skip to main content
research-article
Open Access

Liquid testing with your smartphone

Authors Info & Claims
Published:22 September 2021Publication History
Skip Abstract Section

Abstract

Surface tension is an important property of liquids. It has diverse uses such as testing water contamination, measuring alcohol concentration in drinks, and identifying the presence of protein in urine to detect the onset of kidney failure. Today, measurements of surface tension are done in a lab environment using costly instruments, making it hard to leverage this property in ubiquitous applications. In contrast, we show how to measure surface tension using only a smartphone. We introduce a new algorithm that uses the small waves on the liquid surface as a series of lenses that focus light and generate a characteristic pattern. We then use the phone camera to capture this pattern and measure the surface tension. Our approach is simple, accurate, and available to anyone with a smartphone. Empirical evaluations show that our mobile app can detect water contamination and measure alcohol concentration. Furthermore, it can track protein concentration in the urine, providing an initial at-home test for proteinuria, a dangerous complication that can lead to kidney failure.

References

  1. Behroozi, F., Perkins, A. Direct measurement of the dispersion relation of capillary waves by laser interferometry. Am. J. Phys. 74, 11 (2006), 957--961.Google ScholarGoogle ScholarCross RefCross Ref
  2. Blandford, R.D., Thorne, K.S. Applications of Classical Physics. California Institute of Technology, California, USA, 2008.Google ScholarGoogle Scholar
  3. Bormashenko, E., Musin, A. Revealing of water surface pollution with liquid marbles. Appl. Surf. Sci. 255, 12 (2009), 6429--6431.Google ScholarGoogle ScholarCross RefCross Ref
  4. Chen, H., Muros-Cobos, J.L., Amirfazli, A. Contact angle measurement with a smartphone. Rev. Sci. Instrum. 89, 3 (2018), 035117.Google ScholarGoogle ScholarCross RefCross Ref
  5. Chen, H., Muros-Cobos, J.L., Holgado-Terriza, J.A., Amirfazli, A. Surface tension measurement with a smartphone using a pendant drop. Colloids Surf. A Physicochem. Eng. Asp. 533, (2017), 213--217.Google ScholarGoogle ScholarCross RefCross Ref
  6. Cicconet, M., Birodkar, V., Lund, M., Werman, M., Geiger, D. A convolutional approach to reflection symmetry. Pattern Recognit. Lett. 95, (2017), 44--50.Google ScholarGoogle ScholarCross RefCross Ref
  7. Dhekne, A., Gowda, M., Zhao, Y., Hassanieh, H., Choudhury, R.R. Liquid: A wireless liquid identifier. In Proceedings of the 16th Annual International Conference on Mobile Systems, Applications, and Services (2018), ACM, Munich, Germany, 442--454.Google ScholarGoogle ScholarDigital LibraryDigital Library
  8. Diskin, C.J., Stokes, T.J., Dansby, L.M., Carter, T.B., Radcliff, L. Surface tension, proteinuria, and the urine bubbles of hippocrates. Lancet 355, 9207 (2000), 901--902.Google ScholarGoogle ScholarCross RefCross Ref
  9. FDS. Digital tensiometer -- dcat11, 2018. http://www.fdsc.com/wpdev15/?portfolio=dca11.Google ScholarGoogle Scholar
  10. A. Government. Microalbumin level; 2018. https://meteor.aihw.gov.au/content/index.phtml/itemId/270339/.Google ScholarGoogle Scholar
  11. Goy, N.A., Denis, Z., Lavaud, M., Grolleau, A., Dufour, N., Deblais, A., Delabre, U. Surface tension measurements with a smartphone. Phys. Teach. 55, 8 (2017), 498--499.Google ScholarGoogle ScholarCross RefCross Ref
  12. Ha, U., Ma, Y., Zhong, Z., Hsu, T.M., Adib, F. Learning food quality and safety from wireless stickers. In Proceedings of the 17th ACM Workshop on Hot Topics in Networks (2018), ACM, Redmond, Washington, USA, 106--112.Google ScholarGoogle ScholarDigital LibraryDigital Library
  13. Kruss. Force tensiometer -- k6, 2018. https://www.kruss-scientific.com/products/tensiometers/force-tensiometer-k6/.Google ScholarGoogle Scholar
  14. Liang, C.K., Chang, L.W., Chen, H.H. Analysis and compensation of rolling shutter effect. IEEE Transactions on Image Processing, 2008.Google ScholarGoogle Scholar
  15. Mogensen, C. Microalbuminuria predicts clinical proteinuria and early mortality in maturity-onset diabetes. N. Engl. J. Med. 310, 6 (1984), 356--360.Google ScholarGoogle ScholarCross RefCross Ref
  16. Pye, V.I., Patrick, R. Ground water contamination in the united states. Science 221, 4612 (1983), 713--718.Google ScholarGoogle ScholarCross RefCross Ref
  17. Rahman, T., Adams, A.T., Schein, P., Jain, A., Erickson, D., Choudhury, T. Nutrilyzer: A mobile system for characterizing liquid food with photoacoustic effect. In SenSys. ACM, Stanford, CA, 2016.Google ScholarGoogle Scholar
  18. Speight, J.G., et al. Lange's handbook of chemistry, Volume 1. McGraw-Hill, New York, 2005.Google ScholarGoogle Scholar
  19. Sridhar, M., Reddy, C.R. Surface tension of polluted waters and treated wastewater. Environ. Pollut. B. Chem. Phys. 7, 1 (1984), 49--69.Google ScholarGoogle ScholarCross RefCross Ref
  20. Vazquez, G., Alvarez, E., Navaza, J.M. Surface tension of alcohol + water from 20 to 50°c. J. Chem. Eng. Data 40, 3 (1995), 611--614.Google ScholarGoogle ScholarCross RefCross Ref
  21. Wang, J., Xiong, J., Chen, X., Jiang, H., Balan, R.K., Fang, D. Tagscan: Simultaneous target imaging and material identification with commodity rfid devices. In Proceedings of the 23rd Annual International Conference on Mobile Computing and Networking. ACM, Salt Lake City, Utah, USA, 2017.Google ScholarGoogle ScholarDigital LibraryDigital Library
  22. Wei, M., Huang, S., Wang, J., Li, H., Yang, H., Wang, S.. The study of liquid surface waves with a smartphone camera and an image recognition algorithm. Eur. J. Phys. 36, 6 (2015), 065026.Google ScholarGoogle ScholarCross RefCross Ref
  23. Yeo, H.S., Flamich, G., Schrempf, P., Harris-Birtill, D., Quigley, A. Radarcat: Radar categorization for input & interaction. In Proceedings of the 29th Annual Symposium on User Interface Software and Technology. ACM, Tokyo, Japan, 2016.Google ScholarGoogle ScholarDigital LibraryDigital Library
  24. Zhu, F., Miao, R., Xu, C., Cao, Z. Measurement of the dispersion relation of capillary waves by laser diffraction. Am. J. Phys. 75, 10 (2007), 896--898.Google ScholarGoogle ScholarCross RefCross Ref

Index Terms

  1. Liquid testing with your smartphone

      Recommendations

      Comments

      Login options

      Check if you have access through your login credentials or your institution to get full access on this article.

      Sign in

      Full Access

      • Published in

        cover image Communications of the ACM
        Communications of the ACM  Volume 64, Issue 10
        October 2021
        89 pages
        ISSN:0001-0782
        EISSN:1557-7317
        DOI:10.1145/3487943
        Issue’s Table of Contents

        Copyright © 2021 Owner/Author

        This work is licensed under a Creative Commons Attribution International 4.0 License.

        Publisher

        Association for Computing Machinery

        New York, NY, United States

        Publication History

        • Published: 22 September 2021

        Permissions

        Request permissions about this article.

        Request Permissions

        Check for updates

        Qualifiers

        • research-article
        • Research
        • Refereed

      PDF Format

      View or Download as a PDF file.

      PDF

      eReader

      View online with eReader.

      eReader

      HTML Format

      View this article in HTML Format .

      View HTML Format