Three-year clinical and radiological results of a cruciate-retaining type of the knee prosthesis with anatomical geometry developed in Japan

Abstract

Background

The FINE total knee was developed in Japan and clinical use began in 2001. It has unique design features, including an oblique 3o femorotibial joint line that reproduces anatomical geometry. Although 20 years have passed since the FINE knee was clinically used for the first time in Japan, a formal clinical evaluation including patient-reported and radiographic outcomes has not been undertaken.

Methods

A total of 175 consecutive primary cruciate-retaining (CR)-FINE total knee arthroplasties (TKAs) at our hospital between February 2015 and March 2017 were included in this study. Three years postoperatively, range of motion (ROM), Knee Society Score (KSS), Knee Injury and Osteoarthritis Outcome Score (KOOS) and Forgotten Joint Score (FJS) were recorded and compared with preoperative scores. Radiographic analyses including mechanical alignment, component alignment, and incidence of radiolucent lines also were undertaken based on the radiographs 3 years postoperatively.

Results

One-hundred twenty-two knees (70%) were available for 3-year follow-up data using KOOS, except for the sports subscale. Postoperative KOOS-symptom, −pain and -ADL were > 85 points, but KOOS-sports, −QOL and FJS were less satisfactory. ROM, KSS and all the subscales of KOOS were significantly improved compared with preoperative scores. Postoperative mean FJS was 66 and was significantly correlated with all the subscales of KOOS, but not with postoperative ROM. Radiolucent lines 1 mm wide were detected in five knees (4.1%). There were no major complications needing revision surgeries.

Conclusions

Patient-reported outcomes (PROs) for symptoms, pain and ADL after the CR-FINE TKA were generally improved, but those for sports, QOL and FJS were improved less. The incidence of radiolucent lines was rare but detected around the femoral components. With the mid- to long-term follow-up, improvements of surgical technique will be necessary to achieve better PROs from patients receiving the FINE knee.

Peer Review reports

Background

Although the outcomes of total knee arthroplasty (TKA) are generally acceptable, approximately 20% of patients have some complaints after TKA [1,2,3]. The reasons for dissatisfaction after TKA remain poorly understood; however, failure of restoration of a physiological joint line has been suggested as a causative factor. In 2011, Bellemans introduced kinematically aligned (KA)-TKA as a surgical technique to realize a physiological joint line [4]. The goal of KA-TKA is to maintain the orientation of the native joint line. While there have been studies showing that KA-TKA provides equivalent or better function and similar survival rate to mechanically aligned (MA)-TKA [5,6,7,8,9,10], the longevity of polyethylene inserts and femoral and/or tibial components implanted not perpendicular to the mechanical axis are a concern [11,12,13]. However, as a concise follow-up at 20 years of modern TKA with cement reported that neutral mechanical alignment did not provide better implant survivorship than the outlier group [14], it remains unknown whether KA-TKA provides better clinical outcomes and survivorship than MA-TKA.

The FINE total knee has been developed in Japan and used for approximately 20,000 TKAs of Japanese patients since 2001. It has unique design features, including an oblique 3o femorotibial joint line (Fig. 1). This feature allows to reproduce anatomical geometry by cutting the bone perpendicular to the mechanical axis. The sagittal curvature of the femoral component has dual-radii in extension and flexion range. The polyethylene insert also has a unique design; the medial surface has a convex curve with increased conformity to the femoral component while the lateral has a flat surface. These features of the FINE knee allow KA-TKA via conventional osteotomy, and enhance internal rotation of the tibia and femoral rollback via medial pivot motion [15], which would expect better patient-reported outcomes.

Fig. 1
figure 1

The FINE total knee. The femoral condyle has an asymmetric shape and femorotibial joint line with an oblique 3o both in coronal (left) and axial (right) planes which is incorporated into the implant design. The medial surface of the polyethylene insert has a convex curve while the lateral surface possesses a flat surface. FINE reproduces anatomical geometry by conducting osteotomy perpendicular to the mechanical axis. The figure is reprinted with minor modifications from Fig. 1 in the reference no. [15]

Although 20 years have passed since this implant was clinically used for the first time in Japan, a formal clinical evaluation including patient-reported and radiographic outcomes has not been undertaken. The aim of the present study was to evaluate the 3-year clinical results including patient-reported and radiographic outcomes in Japanese patients receiving a cruciate-retaining (CR) type of the FINE total knee.

Methods

Patients

A total of 175 consecutive primary TKAs using a CR type of the FINE total knee (Teijin-Nakashima Medical Co. Ltd., Okayama, Japan) in 157 patients at our hospital between February 2015 and March 2017 were included in this study. One patient (one TKA) died from TKA-unrelated causes. None received a revision. Of the remaining 174 TKAs (156 patients), 122 knees (111 patients, 70%) were available for 3-year follow-up data; the data for the Knee Injury and Osteoarthritis Outcome Score (KOOS) [16] except for a sports subscale and radiographs were available for all of those while data for KOOS-sports and the Forgotten Joint Score (FJS) [17] were available for 53 (30%) and 77 knees (44%), respectively (Fig. 2). There were nine men and 102 women, with a mean age of 72.3 years (29–89) at the time of surgery. The mean body mass index was 27.2 kg/m2 (16.7–39.6). One hundred twelve TKAs were performed for osteoarthritis, seven for rheumatoid arthritis (RA), and three for osteonecrosis (Table 1).

Fig. 2
figure 2

A flowchart of the patients during this study. TKA, total knee arthroplasty; KOOS, Knee Injury and Osteoarthritis Outcome Scores; FJS, Forgotten Joint Score

Table 1 Summary of demographic data for patients included in this study

This study was approved by the institutional review board at our institution (approved number: S17017). All activities were performed in accordance with the ethical standards set forth in the Declaration of Helsinki, and informed consent was obtained from all patients who participated in this study.

Surgical procedures

All TKAs were performed using the measured resection technique by anterior reference [18]. Surgical approaches were chosen either mid-vastus or sub-vastus for varus knees, but the lateral parapatellar approach was used for valgus knees. A release of the deep fibers of the medial collateral ligament (MCL) was routinely performed for varus knees. Surgeries were performed using conventional instruments; that is, distal femoral osteotomy was conducted perpendicular to the mechanical axis at a level 9–10 mm from the farthest point of the medial condyle, and the posterior condyle was osteotomized parallel to the surgical epicondylar axis (3°external to the posterior condylar line). A tibial osteotomy subsequently was conducted perpendicular to the anatomical axis of the tibia. The cutting level was set 8–10 mm distal to the convex of the lateral plateau. Following osteotomy, adjustments for soft tissue balancing were performed before the implants were fixed to the bone with cement. Whether to replace the patellar component or not depended on the surgeons’ decision; 80 knees received patellar replacement (66%, Table 1). Patients were discharged 3 weeks after surgery when they were medically stable, with pain controlled by oral analgesics and deemed by a physiotherapist to be mobilizing sufficiently to function safely at home.

Radiographic examinations

Routine postoperative assessment included anteroposterior, lateral, and 60°skyline radiographs of the knee, and full-length standing radiographs of both lower limbs. The anatomical axis (the angle subtended by lines bisecting the medullary canals of the femur and the tibia) and the mechanical axis (the angle subtended by lines connecting the center of the femoral head and the center of the femoral condyles, and the center of the tibial plateau to the center of the talus) were measured from full-length standing radiographs. The alignment of the components was assessed on AP radiographs of the knee using the distal femoral valgus angle (DFVA, α) and proximal tibial varus angle (PTVA, β), while the femoral flexion angle (FFA, γ) and tibial slope (TS, σ) were measured on lateral radiographs. The mechanical alignment was assessed by the hip-knee-ankle (HKA) angle based on the full-length standing radiographs with varus alignment designated as positive (Fig. 3). These measurements were performed using the protocol of Kilincoglu et al. [19]. Three independent observers (AN, MY, KY) examined radiographs for evidence of anterior notching of the femur, component failure or subsidence, lucent lines, osteolysis, and heterotopic ossification based on the standardized Knee Society radiological evaluation system [20].

Fig. 3
figure 3

Representative (a) anteroposterior radiograph of a CR-FINE TKA showing measurement of the distal femoral valgus angle (DFVA; α) and proximal tibia varus angle (PTVA, β). b Lateral radiograph showing measurement of the femoral flexion angle (FFA; γ) and tibial slope (TS; σ). c Full-length standing radiograph showing measurement of the hip-knee-ankle (HKA) angle. Varus mechanical alignment is designated as positive for HKA angle

Clinical evaluation

We used the Knee Society Score (KSS), which consists of a knee score (KSS-KS) and a function score (KSS-FS), as an objective evaluation of knee function [21]. In addition to the KSS, we used the Japanese KOOS, an instrument of confirmed validity and reliability for patient-reported outcomes (PROs) based on its cross-cultural adaptation [22]. The KOOS consists of a total of 42 knee-related items, and each item was scored from 0 to 4. Five KOOS subscales, including symptoms (KOOS-symptom), pain (KOOS-pain), ADL (KOOS-ADL), sports/recreation (KOOS-sports), and quality of life (KOOS-QOL) were converted to 100 points [16]. Furthermore, we investigated the FJS for 77 TKAs (72 patients). The range of motion (ROM) was measured using a goniometer. Postoperative scores were compared with the preoperative scores. Both intraoperative and postoperative complications were noted from the medical records.

Statistical analysis

The reliability of each radiographic measurement was assessed using intraclass correlation coefficients. All radiographic measurements in this study showed good reliability (all values > 0.8), and discrepancies were discussed until consensus was achieved. The paired t-test was used to compare 3-year postoperative with preoperative scores. Results were expressed as the mean (standard deviation, SD). Correlations among postoperative KSS, KOOS and FJS were analyzed by Pearson’s correlation coefficients. Data analyses were performed using SPSS software, version 21 (SPSS Inc., Chicago, IL, USA) and p-values of < 0.05 were considered statistically significant.

Results

Clinical outcome scores

Mean postoperative KSS-KS, KSS-FS, KOOS subscales, and FJS were shown in Tables 2 and 3. Patients reported clinically and statistically significant improvements in the KSS-KS, KSS-FS, and all subscales of the KOOS (p < 0.001).

Table 2 Summary of ROM and KSS
Table 3 Summary of patient-reported outcomes (PROs)

The postoperative flexion angle increased significantly compared with the preoperative one (p = 0.003, Table 2). Seven knees had limited extension; six knees had an extension limitation between 10°and 20°and one knee had a limitation of 25°.

Correlations among postoperative KSS, KOOS and FJS

Correlations among postoperative KSS, KOOS and FJS were computed to investigate the relationships among these postoperative outcomes. FJS was correlated significantly with KSS-FS and all the subscales of KOOS, but not with postoperative flexion angle or ROM (Table 4).

Table 4 Correlations among postoperative KSS, KOOS and FJS

Radiographic outcomes

Mean postoperative standing FTA, DFVA (α), PTVA (β), FFA (γ) and TS (σ) are shown in Table 5. Mean postoperative HKA angle (SD) was 2.3 (3.6)° with slightly varus alignment, and 74 knees (60.7%) were within ±3° of the HKA angle.

Table 5 Radiographic analysis for CR-FINE TKA 3 years postoperatively

Radiographic analyses 3 years postoperatively revealed no instances of osteolysis or subsidence. Radiolucent lines 1 mm wide were detected in five knees (4.1%), all of which occurred in zone 4 of the femoral components [20] but were insignificant clinically. There was one knee with heterotopic ossification in the quadriceps (0.8%), but it was asymptomatic (Table 5).

Complications

One patient died due to a cause unrelated to TKA. One had a suspicious deep infection but joint fluid culture was negative for bacteria and the knee was not revised. There were eight partial tears of the popliteal tendon intraoperatively, all of which were sutured using nylon thread. One patient had an intraoperative avulsion of the superficial fibers of the MCL from its insertion to the tibia, which was reconstructed by suture and pull-out. One patient with RA had a medial subchondral fracture of the proximal tibia intraoperatively, which was fixed using a cancellous screw. There was one lateral supracondylar fracture intraoperatively in an RA patient and one anterior femoral notching without a periprosthetic fracture, but no additional surgeries were required. One patient with a severely deformed valgus knee (preoperative femorotibial angle: 152°) had transient peroneal nerve palsy postoperatively but had recovered fully by the 3-year follow-up (Table 6).

Table 6 Summary of intra- and post-operative complications in 3 years after CR-FINE TKA

Discussion

The most characteristic point of the FINE knee is the design that reproduces the anatomical geometry, that is, a 3°obliquity built into the medial femorotibial surface in both coronal and axial planes. Here we showed that the postoperative mean DFVA was 98o, slightly more than that of the conventional prostheses. These features allow surgeons to perform KA-TKA by cutting the bone perpendicular to the mechanical axis. Furthermore, the FINE knee adopts an ultra-high molecular weight polyethylene insert including vitamin E with antioxidant properties. As there is an increased risk of revision in KA-TKA using conventional prostheses [23, 24], these characteristic designs of the FINE knee are expected to show superior longevity to the conventional prostheses implanted in kinematic alignment.

The second characteristic point of the FINE knee is the polyethylene insert, which is dish-shaped medially and has a flat-surface laterally. This structure allows natural internal rotation of the tibia and roll-back of the lateral femoral condyle during flexion, leading to deep flexion. Here, the mean postoperative flexion angle (SD) was 124 (13)° (Table 2). The correlation analyses among postoperative flexion angle, KSS, KOOS and FJS showed significant correlations between flexion angle and KSS-KS, while flexion angle did not show any significant correlations with KOOS subscales or FJS (Table 4). These results suggest that postoperative flexion angle has a significant impact on a physician-based objective evaluation but not on PROs.

For all patients included in this study, we performed TKAs using a measured resection (MR) technique. Van Lieshout et al. showed that the joint line was elevated after TKA using the MR technique [25]. In addition, Luyckx et al., using cadaver knees, demonstrated that despite a well-balanced knee in full extension and at 90°of flexion, increased mid-flexion instability was evident in knees in which the joint line was raised [26]. Because we cut femoral posterior condyles by anterior reference and used a CR-type for the patients who participated in this study, we might have implanted femoral components that were smaller than the anatomical anteroposterior length of the femoral condyles, and this may have caused shortening of the posterior condylar offsets. This may also raise the joint line, which in turn, causes mid-flexion instability.

Recently, the FJS has been used to evaluate top-performing TKAs since it has a diminished ceiling effect [17]. Parratte et al. described a cohort of posterior-stabilized Zimmer LPS-Flex TKA (Zimmer Biomet, Warsaw, Indiana) with a mean FJS of 74 at a mean follow-up of 3.8 years [27], while Thomsen et al. reported mean FJS for the Vanguard CR TKA (Zimmer Biomet) of between 44 and 59 from 1 to 4 years following mobile-bearing or CR TKAs [28]. Moreover, excellent 5-year clinical results of the medial ball and socket TKAs were demonstrated by Katchky et al. [29]. According to their report, the mean postoperative flexion angle was 124°. It was surprising that postoperative KOOS-symptom, −pain and -ADL were > 90, with KOOS-sports being 71 and KOOS-QOL being 82. Furthermore, postoperative Oxford Knee Score and FJS were 44 (full score: 48) and 75, respectively. These results are better than the results obtained from patients receiving a CR-type of the FINE knee. Although a simple comparison between the two different prostheses should be avoided as the backgrounds of the patients were different, these excellent mid-term results of the medial ball and socket knee suggest the importance of the congruent medial articulation.

To obtain better PROs from the FINE knee, we are now performing TKAs using the pre-cut technique developed by Kaneyama et al. [30], which creates the extension gap first and then a small temporary gap in flexion before the final cut of the femoral posterior condyles and allows to measure the flexion gap easily with the PCL intact. Using this technique, surgeons can determine the amount of additional cutting of the femoral posterior condyles to the extension gap to be adjusted. Adjustment of the flexion gap to the extension gap is expected to avoid shortening of the posterior condylar offset, leading to better ROM and stability in flexion after TKA [31,32,33]. Although we could not show better PROs for the CR-FINE knee than other top-performing prostheses developed in the US or Western Europe, adjustment of the flexion gap to the extension gap using the pre-cut technique will raise the PROs after the CR-FINE TKA. This is required to be addressed by the future clinical studies.

Radiographic analyses for the CR-FINE TKA 3 years postoperatively demonstrated radiolucent lines more than 1 mm wide in five knees (4.1%) (Table 6). All radiolucent lines were detected in zone 4 on the femoral component side. The possible reason for the radiolucent line in this location may be the application of less or no bone cement in that zone to avoid spill-over after implantation of the femoral components. Although no clinical problems occurred over 3 years postoperatively, continuous attention should be paid to whether these radiolucent lines will spread or not. It should be noted that no subsidence of the tibial components occurred during the 3-year follow-up period. Tibial base plates of the FINE knee adopt an asymmetric design between medial and lateral sides, which provides good coverage on the cut surface of the tibia. These features probably contribute to the absence of subsidence of the tibial components.

There are some limitations to this study. First, the sample size was relatively small and the patients were recruited from a single institution. Second, 30% of the knees were not available for analysis of 3-year KOOS data. Moreover, only 30% of knees were available for a KOOS-sports subscale, and 44% were available for FJS. Nevertheless, our results show that the FINE knee is widely acceptable for Japanese patients with knee deformities, considering the good PROs comparable to other top-performing knee prostheses.

Conclusions

We showed 3-year clinical results of a CR-type of the FINE total knee that was mechanically aligned through the MR technique. Postoperative KOOS-symptom, −pain and -ADL were > 85 points, but KOOS-sports, −QOL and FJS were less satisfactory. There were no major complications needing revision surgeries. Incidence of radiolucent lines was rare around the femoral components. There were no instances of osteolysis or subsidence. With the mid- to long-term follow-up, improvements of surgical technique will be necessary to achieve better PROs from patients receiving the FINE knee.

Availability of data and materials

All data generated or analyzed during the current study are included in this published article.

Abbreviations

CR:

Cruciate-retaining

TKA:

Total knee arthroplasty

KSS:

Knee Society Score

KOOS:

Knee injury Osteoarthritis Outcome Score

PROs:

Patient-reported outcomes

FJS:

Forgotten Joint Score

KA:

Kinematic alignment

ROM:

Range of motion

FTA:

Femorotibial angle

HKA:

Hip-knee-ankle

DFVA:

Distal femoral valgus angle

PTVA:

Proximal tibial varus angle

FFA:

Femoral flexion angle

TS:

Tibial slope

References

  1. Baker PN, van der Meulen JH, Lewsey J, Gregg PJ. National Joint Registry for England and Wales. The role of pain and function in determining patient satisfaction after total knee replacement. Data from the National Joint Registry for England and Wales. J Bone Joint Surg (Br). 2007;89-B:893–900.

    Article  Google Scholar 

  2. Clement ND, Macdonald D, Burnett R. Predicting patient satisfaction using the Oxford knee score: where do we draw the line? Arch Orthop Trauma Surg. 2013;133:689–94.

    Article  Google Scholar 

  3. Minns RJ. The role of gait analysis in the management of the knee. Knee. 2005;12:157–62.

    Article  CAS  Google Scholar 

  4. Bellemans J. Neutral mechanical alignment: a requirement for successful TKA: opposes. Orthopedics. 2011;34:e507–9.

    Article  Google Scholar 

  5. Woon JTK, Zeng ISL, Calliess T, Windhagen H, Ettinger M, Waterson HB, Toms AD, Young SW. Outcome of kinematic alignment using patient-specific instrumentation versus mechanical alignment in TKA: a meta-analysis and subgroup analysis of randomised trials. Arch Orthop Trauma Surg. 2018;138:1293–303.

    Article  CAS  Google Scholar 

  6. Young SW, Walker ML, Bayan A, Briant-Evans T, Pavlou P, Farrington B. The Chitranjan S. Ranawat award : no difference in 2-year functional outcomes using kinematic versus mechanical alignment in TKA: a randomized controlled clinical trial. Clin Orthop Relat Res. 2017;475:9–20.

    Article  Google Scholar 

  7. Laende EK, Richardson CG, Dunbar MJ. A randomized controlled trial of tibial component migration with kinematic alignment using patient-specific instrumentation versus mechanical alignment using computer-assisted surgery in total knee arthroplasty. Bone Joint J. 2019;101-B:929–40.

    Article  CAS  Google Scholar 

  8. Lee YS, Howell SM, Won YY, Lee OS, Lee SH, Vahedi H, Teo SH. Kinematic alignment is a possible alternative to mechanical alignment in total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc. 2017;25:3467–79.

    Article  Google Scholar 

  9. Howell SM, Shelton TJ, Hull ML. Implant survival and function ten years after kinematically aligned total knee arthroplasty. J Arthroplast. 2018;33:3678–84.

    Article  Google Scholar 

  10. Luo Z, Zhou K, Peng L, Shang Q, Pei F, Zhou Z. Similar results with kinematic and mechanical alignment applied in total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc. 2020;28:1720–35.

    Article  Google Scholar 

  11. Teeter MG, Naudie DD, McCalden RW, Yuan X, Holdsworth DW, MacDonald SJ, Lanting BA. Varus tibial alignment is associated with greater tibial baseplate migration at 10 years following total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc. 2018;26:1610–7.

    Article  Google Scholar 

  12. Howell SM, Hodapp EE, Vernace JV, Hull ML, Meade TD. Are undesirable contact kinematics minimized after kinematically aligned total knee arthroplasty? An intersurgeon analysis of consecutive patients. Knee Surg Sports Traumatol Arthrosc. 2013;21:2281–7.

    Article  Google Scholar 

  13. Nedopil AJ, Howell SM, Hull ML. What mechanisms are associated with tibial component failure after kinematically-aligned total knee arthroplasty? Int Orthop. 2017;41:1561–9.

    Article  Google Scholar 

  14. Abdel MP, Olivier M, Parratte S, Trousdale RT, Berry DJ, Pagnano MW. Effect of postoperative mechanical axis alignment on survival and functional outcomes of modern total knee arthroplasties with cement. A concise follow-up at 20 years. J Bone Joint Surg Am. 2018;100:472–8.

    Article  Google Scholar 

  15. Miyazaki Y, Nakamura T, Kogame K, Saito M, Yamamoto K, Suguro T. Analysis of the kinematics of total knee prostheses with a medial pivot design. J Arthroplast. 2011;26:1038–44.

    Article  Google Scholar 

  16. Roos EM, Roos HP, Lohmander LS, Ekdahl C, Beynnon BD. Knee injury and osteoarthritis outcome score (KOOS)--development of a self-administered outcome measure. J Orthop Sports Phys Ther. 1998;28:88–96.

    Article  CAS  Google Scholar 

  17. Behrend H, Giesinger K, Giesinger JM, Kuster MS. The “forgotten joint” as the ultimate goal in joint arthroplasty: validation of a new patient-reported outcome measure. J Arthroplast. 2012;27:430–6.

    Article  Google Scholar 

  18. Nakajima A, Sonobe M, Akatsu Y, Aoki Y, Takahashi H, Suguro T, Nakagawa K. Association between limb alignment and patient-reported outcomes after total knee arthroplasty using an implant that reproduces anatomical geometry. J Orthop Surg Res. 2018;13:320.

    Article  Google Scholar 

  19. Kilincoglu V, Unay K, Akan K, Esenkaya I, Poyanli O. Component alignment in simultaneous bilateral or unilateral total knee arthroplasty. Int Orthop. 2011;35:43–6.

    Article  Google Scholar 

  20. Ewald FC. The knee society total knee arthroplasty roentgenographic evaluation and scoring system. Clin Orthop Relat Res. 1989;248:9–12.

    Google Scholar 

  21. Insall JN, Dorr LD, Scott RD, Scott WN. Rationale of the knee society clinical rating system. Clin Orthop Relat Res. 1989;248:13–4.

    Google Scholar 

  22. Nakamura N, Takeuchi R, Sawaguchi T, Ishikawa H, Saito T, Goldhahn S. Cross-cultural adaptation and validation of the Japanese knee injury and osteoarthritis outcome score (KOOS). J Orthop Sci. 2011;16:516–23.

    Article  Google Scholar 

  23. Li Y, Wang S, Wang Y, Yang M. Does kinematic alignment improve short-term functional outcomes after total knee arthroplasty compared with mechanical alignment? A systematic review and meta-analysis. J Knee Surg. 2018;31:78–86.

    Article  Google Scholar 

  24. Takahashi T, Ansari J, Pandit HG. Kinematically aligned total knee arthroplasty or mechanically aligned total knee arthroplasty. J Knee Surg. 2018;31:999–1006.

    Article  Google Scholar 

  25. van Lieshout WAM, Duijnisveld BJ, Koenraadt KLM, Elmansa LHGJ, Kerkhoffs GMMJ, van Geenen RCI. Adequate joint line restoration and good preliminary clinical outcomes after total knee arthroplasty using the flexion first balancer technique. Knee. 2019;26:794–802.

    Article  Google Scholar 

  26. Luyckx T, Vandenneucker H, Ing LS, Vereecke E, Ing AV, Victor J. Raising the joint line in TKA is associated with mid-flexion laxity: a study in cadaver knees. Clin Orthop Relat Res. 2018;476:601–11.

    Article  Google Scholar 

  27. Parratte S, Ollivier M, Opsomer G, et al. Is knee function better with contemporary modular bicompartmental arthroplasty compared to total knee arthroplasty? Short-term outcomes of a prospective matched study including 68 cases. Orthop Traumatol Surg Res. 2015;101:547–52.

    Article  CAS  Google Scholar 

  28. Thomsen MG, Latifi R, Kallemose T, Husted H, Troelsen A. Does knee awareness differ between different knee arthroplasty prostheses? A matched, case-control, cross-sectional study. BMC Musculoskelet Disord. 2016;17:141.

    Article  Google Scholar 

  29. Katchky AM, Jones CW, Walter WL, Shimmin AJ. Medial ball and socket total knee arthroplasty FIVE-YEAR CLINICAL RESULTS. Bone Joint J. 2019;101-B(1 Supple A):59–65.

    Article  CAS  Google Scholar 

  30. Kaneyama R, Otsuka M, Shiratsuchi H, Oinuma K, Miura Y, Tamaki T. Criteria for preserving posterior cruciate ligament depending on intra-operative gap measurement in total knee replacement. Bone Joint Res. 2014;3:95–100.

    Article  CAS  Google Scholar 

  31. Shi X, Shen B, Kang P, Yang J, Zhou Z, Pei F. The effect of posterior tibial slope on knee flexion in posterior-stabilized total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc. 2013;21:2696–703.

    Article  Google Scholar 

  32. Han H, Oh S, Chang CB, Kang SB. Changes in femoral posterior condylar offset and knee flexion after PCL-substituting total knee arthroplasty: comparison of anterior and posterior referencing systems. Knee Surg Sports Traumatol Arthrosc. 2016;24:2483–8.

    Article  Google Scholar 

  33. Han HS, Kang SB. Interactive effect of femoral posterior condylar offset and tibial posterior slope on knee flexion in posterior cruciate ligament-substituting total knee arthroplasty. Knee. 2018;25:335–40.

    Article  Google Scholar 

Download references

Acknowledgements

Not applicable.

Funding

This study was funded by a Grant-in-aid Scientific Research of Japan (No. 20 K09469 to A.N.).

Author information

Authors and Affiliations

Authors

Contributions

AN and MSo participated in the design of the study, performed the statistical analysis and drafted the manuscript. HT and YaA participated in the design of the study and performed statistical analyses. YoA, MSa and MY participated in the design of the study and helped to draft the manuscript. KY, JS, MN and KK collected patients’ clinical information and made a part of figures and Tables. TS and KN conceived of the study, participated in its design and coordination and helped to revise the manuscript. All authors read and approved the final manuscript.

Corresponding author

Correspondence to Arata Nakajima.

Ethics declarations

Ethics approval and consent to participate

Approval for the study was received from the Institutional Review Board at Toho University Sakura Medical Center (S17017). Written informed consent was obtained from all the patients before surgery. All activities were performed in accordance with the ethical standards set forth in the Declaration of Helsinki.

Consent for publication

Not applicable.

Competing interests

The authors declare that they have no competing interest.

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Nakajima, A., Yamada, M., Sonobe, M. et al. Three-year clinical and radiological results of a cruciate-retaining type of the knee prosthesis with anatomical geometry developed in Japan. BMC Musculoskelet Disord 22, 241 (2021). https://doi.org/10.1186/s12891-021-04114-x

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s12891-021-04114-x

Keywords