Abstract
Corrosion degradation was observed in a nuclear power plant spent fuel cooling system. A systematic and comprehensive investigation program was developed to reveal the root cause of the degradation. Series of corrosion tests, mechanical, microstructural and microbiological investigations were carried out. Also, simulations of the operating conditions and welding parameters were performed. Based on the results, the major contributors to the degradation process were identified and a possible degradation mechanism was proposed.
Export citation and abstract BibTeX RIS
Content from this work may be used under the terms of the Creative Commons Attribution 3.0 licence. Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI.