Abstract
We report results from an extensive set of measurements of the -decay response in liquid xenon. These measurements are derived from high-statistics calibration data from injected sources of both and in the LUX detector. The mean light-to-charge ratio is reported for 13 electric field values ranging from 43 to , and for energies ranging from 1.5 to 145 keV.
4 More- Received 2 April 2019
DOI:https://doi.org/10.1103/PhysRevD.100.022002
© 2019 American Physical Society