Skip to main content
Advertisement
Browse Subject Areas
?

Click through the PLOS taxonomy to find articles in your field.

For more information about PLOS Subject Areas, click here.

  • Loading metrics

Preserving Posterior Complex Can Prevent Adjacent Segment Disease following Posterior Lumbar Interbody Fusion Surgeries: A Finite Element Analysis

  • Yun-Peng Huang,

    Affiliation Department of Orthopaedics, The First Affiliated Hospital of Fujian Medical University, Fuzhou City, Fujian Province, 350005, China

  • Cheng-Fei Du,

    Affiliations Tianjin Key Laboratory for Advanced Mechatronic System Design and Intelligent Control, Tianjin University of Technology, Tianjin, 300384, China, Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, International Research Center for Implantable and Interventional Medical Devices, School of Biological Science and Medical Engineering, Beihang University, Beijing, 100191, China

  • Cheng-Kung Cheng,

    Affiliations Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, International Research Center for Implantable and Interventional Medical Devices, School of Biological Science and Medical Engineering, Beihang University, Beijing, 100191, China, Orthopaedic Device Research Center, National Yang-Ming University, 11221, Taipei, China

  • Zheng-Cheng Zhong,

    Affiliation Orthopaedic Device Research Center, National Yang-Ming University, 11221, Taipei, China

  • Xuan-Wei Chen,

    Affiliation Department of Orthopaedics, The First Affiliated Hospital of Fujian Medical University, Fuzhou City, Fujian Province, 350005, China

  • Gui Wu,

    Affiliation Department of Orthopaedics, The First Affiliated Hospital of Fujian Medical University, Fuzhou City, Fujian Province, 350005, China

  • Zhe-Cheng Li,

    Affiliation Department of Orthopaedics, The First Affiliated Hospital of Fujian Medical University, Fuzhou City, Fujian Province, 350005, China

  • Jin-Duo Ye,

    Affiliation Tianjin Key Laboratory for Advanced Mechatronic System Design and Intelligent Control, Tianjin University of Technology, Tianjin, 300384, China

  • Jian-Hua Lin ,

    jianhua0918@126.com (JHL); lizhenwang@buaa.edu.cn (LZW)

    Affiliation Department of Orthopaedics, The First Affiliated Hospital of Fujian Medical University, Fuzhou City, Fujian Province, 350005, China

  • Li Zhen Wang

    jianhua0918@126.com (JHL); lizhenwang@buaa.edu.cn (LZW)

    Affiliation Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, International Research Center for Implantable and Interventional Medical Devices, School of Biological Science and Medical Engineering, Beihang University, Beijing, 100191, China

Correction

13 Feb 2017: Huang YP, Du CF, Cheng CK, Zhong ZC, Chen XW, et al. (2017) Correction: Preserving Posterior Complex Can Prevent Adjacent Segment Disease following Posterior Lumbar Interbody Fusion Surgeries: A Finite Element Analysis. PLOS ONE 12(2): e0172329. https://doi.org/10.1371/journal.pone.0172329 View correction

Abstract

Objective

To investigate the biomechanical effects of the lumbar posterior complex on the adjacent segments after posterior lumbar interbody fusion (PLIF) surgeries.

Methods

A finite element model of the L1–S1 segment was modified to simulate PLIF with total laminectomy (PLIF-LAM) and PLIF with hemilaminectomy (PLIF-HEMI) procedures. The models were subjected to a 400N follower load with a 7.5-N.m moment of flexion, extension, torsion, and lateral bending. The range of motion (ROM), intradiscal pressure (IDP), and ligament force were compared.

Results

In Flexion, the ROM, IDP and ligament force of posterior longitudinal ligament, intertransverse ligament, and capsular ligament remarkably increased at the proximal adjacent segment in the PLIF-LAM model, and slightly increased in the PLIF-HEMI model. There was almost no difference for the ROM, IDP and ligament force at L5-S1 level between the two PLIF models although the ligament forces of ligamenta flava remarkably increased compared with the intact lumbar spine (INT) model. For the other loading conditions, these two models almost showed no difference in ROM, IDP and ligament force on the adjacent discs.

Conclusions

Preserved posterior complex acts as the posterior tension band during PLIF surgery and results in less ROM, IDP and ligament forces on the proximal adjacent segment in flexion. Preserving the posterior complex during decompression can be effective on preventing adjacent segment degeneration (ASD) following PLIF surgeries.

Introduction

Posterior lumbar interbody fusion (PLIF) has become a widely accepted surgical procedure to achieve a solid and stable arthrodesis. Nevertheless, adjacent segment degeneration (ASD) has been reported to be a long-term complication after fusion [1, 2]. The occurrence of radiographic ASD (R-ASD) and symptomatic ASD (S-ASD) in lumbar position have been reported to reach 26.6% and 8.5% respectively in long-term follow-ups [1, 2]. It is evident that the number of surgical interventions for ASD will continue to increase as more spinal fusions are performed. Previous biomechanical and prospective clinical studies have demonstrated that important factors leading to adjacent segment motion, stress, and degenerative changes after fusionare construct stiffness, consequences of the fusion itself and consequences of surgical procedures such as radical decompression, which can often be modified at the time of the operation[3, 4].

During PLIF surgeries, it is essential to decompress the involved neural elements by removing all or part of the posterior elements, including the lamina, spinous process, supraspinous ligament (SSL) and interspinous ligament (ISL), ligamentum flavum (LF), and facet joints. In an intact lumbar spine, posterior complex (including spinous process, SSL and ISL) [4] plays a critical role of a tension band mechanism to resist a greater flexed moment [5, 6]. Theoretically, removing the posterior complex during PLIF procedures may influence motion and loadbearing characteristics of the adjacent segment, and thus contributing to the pathogenesis of postoperative instability at the adjacent segment [4, 6, 7].

In fact, several long-term follow-ups of posterolateral fusion with decompressive laminectomy revealed that accelerated degeneration of adjacent segment and segmental instability above the fusion occurred in all their patients [7, 8]. On the other hand, previous studies have reported less ASD after anterior fusion surgeries, which remained the intact posterior structures [9]. A previous study using a posterolateral finite element (FE) model with total laminectomy versus posterolateral fusion with hemilaminectomy, has shown that the SSL and ISL shared some external forces and consequently reduced the stress concentration in adjacent segments, and may contribute to delay ASD [10].

Clinically, previous studies have found that progressive postoperative ASD occurred significantly more frequently in patients conducted by PLIF with total laminectomy [4, 11]. Based on the above results, we hypothesized that preservation of the posterior complex in the decompression procedure has the biomechanical effect in preventing ASD following PLIF surgery. However, no biomechanical study has specifically addressed the effect of preserving posterior elements during PLIF surgeries on postoperative ASD.

In the present study, we developed a FE model to investigate the biomechanical changes resulting from the PLIF models using two comparable decompression techniques, that was, PLIF with LAM (PLIF-LAM) versus PLIF with HEMI (PLIF-HEMI) model, subsequently determined whether preserving the posterior complex had a preventive effect on ASD following PLIF.

Methods

A previously validated 3-dimensional intact lumbar (INT) FE model (L1–S1) was used [12]. The commercial finite element program package (Abaqus 6.11; Dassault Systèmes Simulia Corporation, France) was used to model the spinal segments. The FE model of the detailed ligamentous lumbar spine included vertebrae, intervertebral discs, facet joints, and the surrounding ligaments: i.e., anterior longitudinal ligament (ALL), posterior longitudinal ligament (PLL), intertransverse ligament (ITL), LF, ISL, SSL, and capsular ligament (CL). The disc annulus consisted of fibers embedded in the ground substance. The spinal vertebrae and intervertebral discs were modeled as 8-node, 3-dimensional solid elements. The annulus ground substance and nucleus pulposus were simulated to be nearly incompressible and hyper-elastic [12, 13]. The spinal ligaments and annulus fibers of discs were modeled as tension-only springs with nonlinear properties taken from the literature [13]. The contact characteristics of the facet articulation were simulated by three-dimensional frictionless contact elements. The gap of the facet joint was < 0.1 mm. The material properties of this FE model were listed in Table 1. To verify the reliability of the intact FE model, the range of motion (ROM) of this INT model was compared with the experimental and simulated data presented by Renner et al [14].

thumbnail
Table 1. Material properties used in finite element model of the lumbar spine.

https://doi.org/10.1371/journal.pone.0166452.t001

PLIF Model

In the procedure of the interbody fusion, the entire nucleus, part of the annulus at the posterior-right side were removed. The anterior aspect of the disc space was then firmly packed with cancellous bone graft, followed by asymmetrical placement of a single polyetheretherketone (PEEK) cage (10 × 10 × 22 mm × 4°; B.J.C. capstone; Medtronic Sofamor, Danek, Memphis, TN, USA), diagonally positioned at 45° in the middle and posterior disk space (Fig 1). All the cages were filled with cancellous bone to simulate the embedded bone graft within the implanted cage. The cage-bone interface was modeled by surface-to-surface contact elements to simulate the early postoperative stage after PLIF surgeries. The coefficient of friction at the cage-vertebra interface was 0.2 to mimic small teeth on the contact surfaces [15].

thumbnail
Fig 1. Cage and cross-sectional view of the posterior lumbar interbody fusion model.

(A) Lateral view of the polyetheretherketone (PEEK) cage, and (B) cross-sectional view of the posterior lumbar interbody fusion model with one diagonally placed PEEK cage.

https://doi.org/10.1371/journal.pone.0166452.g001

The posterior decompressive surgery as total laminectomy includes the resection of L4 posterior midline structures (lamina, spinous process, LF, SSL, ISL, as well as the medial half of the facet joints at the L4–L5 level), so the PLIF-LAM model was constructed (Fig 2A and 2B). The PLIF-HEMI model was also constructed by removing the right lamina, facet joint and LF while preserving the spinous process, contralateral lamina and facet joint, as well as the left LF, SSL and ISL (Fig 2C and 2D). Both PLIF models included spinal fixator made of titanium alloy by using 3-dimensional solid element, so the spinal fixator was through the pedicle and vertebral body. The spinal fixator included four pedicle screws 6.5 mm diameter each, and two rods 5.5 mm diameter.

thumbnail
Fig 2. Finite element models of posterior lumbar interbody fusion.

(A) Posterior and (B) lateral view of the posterior lumbar interbody fusion with total laminectomy (PLIF-LAM) model, and (C) posterior (D) and lateral view of the PLIF with hemilaminectomy (PLIF-HEMI) model.

https://doi.org/10.1371/journal.pone.0166452.g002

Boundary and Loading Conditions

The L1 vertebral body was subjected to a 400-N compressive follower preload [16, 17] while the inferior surface of the S1 vertebra was completely fixed in all degrees of freedom. Moreover, additional 7.5-N.m bending moments were applied to simulate flexion, extension, lateral bending and torsion [18, 19]. Finally, the ROM, the intradiscal pressure (IDP), and the ligament force were computed and compared among the simulated cases.

Results

Validation of the Intact FE Model

We compared our motion and compression displacement results with those from a previous in vitro study and a FE model conducted by Renner et al. [14] under the same loads to our model. A good agreement was obtained between our results and the previously reported data (Fig 3).

thumbnail
Fig 3. Comparison of Motion between the current intact model and the previous study of Renner et al.

https://doi.org/10.1371/journal.pone.0166452.g003

Range of motion

The ROM at the L4-L5 level of two models was less than that of the intact model in flexion, extension, bending and axial rotation respectively (Table 2). Differences in ROM at the L4–L5 level between two models were less than 0.3° for all loading cases. Both PLIF models had similar stabilization in extension, rotation, and bending cases.

thumbnail
Table 2. The ROM among three models in each loading condition.

https://doi.org/10.1371/journal.pone.0166452.t002

Compared with the INT model, the ROM of the PLIF-LAM and PLIF-HEMI models respectively increased by 24.7% and 4.3% at the L3–L4 level during flexion (Fig 4). For the other loading conditions, these two models had almost no difference in ROM on the adjacent discs.

thumbnail
Fig 4. The results of range of motion (ROM) in flexion.

(A) Range of motion (ROM) in flexion among the intact (INT) model and the two posterior lumbar interbody fusion (PLIF) models, and (B) percentage change in ROM between the two PLIF models during flexion. Percentage change = (Data of surgical model—Data of intact model)/Data of intact model ×100%.

https://doi.org/10.1371/journal.pone.0166452.g004

Intradiscal Pressure of the Adjacent Segments

The only difference in IDP was found during flexion at the L3–L4 level: the IDP increased by 8.7% in the PLIF-LAM model and 1.1% in the PLIF-HEMI model respectively as compared with that of the INT model, while differences in IDP for the other loading conditions were less than 1.2% (Fig 5). In contrast, the IDPs of the PLIF-HEMI model were similar to those of the INT model for all adjacent levels.

thumbnail
Fig 5. The results of intradiscal pressure (IDP) in flexion.

Percentage change of IDPs in flexion between the two PLIF models (A). Percentage change = (Data of surgical model - Data of intact model)/Data of intact model ×100%. Contour plots of IDP at (B) L3-L4 and (C) L5-S1 levels.

https://doi.org/10.1371/journal.pone.0166452.g005

Ligament Forces

Compared with the INT model, the forces of the preserved ligaments remarkably decreased at the fused segment in the two PLIF models, owing to a remarkable decrease in ROM at the fused level. These values were not different between these two models.

In flexion, the force of the PLL, ITL and CL at the L3-L4 level increased by 19.2%, 14.6% and 7.0% in the PLIF-HEMI model, and by 106.4%, 139.4% and 103.1% in the PLIF-LAM model respectively. In the PLIF-LAM model, the SSL, ISL and LF at the L3-L4 level had no tensile force for all loading conditions since the laminectomy surgery removed the anchoring point of the three ligaments. In the PLIF-HEMI model, the force of ISL and SSL respectively decreased by 6.0% and 7.2%. The force of the LF at the L3-L4 level decreased by 42.2% since the hemilamintectomy surgery removed the anchoring point of the LF on the right side (Fig 6A).

thumbnail
Fig 6. Results of the ligament forces at the L3-L4 and L5-S1 levels in flexion.

Percentage change in the ligament forces at the L3-L4 (A) and L5-S1 (B) levels in flexion. Percentage change = (Data of surgical model—Data of intact model)/Data of intact model ×100%.

https://doi.org/10.1371/journal.pone.0166452.g006

Compared with the INT model, the ligament force of the LF at the L5/S1 level respectively increased by 323.1% and 314.0% for the PLIF-LAM and PLIF-HEMI models (Fig 6B). For the other loading conditions, the ligament forces in the two PLIF models were similar to those in the model.

Discussion

Decompression is a routine procedure during PLIF surgery, involving the removal of all or part of the posterior elements. Posterior complex including spinous process, SSL and ISL is the main stabilizing elements as the lumbar spine is flexed within the physiological motions [3, 4]. From the biomechanical point of view, the removal of the posterior complex eliminates the tension band effect in the flexion motion and causes the accelerated development of ASD [7, 8, 20]. The present simulation study was to investigate the biomechanical effect of the posterior complex on adjacent segments by comparing total laminectomy PLIF and hemilaminectomy PLIF model techniques by using finite element analysis.

Our study indicated that the PLIF-LAM and PLIF-HEMI models were able to acquire similar stabilization through the construction of spinal fixators and bone graft, even if the lamina and posterior ligaments were removed. The FE model results showed that the increases in the ROM and IDP were found at the proximal adjacent segment of the PLIF-LAM model. These great changes in the ROM and IDP could be used to interpret the clinical findings of early degeneration of adjacent segment following PLIF surgeries [11, 21, 22].

The greatest increase in ROM and IDP occurred for the flexion loading condition at the L3–L4 level. Indeed, compared with the INT model, the ROM at the proximal adjacent level increased by 24.7% for the PLIF-LAM model and by 4.3% for the PLIF-HEMI model in flexion. This ROM increase was accompanied by an increase in IDP. The IDP of the PLIF-LAM model increased by 8.7% while only a slight increase (1.1%) was found in PLIF-HEMI model as compared with the INT model. Our results suggest that the patients who underwent posterior lumbar interbody fusion surgery with total laminectomy operation are likely to experience a higher incidence of ASD than those who underwent posterior lumbar interbody fusion with hemi-laminectomy operations, which were in accordance with the previous clinical studies [3, 11]. Biomechanically, the SSL and ISL act as a tension band in an intact spine, especially during flexion [23, 24]. In the PLIF-LAM model, the removal of the whole L4 spinous process would damage the SSL, ISL or the anchoring point of the neighboring unfused segments, jeopardize the effect of the tension band, and thus causing the accelerated development of ASD. In contrast, in the PLIF-HEMI model, the preserved posterior complex was able to share external forces and consequently alleviated the IDP in the adjacent discs. On the other hand, Sim et al. [16] found the similar biomechanical properties regarding ROM and IDP at the adjacent segments for the PLIF and transforaminal lumbar interbody fusion (TLIF) groups when using human L2-S2 cadaveric spine specimens, which was probably due to the fact that the posterior complex was kept intact in both groups. Besides, these values were not statistically increased from those of the intact spine [16]. Clinically, the preservation of the posterior complex also allows resuture the lumbar dorsal fascia to the SSL and ISL [4, 7, 10]. These structures provide important bony attachments for the posterior stabilizing paraspinal muscles acting as active spinal stabilizers. Our findings supported the clinical observations that preservation of the posterior complex in fused segment decompression should result in better protection against ASD [4, 11].

In flexion, the changes in distribution of ligament forces at the proximal adjacent segment level were different between the two PLIF models. The ligament forces of the PLL, ITL and CL remarkably increased at the proximal adjacent segment in the PLIF-LAM model with the removal of the posterior complex, whereas the forces of the PLL, ITL and FC slightly increased in the PLIF-HEMI model with the preserved posterior complex. Biomechanically, the preserved posterior complex in the PLIF-HEMI model was able to share external forces, which is the dominant component of the resistance to flexion in an intact spine [10]. Oppositely, the removal of the posterior complex eliminated the tension band effect in the flexion motion [4, 7], which may thus produce larger forces on the PLL, ITL and CL to resist to flexion loading. Several authors reported that the changes in load sharing among ligaments would alter the normal physiological and mechanical environments of ligaments, leading to ligament failure and hypertrophy [24, 25]. Moreover, the increase in ligaments forces were likely relevant to the invocation of pain and prone to cause chronic soft tissue injury, facet joint degeneration as well as hypertrophy of the LF, and thereby cause the ASD [5, 23, 24, 26].

On the other hand, there was almost no difference in ligament forces at the L5–S1 level between the two PLIF models. Interestingly, although the posterior complex was kept intact at the distal adjacent level in the two surgical models, there was a marked increase in ligament forces on LFs at the L5–S1 level comparing with the INT model. Our results also indicated that the loading of ligaments at the dorsal adjacent segment may be changed by the altered stress caused by the rigid instrumentations and fusion, regardless of the preservation or removal of the posterior complex between the fused and adjacent segments. Recently, non-fusion technologies such as posterior dynamic stabilization (PDS) devices can restore the stability of the lumbar spine without adverse stress-shielding effects [27]. Further study would investigate whether the introduction of PDS induces a substantial reduction in the ligament force rise at the dorsal adjacent level.

Compared with previous PLIF FE models [16, 17, 24], the current PLIF FE model focused on the important role of posterior complex. Biomechanically, posterior complex acts as the posterior tension band in flexion. A previous FE analysis has shown that removing the posterior complex during decompression with posterolateral fusion could cause potential adjacent segmental instability [10]. Moreover, PLIF has been reported to be more rigid than posterolateral fusion [28, 29], and hence patients who undergo are likely to experience a higher incidence of ASD than those who underwent posterolateral fusion [30]. However, most previous PLIF FE analyses have neglected the importance of posterior complex and focused on the altered biomechanical behavior in the fused lumbar spine with spinal fixators and cages [16, 17, 24, 28, 29]. Therefore, our FE model found that the preserved posterior complex led to less ROM, IDP and ligament forces on the proximal adjacent segment in flexion.

Our data were based upon FE analysis and hence had several limitations. Firstly, the material properties of simulation are slightly simplified and idealized. More accurate geometrical and material properties should be considered in future work. Secondly, only relative values of IDP and ligament force were used and compared since the two parameters were difficult to obtain from cadaveric experiments. Thirdly, the muscle contractions may bring complicated external forces that could have significant influences on the biomechanical perspective. Finally, we only performed L4–L5 level fusion in our biomechanical study. However, results may vary if the fusion is performed in other segments, or in two-level fusion. However, although some aspects were simplified in our FE model, it was well validated by the previous in vitro study. Therefore, the model established in this study is valid and can be used as an efficient tool to evaluate the effects of the two surgical scenarios on the lumbar spine.

Conclusion

The preserved posterior complex acts as the posterior tension band during PLIF surgery and results in less ROM, IDP and ligament forces on the proximal adjacent segment in flexion. Therefore, preserving the posterior complex during decompression can be effective in preventing ASD following PLIF surgeries.

Supporting Information

S1 Fig. Cage and cross-sectional view of the posterior lumbar interbody fusion model.

(A) Lateral view of the polyetheretherketone (PEEK) cage, and (B) cross-sectional view of the posterior lumbar interbody fusion model with one diagonally placed PEEK cage.

https://doi.org/10.1371/journal.pone.0166452.s001

(TIF)

S2 Fig. Finite element models of posterior lumbar interbody fusion.

(A) Posterior and (B) lateral view of the posterior lumbar interbody fusion with total laminectomy (PLIF-LAM) model, and (C) posterior (D) and lateral view of the PLIF with hemilaminectomy (PLIF-HEMI) model.

https://doi.org/10.1371/journal.pone.0166452.s002

(TIF)

S3 Fig. Comparison of Motion between the current intact model and the previous study of Renner et al.

https://doi.org/10.1371/journal.pone.0166452.s003

(TIF)

S4 Fig. The results of range of motion (ROM) in flexion.

(A) Range of motion (ROM) in flexion among the intact (INT) model and the two posterior lumbar interbody fusion (PLIF) models, and (B) percentage change in ROM between the two PLIF models during flexion. Percentage change = (Data of surgical model—Data of intact model)/Data of intact model ×100%.

https://doi.org/10.1371/journal.pone.0166452.s004

(TIF)

S5 Fig. The results of intradiscal pressure (IDP) in flexion.

Percentage change of IDPs in flexion between the two PLIF models. Percentage change = (Data of surgical model—Data of intact model)/Data of intact model ×100%. Contour plots of IDP at (C) L3-L4 and (D) L5-S1 levels.

https://doi.org/10.1371/journal.pone.0166452.s005

(TIF)

S6 Fig. Results of the ligament forces at the L3-L4 and L5-S1 levels in flexion.

Percentage change in the ligament forces at the L3-L4 (A) and L5-S1 (B) levels in flexion. Percentage change = (Data of surgical model—Data of intact model)/Data of intact model ×100%.

https://doi.org/10.1371/journal.pone.0166452.s006

(TIF)

S1 Table. Material properties used in finite element model of the lumbar spine.

INT model: intact lumbar spine; PLIF, posterior lumbar interbody fusion; PLIF-HEMI, posterior lumbar interbody fusion with hemi-laminectomy model; PLIF-LAM, posterior lumbar interbody fusion with total laminectomy model.

https://doi.org/10.1371/journal.pone.0166452.s007

(PDF)

S2 Table. The ROM among three models in each loading condition.

INT model: intact lumbar spine; PLIF-HEMI, posterior lumbar interbody fusion with hemilaminectomy model; PLIF-LAM, posterior lumbar interbody fusion with total laminectomy model.

https://doi.org/10.1371/journal.pone.0166452.s008

(PDF)

Acknowledgments

The study was supported by a grant from the Department of Public Health Bureau, Fujian, P.R.C (No. 2013-ZQN-ZD-19); and by a grant from the key Clinical Specialty Discipline Construction Program of Fujian, P.R.C. The study was also supported by the program from the National Natural Science Foundation of China (NSFC No. 11372221, No. 11432016 and No. 11602172).

Author Contributions

  1. Conceptualization: YPH CKC JHL.
  2. Data curation: YPH CFD ZCZ.
  3. Formal analysis: YPH.
  4. Investigation: XWC GW ZCL.
  5. Methodology: CKC.
  6. Project administration: JHL LZW.
  7. Resources: CFD XWC JDY.
  8. Software: CFD.
  9. Supervision: CKC JHL LZW.
  10. Validation: CFD.
  11. Visualization: CFD XWC JDY GW.
  12. Writing – original draft: YPH ZCZ CFD ZCL.
  13. Writing – review & editing: CKC JHL LZW.

References

  1. 1. Xia XP, Chen HL, Cheng HB. Prevalence of adjacent segment degeneration after spine surgery: a systematic review and meta-analysis. Spine (Phila Pa 1976). 2013;38(7):597–608. Epub 2012/09/19.
  2. 2. Levin DA, Hale JJ, Bendo JA. Adjacent segment degeneration following spinal fusion for degenerative disc disease. Bull NYU Hosp Jt Dis. 2007;65(1):29–36. Epub 2007/06/02. pmid:17539759
  3. 3. Lawrence BD, Wang J, Arnold PM, Hermsmeyer J, Norvell DC, Brodke DS. Predicting the risk of adjacent segment pathology after lumbar fusion: a systematic review. Spine (Phila Pa 1976). 2012;37(22 Suppl):S123–32. Epub 2012/08/14.
  4. 4. Liu H, Wu W, Li Y, Liu J, Yang K, Chen Y. Protective effects of preserving the posterior complex on the development of adjacent-segment degeneration after lumbar fusion. J Neurosurg Spine. 2013;19(2):201–6. Epub 2013/06/19. pmid:23768024
  5. 5. Goel VK, Kim YE, Lim TH, Weinstein JN. An analytical investigation of the mechanics of spinal instrumentation. Spine (Phila Pa 1976). 1988;13(9):1003–11. Epub 1988/09/01.
  6. 6. Moskowitz A. Transforaminal lumbar interbody fusion. Orthop Clin North Am. 2002;33(2):359–66. Epub 2002/10/23. pmid:12389281
  7. 7. Lai PL, Chen LH, Niu CC, Fu TS, Chen WJ. Relation between laminectomy and development of adjacent segment instability after lumbar fusion with pedicle fixation. Spine (Phila Pa 1976). 2004;29(22):2527–32; discussion 32.
  8. 8. Ekman P, Moller H, Shalabi A, Yu YX, Hedlund R. A prospective randomised study on the long-term effect of lumbar fusion on adjacent disc degeneration. Eur Spine J. 2009;18(8):1175–86. pmid:19337757
  9. 9. Wai EK, Santos ER, Morcom RA, Fraser RD. Magnetic resonance imaging 20 years after anterior lumbar interbody fusion. Spine (Phila Pa 1976). 2006;31(17):1952–6.
  10. 10. Chen CS, Feng CK, Cheng CK, Tzeng MJ, Liu CL, Chen WJ. Biomechanical analysis of the disc adjacent to posterolateral fusion with laminectomy in lumbar spine. J Spinal Disord Tech. 2005;18(1):58–65. Epub 2005/02/03. pmid:15687854
  11. 11. Imagama S, Kawakami N, Kanemura T, Matsubara Y, Tsuji T, Ohara T, et al. Radiographic Adjacent Segment Degeneration at Five Years After L4/5 Posterior Lumbar Interbody Fusion With Pedicle Screw Instrumentation: Evaluation by Computed Tomography and Annual Screening With Magnetic Resonance Imaging. Clinical spine surgery. 2016. Epub 2016/05/04.
  12. 12. Du C, Mo Z, Tian S, Wang L, Fan J, Liu S, et al. Biomechanical investigation of thoracolumbar spine in different postures during ejection using a combined finite element and multi-body approach. International journal for numerical methods in biomedical engineering. 2014;30(11):1121–31. Epub 2014/05/16. pmid:24827805
  13. 13. Shirazi-Adl A, Ahmed AM, Shrivastava SC. Mechanical response of a lumbar motion segment in axial torque alone and combined with compression. Spine (Phila Pa 1976). 1986;11(9):914–27.
  14. 14. Renner SM, Natarajan RN, Patwardhan AG, Havey RM, Voronov LI, Guo BY, et al. Novel model to analyze the effect of a large compressive follower pre-load on range of motions in a lumbar spine. J Biomech. 2007;40(6):1326–32. Epub 2006/07/18. pmid:16843473
  15. 15. Vadapalli S, Sairyo K, Goel VK, Robon M, Biyani A, Khandha A, et al. Biomechanical rationale for using polyetheretherketone (PEEK) spacers for lumbar interbody fusion-A finite element study. Spine (Phila Pa 1976). 2006;31(26):E992–8. Epub 2006/12/19.
  16. 16. Sim HB, Murovic JA, Cho BY, Lim TJ, Park J. Biomechanical comparison of single-level posterior versus transforaminal lumbar interbody fusions with bilateral pedicle screw fixation: segmental stability and the effects on adjacent motion segments. J Neurosurg Spine. 2010;12(6):700–8. Epub 2010/06/03. pmid:20515358
  17. 17. Xu H, Ju W, Xu N, Zhang X, Zhu X, Zhu L, et al. Biomechanical Comparison of Transforaminal Lumbar Interbody Fusion With One or Two Cages by Finite Element Analysis. Neurosurgery. 2013. Epub 2013/05/02.
  18. 18. Schmidt H, Heuer F, Drumm J, Klezl Z, Claes L, Wilke HJ. Application of a calibration method provides more realistic results for a finite element model of a lumbar spinal segment. Clin Biomech (Bristol, Avon). 2007;22(4):377–84.
  19. 19. Yamamoto I, Panjabi MM, Crisco T, Oxland T. Three-dimensional movements of the whole lumbar spine and lumbosacral joint. Spine (Phila Pa 1976). 1989;14(11):1256–60.
  20. 20. Sears WR, Sergides IG, Kazemi N, Smith M, White GJ, Osburg B. Incidence and prevalence of surgery at segments adjacent to a previous posterior lumbar arthrodesis. Spine J. 2011;11(1):11–20. pmid:21168094
  21. 21. Nakashima H, Kawakami N, Tsuji T, Ohara T, Suzuki Y, Saito T, et al. Adjacent Segment Disease After Posterior Lumbar Interbody Fusion: Based on Cases With a Minimum of 10 Years of Follow-up. Spine (Phila Pa 1976). 2015;40(14):E831–41.
  22. 22. Panjabi MM. Clinical spinal instability and low back pain. J Electromyogr Kinesiol. 2003;13(4):371–9. pmid:12832167
  23. 23. Abouhossein A, Weisse B, Ferguson SJ. A multibody modelling approach to determine load sharing between passive elements of the lumbar spine. Comput Methods Biomech Biomed Engin. 2011;14(6):527–37. Epub 2010/12/04. pmid:21128134
  24. 24. Xiao Z, Wang L, Gong H, Zhu D. Biomechanical evaluation of three surgical scenarios of posterior lumbar interbody fusion by finite element analysis. Biomed Eng Online. 2012;11:31. Epub 2012/06/20. pmid:22709659
  25. 25. Kotani Y, Cunningham BW, Cappuccino A, Kaneda K, McAfee PC. The effects of spinal fixation and destabilization on the biomechanical and histologic properties of spinal ligaments. An in vivo study. Spine (Phila Pa 1976). 1998;23(6):672–82; discussion 82–3. Epub 1998/04/29.
  26. 26. Ma J, Jia H, Ma X, Xu W, Yu J, Feng R, et al. Evaluation of the stress distribution change at the adjacent facet joints after lumbar fusion surgery: a biomechanical study. Proceedings of the Institution of Mechanical Engineers Part H, Journal of engineering in medicine. 2014;228(7):665–73. pmid:24963037
  27. 27. Ahn YH, Chen WM, Lee KY, Park KW, Lee SJ. Comparison of the load-sharing characteristics between pedicle-based dynamic and rigid rod devices. Biomed Mater. 2008;3(4):044101. pmid:19029615
  28. 28. Goto K, Tajima N, Chosa E, Totoribe K, Kubo S, Kuroki H, et al. Effects of lumbar spinal fusion on the other lumbar intervertebral levels (three-dimensional finite element analysis). J Orthop Sci. 2003;8(4):577–84. pmid:12898313
  29. 29. Totoribe K, Tajima N, Chosa E. A biomechanical study of posterolateral lumbar fusion using a three-dimensional nonlinear finite element method. J Orthop Sci. 1999;4(2):115–26. pmid:10199989
  30. 30. Lee JC, Kim Y, Soh JW, Shin BJ. Risk factors of adjacent segment disease requiring surgery after lumbar spinal fusion: comparison of posterior lumbar interbody fusion and posterolateral fusion. Spine (Phila Pa 1976). 2014;39(5):E339–45.