Screening of the Previous Photorefractive Surgery Using the Minimum Distance Between the Anterior Best Fit Sphere and the Center of the Anterior Corneal Surface.
Lee Hoo Kim, Jae Hwan Lee, Jung Hyub Oh
Department of Ophthalmology, Inha University College of Medicine, Incheon, Korea. jhoh9707@hanmail.net
근시교정 각막굴절수술 선별검사를 위한 각막전면중심점과 각막전면최적구면 사이의 최소거리의 의의
김이후ㆍ이재환ㆍ오중협
Department of Ophthalmology, Inha University College of Medicine, Incheon, Korea
Correspondence:  Lee Hoo Kim, M.D.
Abstract
PURPOSE
To develop a screening test based on the difference (Diff) between the anterior corneal surface and the anterior best fit sphere in the central region of the Orbscan IIz topography as a way of detecting previous myopic photorefractive surgery. METHODS: From 1623 patients who had no refractive surgery and no corneal disease, 3132 topographies were defined as normal. From 120 patients who had Orbscan IIz topography after myopic photorefractive surgery, 238 topographies were defined as eyes that had undergone refractive surgery. The first objective was to determine the difference (Diff) between the anterior corneal surface and the anterior best fit sphere in the central region. The second objective was to classify the anterior elevation map of Orbscan IIz topography. RESULTS: The Diff value of the center of the anterior cornea surface averaged 0.008+/-0.003 mm in normal eyes, and all values were over 0 mm. However, in eyes that had previous refractive surgery, the average was 0.014+/-0.009 mm, and all values in this group were less than 0. The specificity and sensitivity was 100 % in both groups. The spherical equivalent of the degree of myopic correction and the Diff value of the center of the anterior cornea surface showed a linear relationship. Consequently, we could derive a formula to determine the degree of myopic correction with a known Diff value of the center of the anterior corneal surface. CONCLUSIONS: The screening test, based on the Diff value of Orbscan IIz topography, is quite useful in determining whether an eye has undergone previous myopic photorefractive surgery.
Key Words: Difference;Orbscan;Photorefractive;Screening
TOOLS
METRICS Graph View
  • 0 Crossref
  •  0 Scopus
  • 585 View
  • 6 Download
Related articles


ABOUT
BROWSE ARTICLES
EDITORIAL POLICY
FOR CONTRIBUTORS
Editorial Office
SKY 1004 Building #701
50-1 Jungnim-ro, Jung-gu, Seoul 04508, Korea
Tel: +82-2-583-6520    Fax: +82-2-583-6521    E-mail: kos08@ophthalmology.org                

Copyright © 2024 by Korean Ophthalmological Society.

Developed in M2PI

Close layer
prev next