Case Report

Intraoperative Optical Coherence Tomography-guided 25G Microamount Trajectory Vitrectomy for the Treatment of Penetrating Ocular Injury Caused by a Foreign Body in the Right Eye: A Case Study

Author(s): Yuan Wang, Shengyu Wang, Xingxing Zhao, Xin Lu, Tiantian Wang, Wenjun Chen and Zhaojiang Du*

Volume 18, Issue 13, 2022

Published on: 11 August, 2022

Article ID: e120522204689 Pages: 6

DOI: 10.2174/1573405618666220512160302

Price: $65

Abstract

Background: Optical coherence tomography (OCT) is a real-time three-dimensional tomography optical imaging technology that uses near-infrared waves to take cross-sectional pictures of the retina and other tissues. A few studies have reported the use of intraoperative OCT navigation for the removal of foreign bodies from the eyeball during surgery. The objective is to present a single case with a small foreign body (not embedded in the retina) treated with intraoperative OCT guided 25G micro-amount trajectory vitrectomy.

Case Presentation: The examination of a 25-year-old man, who suffered from right eye pain, suggested the following: the visual acuity was 20/250, the intraocular pressure was 8 mmHg, a scleral penetrating wound was visible at 3 mm behind the limbus at 7 o' clock, and Tyn (+). The vitreous showed some flocculent turbidity, the retina was flat, and the foreign body was visible at 10 o' clock. On the day of admission, the patient underwent a micro-amount vitrectomy with the removal of the foreign body. The vitreous body affected by the foreign body was then removed through the original wound track by using intraoperative OCT navigation.

Conclusion: The final follow-up showed the best-corrected vision of the right eye as 20/25 andno occurrence of complications. The intraoperative OCT-guided 25G micro-amount trajectory vitrectomy could be used as an accurate, useful, and safe method for foreign body extraction.

Keywords: Intraoperative optical coherence tomography, vitrectomy, ophthalmology, case report, ICL, retina.

Graphical Abstract
[1]
Spînu M, Olinic DM, Olinic M, Homorodean C. In vivo imaging of complicated atherosclerotic plaque - role of optical coherence tomogra-phy (OCT). Rom J Morphol Embryol 2018; 59(2): 469-78.
[PMID: 30173250]
[2]
Augustin AJ. [Intraoperative optical coherence tomography - an overview of current clinical data for the application in the anterior and posterior segments]. Klin Monatsbl Augenheilkd 2018; 235(7): 820-9.
[PMID: 28187469]
[3]
Loporchio D, Mukkamala L, Gorukanti K, Zarbin M, Langer P, Bhagat N. Intraocular foreign bodies: A review. Surv Ophthalmol 2016; 61(5): 582-96.
[http://dx.doi.org/10.1016/j.survophthal.2016.03.005] [PMID: 26994871]
[4]
Dhoble P, Khodifad A. Combined cataract extraction with pars plana vitrectomy and metallic intraocular foreign body removal through sclerocorneal tunnel using a novel “Magnet Handshake” technique. Asia Pac J Ophthalmol (Phila) 2018; 7(2): 114-8.
[PMID: 28868832]
[5]
Ozdamar Erol Y, Tekin K, Yilmazbas P. 23-gauge transconjunctival vitrectomy for posterior segment intraocular foreign bodies. Ulus Travma Acil Cerrahi Derg 2019; 25(3): 298-302.
[PMID: 31135941]
[6]
Ozkaya A, Cakir I, Tarakcioglu HN. The outcomes of bimanual posterior segment intraocular foreign body removal with vitrectomy and description of two different handshake techniques: A single surgeon case series. J Fr Ophtalmol 2019; 42(2): 109-17.
[http://dx.doi.org/10.1016/j.jfo.2018.08.001] [PMID: 30679130]
[7]
Zhang Z, Zhou JL, Wang F. [An analysis of intraocular metallic foreign body injury during hammer percussion]. Zhonghua Lao Dong Wei Sheng Zhi Ye Bing Za Zhi 2017; 35(12): 942-3.
[PMID: 29495162]
[8]
Falavarjani KG, Hashemi M, Modarres M, et al. Vitrectomy for posterior segment intraocular foreign bodies, visual and anatomical out-comes. Middle East Afr J Ophthalmol 2013; 20(3): 244-7.
[http://dx.doi.org/10.4103/0974-9233.114803] [PMID: 24014990]
[9]
Nicoară SD, Irimescu I, Călinici T, Cristian C. Intraocular foreign bodies extracted by pars plana vitrectomy: Clinical characteristics, management, outcomes and prognostic factors. BMC Ophthalmol 2015; 15(1): 151.
[http://dx.doi.org/10.1186/s12886-015-0128-6] [PMID: 26526732]
[10]
Takashina H, Watanabe A, Tsuneoka H. Investigation of postoperative intraocular pressure in cases of silicone oil removal using 25-gauge transconjunctival sutureless vitrectomy with oblique incisions. Clin Ophthalmol 2015; 9: 1925-8.
[http://dx.doi.org/10.2147/OPTH.S93376] [PMID: 26508831]
[11]
Mancino R, Aiello F, Ciuffoletti E, Di Carlo E, Cerulli A, Nucci C. Inferior retinotomy and silicone oil tamponade for recurrent inferior retinal detachment and grade C PVR in eyes previously treated with pars plana vitrectomy or scleral buckle. BMC Ophthalmol 2015; 15(1): 173.
[http://dx.doi.org/10.1186/s12886-015-0167-z] [PMID: 26645589]
[12]
Ung C, Miller JB. Intraoperative optical coherence tomography in vitreoretinal surgery. Semin Ophthalmol 2019; 34(4): 312-6.
[http://dx.doi.org/10.1080/08820538.2019.1620811] [PMID: 31240975]
[13]
Khan M, Ehlers JP. Clinical utility of intraoperative optical coherence tomography. Curr Opin Ophthalmol 2016; 27(3): 201-9.
[http://dx.doi.org/10.1097/ICU.0000000000000258] [PMID: 26918786]
[14]
Nishitsuka K, Nishi K, Namba H, Kaneko Y, Yamashita H. Intraoperative optical coherence tomography imaging of the peripheral vitreous and retina. Retina 2018; 38(3): e20-2.
[http://dx.doi.org/10.1097/IAE.0000000000001979] [PMID: 29210938]
[15]
Casini G, Sartini F, Loiudice P, Benini G, Menchini M. Ocular siderosis: A misdiagnosed cause of visual loss due to ferrous intraocular foreign bodies-epidemiology, pathogenesis, clinical signs, imaging and available treatment options. Doc Ophthalmol 2021; 142(2): 133-52.
[http://dx.doi.org/10.1007/s10633-020-09792-x] [PMID: 32949328]
[16]
Sagar P, Biswal S, Shankar Hn R. Swept-Source OCT findings in ocular siderosis. Ophthalmol Retina 2021; 5(5): 485.
[http://dx.doi.org/10.1016/j.oret.2021.02.011] [PMID: 33962758]

Rights & Permissions Print Cite
© 2024 Bentham Science Publishers | Privacy Policy