4, which shows the luminal surface of a GORE graft with and without their CARMEDA BioActive Surface (CBAS® heparin surface) after 2 h of implantation in a canine carotid artery model (Biran and Pond, 2017). The graft without the heparin coating has a clear thrombotic occlusion, compared to the graft with the CBAS heparin surface, which does not have any apparent thromboses. In addition to its established effects, it may be possible that heparin traps circulating growth factors, which may further enhance endothelialization and improve patency rates.

FIGURE 4
www.frontiersin.org

FIGURE 4. Effect of heparin on synthetic graft thrombosis. A GORE ePTFE vascular graft with or without a CBAS heparin surface coating, following a 2-h implantation in a canine carotid model. Thrombosis is clearly visible in the graft without the CBAS heparin surface. Figure reprinted from (Biran and Pond, 2017) with permission from W. L. Gore and Associates.

Due to the success of these studies, some heparinized grafts, such as the GORE PROPATEN graft, are now commercially available for bypassing large diameter vessels and some smaller diameter lower limb vessels. There have been mixed reports concerning long term (5 years) patency rates compared to grafts without heparin, which may be due to different immobilization methods (Devine et al., 2004; Samson et al., 2016). Covalent immobilization techniques maintain heparin in its bioactive state tethered to the graft, with limited release over time (Larm et al., 1983). Other immobilization or coating methods may result in faster heparin release, limiting its long-term protective effects.

Growth Factor Delivery

Growth factors have been tested to enhance endothelialization of synthetic vascular grafts since the 1990s (Greisler et al., 1992; Gosselin et al., 1996; Doi and Matsuda, 1997). They can either be incorporated within coatings on the luminal surface of the graft, or immobilized directly to the graft surface. Coatings are more commonly used, as direct immobilization of growth factors onto synthetic surfaces can be challenging, and additional surface modifications may be required (Crombez et al., 2005). Fibrin and fibronectin are the most widely used coatings to incorporate growth factors, as these proteins alone directly bind to ECs, aiding in their adhesion (Zilla et al., 1989; Meinhart et al., 2005; Dahl et al., 2011; De Visscher et al., 2012).

Early studies incorporated FGF into fibrin glue coatings for ePTFE grafts. This appeared to enhance endothelialization in rabbits, though the potent effects of FGF on SMC proliferation also increased neointimal growth (Greisler et al., 1992). Later, growth factors more specific to ECs, such as VEGF, were tested. VEGF is well-established to attract ECs and stimulate EC proliferation (Ferrara and Devis-Smyth, 1997). When incorporated into a Matrigel coating, VEGF resulted in enhanced endothelialization, but also increased intimal hyperplasia in a rat model (Randone et al., 2005). Similar increases in neointimal growth were observed when VEGF was incorporated into fibrin-coated grafts implanted in pigs (Walpoth et al., 2007). This may be because VEGF can stimulate ECs to produce other growth factors, including FGF, that increase SMC proliferation (Randone et al., 2005). Thus, VEGF alone may not be an ideal growth factor for this application.

Stromal-cell derived factor-1α has been used to stimulate stem cell recruitment and accelerate healing. When implanted in sheep, grafts with SDF-1α incorporated into a fibronectin coating had less intimal growth compared to controls (De Visscher et al., 2012). Other growth factors may be effective for enhancing endothelialization and preventing intimal hyperplasia, but have been largely studied on decellularized native arteries rather than synthetic grafts, and are discussed in more detail in Section “Decellularized Grafts for Growth Factor Delivery” below. Overall, growth factor coatings have been less successful than heparin immobilization. It is likely that combinations of growth factors and other molecules will be needed to both enhance endothelialization and prevent stenosis.

Other Molecules for Enhanced Endothelialization

Antibodies specific to ECs may also be effective for enhancing EC adhesion to synthetic surfaces. CD133 and VEGF receptor-2 are both specific to endothelial progenitor cells (EPCs). Lu et al. (2013) incorporated CD133 antibodies into a collagen coating layered with heparin, and observed enhanced endothelialization in a porcine model (Lu et al., 2013). Grafts coated with VEGF receptor-2 antibodies have also shown promise, leading to increased adhesion of VEGF receptor-2-expressing cells in in vitro studies (Liebler et al., 2016). Sapienza et al. (2009) coated the luminal surface of grafts with antibodies against endogenous FGF, PDGF, and TGF-β1. The growth factors bind to these antibodies, which prevents them from activating local growth factor receptors and stimulating SMC proliferation. This resulted in less intimal hyperplasia in a 4 weeks pig study (Sapienza et al., 2009), though longer term studies are needed to ensure that the growth factor inhibition does not harm the endothelium. Additional approaches for enhancing EC adhesion on synthetic grafts are reviewed in (Melchiorri et al., 2013; Ren et al., 2015).

In addition to immobilization or incorporation within coatings, some molecules can be incorporated within synthetic grafts during fabrication. Ishii et al. (2008) incorporated sirolimus and heparin into polycarbonate-siloxane polyurethane during the fabrication process. These grafts showed increased endothelialization and reduced intimal growth compared to grafts with either drug alone in a rabbit model (Ishii et al., 2008).

The controlled release of heparin and other therapeutics has made synthetic vascular grafts a viable alternative for several bypass grafting applications. However, there have still not been any reports of synthetic grafts with acceptable patency rates for small diameter high-flow arteries such as the coronary artery. Further optimization of therapeutic agents used and their release kinetics may help address this need. However, mechanical properties also play a critical role in graft success, as compliance mismatch is well-established to trigger restenosis (Abbott et al., 1987). Utilizing growth factor release to stimulate endothelialization and tissue ingrowth, in addition to optimizing graft compliance may lead to higher patency rates.

Controlled Release From Tissue Engineered Blood Vessels

Tissue engineered blood vessels can be fabricated in a variety of ways. A common approach is to seed cells onto natural or synthetic polymer scaffolds and allow the construct to mature and remodel in a bioreactor (Niklason et al., 1999; Grassl et al., 2002). Alternatively, TEBVs can be fabricated via cellular self-assembly approaches, where constructs are fabricated entirely from cells and their secreted extracellular matrix (L’Heureux et al., 1998; Gwyther et al., 2011). While these approaches have had some success, many challenges remain, such as establishing a healthy, contractile SMC phenotype, optimizing graft strength and compliance, and achieving complete endothelialization. Localized and controlled bioactive factor delivery may be able to address some of these problems.

The goal of many tissue engineering strategies is for native tissue to ultimately replace the original synthetic or natural polymer construct. To do this, the scaffold degradation rate must be carefully engineered to match the rate of new tissue growth. Thus, depending on the system, growth factors released in TEBVs may be designed to mature the graft and enhance cell proliferation, matrix deposition, or cell differentiation, compared to drug-eluting devices discussed earlier, which are predominantly designed to prevent SMC proliferation and new tissue growth. Therefore, it is important to consider how different types of TEBVs will be integrated with host tissue when designing controlled release systems.

Decellularized Grafts for Growth Factor Delivery

Decellularized allogeneic vessels have had some clinical success and are commercially available as alternatives to synthetic grafts for small diameter vessels when autologous grafts are not available (O’Banion et al., 2016). However, these grafts still have low patency rates (56% primary patency at 1 year for infrapopliteal bypass), primarily due to thrombosis (Randon et al., 2010). As with synthetic vascular grafts, molecules such as heparin may be used to enhance endothelialization and reduce the risk of thrombosis and restenosis (Conklin et al., 2002; Wang et al., 2007; Zhou et al., 2012; Dimitrievska et al., 2015). Growth factors immobilized on graft surfaces have also been studied (Conklin et al., 2004; Zeng et al., 2010; Zeng et al., 2012). Specifically, grafts with immobilized brain-derived neurotrophic factors (Zeng et al., 2012) and nerve growth factor (Zeng et al., 2010) increased endothelial progenitor cell recruitment and improved endothelialization and patency in rat models. While growth factor coated decellularized allogeneic blood vessels are a promising alternative as small-diameter bypass grafts, their limited availability may ultimately prevent widespread use.

Degradable Electrospun Polymer Scaffolds

Degradable polymer scaffolds can enable highly tuned release of growth factors and other therapeutics. Polymers can be designed and fabricated with customizable degradation rates, which play a major role in release kinetics. Growth factor incorporation in degradable polymeric TEBVs has been mainly limited to electrospinning approaches. Other types of degradable TEBV scaffolds may also be ideal for this application, but have been largely unexplored. These are restricted to a small number of studies where growth factors were tethered to degradable polymer surfaces, rather than directly incorporated within the scaffolds (Edlund et al., 2011; Melchiorri et al., 2015). In this section, we will focus on molecules that are directly incorporated within electrospun TEBVs during fabrication, rather than tethered onto their surface.

Electrospinning is a process where an electric current is applied to a polymer solution, which forms thin micro- or nano-fibers that accumulate to create scaffold. Electrospun scaffolds are advantageous because they have a porous structure that provides a high surface area to volume ratio. This allows for potential sustained delivery, as encased molecules must first diffuse out of the polymer fiber, and then through the pores in the graft. With electrospinning, parameters that may affect bioactive molecule release, such as polymer composition, fiber diameter, and pore size, can be easily tuned by adjusting manufacturing parameters.

There are several methods for incorporating molecules within electrospun fibers, reviewed in Rychter et al. (2017) and summarized schematically in Figure 5. Direct blending is used when the polymer and growth factor have similar solubility. The polymer and therapeutic are combined prior to electrospinning to form one solution, which is advantageous due to simplicity in manufacturing. However, this may result in a high initial burst release, as drugs and growth factors tend to be located predominantly on the fiber surface (Kim et al., 2004). With emulsion electrospinning, a typically aqueous solution of growth factor is emulsified in a solution of polymer, which leads to droplets of growth factor solution becoming encapsulated within a polymer shell after electrospinning. Coaxial electrospinning utilizes two different pumps to enable electrospinning of two different solutions together to create core-shell fibers, where a growth factor solution core is contained in a polymer shell (Rychter et al., 2017).

FIGURE 5
www.frontiersin.org

FIGURE 5. Techniques for incorporating bioactive molecules within electrospun grafts. Molecules can be tethered to the material after electrospinning. With coaxial electrospinning, the material and bioactive substance are combined during the electrospinning process, while being dispensed from two separate syringes. Alternatively, with emulsion electrospinning or direct blending a solution of bioactive molecules is mixed with the material prior to electrospinning.

Electrospinning has been used to incorporate a wide range of molecules into vascular grafts (summarized in Table 4). Many of these designs have advanced to pre-clinical testing, including grafts eluting VEGF to enhance endothelialization (Zhang et al., 2013), heparin to prevent thrombosis (Huang et al., 2013; Yao et al., 2014; Spadaccio et al., 2016), platelet-derived growth factor (PDGF) to encourage SMC ingrowth (Zhang et al., 2013), SDF-1α to recruit progenitor cells (Yu et al., 2012), paclitaxel to inhibit restenosis (Innocente et al., 2009), and antibiotics to prevent infection (Liu et al., 2015). Other molecules, such as steroids (Chen et al., 2015) and anti-thrombotic drugs (Punnakitikashem et al., 2014) have shown promise in in vitro studies for decreasing inflammation and thrombosis, but have not progressed to in vivo testing.

TABLE 4
www.frontiersin.org

TABLE 4. Molecules delivered in synthetic and tissue engineered vascular grafts.

Grafts with incorporated heparin have shown promise in canine studies. Wang et al. (2013) incorporated heparin into poly(L-lactide-co-epsilon-caprolactone) electrospun grafts by coaxial electrospinning. With the addition of a pre-endothelialization step, they achieved an 89% patency rate when heparin-eluting grafts were implanted in a canine femoral artery for 24 weeks (Wang et al., 2013). However, grafts that were not pre-endothelialized had very poor patency, even with incorporated heparin (Wu et al., 2015).

As with other drug delivery applications, single therapeutic approaches are often unsuccessful. Dual delivery approaches may be more effective for addressing the multiple challenges associated with implanting TEBVs. Zhang et al. (2013) developed a two-layer electrospun vascular graft, with an inner VEGF-loaded layer to induce endothelialization, and an outer PDGF-loaded layer to stimulate SMC infiltration and new tissue growth. Grafts remained patent for 4 weeks after implantation in rabbit carotid arteries (Zhang et al., 2013). A similar system described in Campagnolo et al. (2016) incorporated an osteopontin-derived peptide in the luminal side to increase EC adhesion, and a heparin-binding peptide on the abluminal side to trap secreted VEGF and further enhance EC migration and proliferation. In vitro tests showed promising increases in EC adhesion, although this system has not yet been tested in vivo (Campagnolo et al., 2016).

In the future, customizing the delivery of therapeutics for individual patients may also help improve graft success, as different patients may experience different rates of healing and endothelialization. Wang et al. (2015) developed an enzyme-functionalized vascular graft that locally produced nitric oxide (NO) when a prodrug was administered systemically in rats. After 30 days, explanted NO-producing grafts had enhanced function, endothelialization, and reduced platelet adhesion compared to grafts that did not produce NO (Wang et al., 2015). This system may allow for the further tuning of molecule delivery, as the molecule can locally be produced “on demand” only when the patient needs it.

Overall, electrospinning is a well-suited graft fabrication technique to incorporate a variety of different growth factors and therapeutics into polymer scaffolds with highly tunable release kinetics. However, while pre-clinical trials have been promising, most still exhibit high stenosis rates that have prevented grafts from moving forward to clinical trials. Optimizing delivery of therapeutics may improve success. As with permanent synthetic grafts, therapeutic delivery in combination with altering other graft properties, such as compliance, may be critical for improving overall patency. Additionally, parameters such as pore size and fiber diameter may need to be optimized to achieve adequate cellular infiltration and tissue ingrowth. Electrospun grafts are reviewed in greater detail in Rychter et al. (2017).

Microsphere-Mediated Growth Factor Delivery in Engineered Vascular Tissue

Microsphere (MS)-mediated growth factor delivery has been used for years to mature and differentiate many engineered tissues, including cartilage (Solorio et al., 2010), bone (Wang et al., 2009), and stem cell aggregates (Carpenedo et al., 2009; Solorio et al., 2010; Bratt-Leal et al., 2013). MS incorporation alone can increase tissue strength (Solorio et al., 2012b; Dikina et al., 2015), oxygen diffusion (Hayashi and Tabata, 2011; Tajima and Tabata, 2013), cell viability (Garcia Cruz et al., 2013; Tajima and Tabata, 2013), and uniformity of matrix deposition (Solorio et al., 2012a). However, their application in vascular tissue engineering has been limited. Others have incorporated gelatin MS into cell spheroids, which were fused into vascular tissue, but the MS primarily served to stabilize the construct and were not used for growth factor delivery (Twal et al., 2014). Our group has demonstrated that MS loaded with TGF-β1 can be used to increase SMC contractile protein expression within self-assembled SMC rings (Strobel et al., 2017). This approach may be well-suited for applications where systemic or exogenous delivery of a growth factors may be harmful or not possible, or for thick, high cell density engineered tissues where growth factors cannot diffuse through the entire construct.

Future of Growth Factor Delivery in TEBVs

There is great potential for growth factors to be incorporated into other systems, such as TEBVs fabricated from hydrogels or other polymer scaffolds, which have yet to be explored. Incorporation within scaffolds may help overcome diffusion limitations and result in more uniform treatment than exogenous growth factor delivery. It may also allow for continuous delivery of growth factors after TEBV implantation, when exogenous or systemic delivery is not feasible. Many different types of molecules may be utilized, depending on the application. As discussed above, cytokines for EC recruitment have proven essential for preventing thrombosis and intimal hyperplasia. Other growth factors such as PDGF and FGF may be able to stimulate new tissue formation in degrading polymer grafts, and TGF-β1 may be used to differentiate SMCs and drive TEBV maturation.

Tissue maturation may further be enhanced by adjustments to growth factor release kinetics. Release of multiple growth factors sequentially may be beneficial for vascular tissue engineering. Gong and Niklason (2008) developed an optimized procedure for fabricating TEBVs by treating them in vitro with exogenous PDGF for 4 weeks to stimulate new tissue growth, and then TGF-β1 for 4 weeks to promote differentiation. This sequential delivery could also be obtained by designing biomaterials for controlled dual-delivery, an approach that is already being used to create microvasculatures within other engineered tissues (Chen et al., 2007; Freeman and Cohen, 2009).

Delayed release of anti-inflammatory molecules days or weeks after TEBV implantation is another potential application of controlled release. While the inflammatory response may be critical immediately following implantation, delayed release of anti-inflammatory molecules may prevent problems such as intimal hyperplasia from occurring later (Washington and Bashur, 2017).

Spatiotemporal control of the release of multiple growth factors may also be applied to modeling focal vascular diseases. Because many vascular diseases such as atherosclerosis, intimal hyperplasia, and aneurysm affect only one region of the vessel, delivering growth factors or other molecules specifically within a focal region within TEBVs may enable the creation of such models. This could potentially be accomplished with modular TEBV approaches and controlled release systems (Strobel et al., 2018). Spatially controlled release may also be advantageous for culturing and maintaining distinct tissue phenotypes in multi-tissue constructs such as trachea, which have alternating smooth muscle and cartilage regions (Dikina et al., 2018).

Regulatory Challenges

There are many challenges when designing an effective drug-eluting medical device or tissue engineered construct. In addition to design challenges, regulatory approval of these products is a major consideration. Medical devices, drugs, and biologics are all regulated by the Food and Drug Administration in the United States, to ensure safety and efficacy of any new product. Drug-eluting stents pose a regulatory challenge because they contain both a device and a drug, making them a combination product. However, they have now been in use for many years, and regulatory guidelines are well-established [described in detail in Food and Drug Administration [FDA] (2008)]. Because there are many approved drug-eluting stent designs, and they often utilize already approved drugs, new designs may have a more clear pathway to approval, although extensive in vitro, pre-clinical, and clinical studies are still required. However, experimental designs and therapeutics, such as siRNA eluting stents, may be considered new drugs and require even more thorough safety and efficacy testing.

The wide range of nanoparticle designs can make them more challenging to regulate. For example, size may play a critical role in the safety of some nanoparticle-based therapeutics, but have no effect on the safety of others, depending on the material and delivery and targeting mechanisms. Nanoparticles are usually regulated under the same standards as other drugs. However, because there may be additional concerns about toxicity, clearance, and biodistribution, some additional recommendations are in place [detailed in Food and Drug Administration [FDA] (2017)]. The largest barrier to approval is the often limited understanding of nanoparticle pharmacokinetics. Improvements in pharmacokinetic modeling may help accelerate the approval of these therapies in the future. Regulation of nanoparticles is reviewed in detail in Narang et al. (2013).

Tissue engineered blood vessels provide a unique regulatory challenge, because they are a relatively new technology that combines the regulatory umbrellas of biologics, tissues, and devices. While ASTM and ISO standards exist for testing synthetic vascular grafts (American National Standard [ANS], 2010) and some other tissue engineered products, none specifically cover the characterization and manufacturing of TEBVs (Lee et al., 2010). With TEBVs, additional factors need to be considered such as how cells will affect scaffold properties over time. Because cells, materials, scaffolds, and eluted molecules are produced separately, quality control testing may need to be performed both before and after TEBV fabrication. Deciding at which timepoints during TEBV maturation and remodeling that they should be tested can also be a challenge (Lee et al., 2010). As more TEBVs move forward into clinical trials, more regulatory guidelines will be established to help address these challenges.

Summary and Unmet Challenges

Localized bioactive molecule delivery has enormous potential for more effective and safe treatment of cardiovascular diseases than systemic treatments. Drug-eluting stents are already widely used clinically and have shown great success. Other systems, such as bioactive molecule-eluting nanoparticles and aneurysm coils, still have some challenges to overcome before they can be used clinically. While these fields have made tremendous progress, there is only a limited ability to predict how effective new designs will be in vivo. While computational modeling has improved our ability to predict release curves, these models are still highly limited. Patient-to-patient variability in the inflammatory and immune responses, thrombus formation, healing, and re-endothelialization makes this an exceptionally challenging problem, as these factors can affect material degradation, molecule release, and diffusion into the tissue. In the future, more advanced models may further improve our ability to streamline drug-eluting medical device design and maximize the patient benefit of these products. Existing drug-release models are often based on animal studies, which may not translate to humans. It is possible that TEBVs may in the future be used to better mimic the human in vivo environment in vitro, to create a more realistic system for modeling drug release profiles. TEBVs may also allow for the fabrication of patient-specific disease models, which may further improve our ability to account for patient-to-patient variability.

Combining nanoparticle and drug-eluting stent approaches may in the future allow for sequential delivery of multiple factors, allowing for more comprehensive, customized treatments. The enormous number of nanoparticle systems and drug-eluting stents in development may ultimately provide physicians with a wide range of options, enabling them to customize targeted drug delivery for each individual patient’s needs. Future work in the field may focus on combining several technologies to deliver multiple therapeutics sequentially, and to allow for such customization.

Vascular bypass grafts have made significant progress as alternatives to autologous grafting for large and medium blood vessel bypass procedures, but progress has been slow for small diameter applications. TEBVs for coronary artery bypass grafting have achieved success in pre-clinical studies, but have yet to be applied clinically. Some of the challenges currently facing the field include optimization and in vivo measurement of drug release kinetics, the need for multi-drug approaches with differing release profiles, problematic compliance mismatch between vascular grafts and native vessels, and insufficient tissue ingrowth into vascular grafts and TEBVs. As with other vascular interventions, future work in tissue engineering may focus on optimizing biomaterials to release multiple growth factors or other molecules, to fabricate and mature tissue into biomimetic grafts.

Author Contributions

HS is the primary author. EQ created the figures and assisted with literature searches. EA revised the structure and content, and edited the final draft. MR advised HS and EQ on structure and content, and edited the manuscript.

Funding

This work was supported by NSF IGERT DGE 1144804 (MR and HS), 1R01 EB023907-01 (EA, MR, and HS), NIH R15 HL137197 (MR and HS), and EQ was supported on T32 GM107000 from the National Institute of General Medicine, NIH awarded to the UMMS MSTP program.

Conflict of Interest Statement

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Acknowledgments

The authors gratefully acknowledge David Dolivo for his review and feedback on the manuscript.

References

Abbott, W. M., Megerman, J., Hasson, J. E., L’italien, G., and Warnock, D. F. (1987). Effect of compliance mismatch on vascular graft patency. J. Vasc. Surg. 5, 376–382. doi: 10.1016/0741-5214(87)90148-0

CrossRef Full Text | Google Scholar

Abizaid, A., Costa, R. A., Schofer, J., Ormiston, J., Maeng, M., Witzenbichler, B., et al. (2016). Serial multimodality imaging and 2-year clinical outcomes of the novel DESolve novolimus-eluting bioresorbable coronary scaffold system for the treatment of single de novo coronary lesions. JACC Cardiovasc. Interv. 9, 565–574. doi: 10.1016/j.jcin.2015.12.004

PubMed Abstract | CrossRef Full Text | Google Scholar

Abrahams, J. M., Forman, M. S., Grady, M. S., and Diamond, S. L. (2001). Delivery of human vascular endothelial growth factor with platinum coils enhances wall thickening and coil impregnation in a rat aneurysm model. AJNR Am. J. Neuroradiol. 22, 1410–1417.

PubMed Abstract | Google Scholar

Acharya, G., and Park, K. (2006). Mechanisms of controlled drug release from drug-eluting stents. Adv. Drug Deliv. Rev. 58, 387–401. doi: 10.1016/j.addr.2006.01.016

PubMed Abstract | CrossRef Full Text | Google Scholar

Adeel, M. Y., and Sharif, F. (2016). Advances in stent-mediated gene delivery. Expert Opin. Drug Deliv. 13, 465–468. doi: 10.1517/17425247.2016.1144589

PubMed Abstract | CrossRef Full Text | Google Scholar

Akinapelli, A., Chen, J. P., Roy, K., Donnelly, J., Dawkins, K., Huibregtse, B., et al. (2017). Current state of bioabsorbable polymer-coated drug-eluting stents. Curr. Cardiol. Rev. 13, 139–154.

PubMed Abstract | Google Scholar

Alaarg, A., Senders, M. L., Varela-Moreira, A., Pérez-Medina, C., Zhao, Y., Tang, J., et al. (2017). A systematic comparison of clinically viable nanomedicines targeting HMG-CoA reductase in inflammatory atherosclerosis. J. Control. Release 262, 47–57. doi: 10.1016/j.jconrel.2017.07.013

PubMed Abstract | CrossRef Full Text | Google Scholar

Allen, B. T., Long, J. A., Clark, R. E., Sicard, G. A., Hopkins, K. T., and Welch, M. J. (1984). Influence of endothelial cell seeding on platelet deposition and patency in small-diameter Dacron arterial grafts. J. Vasc. Surg. 1, 224–233. doi: 10.1016/0741-5214(84)90201-5

CrossRef Full Text | Google Scholar

American National Standard [ANS] (2010). “ANSI/AAMI/ISO 7198: 1998/2001/(R)2010 Cardiovascular implants- tubular prosthesis”, in: American National Standard, ed. A.F.T.a.O.M. Instrumentation (Washington, DC: American National Standard).

Google Scholar

Axel, D. I., Kunert, W., Goggelmann, C., Oberhoff, M., Herdeg, C., Kuttner, A., et al. (1997). Paclitaxel inhibits arterial smooth muscle cell proliferation and migration in vitro and in vivo using local drug delivery. Circulation 96, 636–645. doi: 10.1161/01.CIR.96.2.636

PubMed Abstract | CrossRef Full Text | Google Scholar

Balakrishnan, B., Dooley, J. F., Kopia, G., and Edelman, E. R. (2007). Intravascular drug release kinetics dictate arterial drug deposition, retention, and distribution. J. Control. Release 123, 100–108. doi: 10.1016/j.jconrel.2007.06.025

PubMed Abstract | CrossRef Full Text | Google Scholar

Baxter, B. T., Pearce, W. H., Waltke, E. A., Littooy, F. N., Hallett, J. W., Kent, K. C., et al. (2002). Prolonged administration of doxycycline in patients with small asymptomatic abdominal aortic aneurysms: report of a prospective (Phase II) multicenter study. J. Vasc. Surg. 36, 1–12. doi: 10.1067/mva.2002.125018

PubMed Abstract | CrossRef Full Text | Google Scholar

Bea, F., Blessing, E., Bennett, B., Levitz, M., Wallace, E. P., and Rosenfeld, M. E. (2002). Simvastatin promotes atherosclerotic plaque stability in ApoE-deficient mice independently of lipid lowering. Arterioscler. Thromb. Vasc. Biol. 22, 1832–1837. doi: 10.1161/01.ATV.0000036081.01231.16

PubMed Abstract | CrossRef Full Text | Google Scholar

Biran, R., and Pond, D. (2017). Heparin coatings for improving blood compatibility of medical devices. Adv. Drug Deliv. Rev. 112, 12–23. doi: 10.1016/j.addr.2016.12.002

PubMed Abstract | CrossRef Full Text | Google Scholar

Blanco, E., Shen, H., and Ferrari, M. (2015). Principles of nanoparticle design for overcoming biological barriers to drug delivery. Nat. Biotechnol. 33, 941–951. doi: 10.1038/nbt.3330

PubMed Abstract | CrossRef Full Text | Google Scholar

Bosiers, M., Deloose, K., Verbist, J., Schroe, H., Lauwers, G., Lansink, W., et al. (2006). Heparin-bonded expanded polytetrafluoroethylene vascular graft for femoropopliteal and femorocrural bypass grafting: 1-year results. J. Vasc. Surg. 43, 313–318; discussion 318–319. doi: 10.1016/j.jvs.2005.10.037

PubMed Abstract | CrossRef Full Text | Google Scholar

Bowen, P. K., Shearier, E. R., Zhao, S., Guillory, R. J. II, Zhao, F., Goldman, J., et al. (2016). Biodegradable metals for cardiovascular stents: from clinical concerns to recent Zn-alloys. Adv. Healthc. Mater. 5, 1121–1140. doi: 10.1002/adhm.201501019

PubMed Abstract | CrossRef Full Text | Google Scholar

Bozsak, F., Chomaz, J. M., and Barakat, A. I. (2014). Modeling the transport of drugs eluted from stents: physical phenomena driving drug distribution in the arterial wall. Biomech. Model. Mechanobiol. 13, 327–347. doi: 10.1007/s10237-013-0546-4

PubMed Abstract | CrossRef Full Text | Google Scholar

Bozsak, F., Gonzalez-Rodriguez, D., Sternberger, Z., Belitz, P., Bewley, T., Chomaz, J. M., et al. (2015). Optimization of drug delivery by drug-eluting stents. PLoS One 10:e0130182. doi: 10.1371/journal.pone.0130182

PubMed Abstract | CrossRef Full Text | Google Scholar

Brannon-Peppas, L., and Blanchette, J. O. (2012). Nanoparticle and targeted systems for cancer therapy. Adv. Drug Deliv. Rev. 64, 206–212. doi: 10.1016/j.addr.2012.09.033

CrossRef Full Text | Google Scholar

Bratt-Leal, A. M., Nguyen, A. H., Hammersmith, K. A., Singh, A., and Mcdevitt, T. C. (2013). A microparticle approach to morphogen delivery within pluripotent stem cell aggregates. Biomaterials 34, 7227–7235. doi: 10.1016/j.biomaterials.2013.05.079

PubMed Abstract | CrossRef Full Text | Google Scholar

Broeders, J. A., Ahmed Ali, U., Molyneux, A. J., Poncyljusz, W., Raymond, J., White, P. M., et al. (2016). Bioactive versus bare platinum coils for the endovascular treatment of intracranial aneurysms: systematic review and meta-analysis of randomized clinical trials. J. Neurointerv. Surg. 8, 898–908. doi: 10.1136/neurintsurg-2015-011881

PubMed Abstract | CrossRef Full Text | Google Scholar

Byrne, R. A., Neumann, F.-J., Mehilli, J., Pinieck, S., Wolff, B., Tiroch, K., et al. (2013). Paclitaxel-eluting balloons, paclitaxel-eluting stents, and balloon angioplasty in patients with restenosis after implantation of a drug-eluting stent (ISAR-DESIRE 3): a randomised, open-label trial. Lancet 381, 461–467. doi: 10.1016/S0140-6736(12)61964-3

PubMed Abstract | CrossRef Full Text | Google Scholar

Calara, F., Silvestre, M., Casanada, F., Yuan, N., Napoli, C., and Palinski, W. (2001). Spontaneous plaque rupture and secondary thrombosis in apolipoprotein E-deficient and LDL receptor-deficient mice. J. Pathol. 195, 257–263. doi: 10.1002/path.915

PubMed Abstract | CrossRef Full Text | Google Scholar

Campagnolo, P., Gormley, A. J., Chow, L. W., Guex, A. G., Parmar, P. A., Puetzer, J. L., et al. (2016). Pericyte seeded dual peptide scaffold with improved endothelialization for vascular graft tissue engineering. Adv. Healthc. Mater. 5, 3046–3055. doi: 10.1002/adhm.201600699

PubMed Abstract | CrossRef Full Text | Google Scholar

Carpenedo, R. L., Bratt-Leal, A. M., Marklein, R. A., Seaman, S. A., Bowen, N. J., Mcdonald, J. F., et al. (2009). Homogeneous and organized differentiation within embryoid bodies induced by microsphere-mediated delivery of small molecules. Biomaterials 30, 2507–2515. doi: 10.1016/j.biomaterials.2009.01.007

PubMed Abstract | CrossRef Full Text | Google Scholar

Carrie, D., Berland, J., Verheye, S., Hauptmann, K. E., Vrolix, M., Violini, R., et al. (2012). A multicenter randomized trial comparing amphilimus- with paclitaxel-eluting stents in de novo native coronary artery lesions. J. Am. Coll. Cardiol. 59, 1371–1376. doi: 10.1016/j.jacc.2011.12.009

PubMed Abstract | CrossRef Full Text | Google Scholar

Chard, R. B., Johnson, D. C., Nunn, G. R., and Cartmill, T. B. (1987). Aorta-coronary bypass grafting with polytetrafluoroethylene conduits. Early and late outcome in eight patients. J. Thorac. Cardiovasc. Surg. 94, 132–134.

PubMed Abstract | Google Scholar

Che, H.-L., Bae, I.-H., Lim, K. S., Song, I. T., Lee, H., Lee, D., et al. (2016). Therapeutic effect of Akt1 siRNA nanoparticle eluting coronary stent on suppression of post-angioplasty restenosis. J. Biomed. Nanotechnol. 12, 1211–1222. doi: 10.1166/jbn.2016.2255

PubMed Abstract | CrossRef Full Text | Google Scholar

Chen, M. S., John, J. M., Chew, D. P., Lee, D. S., Ellis, S. G., and Bhatt, D. L. (2006). Bare metal stent restenosis is not a benign clinical entity. Am. Heart J. 151, 1260–1264. doi: 10.1016/j.ahj.2005.08.011

PubMed Abstract | CrossRef Full Text | Google Scholar

Chen, R. R., Silva, E. A., Yuen, W. W., and Mooney, D. J. (2007). Spatio-temporal VEGF and PDGF delivery patterns blood vessel formation and maturation. Pharm. Res. 24, 258–264. doi: 10.1007/s11095-006-9173-4

PubMed Abstract | CrossRef Full Text | Google Scholar

Chen, W., Li, D., Ei-Shanshory, A., El-Newehy, M., Ei-Hamshary, H. A., Al-Deyab, S. S., et al. (2015). Dexamethasone loaded core-shell SF/PEO nanofibers via green electrospinning reduced endothelial cells inflammatory damage. Colloids Surf. B Biointerfaces 126, 561–568. doi: 10.1016/j.colsurfb.2014.09.016

PubMed Abstract | CrossRef Full Text | Google Scholar

Cho, I. -H., and Park, S. (2017). Preparation of a microporous polyurethane film with negative surface charge for siRNA delivery via stent. Int. J. Polym. Sci. 2017:2841682. doi: 10.1155/2017/2841682

CrossRef Full Text | Google Scholar

Chorny, M., Fishbein, I., Alferiev, I., and Levy, R. J. (2009). Magnetically responsive biodegradable nanoparticles enhance adenoviral gene transfer in cultured smooth muscle and endothelial cells. Mol. Pharm. 6, 1380–1387. doi: 10.1021/mp900017m

PubMed Abstract | CrossRef Full Text | Google Scholar

Colombo, A., Drzewiecki, J., Banning, A., Grube, E., Hauptmann, K., Silber, S., et al. (2003). Randomized study to assess the effectiveness of slow- and moderate-release polymer-based paclitaxel-eluting stents for coronary artery lesions. Circulation 108, 788–794. doi: 10.1161/01.CIR.0000086926.62288.A6

PubMed Abstract | CrossRef Full Text | Google Scholar

Conklin, B. S., Richter, E. R., Kreutziger, K. L., Zhong, D.-S., and Chen, C. (2002). Development and evaluation of a novel decellularized vascular xenograft. Med. Eng. Phys. 24, 173–183. doi: 10.1016/S1350-4533(02)00010-3

PubMed Abstract | CrossRef Full Text | Google Scholar

Conklin, B. S., Wu, H., Lin, P. H., Lumsden, A. B., and Chen, C. (2004). Basic fibroblast growth factor coating and endothelial cell seeding of a decellularized heparin-coated vascular graft. Artif. Organs 28, 668–675. doi: 10.1111/j.1525-1594.2004.00062.x

PubMed Abstract | CrossRef Full Text | Google Scholar

Costa, J. R. Jr., Abizaid, A., Costa, R., Feres, F., Tanajura, L. F., Abizaid, A., et al. (2009). 1-year results of the hydroxyapatite polymer-free sirolimus-eluting stent for the treatment of single de novo coronary lesions: the VESTASYNC I trial. JACC Cardiovasc. Interv. 2, 422–427. doi: 10.1016/j.jcin.2009.02.009

PubMed Abstract | CrossRef Full Text | Google Scholar

Crombez, M., Chevallier, P., Gaudreault, R. C., Petitclerc, E., Mantovani, D., and Laroche, G. (2005). Improving arterial prosthesis neo-endothelialization: application of a proactive VEGF construct onto PTFE surfaces. Biomaterials 26, 7402–7409. doi: 10.1016/j.biomaterials.2005.05.051

PubMed Abstract | CrossRef Full Text | Google Scholar

Cullen, P., Baetta, R., Bellosta, S., Bernini, F., Chinetti, G., Cignarella, A., et al. (2003). Rupture of the atherosclerotic plaque: does a good animal model exist? Arterioscler. Thromb. Vasc. Biol. 23, 535–542. doi: 10.1161/01.ATV.0000060200.73623.F8

PubMed Abstract | CrossRef Full Text | Google Scholar

Daenens, K., Schepers, S., Fourneau, I., Houthoofd, S., and Nevelsteen, A. (2009). Heparin-bonded ePTFE grafts compared with vein grafts in femoropopliteal and femorocrural bypasses: 1- and 2-year results. J. Vasc. Surg. 49, 1210–1216. doi: 10.1016/j.jvs.2008.12.009

PubMed Abstract | CrossRef Full Text | Google Scholar

Dahl, S. L., Kypson, A. P., Lawson, J. H., Blum, J. L., Strader, J. T., Li, Y., et al. (2011). Readily available tissue-engineered vascular grafts. Sci. Transl. Med. 3, 1–11. doi: 10.1126/scitranslmed.3001426

PubMed Abstract | CrossRef Full Text | Google Scholar

Damiano, M. G., Mutharasan, R. K., Tripathy, S., Mcmahon, K. M., and Thaxton, C. S. (2013). Templated high density lipoprotein nanoparticles as potential therapies and for molecular delivery. Adv. Drug Deliv. Rev. 65, 649–662. doi: 10.1016/j.addr.2012.07.013

PubMed Abstract | CrossRef Full Text | Google Scholar

Daminelli, E. N., Martinelli, A. E. M., Bulgarelli, A., Freitas, F. R., and Maranhão, R. C. (2016). Reduction of atherosclerotic lesions by the chemotherapeutic agent carmustine associated to lipid nanoparticles. Cardiovasc. Drugs Ther. 30, 433–443. doi: 10.1007/s10557-016-6675-0

PubMed Abstract | CrossRef Full Text | Google Scholar

De Visscher, G., Mesure, L., Meuris, B., Ivanova, A., and Flameng, W. (2012). Improved endothelialization and reduced thrombosis by coating a synthetic vascular graft with fibronectin and stem cell homing factor SDF-1alpha. Acta Biomater. 8, 1330–1338. doi: 10.1016/j.actbio.2011.09.016

PubMed Abstract | CrossRef Full Text | Google Scholar

Devine, C., Hons, B. A., and Mccollum, C. (2001). Heparin-bonded Dacron or polytetrafluoroethylene for femoropopliteal bypass grafting: a multicenter trial. J. Vasc. Surg. 33, 533–539. doi: 10.1067/mva.2001.113578

CrossRef Full Text | Google Scholar

Devine, C., Mccollum, C., and North West Femoro-Popliteal Trial Participants (2004). Heparin-bonded Dacron or polytetrafluorethylene for femoropopliteal bypass: five-year results of a prospective randomized multicenter clinical trial. J. Vasc. Surg. 40, 924–931. doi: 10.1016/j.jvs.2004.08.033

PubMed Abstract | CrossRef Full Text | Google Scholar

Dibra, A., Kastrati, A., Mehilli, J., Pache, J., Schühlen, H., Beckerath, N. V., et al. (2005). Paclitaxel-eluting or sirolimus-eluting stents to prevent restenosis in diabetic patients. N. Engl. J. Med. 353, 663–670. doi: 10.1056/NEJMoa044372

PubMed Abstract | CrossRef Full Text | Google Scholar

Dikina, A., Alt, D., Herberg, S., Mcmillan, A., Strobel, H., Zheng, Z., et al. (2018). A modular strategy to engineer complex tissues and organs. Adv. Sci. 5:1700402. doi: 10.1002/advs.201700402

PubMed Abstract | CrossRef Full Text | Google Scholar

Dikina, A. D., Strobel, H. A., Lai, B. P., Rolle, M. W., and Alsberg, E. (2015). Engineered cartilaginous tubes for tracheal tissue replacement via self-assembly and fusion of human mesenchymal stem cell constructs. Biomaterials 52, 452–462. doi: 10.1016/j.biomaterials.2015.01.073

PubMed Abstract | CrossRef Full Text | Google Scholar

Dimitrievska, S., Cai, C., Weyers, A., Balestrini, J. L., Lin, T., Sundaram, S., et al. (2015). Click-coated, heparinized, decellularized vascular grafts. Acta Biomater. 13, 177–187. doi: 10.1016/j.actbio.2014.11.015

PubMed Abstract | CrossRef Full Text | Google Scholar

Doi, K., and Matsuda, T. (1997). Enhanced vascularization in a microporous polyurethane graft impregnated with basic fibroblast growth factor and heparin. J. Biomed. Mater. Res. 34, 361–370. doi: 10.1002/(SICI)1097-4636(19970305)34:3<361::AID-JBM11>3.0.CO;2-J

PubMed Abstract | CrossRef Full Text | Google Scholar

Duivenvoorden, R., Tang, J., Cormode, D. P., Mieszawska, A. J., Izquierdo-Garcia, D., Ozcan, C., et al. (2014). A statin-loaded reconstituted high-density lipoprotein nanoparticle inhibits atherosclerotic plaque inflammation. Nat. Commun. 5:3065. doi: 10.1038/ncomms4065

PubMed Abstract | CrossRef Full Text | Google Scholar

Edlund, U., Sauter, T., and Albertsson, A. C. (2011). Covalent VEGF protein immobilization on resorbable polymeric surfaces. Polym. Adv. Technol. 22, 166–171. doi: 10.1002/pat.1811

CrossRef Full Text | Google Scholar

El-Hayek, G., Bangalore, S., Dominguez, A. C., Devireddy, C., Jaber, W., Kumar, G., et al. (2017). Meta-analysis of randomized clinical trials comparing biodegradable polymer drug-eluting stent to second-generation durable polymer drug-eluting stents. J. Am. Coll. Cardiol. Interv. 10, 462–473. doi: 10.1016/j.jcin.2016.12.002

PubMed Abstract | CrossRef Full Text | Google Scholar

Farb, A., Heller, P. F., Shroff, S., Cheng, L., Kolodgie, F. D., Carter, A. J., et al. (2001). Pathological analysis of local delivery of paclitaxel via a polymer-coated stent. Circulation 104, 473–479. doi: 10.1161/hc3001.092037

PubMed Abstract | CrossRef Full Text | Google Scholar

Farhan, S., Hemetsberger, R., Matiasek, J., Strehblow, C., Pavo, N., Khorsand, A., et al. (2009). Implantation of paclitaxel-eluting stent impairs the vascular compliance of arteries in porcine coronary stenting model. Atherosclerosis 202, 144–151. doi: 10.1016/j.atherosclerosis.2008.04.039

PubMed Abstract | CrossRef Full Text | Google Scholar

Ferrara, N., and Devis-Smyth, T. (1997). The biology of vascular endothelial growth factor. Endocr. Rev. 18, 4–25. doi: 10.1210/edrv.18.1.0287

PubMed Abstract | CrossRef Full Text | Google Scholar

Finkelstein, A., Mcclean, D., Kar, S., Takizawa, K., Varghese, K., Baek, N., et al. (2003). Local drug delivery via a coronary stent with programmable release pharmacokinetics. Circulation 107, 777–784. doi: 10.1161/01.CIR.0000050367.65079.71

PubMed Abstract | CrossRef Full Text | Google Scholar

Finn, A. V., Joner, M., Nakazawa, G., Kolodgie, F., Newell, J., John, M. C., et al. (2007a). Pathological correlates of late drug-eluting stent thrombosis: strut coverage as a marker of endothelialization. Circulation 115, 2435–2441. doi: 10.1161/CIRCULATIONAHA.107.693739

PubMed Abstract | CrossRef Full Text | Google Scholar

Finn, A. V., Nakazawa, G., Joner, M., Kolodgie, F. D., Mont, E. K., Gold, H. K., et al. (2007b). Vascular responses to drug eluting stents: importance of delayed healing. Arterioscler. Thromb. Vasc. Biol. 27, 1500–1510. doi: 10.1161/ATVBAHA.107.144220

PubMed Abstract | CrossRef Full Text | Google Scholar

Food and Drug Administration [FDA] (2008). Guidance for Industry: Coronary Drug-Eluting Stents— Nonclinical and Clinical Studies. Available at: http://www.gmp-compliance.org/guidemgr/files/UCM228705.PDF

Google Scholar

Food and Drug Administration [FDA] (2017). Drug Products, Including Biological Products, that Contain Nanomaterials: Guidance for Industry. Available at: http://scipol.duke.edu/content/fda-drug-products-including-biological-products-contain-nanomaterials-draft-guidance

Google Scholar

Fredman, G., Kamaly, N., Spolitu, S., Milton, J., Ghorpade, D., Chiasson, R., et al. (2015). Targeted nanoparticles containing the proresolving peptide Ac2-26 protect against advanced atherosclerosis in hypercholesterolemic mice. Sci. Transl. Med. 7, 1–9. doi: 10.1126/scitranslmed.aaa1065

PubMed Abstract | CrossRef Full Text | Google Scholar

Freeman, I., and Cohen, S. (2009). The influence of the sequential delivery of angiogenic factors from affinity-binding alginate scaffolds on vascularization. Biomaterials 30, 2122–2131. doi: 10.1016/j.biomaterials.2008.12.057

PubMed Abstract | CrossRef Full Text | Google Scholar

Gao, Y., Wang, Q., Cui, X., Liu, Y., Zheng, T., Chen, C., et al. (2014). Controlled release of stromal cell-derived factor-1α from silk fibroin-coated coils accelerates intra-aneurysmal organization and occlusion of neck remnant by recruiting endothelial progenitor cells. Int. J. Clin. Exp. Pathol. 7, 8366–8380.

Google Scholar

Garcia Cruz, D. M., Sardinha, V., Escobar Ivirico, J. L., Mano, J. F., and Gomez Ribelles, J. L. (2013). Gelatin microparticles aggregates as three-dimensional scaffolding system in cartilage engineering. J. Mater. Sci. Mater. Med. 24, 503–513. doi: 10.1007/s10856-012-4818-9

PubMed Abstract | CrossRef Full Text | Google Scholar

Go, A. S., Mozaffarian, D., Roger, V. L., Benjamin, E. J., Berry, J. D., Blaha, M. J., et al. (2014). Heart disease and stroke statistics–2014 update: a report from the American Heart Association. Circulation 129, e28–e292. doi: 10.1161/01.cir.0000441139.02102.80

PubMed Abstract | CrossRef Full Text | Google Scholar

Goldman, S., Sethi, G. K., Holman, W., Thai, H., McFalls, E., Ward, H. B., et al. (2011). Radial artery grafts vs saphenous vein grafts in coronary artery bypass surgery: a randomized trial. JAMA 305, 167–174. doi: 10.1001/jama.2010.1976

PubMed Abstract | CrossRef Full Text | Google Scholar

Gong, Z., and Niklason, L. E. (2008). Small-diameter human vessel wall engineered from bone marrow-derived mesenchymal stem cells (hMSCs). FASEB J. 22, 1635–1648. doi: 10.1096/fj.07-087924

PubMed Abstract | CrossRef Full Text | Google Scholar

Gosselin, C., Vorp, D., Warty, V., Severyn, D. A., Dick, E. K., Borovetz, H. S., et al. (1996). ePTFE coating with fibrin glue, FGF-1, and heparin: effect on retention of seeded endothelial cells. J. Surg. Res. 60, 327–332. doi: 10.1006/jsre.1996.0052

PubMed Abstract | CrossRef Full Text | Google Scholar

Grassl, E. D., Oegema, T. R., and Tranquillo, R. T. (2002). A fibrin-based arterial media equivalent. J. Biomed. Res. 66A, 550–561. doi: 10.1002/jbm.a.10589

PubMed Abstract | CrossRef Full Text | Google Scholar

Greisler, H. P., Cziperle, D. J., Kim, D. U., Garfield, J. D., Petsikas, D., Murchan, P. M., et al. (1992). Enhanced endothelialization of expanded polytetrafluoroethylene grafts by fibroblast growth factor type 1 pretreatment. Surgery 112, 244–255.

PubMed Abstract | Google Scholar

Grube, E., Silber, S., Hauptmann, K. E., Mueller, R., Buellesfeld, L., Gerckens, U., et al. (2002). TAXUS I: six- and twelve-month results from a randomized, double-blind trial on a slow-release paclitaxel-eluting stent for de novo coronary lesions. Circulation 107, 38–42. doi: 10.1161/01.CIR.0000047700.58683.A1

PubMed Abstract | CrossRef Full Text | Google Scholar

Gwyther, T. A., Hu, J. Z., Christakis, A. G., Skorinko, J. K., Shaw, S. M., Billiar, K. L., et al. (2011). Engineered vascular tissue fabricated from aggregated smooth muscle cells. Cells Tissues Organs 194, 13–24. doi: 10.1159/000322554

PubMed Abstract | CrossRef Full Text | Google Scholar

Hadinata, I. E., Hayward, P. A., Hare, D. L., Matalanis, G. S., Seevanayagam, S., Rosalion, A., et al. (2009). Choice of conduit for the right coronary system: 8-year analysis of Radial Artery Patency and Clinical Outcomes trial. Ann. Thorac. Surg. 88, 1404–1409. doi: 10.1016/j.athoracsur.2009.06.010

PubMed Abstract | CrossRef Full Text | Google Scholar

Hamada, K., Miura, Y., Toma, N., Miyamoto, K., Imanaka-Yoshida, K., Matsushima, S., et al. (2014). Gellan sulfate core platinum coil with tenascin-C promotes intra-aneurysmal organization in rats. Transl. Stroke Res. 5, 595–603. doi: 10.1007/s12975-014-0352-z

PubMed Abstract | CrossRef Full Text | Google Scholar

Harisa, G. I., and Alanazi, F. K. (2014). Low density lipoprotein bionanoparticles: from cholesterol transport to delivery of anti-cancer drugs. Saudi Pharm. J. 22, 504–515. doi: 10.1016/j.jsps.2013.12.015

PubMed Abstract | CrossRef Full Text | Google Scholar

Haude, M., Ince, H., Abizaid, A., Toelg, R., Lemos, P. A., Von Birgelen, C., et al. (2016). Safety and performance of the second-generation drug-eluting absorbable metal scaffold in patients with de-novo coronary artery lesions (BIOSOLVE-II): 6 month results of a prospective, multicentre, non-randomised, first-in-man trial. Lancet 387, 31–39. doi: 10.1016/S0140-6736(15)00447-X

PubMed Abstract | CrossRef Full Text | Google Scholar

Hayashi, K., and Tabata, Y. (2011). Preparation of stem cell aggregates with gelatin microspheres to enhance biological functions. Acta Biomater. 7, 2797–2803. doi: 10.1016/j.actbio.2011.04.013

PubMed Abstract | CrossRef Full Text | Google Scholar

Hibino, N., Mcgillicuddy, E., Matsumura, G., Ichihara, Y., Naito, Y., Breuer, C., et al. (2010). Late-term results of tissue-engineered vascular grafts in humans. J. Thorac. Cardiovasc. Surg. 139, 431–436. doi: 10.1016/j.jtcvs.2009.09.057

PubMed Abstract | CrossRef Full Text | Google Scholar

Higgins, S. P., Solan, A. K., and Niklason, L. E. (2003). Effects of polyglycolic acid on porcine smooth muscle cell growth and differentiation. J. Biomed. Mater. Res. 67A, 295–302. doi: 10.1002/jbm.a.10599

PubMed Abstract | CrossRef Full Text | Google Scholar

Ho, M.-Y., Chen, C.-C., Wang, C.-Y., Chang, S.-H., Hsieh, M.-J., Lee, C.-H., et al. (2016). The development of coronary artery stents: from bare-metal to bio-resorbable types. Metals 6:168. doi: 10.3390/met6070168

CrossRef Full Text | Google Scholar

Hodges, T. C., Fillinger, M. F., Zwolak, R. M., Walsh, D. B., Bech, F., and Cronenwett, J. L. (1997). Longitudinal comparison of dialysis access methods: risk factors for failure. J. Vasc. Surg. 26, 1009–1019. doi: 10.1016/S0741-5214(97)70014-4

CrossRef Full Text | Google Scholar

Hossfeld, S., Nolte, A., Hartmann, H., Recke, M., Schaller, M., Walker, T., et al. (2013). Bioactive coronary stent coating based on layer-by-layer technology for siRNA release. Acta Biomater. 9, 6741–6752. doi: 10.1016/j.actbio.2013.01.013

PubMed Abstract | CrossRef Full Text | Google Scholar

Huang, C., Wang, S., Qiu, L., Ke, Q., Zhai, W., and Mo, X. (2013). Heparin loading and pre-endothelialization in enhancing the patency rate of electrospun small-diameter vascular grafts in a canine model. ACS Appl. Mater. Interfaces 5, 2220–2226. doi: 10.1021/am400099p

PubMed Abstract | CrossRef Full Text | Google Scholar

Hwang, C. W., Levin, A. D., Jonas, M., Li, P. H., and Edelman, E. R. (2005). Thrombosis modulates arterial drug distribution for drug-eluting stents. Circulation 111, 1619–1626. doi: 10.1161/01.CIR.0000160363.30639.37

PubMed Abstract | CrossRef Full Text | Google Scholar

Innocente, F., Mandracchia, D., Pektok, E., Nottelet, B., Tille, J. C., De Valence, S., et al. (2009). Paclitaxel-eluting biodegradable synthetic vascular prostheses: a step towards reduction of neointima formation? Circulation 120, S37–S45. doi: 10.1161/CIRCULATIONAHA.109.848242

PubMed Abstract | CrossRef Full Text | Google Scholar

Ishii, Y., Sakamoto, S., Kronengold, R. T., Virmani, R., Rivera, E. A., Goldman, S. M., et al. (2008). A novel bioengineered small-caliber vascular graft incorporating heparin and sirolimus: excellent 6-month patency. J. Thorac. Cardiovasc. Surg. 135, 1237–1245; discussion 1245–1236. doi: 10.1016/j.jtcvs.2007.09.077

PubMed Abstract | CrossRef Full Text | Google Scholar

Jeon, O., Song, S. J., Kang, S. W., Putnam, A. J., and Kim, B. S. (2007). Enhancement of ectopic bone formation by bone morphogenetic protein-2 released from a heparin-conjugated poly(L-lactic-co-glycolic acid) scaffold. Biomaterials 28, 2763–2771. doi: 10.1016/j.biomaterials.2007.02.023

PubMed Abstract | CrossRef Full Text | Google Scholar

Johnson, J., Carson, K., Williams, H., Karanam, S., Newby, A., Angelini, G., et al. (2005). Plaque rupture after short periods of fat feeding in the apolipoprotein e-knockout mouse: model characterization and effects of pravastatin treatment. Circulation 111, 1422–1430. doi: 10.1161/01.CIR.0000158435.98035.8D

PubMed Abstract | CrossRef Full Text | Google Scholar

Joner, M., Finn, A. V., Farb, A., Mont, E. K., Kolodgie, F. D., Ladich, E., et al. (2006). Pathology of drug-eluting stents in humans: delayed healing and late thrombotic risk. J. Am. Coll. Cardiol. 48, 193–202. doi: 10.1016/j.jacc.2006.03.042

PubMed Abstract | CrossRef Full Text | Google Scholar

Kamaly, N., Fredman, G., Fojas, J. J. R., Subramanian, M., Choi, W. I., Zepeda, K., et al. (2016). Targeted interleukin-10 nanotherapeutics developed with a microfluidic chip enhance resolution of inflammation in advanced atherosclerosis. ACS Nano 10, 5280–5292. doi: 10.1021/acsnano.6b01114

PubMed Abstract | CrossRef Full Text | Google Scholar

Kastrati, A., Mehilli, J., Beckerath, N.V., Dibra, A., Hausleiter, J., Pache, J., et al. (2005). Sirolimus-eluting stent or paclitaxel-eluting stent vs balloon angioplasty for prevention of recurrences in patients with coronary in-stent restenosis. JAMA 293, 165–171. doi: 10.1001/jama.293.2.165

PubMed Abstract | CrossRef Full Text | Google Scholar

Katsuki, S., Matoba, T., Nakashiro, S., Sato, K., Koga, J. -I., Nakano, K., et al. (2014). Nanoparticle-mediated delivery of pitavastatin inhibits atherosclerotic plaque destabilization/rupture in mice by regulating the recruitment of inflammatory monocytes. Circ. J. 129, 896–906. doi: 10.1161/CIRCULATIONAHA.113.002870

PubMed Abstract | CrossRef Full Text | Google Scholar

Kennealey, P. T., Elias, N., Hertl, M., Ko, D. S., Saidi, R. F., Markmann, J. F., et al. (2011). A prospective, randomized comparison of bovine carotid artery and expanded polytetrafluoroethylene for permanent hemodialysis vascular access. J. Vasc. Surg. 53, 1640–1648. doi: 10.1016/j.jvs.2011.02.008

PubMed Abstract | CrossRef Full Text | Google Scholar

Kim, K., Luu, Y. K., Chang, C., Fang, D., Hsiao, B. S., Chu, B., et al. (2004). Incorporation and controlled release of a hydrophilic antibiotic using poly(lactide-co-glycolide)-based electrospun nanofibrous scaffolds. J. Control. Release 98, 47–56. doi: 10.1016/j.jconrel.2004.04.009

PubMed Abstract | CrossRef Full Text | Google Scholar

Klingberg, H., Loft, S., Oddershede, L. B., and Moller, P. (2015). The influence of flow, shear stress and adhesion molecule targeting on gold nanoparticle uptake in human endothelial cells. Nanoscale 7, 11409–11419. doi: 10.1039/C5NR01467K

PubMed Abstract | CrossRef Full Text | Google Scholar

Kobayashi, N., Ito, Y., Hirano, K., Yamawaki, M., Araki, M., Sakai, T., et al. (2016). Comparison of first- and second-generation drug-eluting stent efficacies for treating left main and/or three-vessel disease: a propensity matched study. Heart Vessels 31, 1930–1942. doi: 10.1007/s00380-016-0824-z

PubMed Abstract | CrossRef Full Text | Google Scholar

Korin, N., Kanapathipillai, M., Matthews, B. D., Crescente, M., Brill, A., Mammoto, T., et al. (2012). Shear-activated nanotherapeutics for drug targeting to obstructed blood vessels. Science 337, 738–742. doi: 10.1126/science.1217815

PubMed Abstract | CrossRef Full Text | Google Scholar

Kornowski, R., Hong, M. K., Tio, F. O., Bramwell, O., Wu, H., and Leon, M. B. (1998). In-stent restenosis: contributions of inflammatory responses and arterial injury to neointimal hyperplasia. JACC 31, 224–230. doi: 10.1016/S0735-1097(97)00450-6

PubMed Abstract | CrossRef Full Text | Google Scholar

Krucoff, M. W., Kereiakes, D. J., Petersen, J. L., Mehran, R., Hasselblad, V., Lansky, A. J., et al. (2008). A novel bioresorbable polymer paclitaxel-eluting stent for the treatment of single and multivessel coronary disease: primary results of the COSTAR (Cobalt Chromium Stent With Antiproliferative for Restenosis) II study. J. Am. Coll. Cardiol. 51, 1543–1552. doi: 10.1016/j.jacc.2008.01.020

PubMed Abstract | CrossRef Full Text | Google Scholar

Lammer, J., Zeller, T., Hausegger, K. A., Schaefer, P. J., Gschwendtner, M., Mueller-Huelsbeck, S., et al. (2013). Heparin-bonded covered stents versus bare-metal stents for complex femoropopliteal artery lesions: the randomized VIASTAR trial (Viabahn endoprosthesis with PROPATEN bioactive surface [VIA] versus bare nitinol stent in the treatment of long lesions in superficial femoral artery occlusive disease). J. Am. Coll. Cardiol. 62, 1320–1327. doi: 10.1016/j.jacc.2013.05.079

PubMed Abstract | CrossRef Full Text | Google Scholar

Larm, O., Larsson, R., and Olsson, P. (1983). A new non-thrombogenic surface prepared by selective covalent binding of heparin via a modified reducing terminal residue. Biomater. Med. Dev. Artif. Org. 11, 161–173. doi: 10.3109/10731198309118804

PubMed Abstract | CrossRef Full Text | Google Scholar

Lawson, J. H., Glickman, M. H., Ilzecki, M., Jakimowicz, T., Jaroszynski, A., Peden, E. K., et al. (2016). Bioengineered human acellular vessels for dialysis access in patients with end-stage renal disease: two phase 2 single-arm trials. Lancet 387, 2026–2034. doi: 10.1016/S0140-6736(16)00557-2

PubMed Abstract | CrossRef Full Text | Google Scholar

Lee, K., Silva, E. A., and Mooney, D. J. (2011). Growth factor delivery-based tissue engineering: general approaches and a review of recent developments. J. R. Soc. Interface 8, 153–170. doi: 10.1098/rsif.2010.0223

PubMed Abstract | CrossRef Full Text | Google Scholar

Lee, M., Chen, T. T., Iruela-Arispe, M. L., Wu, B. M., and Dunn, J. C. (2007). Modulation of protein delivery from modular polymer scaffolds. Biomaterials 28, 1862–1870. doi: 10.1016/j.biomaterials.2006.12.006

PubMed Abstract | CrossRef Full Text | Google Scholar

Lee, M. H., Arcidiacono, J. A., Bilek, A. M., Wille, J. J., Hamill, C. A., Wonnacott, K. M., et al. (2010). Considerations for tissue-engineered and regenerative medicine product development prior to clinical trials in the united states. Tissue Eng. Part B 16, 41–54. doi: 10.1089/ten.teb.2009.0449

PubMed Abstract | CrossRef Full Text | Google Scholar

Lemson, M. S., Tordoir, J. H., Daemen, M. J., and Kitslaar, P. J. (2000). Intimal hyperplasia in vascular grafts. Eur. J. Vasc. Endovasc. Surg. 19, 336–350. doi: 10.1053/ejvs.1999.1040

PubMed Abstract | CrossRef Full Text | Google Scholar

Leuschner, F., Dutta, P., Gorbatov, R., Novobrantseva, T. I., Donahoe, J. S., Courties, G., et al. (2011). Therapeutic siRNA silencing in inflammatory monocytes in mice. Nat. Biotechnol. 29, 1005–1010. doi: 10.1038/nbt.1989

PubMed Abstract | CrossRef Full Text | Google Scholar

Levin, A. D., Vukmirovic, N., Hwang, C. W., and Edelman, E. R. (2004). Specific binding to intracellular proteins determines arterial transport properties for rapamycin and paclitaxel. Proc. Natl. Acad. Sci. U.S.A. 101, 9463–9467. doi: 10.1073/pnas.0400918101

PubMed Abstract | CrossRef Full Text | Google Scholar

L’Heureux, N., Paquet, S., Labbe, R., Germain, L., and Auger, F. A. (1998). A completely biological tissue-engineered human blood vessel. FASEB J. 12, 47–56. doi: 10.1096/fasebj.12.1.47

CrossRef Full Text | Google Scholar

Li, J.-M., Newburger, P. E., Gounis, M., Dargon, P., Zhang, X., and Messina, L. M. (2010). Local arterial nanoparticle delivery of siRNA for NOX2 knockdown to prevent restenosis in an atherosclerotic rat model. Gene Ther. 17, 1279–1287. doi: 10.1038/gt.2010.69

PubMed Abstract | CrossRef Full Text | Google Scholar

Liao, J. K. (2005). Effects of statins on 3-hydroxy-3-methylglutaryl coenzyme a reductase inhibition beyond low-density lipoprotein cholesterol. Am. J. Cardiol. 96, 24F–33F. doi: 10.1016/j.amjcard.2005.06.009

PubMed Abstract | CrossRef Full Text | Google Scholar

Libby, P., and Theroux, P. (2005). Pathophysiology of coronary artery disease. Circulation 111, 3481–3488. doi: 10.1161/CIRCULATIONAHA.105.537878

PubMed Abstract | CrossRef Full Text | Google Scholar

Liebler, S., Grunert, F., Thompson, J., Wedel, M., and Schlosshauer, B. (2016). Towards a biofunctionalized vascular prosthesis: immune cell trapping via a growth factor receptor. J. Tissue Eng. Regen. Med. 11, 2699–2709. doi: 10.1002/term.2165

PubMed Abstract | CrossRef Full Text | Google Scholar

Lindeman, J. H., Abdul-Hussien, H., Van Bockel, J. H., Wolterbeek, R., and Kleemann, R. (2009). Clinical trial of doxycycline for matrix metalloproteinase-9 inhibition in patients with an abdominal aneurysm: doxycycline selectively depletes aortic wall neutrophils and cytotoxic T cells. Circulation 119, 2209–2216. doi: 10.1161/CIRCULATIONAHA.108.806505

PubMed Abstract | CrossRef Full Text | Google Scholar

Lindholt, J. S., Gottschalksen, B., Johannesen, N., Dueholm, D., Ravn, H., Christensen, E. D., et al. (2011). The Scandinavian Propaten((R)) trial - 1-year patency of PTFE vascular prostheses with heparin-bonded luminal surfaces compared to ordinary pure PTFE vascular prostheses - a randomised clinical controlled multi-centre trial. Eur. J. Vasc. Endovasc. Surg. 41, 668–673. doi: 10.1016/j.ejvs.2011.01.021

PubMed Abstract | CrossRef Full Text | Google Scholar

Liu, K. S., Lee, C. H., Wang, Y. C., and Liu, S. J. (2015). Sustained release of vancomycin from novel biodegradable nanofiber-loaded vascular prosthetic grafts: in vitro and in vivo study. Int. J. Nanomedicine 10, 885–891. doi: 10.2147/IJN.S78675

PubMed Abstract | CrossRef Full Text | Google Scholar

Liu, S., Liu, T., Chen, J., Maitz, M., Chen, C., and Huang, N. (2013). Influence of a layer-by-layer-assembled multilayer of anti-CD34 antibody, vascular endothelial growth factor, and heparin on the endothelialization and anticoagulation of titanium surface. J. Biomed. Mater. Res. A 101, 1144–1157. doi: 10.1002/jbm.a.34392

PubMed Abstract | CrossRef Full Text | Google Scholar

Lobatto, M. E., Calcagno, C., Otten, M. J., Millon, A., Ramachandran, S., Paridaans, M. P., et al. (2015). Pharmaceutical development and preclinical evaluation of a GMP-grade anti-inflammatory nanotherapy. Nanomedicine 11, 1133–1140. doi: 10.1016/j.nano.2015.02.020

PubMed Abstract | CrossRef Full Text | Google Scholar

Lu, S., Zhang, P., Sun, X., Gong, F., Yang, S., Shen, L., et al. (2013). Synthetic ePTFE grafts coated with an anti-CD133 antibody-functionalized heparin/collagen multilayer with rapid in vivo endothelialization properties. ACS Appl. Mater. Interfaces 5, 7360–7369. doi: 10.1021/am401706w

PubMed Abstract | CrossRef Full Text | Google Scholar

Ma, S., Tian, X. Y., Zhang, Y., Mu, C., Shen, H., Bismuth, J., et al. (2016). E-selectin-targeting delivery of microRNAs by microparticles ameliorates endothelial inflammation and atherosclerosis. Sci. Rep. 6:22910. doi: 10.1038/srep22910

PubMed Abstract | CrossRef Full Text | Google Scholar

Marmagkiolis, K., Hakeem, A., Choksi, N., Al-Hawwas, M., Edupuganti, M. M., Leesar, M. A., et al. (2014). 12-month primary patency rates of contemporary endovascular device therapy for femoro-popliteal occlusive disease in 6,024 patients: beyond balloon angioplasty. Catheter. Cardiovasc. Interv. 84, 555–564. doi: 10.1002/ccd.25510

PubMed Abstract | CrossRef Full Text | Google Scholar

Marupudi, N. I., Han, J. E., Li, K. W., Renard, V. M., Tyler, B. M., and Brem, H. (2007). Paclitaxel: a review of adverse toxicities and novel delivery strategies. Expert Opin. Drug Saf. 6, 609–621. doi: 10.1517/14740338.6.5.609

PubMed Abstract | CrossRef Full Text | Google Scholar

Marx, S. O., Jayaraman, T., Go, L. O., and Marks, A. R. (1995). Rapamycin-FKBP inhibits cell cycle regulators of proliferation in vascular smooth muscle cells. Circ. Res. 76, 412–417. doi: 10.1161/01.RES.76.3.412

PubMed Abstract | CrossRef Full Text | Google Scholar

Matsumoto, H., Terada, T., Tsuura, M., Itakura, T., and Ogawa, A. (2003). Basic fibroblast growth factor released from a platinum coil with a polyvinyl alcohol core enhances cellular proliferation and vascular wall thickness: an in vitro and in vivo study. Neurosurgery 53, 402–408. doi: 10.1227/01.NEU.0000073728.82721.8E

PubMed Abstract | CrossRef Full Text | Google Scholar

McGinty, S., Mccormick, C., Mckittrick, C., Kennedy, S., Oldroyd, K., Wheel, M., et al. (2017). “Combining mathematical modelling with in-vitro experiments to predict in-vivo drug eluting stent kinetics”, in Proceedings of the 5th International Conference on Computational and Mathematical Biomedical Engineering, eds P. Nithiarasu and A. M. Robertson (Pittsburgh, PA: CMBE).

Google Scholar

McGinty, S., Mckee, S., Wadsworth, R. M., and Mccormick, C. (2013). Modeling arterial wall drug concentrations following the insertion of a drug-eluting stent. SIAM J. Appl. Math. 73, 2004–2028. doi: 10.1137/12089065X

CrossRef Full Text | Google Scholar

Meinhart, J. G., Schense, J. C., Schima, H., Gorlitzer, M., Hubbell, J. A., Deutsch, M., et al. (2005). Enhanced endothelial cell retention on shear-stressed synthetic vascular grafts precoated with RGD-cross-linked fibrin. Tissue Eng. 11, 887–895. doi: 10.1089/ten.2005.11.887

PubMed Abstract | CrossRef Full Text | Google Scholar

Melchiorri, A. J., Hibino, N., and Fisher, J. P. (2013). Strategies and techniques to enhance the in situ endothelialization of small-diameter biodegradable polymeric vascular grafts. Tissue Eng. Part B Rev. 19, 292–307. doi: 10.1089/ten.teb.2012.0577

PubMed Abstract | CrossRef Full Text | Google Scholar

Melchiorri, A. J., Hibino, N., Yi, T., Lee, Y. U., Sugiura, T., Tara, S., et al. (2015). Contrasting biofunctionalization strategies for the enhanced endothelialization of biodegradable vascular grafts. Biomacromolecules 16, 437–446. doi: 10.1021/bm501853s

PubMed Abstract | CrossRef Full Text | Google Scholar

Meng, S., Liu, Z., Shen, L., Guo, Z., Chou, L. L., Zhong, W., et al. (2009). The effect of a layer-by-layer chitosan-heparin coating on the endothelialization and coagulation properties of a coronary stent system. Biomaterials 30, 2276–2283. doi: 10.1016/j.biomaterials.2008.12.075

PubMed Abstract | CrossRef Full Text | Google Scholar

Miura, K., Kadota, K., Habara, S., Shimada, T., Ohya, M., Amano, H., et al. (2017). Five-year outcomes after paclitaxel-coated balloon angioplasty for drug-eluting stent restenosis. Am. J. Cardiol. 119, 365–371. doi: 10.1016/j.amjcard.2016.10.030

PubMed Abstract | CrossRef Full Text | Google Scholar

Miura, Y., Tanemura, H., Fujimoto, M., Hamada, K., Miyamoto, K., Toma, N., et al. (2016). Aneurysm organization effects of gellan sulfate core platinum coil with tenascin-C in a simulated clinical setting and the possible mechanism. J. Stroke Cerebrovasc. Dis. 25, 771–780. doi: 10.1016/j.jstrokecerebrovasdis.2015.12.010

PubMed Abstract | CrossRef Full Text | Google Scholar

Moby, V., Boura, C., Kerdjoudj, H., Voegel, J. -C., Marchal, L., Dumas, D., et al. (2007). Poly(styrenesulfonate)/Poly(allylamine) multilayers: a route to favor endothelial cell growth on expanded poly(tetrafluoroethylene) vascular grafts. Biomacromolecules 8, 2156–2160. doi: 10.1021/bm070348n

PubMed Abstract | CrossRef Full Text | Google Scholar

Morice, M. -C., Serruys, P. W., Sousa, J. E., Fajadet, J., Hayashi, E. B., Perin, M., et al. (2002). A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization. N. Engl. J. Med. 346, 1773–1780. doi: 10.1056/NEJMoa012843

PubMed Abstract | CrossRef Full Text | Google Scholar

Moses, J. W., Leon, M. B., Popma, J. J., Fitzgerald, P. J., Holmes, D. R., O’shaughnessy, C., et al. (2003). Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery. N. Engl. J. Med. 349, 1315–1323. doi: 10.1056/NEJMoa035071

PubMed Abstract | CrossRef Full Text | Google Scholar

Nahrendorf, M., Jaffer, F. A., Kelly, K. A., Sosnovik, D. E., Aikawa, E., Libby, P., et al. (2006). Noninvasive vascular cell adhesion molecule-1 imaging identifies inflammatory activation of cells in atherosclerosis. Circulation 114, 1504–1511. doi: 10.1161/CIRCULATIONAHA.106.646380

PubMed Abstract | CrossRef Full Text | Google Scholar

Nakazawa, G., Finn, A. V., Joner, M., Ladich, E., Kutys, R., Mont, E. K., et al. (2008). Delayed arterial healing and increased late stent thrombosis at culprit sites after drug-eluting stent placement for acute myocardial infarction patients: an autopsy study. Circulation 118, 1138–1145. doi: 10.1161/CIRCULATIONAHA.107.762047

PubMed Abstract | CrossRef Full Text | Google Scholar

Narang, A. S., Chang, R. K., and Hussain, M. A. (2013). Pharmaceutical development and regulatory considerations for nanoparticles and nanoparticulate drug delivery systems. J. Pharm. Sci. 102, 3867–3882. doi: 10.1002/jps.23691

PubMed Abstract | CrossRef Full Text | Google Scholar

Navarese, E. P., Tandjung, K., Claessen, B., Andreotti, F., Kowalewski, M., Kandzari, D. E., et al. (2013). Safety and efficacy outcomes of first and second generation durable polymer drug eluting stents and biodegradable polymer biolimus eluting stents in clinical practice: comprehensive network meta-analysis. BMJ 347:f6530. doi: 10.1136/bmj.f6530

PubMed Abstract | CrossRef Full Text | Google Scholar

Nie, S., Zhang, J., Martinez-Zaguilan, R., Sennoune, S., Hossen, M. N., Lichtenstein, A. H., et al. (2015). Detection of atherosclerotic lesions and intimal macrophages using CD36-targeted nanovesicles. J. Control. Release 220, 61–70. doi: 10.1016/j.jconrel.2015.10.004

PubMed Abstract | CrossRef Full Text | Google Scholar

Niklason, L. E., Gao, J., Abbott, W. M., Hirschi, K. K., Houser, S., Marini, R., et al. (1999). Functional arteries grown in vitro. Science 284, 489–493. doi: 10.1126/science.284.5413.489

CrossRef Full Text | Google Scholar

Noishiki, Y., Miyata, T., and Kodaira, K. (1986). Development of a small caliber vascular graft by a new crosslinking method incorporating slow heparin release collagen and natural tissue compliance. ASAIO Trans. 32, 114–119.

PubMed Abstract | Google Scholar

Nojiri, C., Noishiki, Y., and Koyanagi, H. (1987). Aorta-coronary bypass grafting with heparinized vascular grafts in dogs. A preliminary study. J. Thorac. Cardiovasc. Surg. 93, 867–877.

PubMed Abstract | Google Scholar

Nosoudi, N., Nahar-Gohad, P., Sinha, A., Chowdhury, A., Gerard, P., Carsten, C. G., et al. (2015). Prevention of abdominal aortic aneurysm progression by targeted inhibition of matrix metalloproteinase activity with batimastat-loaded nanoparticles. Circ. Res. 117, e80–e89. doi: 10.1161/CIRCRESAHA.115.307207

PubMed Abstract | CrossRef Full Text | Google Scholar

O’Banion, L. A., Wu, B., Eichler, C. M., Reilly, L. M., Conte, M. S., and Hiramoto, J. S. (2016). Cryopreserved saphenous vein as a last-ditch conduit for limb salvage. J. Vasc. Surg. 66, 844–849. doi: 10.1016/j.jvs.2017.03.415

PubMed Abstract | CrossRef Full Text | Google Scholar

O’Donnell, J. (2012). Anticoagulants: therapeutics, risks, and toxicity–special emphasis on heparin-induced thrombocytopenia (HIT). J. Pharm. Pract. 25, 22–29. doi: 10.1177/0897190011431146

PubMed Abstract | CrossRef Full Text | Google Scholar

Ohyama, T., Nishide, T., Iwata, H., Sato, H., Toda, M., and Taki, W. (2004). Vascular endothelial growth factor immobilized on platinum microcoils for the treatment of intracranial aneurysms: experimental rat model study. Neurol. Med. Chir. 44, 279–287. doi: 10.2176/nmc.44.279

PubMed Abstract | CrossRef Full Text | Google Scholar

Palekar, R. U., Jallouk, A. P., Lanza, G. M., Pan, H., and Wickline, S. A. (2015). Molecular imaging of atherosclerosis with nanoparticle-based fluorinated MRI contrast agents. Nanomedicine 10, 1817–1832. doi: 10.2217/nnm.15.26

PubMed Abstract | CrossRef Full Text | Google Scholar

Pandya, B., Gaddam, S., Raza, M., Asti, D., Nalluri, N., Vazzana, T., et al. (2016). Biodegradable polymer stents vs second generation drug eluting stents: a meta-analysis and systematic review of randomized controlled trials. World J. Cardiol. 8, 240–246. doi: 10.4330/wjc.v8.i2.240

PubMed Abstract | CrossRef Full Text | Google Scholar

Panyam, J., and Labhasetwar, V. (2004). Sustained cytoplasmic delivery of drugs with intracellular receptors using biodegradable nanoparticles. Mol. Pharm. 1, 77–84. doi: 10.1021/mp034002c

PubMed Abstract | CrossRef Full Text | Google Scholar

Pashneh-Tala, S., Macneil, S., and Claeyssens, F. (2015). The tissue-engineered vascular graft-past, present, and future. Tissue Eng. Part B Rev.Z doi: 10.1089/ten.teb.2015.0100 [Epub ahead of print].

PubMed Abstract | CrossRef Full Text | Google Scholar

Pfisterer, M., Brunner-La Rocca, H. P., Buser, P. T., Rickenbacher, P., Hunziker, P., Mueller, C., et al. (2006). Late clinical events after clopidogrel discontinuation may limit the benefit of drug-eluting stents: an observational study of drug-eluting versus bare-metal stents. J. Am. Coll. Cardiol. 48, 2584–2591. doi: 10.1016/j.jacc.2006.10.026

PubMed Abstract | CrossRef Full Text | Google Scholar

Pierot, L., and Wakhloo, A. K. (2013). Endovascular treatment of intracranial aneurysms: current status. Stroke 44, 2046–2054. doi: 10.1161/STROKEAHA.113.000733

PubMed Abstract | CrossRef Full Text | Google Scholar

Punnakitikashem, P., Truong, D., Menon, J. U., Nguyen, K. T., and Hong, Y. (2014). Electrospun biodegradable elastic polyurethane scaffolds with dipyridamole release for small diameter vascular grafts. Acta Biomater. 10, 4618–4628. doi: 10.1016/j.actbio.2014.07.031

PubMed Abstract | CrossRef Full Text | Google Scholar

Radeleff, B., Lopez-Benitez, R., Stampfl, U., Stampfl, S., Sommer, C., Thierjung, H., et al. (2010). Paclitaxel-induced arterial wall toxicity and inflammation: tissue uptake in various dose densities in a minipig model. J. Vasc. Interv. Radiol. 21, 1262–1270. doi: 10.1016/j.jvir.2010.02.020

PubMed Abstract | CrossRef Full Text | Google Scholar

Randon, C., Jacobs, B., De Ryck, F., Beele, H., and Vermassen, F. (2010). Fifteen years of infrapopliteal arterial reconstructions with cryopreserved venous allografts for limb salvage. J. Vasc. Surg. 51, 869–877. doi: 10.1016/j.jvs.2009.11.062

PubMed Abstract | CrossRef Full Text | Google Scholar

Randone, B., Cavallaro, G., Polistena, A., Cucina, A., Coluccia, P., Graziano, P., et al. (2005). Dual role of VEGF in pretreated experimental ePTFE arterial grafts. J. Surg. Res. 127, 70–79. doi: 10.1016/j.jss.2004.09.005

PubMed Abstract | CrossRef Full Text | Google Scholar

Ren, X., Feng, Y., Guo, J., Wang, H., Li, Q., Yang, J., et al. (2015). Surface modification and endothelialization of biomaterials as potential scaffolds for vascular tissue engineering applications. Chem. Soc. Rev. 44:5745. doi: 10.1039/C5CS90066B

PubMed Abstract | CrossRef Full Text | Google Scholar

Rittger, H., Brachmann, J., Sinha, A. M., Waliszewski, M., Ohlow, M., Brugger, A., et al. (2012). A randomized, multicenter, single-blinded trial comparing paclitaxel-coated balloon angioplasty with plain balloon angioplasty in drug-eluting stent restenosis: the PEPCAD-DES study. J. Am. Coll. Cardiol. 59, 1377–1382. doi: 10.1016/j.jacc.2012.01.015

PubMed Abstract | CrossRef Full Text | Google Scholar

Rychter, M., Baranowska-Korczyc, A., and Lulek, J. (2017). Progress and perspectives in bioactive agent delivery via electrospun vascular grafts. RSC Adv. 7, 32164–32184. doi: 10.1039/C7RA04735E

CrossRef Full Text | Google Scholar

Samson, R. H., Morales, R., Showalter, D. P., Lepore, M. R. Jr., and Nair, D. G. (2016). Heparin-bonded expanded polytetrafluoroethylene femoropopliteal bypass grafts outperform expanded polytetrafluoroethylene grafts without heparin in a long-term comparison. J. Vasc. Surg. 64, 638–647. doi: 10.1016/j.jvs.2016.03.414

PubMed Abstract | CrossRef Full Text | Google Scholar

Sano, H., Toda, M., Sugihara, T., Uchiyama, N., Hamada, J., and Iwata, H. (2010). Coils coated with the cyclic peptide SEK-1005 accelerate intra-aneurysmal organization. Neurosurgery 67, 984–991; discussion 992. doi: 10.1227/NEU.0b013e3181eb95da

PubMed Abstract | CrossRef Full Text | Google Scholar

Sapienza, P., Di Marzo, L., Cucina, A., Borrelli, V., Mosiello, G., Basile, U., et al. (2009). The effect of locally administered anti-growth factor antibodies on neointimal hyperplasia formation in expanded polytetrafluoroethylene grafts. Ann. Vasc. Surg. 23, 398–409. doi: 10.1016/j.avsg.2008.11.012

PubMed Abstract | CrossRef Full Text | Google Scholar

Saxon, R. R., Chervu, A., Jones, P. A., Bajwa, T. K., Gable, D. R., Soukas, P. A., et al. (2013). Heparin-bonded, expanded polytetrafluoroethylene-lined stent graft in the treatment of femoropopliteal artery disease: 1-year results of the VIPER (Viabahn Endoprosthesis with Heparin Bioactive Surface in the Treatment of Superficial Femoral Artery Obstructive Disease) trial. J. Vasc. Interv. Radiol. 24, 165–173; quiz 174. doi: 10.1016/j.jvir.2012.10.004

PubMed Abstract | CrossRef Full Text | Google Scholar

Selvarasu, N. K., Tafti, D. K., and Vlachos, P. P. (2011). Hydrodynamic effects of compliance mismatch in stented arteries. J. Biomech. Eng. 133:021008. doi: 10.1115/1.4003319

PubMed Abstract | CrossRef Full Text | Google Scholar

Seo, T., Lafont, A., Choi, S. Y., and Barakat, A. I. (2016). Drug-eluting stent design is a determinant of drug concentration at the endothelial cell surface. Ann. Biomed. Eng. 44, 302–314. doi: 10.1007/s10439-015-1531-0

PubMed Abstract | CrossRef Full Text | Google Scholar

Serruys, P. W., Ormiston, J., Van Geuns, R. J., De Bruyne, B., Dudek, D., Christiansen, E., et al. (2016). A polylactide bioresorbable scaffold eluting everolimus for treatment of coronary stenosis: 5-year follow-up. J. Am. Coll. Cardiol. 67, 766–776. doi: 10.1016/j.jacc.2015.11.060

PubMed Abstract | CrossRef Full Text | Google Scholar

Shah, P. J., Bui, K., Blackmore, S., Gordon, I., Hare, D. L., Fuller, J., et al. (2005). Has the in situ right internal thoracic artery been overlooked? An angiographic study of the radial artery, internal thoracic arteries and saphenous vein graft patencies in symptomatic patients. Eur. J. Cardiothorac. Surg. 27, 870–875. doi: 10.1016/j.ejcts.2005.01.027

PubMed Abstract | CrossRef Full Text | Google Scholar

Shemesh, D., Goldin, I., Hijazi, J., Zaghal, I., Berelowitz, D., Verstandig, A., et al. (2015). A prospective randomized study of heparin-bonded graft (Propaten) versus standard graft in prosthetic arteriovenous access. J. Vasc. Surg. 62, 115–122. doi: 10.1016/j.jvs.2015.01.056

PubMed Abstract | CrossRef Full Text | Google Scholar

Shiozaki, A. A., Senra, T., Morikawa, A. T., Deus, D. B. F., Paladino-Filho, A. T., Pinto, I. M. F., et al. (2016). Treatment of patients with aortic atherosclerotic disease with paclitaxel-associated lipid nanoparticles. Clinics 71, 435–439. doi: 10.6061/clinics/2016(08)05

PubMed Abstract | CrossRef Full Text | Google Scholar

Siracuse, J. J., Giles, K. A., Pomposelli, F. B., Hamdan, A. D., Wyers, M. C., Chaikof, E. L., et al. (2012). Results for primary bypass versus primary angioplasty/stent for intermittent claudication due to superficial femoral artery occlusive disease. J. Vasc. Surg. 55, 1001–1007. doi: 10.1016/j.jvs.2011.10.128

PubMed Abstract | CrossRef Full Text | Google Scholar

Sivaraman, B., and Ramamurthi, A. (2013). Multifunctional nanoparticles for doxycycline delivery towards localized elastic matrix stabilization and regenerative repair. Acta Biomater. 9, 6511–6525. doi: 10.1016/j.actbio.2013.01.023

PubMed Abstract | CrossRef Full Text | Google Scholar

Sivaraman, B., Swaminathan, G., Moore, L., Fox, J., Seshadri, D., Dahal, S., et al. (2017). Magnetically-responsive, multifunctional drug delivery nanoparticles for elastic matrix regenerative repair. Acta Biomater. 52, 171–186. doi: 10.1016/j.actbio.2016.11.048

PubMed Abstract | CrossRef Full Text | Google Scholar

Sivaraman, B., Sylvester, A., and Ramamurthi, A. (2016). Fibrinolytic PLGA nanoparticles for slow clot lysis within abdominal aortic aneurysms attenuate proteolytic loss of vascular elastic matrix. Mater. Sci. Eng. C Mater. Biol. Appl. 59, 145–156. doi: 10.1016/j.msec.2015.09.056

PubMed Abstract | CrossRef Full Text | Google Scholar

Solorio, L. D., Dhami, C. D., Dang, P. N., Vieregge, E. L., and Alsberg, E. (2012a). Spatiotemporal regulation of chondrogenic differentiation with controlled delivery of transforming growth factor-beta1 from gelatin microspheres in mesenchymal stem cell aggregates. Stem Cells Transl. Med. 1, 632–639. doi: 10.5966/sctm.2012-0039

PubMed Abstract | CrossRef Full Text | Google Scholar

Solorio, L. D., Vieregge, E. L., Dhami, C. D., Dang, P. N., and Alsberg, E. (2012b). Engineered cartilage via self-assembled hMSC sheets with incorporated biodegradable gelatin microspheres releasing transforming growth factor-beta1. J. Control. Release 158, 224–232. doi: 10.1016/j.jconrel.2011.11.003

PubMed Abstract | CrossRef Full Text | Google Scholar

Solorio, L. D., Fu, A. S., Hernandez-Irizarry, R., and Alsberg, E. (2010). Chondrogenic differentiation of human mesenchymal stem cell aggregates via controlled release of TGF-beta1 from incorporated polymer microspheres. J. Biomed. Mater. Res. A 92, 1139–1144.

PubMed Abstract | Google Scholar

Sousa, J. E., Costa, M. A., Abizaid, A. C., Rensing, B. J., Abizaid, A. S., Tanajura, L. F., et al. (2001). Sustained suppression of neointimal proliferation by sirolimus-eluting stents. Circulation 104, 2007–2011. doi: 10.1161/hc4201.098056

CrossRef Full Text | Google Scholar

Spadaccio, C., Nappi, F., De Marco, F., Sedati, P., Sutherland, F.W., Chello, M., et al. (2016). Preliminary in vivo evaluation of a hybrid armored vascular graft combining electrospinning and additive manufacturing techniques. Drug Target Insights 10, 1–7. doi: 10.4137/DTI.S35202

PubMed Abstract | CrossRef Full Text | Google Scholar

Stone, G. W., Ellis, S. G., Cox, D. A., Hermiller, J., O’shaughnessy, C., Mann, J. T., et al. (2004). A polymer-based, paclitaxel-eluting stent in patients with coronary artery disease. N. Engl. J. Med. 350, 221–231. doi: 10.1056/NEJMoa032441

PubMed Abstract | CrossRef Full Text | Google Scholar

Stone, G. W., Gao, R., Kimura, T., Kereiakes, D. J., Ellis, S. G., Onuma, Y., et al. (2016). 1-year outcomes with the Absorb bioresorbable scaffold in patients with coronary artery disease: a patient-level, pooled meta-analysis. Lancet 387, 1277–1289. doi: 10.1016/S0140-6736(15)01039-9

PubMed Abstract | CrossRef Full Text | Google Scholar

Strobel, H. A., Dikina, A. D., Levi, K., Solorio, L. D., Alsberg, E., and Rolle, M. W. (2017). Cellular self-assembly with microsphere incorporation for growth factor delivery within engineered vascular tissue rings. Tissue Eng. Part A 23, 143–155. doi: 10.1089/ten.tea.2016.0260

PubMed Abstract | CrossRef Full Text | Google Scholar

Strobel, H. A., Hookway, T. A., Piola, M., Fiore, G. B., Soncini, M., Alsberg, E., et al. (2018). Assembly of tissue engineered blood vessels with spatially-controlled heterogeneities. Tissue Eng. Part A 24, 1492–1503. doi: 10.1089/ten.tea.2017.0492

PubMed Abstract | CrossRef Full Text | Google Scholar

Su, L. C., Chen, Y. H., and Chen, M. C. (2013). Dual drug-eluting stents coated with multilayers of hydrophobic heparin and sirolimus. ACS Appl. Mater. Interfaces 5, 12944–12953. doi: 10.1021/am403615q

PubMed Abstract | CrossRef Full Text | Google Scholar

Suzuki, T., Kopia, G., Hayashi, S.-I., Bailey, L. R., Llanos, G., Wilensky, R., et al. (2001). Stent-based delivery of sirolimus reduces neointimal formation in a porcine coronary model. Circulation 104, 1188–1193. doi: 10.1161/hc3601.093987

PubMed Abstract | CrossRef Full Text | Google Scholar

Sylvester, A., Sivaraman, B., Deb, P., and Ramamurthi, A. (2013). Nanoparticles for localized delivery of hyaluronan oligomers towards regenerative repair of elastic matrix. Acta Biomater. 9, 9292–9302. doi: 10.1016/j.actbio.2013.07.032

PubMed Abstract | CrossRef Full Text | Google Scholar

Tabata, Y., and Ikada, Y. (1998). Protein release from gelatin matrices. Adv. Drug Deliv. Rev. 31, 287–301. doi: 10.1016/S0169-409X(97)00125-7

CrossRef Full Text | Google Scholar

Tada, T., Byrne, R. A., Simunovic, I., King, L. A., Cassese, S., Joner, M., et al. (2013). Risk of stent thrombosis among bare-metal stents, first-generation drug-eluting stents, and second-generation drug-eluting stents: results from a registry of 18,334 patients. JACC Cardiovasc. Interv. 6, 1267–1274. doi: 10.1016/j.jcin.2013.06.015

PubMed Abstract | CrossRef Full Text | Google Scholar

Tajima, S., and Tabata, Y. (2013). Preparation and functional evaluation of cell aggregates incorporating gelatin microspheres with different degradabilities. J. Tissue Eng. Regen. Med. 7, 801–811.

PubMed Abstract | Google Scholar

Tan, J., Shah, S., Thomas, A., Ou-Yang, H. D., and Liu, Y. (2013). The influence of size, shape and vessel geometry on nanoparticle distribution. Microfluid. Nanofluidics 14, 77–87. doi: 10.1007/s10404-012-1024-5

PubMed Abstract | CrossRef Full Text | Google Scholar

Tarafdar, S. A., and Gannon, M. X. (2017). Abdominal aortic aneurysm. Innovait 10, 290–296. doi: 10.1177/1755738017693654

CrossRef Full Text | Google Scholar

Thompson, R. W., and Parks, W. C. (1996). Role of matrix metalloproteinases in abdominal aortic aneurysms. Ann. N. Y. Acad. Sci. 800, 157–174. doi: 10.1111/j.1749-6632.1996.tb33307.x

CrossRef Full Text | Google Scholar

Toma, N., Imanaka-Yoshida, K., Takeuchi, T., Matsishima, S., Iwata, H., Yoshida, T., et al. (2005). Tenascin-C–coated platinum coils for acceleration of organization of cavities and reduction of lumen size in a rat aneurysm model. J. Neurosurg. 103, 681–686. doi: 10.3171/jns.2005.103.4.0681

PubMed Abstract | CrossRef Full Text | Google Scholar

Toyota, T., Morimoto, T., Shiomi, H., Yoshikawa, Y., Yaku, H., Yamashita, Y., et al. (2017). Very late scaffold thrombosis of bioresorbable vascular scaffold: systematic review and a meta-analysis. JACC Cardiovasc. Interv. 10, 27–37. doi: 10.1016/j.jcin.2016.10.027

PubMed Abstract | CrossRef Full Text | Google Scholar

Tsilimparis, N., Larena-Avellaneda, A., Krause, B., Wipper, S., Diener, H., Kolbel, T., et al. (2015). Results of the gore hybrid vascular graft in challenging aortic branch revascularization during complex aneurysm repair. Ann. Vasc. Surg. 29, 1426–1433. doi: 10.1016/j.avsg.2015.04.079

PubMed Abstract | CrossRef Full Text | Google Scholar

Tsumoto, T., Matsumoto, H., Terada, T., Tsuura, M., Itakura, T., and Hamamoto, T. (2007). A polyvinyl alcohol core coil containing basic fibroblast growth factor evaluated in rabbits with aneurysms induced by elastase. Neurosurgery 61. 160–166; discussion 166. doi: 10.1227/01.neu.0000279737.07683.57

PubMed Abstract | CrossRef Full Text | Google Scholar

Twal, W. O., Klatt, S. C., Harikrishnan, K., Gerges, E., Cooley, M. A., Trusk, T. C., et al. (2014). Cellularized microcarriers as adhesive building blocks for fabrication of tubular tissue constructs. Ann. Biomed. Eng. 42, 1470–1481. doi: 10.1007/s10439-013-0883-6

PubMed Abstract | CrossRef Full Text | Google Scholar

Urban, P., Meredith, I. T., Abizaid, A., Pocock, S. J., Carrie, D., Naber, C., et al. (2015). Polymer-free drug-coated coronary stents in patients at high bleeding risk. N. Engl. J. Med. 373, 2038–2047. doi: 10.1056/NEJMoa1503943

PubMed Abstract | CrossRef Full Text | Google Scholar

Valgimigli, M., Tebaldi, M., Borghesi, M., Vranckx, P., Campo, G., Tumscitz, C., et al. (2014). Two-year outcomes after first- or second-generation drug-eluting or bare-metal stent implantation in all-comer patients undergoing percutaneous coronary intervention: a pre-specified analysis from the PRODIGY study (PROlonging Dual Antiplatelet Treatment After Grading stent-induced Intimal hyperplasia studY). JACC Cardiovasc. Interv. 7, 20–28. doi: 10.1016/j.jcin.2013.09.008

PubMed Abstract | CrossRef Full Text | Google Scholar

van der Giessen, W. J., Sorop, O., Serruys, P. W., Peters-Krabbendam, I., and Van Beusekom, H. M. (2009). Lowering the dose of sirolimus, released from a nonpolymeric hydroxyapatite coated coronary stent, reduces signs of delayed healing. JACC Cardiovasc. Interv. 2, 284–290. doi: 10.1016/j.jcin.2008.12.012

PubMed Abstract | CrossRef Full Text | Google Scholar

van der Valk, F. M., Van Wijk, D. F., Lobatto, M. E., Verberne, H. J., Storm, G., Willems, M. C., et al. (2015). Prednisolone-containing liposomes accumulate in human atherosclerotic macrophages upon intravenous administration. Nanomedicine 11, 1039–1046. doi: 10.1016/j.nano.2015.02.021

PubMed Abstract | CrossRef Full Text | Google Scholar

Veith, F., Moss, C., Sprayregen, S., and Montefusco, C. (1979). Preoperative saphenous venography in arterial reconstructive surgery of the lower extremity. Surgery 85, 253–256.

PubMed Abstract | Google Scholar

Venkataraman, L., Sivaraman, B., Vaidya, P., and Ramamurthi, A. (2016). Nanoparticulate delivery of agents for induced elastogenesis in three-dimensional collagenous matrices. J. Tissue Eng. Regen. Med. 10, 1041–1056. doi: 10.1002/term.1889

PubMed Abstract | CrossRef Full Text | Google Scholar

Walkey, C. D., Olsen, J. B., Guo, H., Emili, A., and Chan, W. C. (2012). Nanoparticle size and surface chemistry determine serum protein adsorption and macrophage uptake. J. Am. Chem. Soc. 134, 2139–2147. doi: 10.1021/ja2084338

PubMed Abstract | CrossRef Full Text | Google Scholar

Walluscheck, K. P., Bierkandt, S., Brandt, M., and Cremer, J. (2005). Infrainguinal ePTFE vascular graft with bioactive surface heparin bonding: first clinical results. J. Cardiovasc. Surg. 46, 425–430.

PubMed Abstract | Google Scholar

Walpoth, B. H., Zammaretti, P., Cikirikcioglu, M., Khabiri, E., Djebaili, M. K., Pache, J. C., et al. (2007). Enhanced intimal thickening of expanded polytetrafluoroethylene grafts coated with fibrin or fibrin-releasing vascular endothelial growth factor in the pig carotid artery interposition model. J. Thorac. Cardiovasc. Surg. 133, 1163–1170. doi: 10.1016/j.jtcvs.2007.01.029

PubMed Abstract | CrossRef Full Text | Google Scholar

Wang, Q., Gao, Y., Sun, X., Ji, B., Cui, X., Liu, Y., et al. (2014). Acceleration of aneurysm healing by P(DLLA-co-TMC)-coated coils enabling the controlled release of vascular endothelial growth factor. Biomed. Mater. 9:045004. doi: 10.1088/1748-6041/9/4/045004

PubMed Abstract | CrossRef Full Text | Google Scholar

Wang, S., Mo, X. M., Jiang, B. J., Gao, C. J., Wang, H. S., Zhuang, Y. G., et al. (2013). Fabrication of small-diameter vascular scaffolds by heparin-bonded P(LLA-CL) composite nanofibers to improve graft patency. Int. J. Nanomedicine 8, 2131–2139. doi: 10.2147/IJN.S44956

PubMed Abstract | CrossRef Full Text | Google Scholar

Wang, X., Wenk, E., Zhang, X., Meinel, L., Vunjak-Novakovic, G., and Kaplan, D. L. (2009). Growth factor gradients via microsphere delivery in biopolymer scaffolds for osteochondral tissue engineering. J. Control. Release 134, 81–90. doi: 10.1016/j.jconrel.2008.10.021

PubMed Abstract | CrossRef Full Text | Google Scholar

Wang, X. N., Chen, C. Z., Yang, M., and Gu, Y. J. (2007). Implantation of decellularized small-caliber vascular xenografts with and without surface heparin treatment. Artif. Organs 31, 99–104. doi: 10.1111/j.1525-1594.2007.00348.x

PubMed Abstract | CrossRef Full Text | Google Scholar

Wang, Y.-J., Larsson, M., Huang, W.-T., Chiou, S.-H., Nicholls, S. J., Chao, J.-I., et al. (2016). The use of polymer-based nanoparticles and nanostructured materials in treatment and diagnosis of cardiovascular diseases: recent advances and emerging designs. Prog. Polym. Sci. 57, 153–178. doi: 10.1016/j.progpolymsci.2016.01.002

CrossRef Full Text | Google Scholar

Wang, Z., Lu, Y., Qin, K., Wu, Y., Tian, Y., Wang, J., et al. (2015). Enzyme-functionalized vascular grafts catalyze in-situ release of nitric oxide from exogenous NO prodrug. J. Control. Release 210, 179–188. doi: 10.1016/j.jconrel.2015.05.283

PubMed Abstract | CrossRef Full Text | Google Scholar

Washington, K. S., and Bashur, C. A. (2017). Delivery of antioxidant and anti-inflammatory agents for tissue engineered vascular grafts. Front. Pharmacol. 8:659. doi: 10.3389/fphar.2017.00659

PubMed Abstract | CrossRef Full Text | Google Scholar

Weakley, S. M., Wang, X., Mu, H., Lu, J., Lin, P. H., Yao, Q., et al. (2011). Ginkgolide A-gold nanoparticles inhibit vascular smooth muscle proliferation and migration in vitro and reduce neointimal hyperplasia in a mouse model. J. Surg. Res. 171, 31–39. doi: 10.1016/j.jss.2011.03.018

PubMed Abstract | CrossRef Full Text | Google Scholar

Winter, P. M., Caruthers, S. D., Zhang, H., Williams, T. A., Wickline, S. A., and Lanza, G. M. (2008). Antiangiogenic synergism of integrin-targeted fumagillin nanoparticles and atorvastatin in atherosclerosis. JACC Cardiovasc. Imaging 1, 224–234. doi: 10.1016/j.jcmg.2008.06.003

PubMed Abstract | CrossRef Full Text | Google Scholar

Wu, T., Jiang, B., Wang, Y., Yin, A., Huang, C., Wang, S., et al. (2015). Electrospun poly(L-lactide-co-caprolactone)–collagen–chitosan vascular graft in a canine femoral artery model. J Mater. Chem. B 3, 5760–5768. doi: 10.1039/C5TB00599J

CrossRef Full Text | Google Scholar

Wystrychowski, W., Mcallister, T. N., Zagalski, K., Dusserre, N., Cierpka, L., and L’heureux, N. (2014). First human use of an allogeneic tissue-engineered vascular graft for hemodialysis access. J. Vasc. Surg. 60, 1353–1357. doi: 10.1016/j.jvs.2013.08.018

PubMed Abstract | CrossRef Full Text | Google Scholar

Yanni, A. E. (2004). The laboratory rabbit: an animal model of atherosclerosis research. Lab. Anim. 38, 246–256. doi: 10.1258/002367704323133628

PubMed Abstract | CrossRef Full Text | Google Scholar

Yao, Y., Wang, J., Cui, Y., Xu, R., Wang, Z., Zhang, J., et al. (2014). Effect of sustained heparin release from PCL/chitosan hybrid small-diameter vascular grafts on anti-thrombogenic property and endothelialization. Acta Biomater. 10, 2739–2749. doi: 10.1016/j.actbio.2014.02.042

PubMed Abstract | CrossRef Full Text | Google Scholar

Yin, R. X., Yang, D. Z., and Wu, J. Z. (2014). Nanoparticle drug- and gene-eluting stents for the prevention and treatment of coronary restenosis. Theranostics 4, 175–200. doi: 10.7150/thno.7210

PubMed Abstract | CrossRef Full Text | Google Scholar

Yu, J., Wang, A., Tang, Z., Henry, J., Li-Ping Lee, B., Zhu, Y., et al. (2012). The effect of stromal cell-derived factor-1alpha/heparin coating of biodegradable vascular grafts on the recruitment of both endothelial and smooth muscle progenitor cells for accelerated regeneration. Biomaterials 33, 8062–8074. doi: 10.1016/j.biomaterials.2012.07.042

PubMed Abstract | CrossRef Full Text | Google Scholar

Zago, A. C., Raudales, J. C., Attizzani, G., Matte, B. S., Yamamoto, G. I., Balvedi, J. A., et al. (2013). Local delivery of sirolimus nanoparticles for the treatment of in-stent restenosis. Catheter. Cardiovasc. Interv. 81, E124–E129. doi: 10.1002/ccd.24331

PubMed Abstract | CrossRef Full Text | Google Scholar

Zeng, W., Wen, C., Wu, Y., Li, L., Zhou, Z., Mi, J., et al. (2012). The use of BDNF to enhance the patency rate of small-diameter tissue-engineered blood vessels through stem cell homing mechanisms. Biomaterials 33, 473–484. doi: 10.1016/j.biomaterials.2011.09.066

PubMed Abstract | CrossRef Full Text | Google Scholar

Zeng, W., Yuan, W., Li, L., Mi, J., Xu, S., Wen, C., et al. (2010). The promotion of endothelial progenitor cells recruitment by nerve growth factors in tissue-engineered blood vessels. Biomaterials 31, 1636–1645. doi: 10.1016/j.biomaterials.2009.11.037

PubMed Abstract | CrossRef Full Text | Google Scholar

Zhang, H., Jia, X., Han, F., Zhao, J., Zhao, Y., Fan, Y., et al. (2013). Dual-delivery of VEGF and PDGF by double-layered electrospun membranes for blood vessel regeneration. Biomaterials 34, 2202–2212. doi: 10.1016/j.biomaterials.2012.12.005

PubMed Abstract | CrossRef Full Text | Google Scholar

Zhou, M., Liu, Z., Liu, C., Jiang, X., Wei, Z., Qiao, W., et al. (2012). Tissue engineering of small-diameter vascular grafts by endothelial progenitor cells seeding heparin-coated decellularized scaffolds. J. Biomed. Mater. Res. B Appl. Biomater. 100, 111–120. doi: 10.1002/jbm.b.31928

PubMed Abstract | CrossRef Full Text | Google Scholar

Zhu, X., Xie, H., Liang, X., Li, X., Duan, J., Chen, Y., et al. (2017). Bilayered nanoparticles with sequential release of VEGF gene and paclitaxel for restenosis inhibition in atherosclerosis. ACS Appl. Mater. Interfaces 9, 27522–27532. doi: 10.1021/acsami.7b08312

PubMed Abstract | CrossRef Full Text | Google Scholar

Zilla, P., Fasol, R., Preiss, P., Kadletz, M., Deutsch, M., Schima, H., et al. (1989). Use of fibrin glue as a substrate for in vitro endothelialization of PTFE vascular grafts. Surgery 105, 515–522.

PubMed Abstract | Google Scholar

Keywords: drug delivery, vascular tissue engineering, vascular graft, vascular repair, drug eluting stent, nanoparticle, aneurysm

Citation: Strobel HA, Qendro EI, Alsberg E and Rolle MW (2018) Targeted Delivery of Bioactive Molecules for Vascular Intervention and Tissue Engineering. Front. Pharmacol. 9:1329. doi: 10.3389/fphar.2018.01329

Received: 15 March 2018; Accepted: 29 October 2018;
Published: 21 November 2018.

Edited by:

Chris A. Bashur, Florida Institute of Technology, United States

Reviewed by:

Blanka Sharma, University of Florida, United States
Hui Li, University of California, San Francisco, United States

Copyright © 2018 Strobel, Qendro, Alsberg and Rolle. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

*Correspondence: Marsha W. Rolle, mrolle@wpi.edu

Present address: Eben Alsberg, Departments of Bioengineering and Orthopaedics, The University of Illinois, Chicago, IL, United States

Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.