ABSTRACT
Body temperature is one of the key parameters for health monitoring of premature infants at the neonatal intensive care unit (NICU). In this paper, we propose and demonstrate a design of non-invasive neonatal temperature monitoring with wearable sensors. A negative temperature coefficient (NTC) resistor is applied as the temperature sensor due to its accuracy and small size. Conductive textile wires are used to make the sensor integration compatible for a wearable non-invasive monitoring platform, such as a neonatal smart jacket. Location of the sensor, materials and appearance are designed to optimize the functionality, patient comfort and the possibilities for aesthetic features. A prototype belt is built of soft bamboo fabrics with NTC sensor integrated to demonstrate the temperature monitoring. Experimental results from the testing on neonates at NICU of Máxima Medical Center (MMC), Veldhoven, the Netherlands, show the accurate temperature monitoring by the prototype belt comparing with the standard patient monitor.
- R. A. Polin and W. W. Fox, (Eds.), Fetal and Neonatal Physiology, W. B. Saunders Company, 1992.Google Scholar
- K. Costeloe, E. Hennessy, A. T. Gibson, et al., "The EPICure study: Outcome to discharge from hospital for infants born at the threshold of viability", Pediatrics, vol. 106, no. 4, 2000, pp. 659--671.Google ScholarCross Ref
- I. Murković, M. D. Steinberg and B. Murković, "Sensors in neonatal monitoring: Current practice and future trends", Technology and Health Care, IOS Press, vol. 11, 2003, pp. 399--412. Google ScholarDigital Library
- H. Als, et al., "A Three-Center, Randomized, Controlled Trial of Individualized Developmental Care for Very Low Birth Weight Preterm Infants: Medical, Neurodevelopmental, Parenting and Caregiving Effects", Journal of Developmental and Behavioral Pediatrics, vol. 24, 2003, pp. 399--408.Google ScholarCross Ref
- M. J. De Kleine, et al., "Lower mortality but higher neonatal morbidity over a decade in very preterm infants", Paediatr Perinat Epidemiol, vol. 21, no. 1, 15--25, 2007.Google ScholarCross Ref
- G. Yang, Ed., Body Sensor Networks, Springer-Verlag London Limited, 2006.Google Scholar
- X. M. Tao, Ed., Wearable electronics and photonics, CRC press, Woodhead Publishing Ltd, England, March 2005.Google Scholar
- L. Van Langenhove, Ed, Smart Textiles for Medicine and Healthcare: Materials, Systems and Applications, CRC press, Woodhead Publishing Ltd., England, Feb. 2007.Google Scholar
- A. Goldsmith, Wireless Communications, Cambridge University Press, 2005. Google ScholarDigital Library
- W. Chen, S. Bambang Oetomo, and L. M. G. Feijs, "Neonatal Monitoring -- Current Practice and Future Trends", Handbook of Research on Developments in e-Health and Telemedicine: Technological and Social Perspectives, IGI Global, Dec. 2009.Google Scholar
- S. Bouwstra, W. Chen, L. M. G Feijs, and S. Bambang Oetomo, "Smart jacket design for neonatal monitoring with wearable sensors," in Proc. Body Sensor Networks (BSN) 2009, Berkeley, USA, pp. 162--167, 2009. Google ScholarDigital Library
- W. Chen, I. Ayoola, S. Bambang Oetomo, L. Feijs, "Non-invasive Blood Oxygen Saturation Monitoring for Neonates Using Reflectance Pulse Oximeter", Design, Automation and Test in Europe - Conference and Exhibition 2010 (DATE 2010), Deresden, Germany, March 2010. Google ScholarDigital Library
- W. Chen, S. T. Nguyen, R. Coops, S. Bambang Oetomo, L. Feijs, "Wireless Transmission Design for Health Monitoring at Neonatal Intensive Care Units", the 2nd international symposium on applied sciences in biomedical and communication technologies (ISABEL 2009), Bratislava, Slovakia, Nov. 2009.Google Scholar
- W. Chen, C. L. W. Sonntag, F. Boesten, S. Bambang Oetomo, and L. M. G. Feijs, "A Design of Power Supply for Neonatal Monitoring with Wearable Sensors", Journal of Ambient Intelligence and Smart Environments-Special Issue on Wearable Sensors, vol.1, no. 2, pp. 185--196, 2009, IOS press. Google ScholarDigital Library
- W. Chen, S. Bambang Oetomo, L. M. G Feijs, P. Andriessen, F. Kimman, M. Geraets, and M. Thielen, "Rhythm of Life Aid (ROLA): An Integrated Sensor System for Supporting Medical Staff during Cardiopulmonary Resuscitation (CPR) of Newborn Infants," to be appear in IEEE Transactions on Information Technology in Biomedicine, 2010. Google ScholarDigital Library
- A. K. Abbas, and S. Leonhardt, "System Identification of Neonatal Incubator based on Adaptive ARMAX Technique", 4th European Congress for Medical and Biomedical Engineering, Antwerp, Belgium, Nov 2008.Google Scholar
- Raytek Noncontact Infrared Temperature Measurement. {Online}. Available: http://www.raytek.com/Raytek/en-r0/IREducation/.Google Scholar
- S. Dollberg, et al., "Continuous measurement of core body temperature in preterm infants", Am J Perinatol., vol. 17, no. 5, pp. 257--64, 2000.Google ScholarCross Ref
- NTC Engineering Notes. {Online}. Available: http://www.specsensors.com/ntc-engineering.asp.Google Scholar
Recommendations
A design of power supply for neonatal monitoring with wearable sensors
Continuous monitoring of health parameters is crucial for preterm new born babies admitted at the neonatal intensive care unit (NICU) in hospitals. The critically ill neonates are extremely tiny and vulnerable to external disturbance. In the context of ...
A design of power supply for neonatal monitoring with wearable sensors
Continuous monitoring of health parameters is crucial for preterm new born babies admitted at the neonatal intensive care unit (NICU) in hospitals. The critically ill neonates are extremely tiny and vulnerable to external disturbance. In the context of ...
Smart Jacket Design for Neonatal Monitoring with Wearable Sensors
BSN '09: Proceedings of the 2009 Sixth International Workshop on Wearable and Implantable Body Sensor NetworksCritically ill new born babies admitted at the Neonatal Intensive Care Unit (NICU) are extremely tiny and vulnerable to external disturbance. Smart Jacket proposed in this paper is the vision of a wearable unobtrusive continuous monitoring system ...
Comments