Title: Axial Load Tests of Concrete Compression Members with High Strength Spiral Reinforcement
Date: March-April, 2000
Volume: 45
Issue: 2
Page number: 64-80
Author(s): Stephen Pessiki, Benjamin A. Graybeal
https://doi.org/10.15554/pcij.03012000.64.80

Click here to access the full journal article

Abstract

Axial load tests were performed to evaluate the confinement effectiveness of high strength spiral reinforcement in concrete compression members. The tests included 24 and 14 in. (610 and 356 mm) diameter circular cross section compression members with spiral nominal yield strengths that ranged from 78 to 140 ksi (538 to 965 MPa). It was found that while spiral steel stresses in excess of 60 ksi (414 MPa) are achieved, the nominal yield strength of the spiral may not be achieved. The stress reached in the spiral depends in part upon the compression member diameter, with smaller diameter
members able to reach a greater fraction of the nominal yield strength as compared to the larger diameter members. For a given concrete cover thickness, these smaller diameter members have a greater volume fraction of spiral reinforcement as compared to larger diameter members. Compression members made with high strength spirals exhibit the same ductile axial load-axial shortening behavior expected from members made with mild steel spirals.

References

1. ACT Committee 318, “Building Code Requirements for Structural Concrete (ACI 318-95) and Commentary (ACI 31 8R-95),” American Concrete Institute, Farmington Hills, MI, 1995.

2. AASHTO, AASHTO LRFD Bridge Design Specifications, American As sociation of State Highway and Transportation Officials, Washington, D.C., First Edition, 1994.

3. Graybeal, B. A., “Confinement Effectiveness of High Strength Spiral Reinforcement in Prestressed Concrete Piles,” M.S. Thesis, Department of Civil and Environmental Engineering, Lehigh University, Bethlehem, PA, May 1998, 228 pp.

4. Graybeal, B., and Pessiki, S., “Confinement Effectiveness of High Strength Spiral Reinforcement in Prestressed Concrete Piles,” Report No. 98-01, Center for Advanced Technology for Large Structural Systems, Lehigh University, Bethlehem, PA, April 1998, 168 pp. 5. Considère, A., “Resistance a la compression du bèton armè et du bèton frettè,” Genie Civil, Paris, France, 1903.

6. Richart, F. E., Brandzaeg, A., and Brown, R.L., “A Study of the Failure of Concrete Under Combined Compressive Stresses,” University of Illinois Bulletin, V. 26, No. 12, November 20, 1928, 104 pp.

7. Richart, F. E., Brandzaeg, A., and Brown, R.L., “The Failure of Plain and Spirally Reinforced Concrete in Compression,” University of Illinois Bulletin, V. 26, No. 31, April 2, 1929, p7p4.

8. Richart, F. E., Brandzaeg, A., and Brown, R. L., “An Investigation of Reinforced Concrete Columns,” University of Illinois Bulletin, V. 31, No. 40, June 5, 1934, 94 pp.

9. PCI Design Handbook — Precast and Prestressed Concrete, Fifth Edition, Precast/Prestressed Concrete Institute, Chicago, IL, 1999.

10. Martinez, S., Nilson, A. H., and Slate, F. O., “Spirally Reinforced High-Strength Concrete Columns,” ACI Journal, V. 81, No. 5, September-October 1984, pp. 43 1-442.

11. Pessiki, S., and Pieroni, A. M., “Axial Load Behavior of Large-Scale Spirally-Reinforced High-Strength Concrete Columns,” ACI Structural Journal, V. 94, No. 3, May-June 1997, pp. 304-314.

12. Mudlock, M., “Design of High Strength Spiral Reinforcement for Prestressed Concrete Piles,” MS. Thesis, Department of Civil and Environmental Engineering, Lehigh University, Bethlehem, PA, July 1999, 185 pp.

13. Mudlock, M., and Pessiki, S., “Design of High Strength Spiral Reinforcement for Prestressed Concrete Piles,” Report No. 99-12, Center for Advanced Technology for Large Structural Systems, Lehigh University, Bethlehem, PA, July 1999, 134 pp.