Elsevier

Journal of Dairy Science

Volume 94, Issue 12, December 2011, Pages 6243-6256
Journal of Dairy Science

Consequence of alternative standards for bulk tank somatic cell count of dairy herds in the United States

https://doi.org/10.3168/jds.2011-4645Get rights and content
Under a Creative Commons license
open access

Abstract

Noncompliance with current US and European Union (EU) standards for bulk-tank somatic cell count (BTSCC) as well as BTSCC standards recently proposed by 3 US organizations was evaluated using US Dairy Herd Improvement Association (DHI) herds and herds supplying milk to 4 Federal Milk Marketing Orders (FMO). Herds with 15 to 26 tests (frequently monthly) from January 2009 through October 2010 were included. Somatic cell scores (SCS) from 14,854 herds and 164,794 herd-tests were analyzed for DHI herds with ≥10 cows for all tests. Herd test-day SCC was derived as a proxy for BTSCC and was the basis for determining noncompliance and percentage of the milk it represented. For FMO herds, actual milk marketed and BTSCC were available from 27,759 herds and 325,690 herd-tests. A herd was noncompliant for the current EU BTSCC standard after 4 consecutive rolling 3-test geometric means (geometric method) were >400,000 cells/mL. A herd was noncompliant for the current US BTSCC standard after 3 of 5 consecutive monthly BTSCC shipments (frequency method) were >750,000 cells/mL. Alternative proposed standards (600,000, 500,000, or 400,000 cells/mL) also were examined. A third method designated noncompliance when a single 3-mo geometric mean of >550,000 or >400,000 cells/mL and a subsequent test exceeded the same level. Results were examined based on herd size or milk shipped by month. Noncompliance for the current US standard for the 12 mo ending October 2010 in DHI and FMO herds was 0.9 and 1.0%, respectively, compared with 7.8 and 16.1% for the current EU standard. Noncompliance was always greater for the frequency method than for the geometric method and was inversely related to herd size or milk shipped. Using the frequency method at 400,000 cells/mL, noncompliance was 19.1% for DHI herd-tests in herds with <50 cows compared with 1.1% for herds with ≥1,000 cows. For FMO herds shipping <900 t, noncompliance was 44.5% using the frequency method at 400,000 cells/mL compared with 8.0% for herds marketing >9,000 t. All methods proposed increased the percentages of herds and shipped milk that exceeded the regulatory limit. Producers will need to place more emphasis on reducing the incidence and prevalence of subclinical mastitis through known management practices such as proper milking techniques, well-functioning milking machines, postmilking teat disinfectant, dry cow treatment, and culling of problem cows to meet any of the proposed new standards.

Key words

European Union
milk quality
somatic cell count
standard

Cited by (0)