Home > Journals > The Journal of Sports Medicine and Physical Fitness > Past Issues > The Journal of Sports Medicine and Physical Fitness 2020 February;60(2) > The Journal of Sports Medicine and Physical Fitness 2020 February;60(2):251-6

CURRENT ISSUE
 

JOURNAL TOOLS

Publishing options
eTOC
To subscribe
Submit an article
Recommend to your librarian
 

ARTICLE TOOLS

Publication history
Reprints
Permissions
Cite this article as
Share

 

ORIGINAL ARTICLE  BODY COMPOSITION, NUTRITION AND SUPPLEMENTATION 

The Journal of Sports Medicine and Physical Fitness 2020 February;60(2):251-6

DOI: 10.23736/S0022-4707.19.09985-7

Copyright © 2019 EDIZIONI MINERVA MEDICA

language: English

Prediction of body fat in male athletes from ultrasound and anthropometric measurements versus DXA

Jean-Claude PINEAU , Mustapha BOUSLAH

Faculty of Dental Surgery, Paris-Descartes University, Montrouge, France



BACKGROUND: To compare the accuracy of body fat percentage (BF%) measured by an ultrasound portable device and anthropometric measurements with a Dual energy X-ray absorptiometry (DXA) as the reference technique in male athletes.
METHODS: A total of 100 athletes: 16 boxers, 4 rowers, 5 gymnasts, 6 base ball players, 19 judo players, 10 taekwondo players, 7 basket-ball players, 21 wrestlers, 6 cyclists on track and 6 karate expert aged from 18 to 30 years participated. All athletes were selected from the French National Institute of Sports and Physical Education. Ultrasound measurements were made with a sonographic US BOX at the mid-thigh level. We developed a multi -linear model of body fat estimation from ultrasound and anthropometric dimensions (height, weight, waist circumference) using the DXA reference method. A cross-validation study was then performed with this linear regression on 62 males athletes proportionally stratified across the sports.
RESULTS: The best accuracy of BF was obtained using a multi-linear model from ultrasonic and anthropometric measurements with a concordance correlation ρc=0.941. This model was then used to estimate BF on the 62 males athletes. The concordance correlation ρc=0.931 and SEE=1.60. The 95% limits of agreement for individual BF% were [-4.1;3.6%] with symmetrically distributed deviations.
CONCLUSIONS: Comparing to DXA, ultrasonic and anthropometric measurements are both accurate techniques to estimates BF%. Our results suggest that this regression model is practical to apply to different sports.


KEY WORDS: Body fat distribution; Ultrasonography; Anthropometry; Absorptiometry, photon; Athletes; Male