Bilateral sweat tests with two different methods as a part of cystic fibrosis newborn screening (CF NBS) protocol and additional quality control.

Dorota Sands, Mariusz Ołtarzewski, Anna Nowakowska, Katarzyna Zybert
DOI: 10.2478/v10042-010-0044-9
·
Folia Histochem Cytobiol 2010;48(3):358-365.

open access

Vol 48, No 3 (2010)
ORIGINAL PAPERS
Submitted: 2011-12-19
Published online: 2010-11-13

Abstract

Infants with positive CF newborn screening (NBS) results are called to a CF Centre for verification. Those, in whom the sweat test is elevated, undergo further medical procedures. The aim of our study was to evaluate the applicability of Nanoduct - a new system measuring sweat conductivity and giving immediate results in a CF NBS protocol. Measurements with Nanoduct were compared with the classic pilocarpine method. During 3 years 487 infants from CF NBS had both sweat tests performed on the same day, at the same CF centre. CF infants had a mean conductivity of 99.8 Âą 1 8.8 mmol/L and a mean chloride concentration of 74.0 Âą 18.4 mmol/L. Non-CF infants values were 29.8 Âą 7.7 mmol/L and 19.2 Âą 6.6 mmol/L respectively. A good correlation between both tests was found (95% confidence level (CI); r=0.87). The optimal cut off, based on follow up experience of screened children, for conductivity tests was 50 mmol/L and for chloride concentration was 34 mmol/L (no lost CF, 11 false positive) with 100% sensitivity and 97.5 % specificity. In conclusion Nanoduct is a very useful and reliable tool in CF NBS protocol, allowing more time efficient organization of the diagnostic and training procedures. Simultaneous bilateral sweat testing with two different methods (concentration and conductivity) provides an extra quality control system.

Abstract

Infants with positive CF newborn screening (NBS) results are called to a CF Centre for verification. Those, in whom the sweat test is elevated, undergo further medical procedures. The aim of our study was to evaluate the applicability of Nanoduct - a new system measuring sweat conductivity and giving immediate results in a CF NBS protocol. Measurements with Nanoduct were compared with the classic pilocarpine method. During 3 years 487 infants from CF NBS had both sweat tests performed on the same day, at the same CF centre. CF infants had a mean conductivity of 99.8 Âą 1 8.8 mmol/L and a mean chloride concentration of 74.0 Âą 18.4 mmol/L. Non-CF infants values were 29.8 Âą 7.7 mmol/L and 19.2 Âą 6.6 mmol/L respectively. A good correlation between both tests was found (95% confidence level (CI); r=0.87). The optimal cut off, based on follow up experience of screened children, for conductivity tests was 50 mmol/L and for chloride concentration was 34 mmol/L (no lost CF, 11 false positive) with 100% sensitivity and 97.5 % specificity. In conclusion Nanoduct is a very useful and reliable tool in CF NBS protocol, allowing more time efficient organization of the diagnostic and training procedures. Simultaneous bilateral sweat testing with two different methods (concentration and conductivity) provides an extra quality control system.
Get Citation
About this article
Title

Bilateral sweat tests with two different methods as a part of cystic fibrosis newborn screening (CF NBS) protocol and additional quality control.

Journal

Folia Histochemica et Cytobiologica

Issue

Vol 48, No 3 (2010)

Article type

Original paper

Pages

358-365

Published online

2010-11-13

Page views

2549

Article views/downloads

3314

DOI

10.2478/v10042-010-0044-9

Bibliographic record

Folia Histochem Cytobiol 2010;48(3):358-365.

Authors

Dorota Sands
Mariusz Ołtarzewski
Anna Nowakowska
Katarzyna Zybert

Regulations

Important: This website uses cookies. More >>

The cookies allow us to identify your computer and find out details about your last visit. They remembering whether you've visited the site before, so that you remain logged in - or to help us work out how many new website visitors we get each month. Most internet browsers accept cookies automatically, but you can change the settings of your browser to erase cookies or prevent automatic acceptance if you prefer.

By VM Media Group sp z o.o., ul. Świętokrzyska 73, 80–180 Gdańsk

tel.:+48 58 320 94 94, faks:+48 58 320 94 60, e-mail:  viamedica@viamedica.pl