Skip to main content
Log in

Test of the Neutron Detector in the Nuclotron Extraction Beamline

  • METHODS OF PHYSICAL EXPERIMENT
  • Published:
Physics of Particles and Nuclei Letters Aims and scope Submit manuscript

Abstract

Characteristics of the neutron detector are investigated at the MARUSYA facility in the region of the F4 focus using an extracted deuteron beam from the Nuclotron accelerator (Laboratory of High Energy Physics, Joint Institute for Nuclear Research (LHEP JINR)). It is shown that the neutron detection efficiency is about 27%. With its time characteristics, the detector can be used in the SCAN-3 experimental facility for detecting nucleons from the decay of the η nucleus via the πn and pn channels.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1.
Fig. 2.
Fig. 3.
Fig. 4.
Fig. 5.
Fig. 6.
Fig. 7.
Fig. 8.
Fig. 9.
Fig. 10.

Similar content being viewed by others

REFERENCES

  1. S. V. Afanasev et al. (SCAN Collab.), “New status of the project ‘η-nuclei’ at the nuclotron,” Nucl. Phys. B 245, 173–176 (2013).

    Article  Google Scholar 

  2. Q. Haider and L. C. Liu, “Dependence of calculated binding energies and widths of η-mesic nuclei on treatment of subthreshold η-nucleon interaction,” Phys. Rev. C 66, 045208 (2002).

    Article  ADS  Google Scholar 

  3. C. García-Recio, T. Inoue, J. Nieves, and E. Oset, “η bound states in nuclei,” Phys. Lett. B 550, 47 (2002).

    Article  ADS  Google Scholar 

  4. M. Pfeiffer et al., “Photoproduction of η-mesic 3He,” Phys. Rev. Lett. 92, 252001 (2004).

    Article  ADS  Google Scholar 

  5. A. Budzanowski et al. (COSY-GEM Collab.), “Search for η-mesic nuclei in a recoil-free transfer reaction,” Phys. Rev. C 79, 012201 (2009).

    Article  ADS  Google Scholar 

  6. A. A. Baldin et al., “Experimental study of asymmetries in the pi+, p, d inclusive spectra in the interaction of polarized protons and deuterons with carbon targets at the MARUSA facility,” JINR Preprint R1–2007-180 (JINR, Dubna, 2007).

    Google Scholar 

Download references

ACKNOWLEDGMENTS

We are grateful to E.V. Rzhanov for help with measurements.

Funding

This work was supported by the Ministry of Education, Science, Research, and Sport of the Slovak Republic, grant no. VEGA 1/113/18.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to D. K. Dryablov.

Additional information

Translated by M. Potapov

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Afanasev, S.V., Baldin, A.A., Baskov, V.A. et al. Test of the Neutron Detector in the Nuclotron Extraction Beamline. Phys. Part. Nuclei Lett. 16, 327–332 (2019). https://doi.org/10.1134/S1547477119040022

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1134/S1547477119040022

Navigation