Chun: Ultrasonographic evaluation of complications related to transfemoral arterial procedures

Abstract

The transfemoral arterial approach is used to gain access for angiography, percutaneous coronary interventions, or various endovascular therapies. To decrease the risk of procedure-related vascular complications, it is recommended to puncture the common femoral artery in its middle segment. However, due to inadequate access or anatomical variability, various complications, including hematoma, pseudoaneurysm, arteriovenous fistula, thrombosis, or dissection, can occur after transfemoral arterial interventions. Duplex ultrasound has proven to be an excellent noninvasive modality that provides not only anatomic but also hemodynamic information, effectively detecting and differentiating various femoral puncture-related complications. Radiologists should be familiar with the characteristic sonographic findings of the entire spectrum of transfemoral puncture-related vascular complications for early detection and proper treatment.

Introduction

The common femoral artery (CFA) has a relatively large diameter, is located superficially, and can be easily compressed to achieve hemostasis; therefore, the transfemoral arterial approach is the most common mode of vascular access for angiography, percutaneous coronary interventions, or various endovascular therapies such as transcatheter aortic valve replacement. The incidence of femoral puncture-related complications has been reported to be 0.44%-1.8% during diagnostic angiography and up to 4% during interventional procedures [1]. Although there are various factors that can cause complications, such as old age, female gender, lower body surface area, type of procedure, status of the peripheral vasculature, or use of anticoagulants, the most common causes of puncture-related complications are inadequate access and anatomical variability [1]. To reduce the risk of procedure-related vascular complications, the recommended puncture site is the middle segment of the CFA (Fig. 1) [2]. If the puncture site is too low, the incidence of pseudoaneurysms, hematomas, arteriovenous fistulae (AVFs), or limb ischemia is increased, whereas the incidence of retroperitoneal hemorrhage is increased if the puncture site is too high [3]. Other complications such as thrombosis, aortic dissection, or extravasation may occur after transfemoral arterial interventions. Fluoroscopic guidance can help to localize the ideal puncture site of the vessel, which is over the lower half of the femoral head.
Duplex ultrasound, which consists of gray-scale and color Doppler ultrasound, has proven to be an excellent noninvasive modality that provides not only anatomic but also hemodynamic information [4]. Although ultrasonography has limited utility for evaluating patients with a poor echo window due to obesity or a large swelling, it should be used to establish a preliminary diagnosis, especially for patients with a palpable mass or an audible bruit. This article examines the findings from gray-scale and color Doppler images of various transfemoral puncture-related complications, including thrombosis, hematoma, pseudoaneurysm, AVF, or arterial dissection. Radiologists should be familiar with the characteristic sonographic findings of the entire spectrum of transfemoral puncture-related vascular complications for early detection and proper treatment.

Hematomas

A perivascular hematoma is the result of a local hemorrhage of an injured vessel into the adjacent soft tissue. Clinically, it presents as a nonpulsatile mass or ecchymosis at the puncture site. Gray-scale sonographic images of a perivascular hematoma show a softtissue mass with varying echogenicity in the inguinal area, adjacent to the femoral artery [4]. The echogenicity of a hematoma may vary depending on how long it has been hemorrhaging; therefore, it can be mistaken for a cyst or solid mass (Fig. 2). Sometimes, in cases where a hematoma is of an intermediate age, it may be difficult to detect because the border is unclear due to ill-defined infiltration and an isoechoic echogenicity that is similar to surrounding tissue (Fig. 3). Color and pulsed Doppler ultrasound examinations typically demonstrate no internal blood flow, which allows it to be definitively differentiated from a pseudoaneurysm [4]. A hematoma usually resolves in 2-3 weeks, although sometimes it can take much longer. Therefore, serial follow-up ultrasounds and a history of recent transfemoral approach may be helpful for distinguishing a hematoma from cysts or solid masses.

Pseudoaneurysm

A pseudoaneurysm, also known as a false aneurysm, is defined as a collection of blood that forms between one or two outer layers of an artery (media or adventitia). This is distinct from a true aneurysm, which involves of all three layers of the arterial wall. The trigger event is usually a laceration of the arterial wall due to trauma during cannulation. Although the clinical presentation of pseudoaneurysms varies depending on their size and location, including pain due to increased pressure from swelling or nerve compression, pulsatile masses with a thrill or murmur or groin expansion are the common clinical manifestations. The incidence of pseudoaneurysms is estimated to be 0.05%-0.50% of all patients treated with diagnostic and therapeutic percutaneous arterial and coronary catheterizations [5]. Despite the low incidence, pseudoaneurysms may cause significant morbidity due to an increased risk of rupture, thromboembolism, extrinsic compression of nearby neurovascular structures, or necrosis of overlying skin and subcutaneous tissue [1,5]. The risk factors for pseudoaneurysms are a lower femoral puncture site, larger sheath size, anticoagulation or antifibrinolytic therapy, older age, and arterial hypertension [5].
Gray-scale sonography can reveal a pulsatile anechoic saccular lesion with variable echogenicity, depending on the presence of an intraluminal thrombus. When there is no thrombus, it is anechoic; when there is a partial thrombus, it is echogenic but varies according to the age of the thrombus (Fig. 4). In addition, if the pseudoaneurysm is completely thrombosed, it may be difficult to differentiate from a hematoma. Real-time ultrasound images can reveal swirling or fluid-fluid levels within a pseudoaneurysm. Color Doppler imaging shows a bidirectional, turbulent, swirling blood-flow pattern known as the “yin-yang” sign within a pseudoaneurysm. This sign is also noted in large aneurysms with a partial thrombus, because large aneurysms and pseudoaneurysms tend to thrombose, and blood may fill only part of the lesion [6]. Therefore, the sign is created when blood on one side of an aneurysm or pseudoaneurysm travels toward the probe (red-colored blood) and blood on the other side travels away from the probe (blue-colored blood) (Fig. 4). Although this sign is helpful in differentiating aneurysms or pseudoaneurysms from hematomas, cysts, or solid masses, it is not specific to partially thrombosed aneurysms or pseudoaneurysms because some neoplasms, such as solid and papillary neoplasms, also may show the yin-yang sign [6]. With spectral Doppler interrogation, the characteristic “to-and-fro” pattern in the communicating neck between the arterial vessel and pseudoaneurysmal sac is revealed (Fig. 5). The “to” represents the arterial blood entering the pseudoaneurysmal sac during systole, while the “fro” represents blood flowing away from the pseudoaneurysmal sac during diastole [7].
Treatment options for pseudoaneurysms are observation, ultrasound-guided compression, surgical repair, and percutaneous thrombin injection. If a patient has a pseudoaneurysm that is 2 cm or smaller and is asymptomatic, observation is recommended to watch for spontaneous thrombosis [8]. Ultrasound-guided compression is used for effective compression of the tract connecting the native arterial lumen and the pseudoaneurysmal sac in asymptomatic patients who have a small pseudoaneurysm (usually less than 3.5 cm in diameter), because it has low complication rates and is cost-effective [9]. However, it is time-consuming and labor-intensive for the practitioners, and it is more likely to fail in patients undergoing anticoagulation therapy, with large or chronic pseudoaneurysms, and who have undergone a relatively long [9]. Surgical repair was the standard of care for pseudoaneurysms, but it usually required general anesthesia and resulted in perioperative complications, such as bleeding, wound infection, lymphocele, and radiculopathy [8]. Recently, percutaneous ultrasound-guided thrombin injection has become the treatment of choice for pseudoaneurysms because the technique is simple and has a high success rate of 96%, in comparison to the 74% success rate of ultrasound-guided compression [10]. A large neck diameter (>1 cm) is a relative contraindication for thrombin injection because of the higher risk of distal embolization. Under continuous ultrasound imaging, the thrombin is carefully injected in 0.1-mL increments using a thin-caliber needle (21-22G). The tip of the needle should be located in the sac, as far away from the neck as possible. Thrombi begin to form around the tip of the needle within a few seconds after thrombin injection, and then the remainder of the sac is progressively filled with thrombi (Fig. 6). When the pseudoaneurysm is filled completely, the color signal is no longer observed within the sac. During thrombin injection, it is very important that the native CFA should be assessed using ultrasound to avoid the risk of distal embolization.

Arteriovenous Fistula

An AVF is a vascular channel connecting an artery with an adjacent vein that is created by simultaneous arterial and venous injury from needle tract trauma. Multiple puncture attempts, posterior arterial wall penetration, or the use of a large puncture needle increase the risk of an AVF [3,4]. Clinically, AVFs may present with a palpable thrill over the access site and an audible bruit. Unless the communicating tract between the artery and the vein is large, it is difficult to diagnose with gray-scale ultrasound. However, color Doppler with spectral sonography can show its characteristic features. The major diagnostic criteria of AVFs include a junction of low- and high-resistance flow in the supplying artery, a high-velocity arterialized waveform in the draining vein, and a turbulent high-velocity flow spectrum at the junction of the artery and the vein (Fig. 7). The minor diagnostic criteria of AVFs are visible direct communication between the artery and vein, a significant change in the diameter of the supplying artery, a focal point of venous dilatation, and a focal perivascular color artifact [11]. When the fistula is large enough to cause arterial steal, however, the flow in the distal artery may be reversed. The high-velocity flow may also create an adjacent softtissue color bruit characterized by perivascular speckling of color Doppler signals (Fig. 8). Rarely, an AVF may occur in association with a pseudoaneurysm (Fig. 9). Usually, the pseudoaneurysm is initially created at the arterial puncture and then a second channel is created by the needle passing through the pseudoaneurysm and the adjacent vein, resulting in an AVF [4].
The management of an AVF is determined by the symptom or size of the AVF. Patients with a small AVF who are asymptomatic should be observed, as they are prone to spontaneous occlusion. Other treatments are ultrasound-guided compression, endovascular repair, and surgical ligation.

Femoral Artery Dissection

Dissections occur when a wire or catheter enters the subintimal space and creates a false lumen. Its incidence was approximately 0.1%-0.4% in patients who underwent cardiac catheterization [12]. Gray-scale ultrasound can reveal an echogenic dissection flap representing the dissected intimal layer of the arterial wall that may be found centrally within the lumen (Fig. 10). Color Doppler can show the parallel blood-flow channel that separates the true and false lumen. If the false lumen is filled by a thrombus, it is not distinguishable from an intramural hematoma or plaque. The majority of non-flow-limiting dissections can be clinically observed and will spontaneously resolve. If there is a flow-limiting dissection or associated limb ischemia, surgical repair can be performed, such as patch angioplasty or endarterectomy [12].

Arterial Thrombus/Occlusion

Up to 3% of patients who undergo transfemoral arterial interventions will experience angioplasty-site thrombosis. Ultrasound images of such thrombi show various degrees of echogenicity and internal complexity, along with an absence of color flow (Fig. 11). In a chronic thrombus, the diameter is small and there is a heterogeneous echogenic wall. Except when contraindicated by active hemorrhage, recent major surgery, or stroke within the past 6 months, thrombolytic treatment includes the use of streptokinase, urokinase, or low-molecular-weight heparinization [13].

Retroperitoneal Hemorrhage

Retroperitoneal hemorrhage is very rare, with an incidence of 0.15%-0.5% in patients who undergo cardiac catheterization; however, its mortality rate (6.6%) is high [14]. The risk factors relevant to retroperitoneal hemorrhage are anticoagulation, hypertension, a higher femoral arterial puncture site, and use of larger sheath sizes. It should be suspected when there is serial decrease in hemoglobin and clinical symptoms such as dizziness, orthostatic hypotension, and ipsilateral flank pain [14]. For the detection of retroperitoneal hemorrhage, computed tomography (CT) is more sensitive than ultrasound because the retroperitoneal space may limit the field of the echo window (Fig. 12). CT can successfully reveal the location of the bleeding, the extent of the hematoma, and other associated traumatic conditions. Although the majority of cases respond to conservative management, endovascular coil, Gelfoam embolization, or surgical repair may be required to control active bleeding [15].

Conclusion

All patients undergoing femoral arterial puncture should be promptly evaluated for potential complications because significant hemodynamic deterioration from bleeding or an AVF can lead to deleterious outcomes. Duplex ultrasound is useful for the initial evaluation of femoral puncture-related vascular lesions, because it can provide anatomic and hemodynamic information at the same time. Using color Doppler ultrasound, complications such as hematoma, pseudoaneurysm, and AVF can be distinguished. In addition, ultrasonography plays an important role in the guidance of thrombin injections, resulting in high efficacy of the procedure and reduced complications. Therefore, radiologists should be aware of the characteristic ultrasonographic findings of complications related to transfemoral arterial procedures in order to provide the proper treatment.

Conflict of Interest

No potential conflict of interest relevant to this article was reported.

Acknowledgements

The author would like to thank Hyukjoon Lee, MD, Department of Radiology, Seoul National University Hospital for contributing the image of the thrombin injection.

References

1. Chandrasekar B, Doucet S, Bilodeau L, Crepeau J, deGuise P, Gregoire J, et al. Complications of cardiac catheterization in the current era: a single-center experience. Catheter Cardiovasc Interv 2001;52:289–295.
crossref pmid
2. Irani F, Kumar S, Colyer WR Jr. Common femoral artery access techniques: a review. J Cardiovasc Med (Hagerstown) 2009;10:517–522.
crossref pmid
3. Pitta SR, Prasad A, Kumar G, Lennon R, Rihal CS, Holmes DR. Location of femoral artery access and correlation with vascular complications. Catheter Cardiovasc Interv 2011;78:294–299.
crossref pmid
4. Foshager MC, Finlay DE, Longley DG, Letourneau JG. Duplex and color Doppler sonography of complications after percutaneous interventional vascular procedures. Radiographics 1994;14:239–253.
crossref pmid
5. Kresowik TF, Khoury MD, Miller BV, Winniford MD, Shamma AR, Sharp WJ, et al. A prospective study of the incidence and natural history of femoral vascular complications after percutaneous transluminal coronary angioplasty. J Vasc Surg 1991;13:328–333.
crossref pmid
6. Lupattelli T. The yin-yang sign. Radiology 2006;238:1070–1071.
crossref pmid
7. Mahmoud MZ, Al-Saadi M, Abuderman A, Alzimami KS, Alkhorayef M, Almagli B, et al. "To-and-fro" waveform in the diagnosis of arterial pseudoaneurysms. World J Radiol 2015;7:89–99.
crossref pmid pmc
8. Franklin JA, Brigham D, Bogey WM, Powell CS. Treatment of iatrogenic false aneurysms. J Am Coll Surg 2003;197:293–301.
crossref pmid
9. Fellmeth BD, Roberts AC, Bookstein JJ, Freischlag JA, Forsythe JR, Buckner NK, et al. Postangiographic femoral artery injuries: nonsurgical repair with US-guided compression. Radiology 1991;178:671–675.
crossref pmid
10. Paulson EK, Sheafor DH, Kliewer MA, Nelson RC, Eisenberg LB, Sebastian MW, et al. Treatment of iatrogenic femoral arterial pseudoaneurysms: comparison of US-guided thrombin injection with compression repair. Radiology 2000;215:403–408.
crossref pmid
11. Li JC, Cai S, Jiang YX, Dai Q, Zhang JX, Wang YQ. Diagnostic criteria for locating acquired arteriovenous fistulas with color Doppler sonography. J Clin Ultrasound 2002;30:336–342.
crossref pmid
12. Prasad A, Compton PA, Prasad A, Roesle M, Makke L, Rogers S, et al. Incidence and treatment of arterial access dissections occurring during cardiac catheterization. J Interv Cardiol 2008;21:61–66.
crossref pmid
13. Visona A, Tonello D, Zalunardo B, Irsara S, Liessi G, Marigo L, et al. Antithrombotic treatment before and after peripheral artery percutaneous angioplasty. Blood Transfus 2009;7:18–23.
pmid pmc
14. Kent KC, Moscucci M, Mansour KA, DiMattia S, Gallagher S, Kuntz R, et al. Retroperitoneal hematoma after cardiac catheterization: prevalence, risk factors, and optimal management. J Vasc Surg 1994;20:905–910.
crossref pmid
15. Levine GN, Kern MJ, Berger PB, Brown DL, Klein LW, Kereiakes DJ, et al. Management of patients undergoing percutaneous coronary revascularization. Ann Intern Med 2003;139:123–136.
crossref pmid

The anatomy relevant to percutaneous catheterization of the femoral artery and vein.

Femoral vessels pass underneath the inguinal ligament, which connects the anterior-superior iliac spine and the pubic tubercle. Approximately one whole and one half to two fingerbreadths (3 cm) below the inguinal ligament, the area where the femoral artery pulse is felt is the appropriate arterial puncture site. The venous puncture site should be medially placed approximately at one fingerbreadth at the same level.
usg-17047-f1.gif
Fig. 1.

Hematoma of a 56-year-old man with a palpable mass in the left inguinal areas 5 days after underlying a procedure using the transfemoral arterial approach.

A, B. A gray-scale image with longitudinal (A) and transverse (B) ultrasonography shows a lobulated anechoic lesion (arrows) along the left common femoral artery. C. A color Doppler ultrasonography reveals a hematoma (arrows) without internal flow or communication with the artery.
usg-17047-f2.gif
Fig. 2.

Hematoma of a 58-year-old man with a palpable hard mass in the left inguinal region 1 month after undergoing a procedure using the transfemoral arterial approach.

A gray-scale ultrasonography shows an ill-defined isoechoic lesion that is similar to the surrounding tissue due to disruption of the echotexture of the muscle by an intramuscular hematoma of intermediate age.
usg-17047-f3.gif
Fig. 3.

Pseudoaneurysm of a 79-year-old man who complained a palpable mass and audible bruit in the right inguinal area.

He underwent stent insertion at the left anterior descending coronary artery 1 week before the ultrasound. A. A gray-scale ultrasonography shows a well-defined anechoic cystic mass in which echogenic material has been deposited. B. Color Doppler ultrasonography shows a bidirectional, turbulent, swirling blood-flow pattern known as the “yin-yang” sign within a pseudoaneurysm. Note the small amount of peripheral thrombi (arrows) within the pseudoaneurysm.
usg-17047-f4.gif
Fig. 4.

Pseudoaneurysm of a 55-year-old man with a pulsatile inguinal mass and audible bruit 1 day after undergoing percutaneous stent insertion in the left anterior descending artery.

A. Computed tomography scan shows a partially thrombosed pseudoaneurysm (arrows) measuring about 3×5 cm. B. Spectral Doppler ultrasonography shows the “to-and-fro” flow in the communicating neck between the arterial vessel and pseudoaneurysmal sac.
usg-17047-f5.gif
Fig. 5.

Ultrasound-guided thrombin injection.

Guided by ultrasonography, the needle was inserted at the far away from the neck which communicating native common femoral artery, and the thrombin was carefully injected into the pseudoaneurysmal sac. During the procedure, ultrasonographic examination is essential to avoid embolic events in the native common femoral artery.
usg-17047-f6.gif
Fig. 6.

Arteriovenous fistula of a 66-year-old woman with audible bruit at the right femoral puncture site 3 days after undergoing femoral catheterization for radiofrequency ablation to treat ventricular tachycardia.

A. Color Doppler ultrasonography shows direct communication (arrow) between the superficial femoral artery (A) and the common femoral vein (V), as well as a turbulent, high-velocity flow spectrum at the junction of the artery and the vein (arrowheads). B. Spectral Doppler ultrasonography reveals a high-velocity arterialized waveform in the draining vein.
usg-17047-f7.gif
Fig. 7.

Arteriovenous fistula of a 72-year-old woman with audible bruit in the right inguinal area 2 days after undergoing cerebral angiography.

A. A color Doppler ultrasonography of the sagittal shows perivascular bruit and aliasing within the dilated common femoral vein (arrows), which indicates a high-velocity flow from the communicating artery, although the connecting channel is not clearly noted. B. Spectral Doppler ultrasonography reveals a high-velocity arterialized waveform in the draining vein, which is a direct sign of an arteriovenous fistula.
usg-17047-f8.gif
Fig. 8.

Combined arteriovenous fistula and pseudoaneurysm of a 39-year-old man who underwent femoral puncture 2 times due to cerebral coil embolization of the right posterior cerebral artery and patent foramen ovale closure.

A-C. Serial computed tomography images show an arteriovenous fistula (arrowheads, A) between the superficial femoral artery (sA) and common femoral vein (V). Another lobulated pseudoaneurysm (arrows, B, C) is found arising from the sA. D is a deep femoral artery.
usg-17047-f9.gif
Fig. 9.

Femoral artery dissection of a 57-year-old woman who complained right leg numbness 2 days after femoral angiography.

A, B. Gray-scale longitudinal (A) and transverse (B) ultrasonography shows a linear echogenic flap separating the lumen of the femoral artery. C, D. Color Doppler longitudinal (C) and transverse (D) ultrasonography also shows the double lumen partially separated by the echogenic flap (arrows).
usg-17047-f10.gif
Fig. 10.

Arterial thrombus of a 68-year-old woman who complained numbness and coldness in her right lower leg 4 days after femoral angiography.

A. A gray-scale ultrasonography shows inhomogeneous echogenic material filling the femoral artery. B. A color Doppler ultrasonography shows the absence of color flow within the arterial lumen, indicating a thrombus.
usg-17047-f11.gif
Fig. 11.

Retroperitoneal hemorrhage of a 57-year-old man who complained pain in his right lower quadrant and lower back 2 days after coil embolization of the right vertebral artery for a dissecting aneurysm.

A-C. Serial computed tomography images show the large retroperitoneal hematoma due to bleeding from the external iliac artery (arrows). D. Gray-scale ultrasonography shows an inhomogeneous echogenic retroperitoneal hemorrhage (arrows).
usg-17047-f12.gif
Fig. 12.
TOOLS
METRICS
22
Web of Science
20
Crossref
26
Scopus
22,489
View
487
Download
We recommend
Editorial Office
A-304 Mapo Trapalace, 53 Mapo-daero, Mapo-gu, Seoul 04158, Korea
TEL : +82-2-763-5627   FAX : +82-2-763-6909   E-mail : office@ultrasound.or.kr
About |  Browse Articles |  Current Issue |  For Authors and Reviewers
Copyright © Korean Society of Ultrasound in Medicine.                 Developed in M2PI
Zoom in Close layer