Refining the calculation procedure for estimating the influence of flashing steam in steam turbine heaters on the increase of rotor rotation frequency during rejection of electric load

  • Published:
Thermal Engineering Aims and scope Submit manuscript

Abstract

A refined procedure for estimating the effect the flashing of condensate in a steam turbine’s regenerative and delivery-water heaters on the increase of rotor rotation frequency during rejection of electric load is presented. The results of calculations carried out according to the proposed procedure as applied to the delivery-water and regenerative heaters of a T-110/120-12.8 turbine are given.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

References

  1. M. S. Fragin, Control and Oil Supply Systems of Steam Turbines: Design, Adjustment, and Operation Aspects (Kosta, St. Petersburg, 2011) [in Russian].

    Google Scholar 

  2. M. S. Fragin and V. B. Novoselov, “The Influence of Water and Steam Volumes in the Regenerative and Delivery-Water Heaters of Steam Turbines on the Turbine Performance during Load Rejection,” Elektr. Stn., No. 2, 31–38 (2011).

  3. S. L. Rivkin and A. A. Aleksandrov, Thermophysical Properties of Water and Steam (Energiya, Moscow, 1980) [in Russian].

    Google Scholar 

  4. A. A. Aleksandrov, K. A. Orlov, A. V. Ochkov, and V. F. Ochkov, Thermophysical Properties of Water and Steam in the Internet (An Electronic Document), http://twt.mpei.ac.ru.ochkov/WspIn/index.html. Checked on January 4, 2012.

  5. Water/Steam Properties at Saturated Line IAPWS-IF97 (An Electronic Document), http:/twt.mpei.ac.ru/MCS/Worksheets/WSP/Plot-Sat-P.xmcd. Checked on January 4, 2012.

  6. Parameters of Water and Steam in Double Phase (An Electronic Document), http://twt.mpei.ac.ru/MCS/Worksheets/WSP/XPTHSV.xmcd. Checked on January 4, 2012.

  7. G. D. Barinberg, Yu. M. Brodov, A. A. Gol’dberg, et al., Steam Turbines and Turbine Installations Produced by the Ural Turbine Works, Ed. by Yu. M. Brodov and V. V. Kortenko, a revised and extended 2nd ed. (Aprio, Yekaterinburg, 2010) [in Russian].

    Google Scholar 

  8. A. V. Rabinovich and D. P. Buzin, “A Device for Preventing Condensate Flashing in a Heat Exchanger,” a USSR Inventor’s Certificate No. 128875, Izobret., No. 11, 19 (1960).

Download references

Author information

Authors and Affiliations

Authors

Additional information

Original Russian Text © V.B. Novoselov, M.V. Shekhter, 2012, published in Teploenergetika.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Novoselov, V.B., Shekhter, M.V. Refining the calculation procedure for estimating the influence of flashing steam in steam turbine heaters on the increase of rotor rotation frequency during rejection of electric load. Therm. Eng. 59, 924–929 (2012). https://doi.org/10.1134/S0040601512120087

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1134/S0040601512120087

Keywords

Navigation