Paper The following article is Open access

Arc tracking energy balance for copper and aluminum aeronautic cables

, , , , and

Published under licence by IOP Publishing Ltd
, , Citation T André et al 2017 J. Phys.: Conf. Ser. 825 012001 DOI 10.1088/1742-6596/825/1/012001

1742-6596/825/1/012001

Abstract

Arc tracking tests have been carried out between two voluntarily damaged aeronautic cables. Copper or aluminum conductors have been exposed to short circuits under alternating current. Various data have been recorded (arc voltage and current, radiated power and ablated mass), enabling to determine a power balance, in which every contribution is estimated. The total power is mainly transferred to the cables (between 50 and 65%, depending on the current and the cable type), and causes the melting and partial vaporization of the metallic core and insulating material, or is conducted or radiated. The other part is deposited into the arc column, being either radiated, convected or conducted.

Export citation and abstract BibTeX RIS

Content from this work may be used under the terms of the Creative Commons Attribution 3.0 licence. Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI.

Please wait… references are loading.
10.1088/1742-6596/825/1/012001