Abstract
A simple method is proposed for the determination and speciation of Mn(II) and Mn(VII) in waters utilizing a macroporous resin, Amberlite XAD-7HP. The batch method was employed and flame atomic absorption spectrometry was used in all determinations. Amberlite XAD-7HP resin was shown to retain Mn(VII) between pH 4 and 12. If the solution contains only one of the species, either Mn(II) or Mn(VII), the resin behaves selectively depending on the pH of the solution. The elution from the sorbent was realized using K2C2O4 in HNO3. The efficiency of the method was checked via spike recovery experiments. The proposed method was successfully applied to industrial wastewater samples and quantitative recoveries (≥96.0%) confirmed the accuracy of the method.
Similar content being viewed by others
References
Michalke, B. and Fernsebner, K.J., Trace Elem. Med. Biol., 2014, vol. 28, no. 2, p. 106.
Oliveira, R.L.F., Pedrobom, J.H., Menegario, A.A., Domingos, R.N., Junior, D.A.P., and Kiang, C.H., Anal. Chim. Acta, 2013, vol. 799, p. 23.
Citak, D., Tuzen, M., and Soylak, M., J. Hazard Mater., 2010, vol. 173, nos.1–3, p. 773.
Abdolmohammad-Zadeh, H. and Sadeghi, G.H., Talanta, 2012, vol. 94, p. 201.
Pacini, V.A., Ingallinella, A.M., and Sanguinetti, G., Water Res., 2005, vol. 39, no. 18, p. 4463.
Yebra, M.C. and Moreno-Cid, A., Anal. Chim. Acta, 2003, vol. 477, p. 149.
Stumm, W. and Morgan, J.J., Aqua Aquatic Chemistry: Chemical Equilibria and Rates in Natural Waters, New York: Wiley, 1996, 3rd ed.
Florence, T.M., Talanta, 1982, vol. 29, p. 345.
Quddane, B., Martin, E., Boughriet, A., Fischer, J.C., and Wartel, M., Mar. Chem., 1997, vol. 58, p. 189.
Qian, A.X.S., He, G.H.F., and Han, X., Analyst, 2001, vol. 126, p. 239.
Guidelines for Drinking-Water Quality, Geneva: World Health Org., 2008, 3rd ed.
Welz, B. and Sperling, M., Atomic Absorption Spectrometry, Weinheim Wiley, 1999.
Frisbie, S.H., Ortega, R., Maynard, D.M., and Sarkar, B., Environ. Health Perspect., 2002, vol. 110, no. 11, p. 1147.
Yebra-Biurrun, M.C., Garcia-Dopazo, M.C., Bermejo-Barrera, A., and Bermejo-Barrera, M.P., Talanta, 1992, vol. 39, p. 671.
Özdemir, Y. and Güçer, S,., Anal. Lett., 1998, vol. 31, no. 4, p. 679.
Alfassi, Z.B. and Wai, C.M., Preconcentration Techniques for Trace Elements, Eds., Boca Raton, FL:CRC, 1992.
Dogutan, M., Filik, H., and Apak, R., Anal. Chim. Acta, 2003, vol. 485, p. 205.
Skoog, D.A. and West, D.M., Fundamentals of Analytical Chemistry, New York: Holt–Saunders, 1997, 7th ed.
Shirkhanloo, H., Khaligh, A., Mousavi, H.Z., and Rashidi, A., Microchem. J., 2016, vol. 124, p. 637.
Karadas, C. and Kara, D., J. Food Compos. Anal., 2013, vol. 32, p. 90.
Anjos, A.P., Cornejo-Ponce, L., Cadore, S., and Baccan, N., Talanta, 2007, vol. 71, p. 1252.
Kendüzler, E. and Türker, A.R., Anal. Sci., vol. 18, no. 8, p. 917.
Afzali, D., Taher, M.A., Mostafavi, A., Ziae, S., and Mobarakeh, M., Talanta, 2005, vol. 65, p. 476.
Author information
Authors and Affiliations
Corresponding author
Additional information
The article is published in the original.
Rights and permissions
About this article
Cite this article
Yayayürük, A.E., Eroğlub, A.E. Use of amberlite XAD-7HP for the separation of Mn(II) and Mn(VII) in waters. J Anal Chem 72, 63–69 (2017). https://doi.org/10.1134/S106193481701004X
Received:
Revised:
Published:
Issue Date:
DOI: https://doi.org/10.1134/S106193481701004X