Skip to content
Licensed Unlicensed Requires Authentication Published by De Gruyter March 21, 2015

Tarapur atomic power station: analysis of station blackout scenario

KKW Tarapur: Untersuchungen zum langanhaltenden Notstromfall
  • A. Srivastava , A. D. Contractor , H. G. Lele and K. K. Vaze
From the journal Kerntechnik

Abstract

India is currently operating two BWR built by General Electric Company. The design features of these reactors are similar to the Fukushima's BWR except some better containment features in Indian BWR. This paper discusses the enveloping scenario of station blackout of infinite duration with no operator action and no component failure. The paper describes the details of modelling the TAPS-BWR plant model including SCDAP modelling of reactor core in system code RELAP5 and further thermal hydraulic safety assessment of station blackout scenario. The analysis brought out effectively the response of the plant to this high-pressure severe accident scenario. The time line of the severe accident progression will give details of various stages of accident progression along with hydrogen generation, which will be useful in evolving suitable severe accident management guidelines.

Kurzfassung

In diesem Beitrag werden Rechnungen mit RELAP5/SCDAP zum Notstromfall in den zwei KKW Tarapur vorgestellt. Beide KKW sind Siedewasserreaktoren und wurden von General Electric errichtet. Das Design ähnelt den SWR in Fukushima. Der zeitliche Ablauf des gewählten Szenarios wird im Beitrag vorgestellt.


* E-mail:

References

1 Katiyar, S. C.; Baja, S. S.: Tarapur Atomic Power Station Units-1 and 2 Design features, operating experience and license renewal. Nuclear Engineering and Design236 (2006) 88189310.1016/j.nucengdes.2005.09.034Search in Google Scholar

2 Kaliatka, A.; Urbonavicius, E.; Uspuras, E.: Approach to accident management in RBMK-1500. Nuclear Engineering and Design238 (2008) 24124910.1016/j.nucengdes.2007.06.003Search in Google Scholar

3 Andreeva, M.; Pavlova, M. P.; Groudev, P. P.: Overview of plant specific Severe Accident Management strategies for Kozlouduy Nuclear Power Plant WWER-1000/320. Annals of Nuclear Energy35 (2008) 55556410.1016/j.anucene.2007.08.005Search in Google Scholar

4 Fletcher, C. D.; et al.: RELAP5/MOD3.2 Code Manual, Volume I: Code Structure, Systems Models and Solution Methods. NUREG/CR-5535, INEL-95/0174, 1995Search in Google Scholar

5 CoryellE.W.; et al.: SCDAP/RELAP5/MOD3.2 Code Manual, Volume II: Damage Progression Model Theory. NUREG/CR-6150, INEL-96/0422, 1997Search in Google Scholar

6 HarvegoE.A.; et al.: SCDAP/RELAP5/MOD3.2 Code Manual, Volume V: Developmental Assessment. NUREG/CR-6150, INEL-96/0422, 1997Search in Google Scholar

Received: 2014-04-30
Published Online: 2015-03-21
Published in Print: 2015-03-17

© 2015, Carl Hanser Verlag, München