JOURNAL TOOLS |
Publishing options |
eTOC |
To subscribe |
Submit an article |
Recommend to your librarian |
ARTICLE TOOLS |
Publication history |
Reprints |
Permissions |
Cite this article as |
Share |
YOUR ACCOUNT
YOUR ORDERS
SHOPPING BASKET
Items: 0
Total amount: € 0,00
HOW TO ORDER
YOUR SUBSCRIPTIONS
YOUR ARTICLES
YOUR EBOOKS
COUPON
ACCESSIBILITY
ORIGINAL ARTICLE BODY COMPOSITION, NUTRITION AND SUPPLEMENTATION
The Journal of Sports Medicine and Physical Fitness 2020 February;60(2):251-6
DOI: 10.23736/S0022-4707.19.09985-7
Copyright © 2019 EDIZIONI MINERVA MEDICA
language: English
Prediction of body fat in male athletes from ultrasound and anthropometric measurements versus DXA
Jean-Claude PINEAU ✉, Mustapha BOUSLAH
Faculty of Dental Surgery, Paris-Descartes University, Montrouge, France
BACKGROUND: To compare the accuracy of body fat percentage (BF%) measured by an ultrasound portable device and anthropometric measurements with a Dual energy X-ray absorptiometry (DXA) as the reference technique in male athletes.
METHODS: A total of 100 athletes: 16 boxers, 4 rowers, 5 gymnasts, 6 base ball players, 19 judo players, 10 taekwondo players, 7 basket-ball players, 21 wrestlers, 6 cyclists on track and 6 karate expert aged from 18 to 30 years participated. All athletes were selected from the French National Institute of Sports and Physical Education. Ultrasound measurements were made with a sonographic US BOX at the mid-thigh level. We developed a multi -linear model of body fat estimation from ultrasound and anthropometric dimensions (height, weight, waist circumference) using the DXA reference method. A cross-validation study was then performed with this linear regression on 62 males athletes proportionally stratified across the sports.
RESULTS: The best accuracy of BF was obtained using a multi-linear model from ultrasonic and anthropometric measurements with a concordance correlation ρc=0.941. This model was then used to estimate BF on the 62 males athletes. The concordance correlation ρc=0.931 and SEE=1.60. The 95% limits of agreement for individual BF% were [-4.1;3.6%] with symmetrically distributed deviations.
CONCLUSIONS: Comparing to DXA, ultrasonic and anthropometric measurements are both accurate techniques to estimates BF%. Our results suggest that this regression model is practical to apply to different sports.
KEY WORDS: Body fat distribution; Ultrasonography; Anthropometry; Absorptiometry, photon; Athletes; Male