Abstract
We report an 885 nm laser diode (LD) end-pumped high beam quality (M 2 x = 1.322, M 2 y = 1.235) electro-optical Q-switched Nd:YAG laser with TEM00-mode output for the first time. At the absorbed pump power of 59.5 W, a 22.7 W 1064 nm laser was achieved at 10 kHz repetition rate with optical-to-optical efficiency of 38.1%. The maximum pulse energy and shortest pulse width were 5.1 mJ and 14.5 ns at 2 kHz repetition rate, and the calculated peak power was 352 kW.
Similar content being viewed by others
References
X. Yan, Q. Liu, H. Chen, X. Fu, M. Gong, and D. Wang, Laser Phys. Lett. 7, 563 (2010).
Q. Liu, X. P. Yan, X. Fu, M. Gong, and D. S. Wang, Laser Phys. Lett. 6, 203 (2009).
X. P. Yan, Q. Liu, M. Gong, D. S. Wang, and X. Fu, Laser Phys. Lett. 6, 93 (2009).
W. J. Sun, Q. P. Wang, Z. J. Liu, X. Y. Zhang, G. T. Wang, F. Bai, W. X. Lan, X. B. Wan, and H. J. Zhang, Laser Phys. Lett. 8, 512 (2011).
Sh. B. Zhang, Q. J. Cui, B. Xiong, L. Guo, W. Hou, X. C. Lin, and J. M. Li, Laser Phys. Lett. 7, 707 (2010).
L. McDonagh, R. Wallenstein, and R. Knappe, Opt. Lett. 31, 3303 (2006).
M. Jelínek Jr. and V. Kubecek, Laser Phys. Lett. 8, 657 (2011).
C. X. Wang, G. Y. Wang, A. V. Hicks, D. R. Dudley, H. Y. Pang, and N. Hodgson, Proc. SPIE 6100, 610019-1–14 (2006).
X. Yan, L. Guo, L. Zhang, R. Chen, W. Hou, X. C. Lin, and J. M. Li, Laser Phys. 21, 323 (2011).
C. Zhang, X. Y. Zhang, Q. P. Wang, S. Z. Fan, X. H. Chen, Z. H. Cong, Z. J. Liu, Z. Zhang, H. J. Zhang, and F. F. Su, Laser Phys. Lett. 6, 505 (2009).
S. S. Zhang, Q. P. Wang, X. Y. Zhang, Z. J. Liu, W. J. Sun, and S. W. Wang, Laser Phys. 19, 2159 (2009).
J. Tauer, H. Kofler, and E. Wintner, Laser Phys. Lett. 7, 280 (2010).
M. Frede, R. Wilhelm, and D. Kracht, Opt. Lett. 31, 3618 (2006).
Y. F. Lü, X. H. Zhang, J. Xia, X. D. Yin, L. Bao, and H. Quan, Laser Phys. 20, 200 (2010).
R. Lavi, S. Jackel, A. Tal, E. Leibiush, Y. Tzuk, and S. Goldring, Opt. Comm. 195, 427 (2001).
S. Goldring, R. Lavi, A. Tal, S. Jackel, E. Lebiush, Y. Tzuk, and E. Azoulay, Proc. SPIE 4968, 75 (2003).
M. Frede, D. Freiburg, R. Wilhelm, and D. Kracht, Proc. SPIE 6451, 64510G (2007).
N. Zong, X. F. Zhang, Q. L. Ma, B. S. Wang, D. F. Cui, Q. J. Peng, Z. Y. Xu, Y. B. Pan, and X. Q. Feng, Chin. Phys. Lett. 26, 054211 (2009).
F. Q. Li, X. F. Zhang, N. Zong, J. Yang, Q. J. Peng, D. F. Cui, and Z. Y. Xu, Chin. Phys. Lett. 26, 114206 (2009).
M. L. Li, W. F. Zhao, W. Hou, B. Xiong, S. B. Zhang, X. C. Lin, and J. M. Li, Laser Phys. 21, 1738 (2011).
X.-F. Zhang, F.-Q. Li, N. Zong, X.-Y. Le, D.-F. Cui, and Z.-Y. Xu, Laser Phys. 21, 435 (2011).
Y. T. Chang, Y. P. Huang, K. W. Su, and Y. F. Chen, Opt. Express 16, 21155 (2008).
W. A. Clarkson, N. S. Felgate, and D. C. Hanna, Opt. Lett. 24, 820 (1999).
Author information
Authors and Affiliations
Corresponding author
Additional information
Original Text © Astro, Ltd., 2012.
The article is published in the original.
Rights and permissions
About this article
Cite this article
Chang, L., Yang, C., Pang, Q.S. et al. 885 nm LD end-pumped 22.7 W high beam quality electro-optical Q-switched Nd:YAG laser. Laser Phys. 22, 914–917 (2012). https://doi.org/10.1134/S1054660X12050040
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1134/S1054660X12050040