Abstract
A refined procedure for estimating the effect the flashing of condensate in a steam turbine’s regenerative and delivery-water heaters on the increase of rotor rotation frequency during rejection of electric load is presented. The results of calculations carried out according to the proposed procedure as applied to the delivery-water and regenerative heaters of a T-110/120-12.8 turbine are given.
Similar content being viewed by others
References
M. S. Fragin, Control and Oil Supply Systems of Steam Turbines: Design, Adjustment, and Operation Aspects (Kosta, St. Petersburg, 2011) [in Russian].
M. S. Fragin and V. B. Novoselov, “The Influence of Water and Steam Volumes in the Regenerative and Delivery-Water Heaters of Steam Turbines on the Turbine Performance during Load Rejection,” Elektr. Stn., No. 2, 31–38 (2011).
S. L. Rivkin and A. A. Aleksandrov, Thermophysical Properties of Water and Steam (Energiya, Moscow, 1980) [in Russian].
A. A. Aleksandrov, K. A. Orlov, A. V. Ochkov, and V. F. Ochkov, Thermophysical Properties of Water and Steam in the Internet (An Electronic Document), http://twt.mpei.ac.ru.ochkov/WspIn/index.html. Checked on January 4, 2012.
Water/Steam Properties at Saturated Line IAPWS-IF97 (An Electronic Document), http:/twt.mpei.ac.ru/MCS/Worksheets/WSP/Plot-Sat-P.xmcd. Checked on January 4, 2012.
Parameters of Water and Steam in Double Phase (An Electronic Document), http://twt.mpei.ac.ru/MCS/Worksheets/WSP/XPTHSV.xmcd. Checked on January 4, 2012.
G. D. Barinberg, Yu. M. Brodov, A. A. Gol’dberg, et al., Steam Turbines and Turbine Installations Produced by the Ural Turbine Works, Ed. by Yu. M. Brodov and V. V. Kortenko, a revised and extended 2nd ed. (Aprio, Yekaterinburg, 2010) [in Russian].
A. V. Rabinovich and D. P. Buzin, “A Device for Preventing Condensate Flashing in a Heat Exchanger,” a USSR Inventor’s Certificate No. 128875, Izobret., No. 11, 19 (1960).
Author information
Authors and Affiliations
Additional information
Original Russian Text © V.B. Novoselov, M.V. Shekhter, 2012, published in Teploenergetika.
Rights and permissions
About this article
Cite this article
Novoselov, V.B., Shekhter, M.V. Refining the calculation procedure for estimating the influence of flashing steam in steam turbine heaters on the increase of rotor rotation frequency during rejection of electric load. Therm. Eng. 59, 924–929 (2012). https://doi.org/10.1134/S0040601512120087
Published:
Issue Date:
DOI: https://doi.org/10.1134/S0040601512120087