In-Situ Examination of Microstructural Changes within a Lithium-Ion Battery Electrode Using Synchrotron X-ray Microtomography

, , , , , and

© 2015 ECS - The Electrochemical Society
, , Citation Oluwadamilola O. Taiwo et al 2015 ECS Trans. 69 81 DOI 10.1149/06918.0081ecst

1938-5862/69/18/81

Abstract

In this work, we use synchrotron X-ray microtomographic imaging to examine in-situ changes in a silicon / lithium half-cell before and after lithiation. We visualize volume expansion within the silicon electrode matrix and active particle fracturing as a result of the lithiation process. A change in volume fraction of silicon with respect to electrode state-of-charge was also characterized.

Export citation and abstract BibTeX RIS